SPECIFICATIONS
Method: Colorimetric (DR 900)
Range: 16 to 500 ppb as hydrazine (N2H4)
Testing Time: 15 minutes

DESCRIPTION
The portable Nalco DR 900 colorimeter enables
extremely sensitive analysis of residual hydrazine.
The test reacts any residual (unoxi-dized) hydra-
zine with p-dimethylaminobenzalde-hyde to form
a highly colored yellow complex. The intensity of
the yellow complex is directly proportional to the
hydrazine concentration.

ORDERING INFORMATION
Order all replacement parts and reagents by their Nalco DR 900 Colorimeter
part numbers. To be sure this product is compatible
with your treatment program, contact your local
Nalco representative. Items marked with an “*” Optional Parts and Reagents
are included with the kit or set. To place your
Description Part No.
order, please contact your local customer service
Cylinder, graduated, mixing, glass,
department.
50 mL 500-P1206.88
Dropper bottle, 2 oz. (60 mL), plastic 500-P0359.88
REPLACEMENT PARTS AND REAGENTS Stopwatch/timer 500-P1612.88
Sample cooler II, (316 SS/MS) 500-P4627.88
Required Parts and Reagents Thermometer, dial, 50 to 300°F 500-P2019.88
Description Size Part No. Thermometer, digital, –40 to 450°F 500-P2098.88
HZ-1 1.7 oz/50 mL 460-S0718.71
HZ-1 16.9 oz/500 mL 460-S0718.74 INTERFERENCES
Deionized water 1.06 gal/4 L 460-S0470.77
For highly colored or turbid samples, prepare a
Nalco DR 900 Colorimeter 400-P0900.88
blank by oxidizing the hydrazine in a portion of the
Cylinder, graduated, glass, 25 mL 500-P1204.88
sample. This can be accomplished with a 1:1 mixture
Sample cells, 10-20-25 mL, w/cap,
of deionized water and a household bleach such as
6/pkg 500-P2555.88
Clorox. Add one drop of the mixture to 25 mL of
sample in a mixing graduated cylinder and invert
to mix. Use this solution in Step 2, in place of
deionized water, to prepare the blank. There are
no other common interferences.
SAFETY PRECAUTIONS SAMPLING
Refer to Material Safety Data Sheet (MSDS) for 1. This test measures very low levels of the oxygen
specific reagent personal safety and disposal scavenger, hydrazine. These samples are not
information. very stable and should not be agitated. Perform
the test immediately after collecting the sample.
Clean and prepare all glassware being used
SUPPORT
for sampling and analysis prior to drawing the
If you have any questions regarding this procedure, sample.
please contact your Nalco representative. In North
America you can also contact the Equipment Help 2. The sample should be cooled (using a stainless
Desk at 630-305-CHEM. steel sample cooler) and the sample lines flushed
thoroughly before drawing a sample.

HYDRAZINE DR 900 PROCEDURE

Special Note: Samples must be analyzed immediately and cannot be preserved for later analysis.
Samples collected in bottles should be filled completely and tightly capped.

Start

1 2 3 4
Start Program Pour 10.0 mL of deionized Pour 10.0 mL of sample into Add 0.5 mL of HZ-1 (460-
water into a sample cell (the a second sample cell (the S0718) to each sample cell.
231 Hydrazine blank) using a graduated prepared sample) using a Cap. Invert to mix.
cylinder. graduated cylinder.

Notes: Sample should not Notes: A yellow color will


be agitated and should be develop if hydrazine is
tested immediately. present.

Sample temperature should HZ-1 Reagent will cause a


be 21 ± 4°C (70 ± 7°F). faint yellow color to appear
in the blank.
Zero

5 6 7 8
Start TIMER 1 Immediately after the timer Press: ZERO Place the prepared sample
beeps place the blank into into the cell holder. Tightly
A 12-minute reaction period the cell holder. Tightly cover The cursor will move to the
will begin. right, then the display will cover the sample cell with
the sample cell with the the instrument cap.
instrument cap. show:

Note: Complete Steps 6-9 0 µg/L N2H4


within 3 minutes.

Read

9
Immediately after the timer
beeps, press:
READ
The cursor will move to the
right, then the result in µg/L
hydrazine will be displayed.

Nalco, an Ecolab Company


North America: Headquarters – 1601 West Diehl Road • Naperville, Illinois 60563 • USA
Nalco Champion – 7705 Highway 90-A • Sugar Land, Texas 77487 • USA
Europe: Richtistrasse 7 • 8304 Wallisellen • Switzerland
Asia Pacific: 2 International Business Park • #02-20 The Strategy Tower 2 • Singapore 609930
Latin America: Av. das Nações Unidas 17.891 • 6° Andar 04795-100 • São Paulo • SP • Brazil
www.nalco.com

Ecolab, NALCO and the logos are trademarks of Ecolab USA Inc.
©2013 Ecolab USA Inc. All Rights Reserved 8/13

You might also like