You are on page 1of 1

Date: Note No: 9435/E/DN-44,45,46-102

Stup Consultants P. Ltd.


Designed By: KDG Sheet No:

Calculation of Pile Reinforcement of Pile A1 as per SP-16


In ULS Codition :
Maximum diameter of Main Reinforcement = 32 mm
Dia of Transverse Reinforcement = 12 mm
Clear Cover = 75 mm
Grade of Concrete = M40
Grade of Reinforcement = Fe500 75 mm D
Hence d' = 103 mm
Overall Depth D= 1200 mm
Hence d'/D = 0.086 say = 0.1 12 mm d'
32 mm

Reinforcement: From chart 60 of SP 16

Pu Mux Pu/fckD2 Mxu/fckD3 p/fck = p=


Case I: 155.00 213.00 0.0269 0.031 0.02 0.80
Case II: 12.96 213.00 0.0023 0.031 0.025 1.00
Case III: 173.00 196.00 0.0300 0.028 0.02 0.80
Case IV: 96.27 196.00 0.0167 0.028 0.02 0.80

Provided T32 dia bars 20 nos. in 1 layers

% of reinforcement provided = 1.42 % Hence OK