You are on page 1of 2

DYO, DYOV

Document # PG01-011 Revised 09/23/13 Page 1/2

Discovery™ iQ 30” Wide PLANNING


Single Wall Ovens GUIDE
Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated.
warning
• Observe all governing codes and ordinances during planning 1 1/8” 1 1/8” 1 1/8”
(2.9 cm) (2.9 cm) (2.9 cm)
and installation. Contact your local building department for
3 1/2” 3 3/16”
further information. (8.9 cm) (8.1 cm)
• This appliance must be installed in accordance with the
accompanying installation instructions.

Dedicated Circuit Total


Required Connected Load**
240 Vac, 4-wire*, 240 Vac 60 Hz,
60Hz, 30 Amp. 22.5 Amp. 5.4 kW
* Two 120 Vac hot (L1 and L2), one neutral,
one ground.
** This specification is for reference only. See HANDLE DIMENSIONS - SIDE VIEW
the product data label for exact specifications.

Top of
K chassis
B
Utility
J cutout F
G

C H
D

21 7/8” A
(55.6) cm
Conduit:
60” (152 cm)
Control panel long
front Top of
E
chassis
Control panel
side view

A B C D E F G H J K
29 7/8” 28 1/4” 28 3/4” 27 7/16” 1 5/16” 6 1/2” 5” 7 7/8” 1 3/8” 23 1/2”
(75.9 cm) (71.8 cm) (73.0 cm) (69.7 cm) (3.3 cm) (16.5 cm) (12.7 cm) (20.0 cm) (3.5 cm) (59.7 cm)

PRODUCT DIMENSIONS

All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093
DYO, DYOV
Document # PG01-011 Revised 09/23/13 Page 2/2

Discovery iQ 30” Wide PLANNING


Single Wall Ovens GUIDE
Cutout tolerances: +1/16” (+1.6 mm), -0,
unless otherwise stated. 1 1/2” (3.8 cm) thick typical counter Recommended electrical location

29” (73.4 cm) 4“ (10.2 cm) min.


min. to between cutout
combustibles
C C
36” typical
B B
(91.4 cm)
1” (2.5 cm) min. 3/4” (1.9 cm) 3/4” (1.9 cm) Alternate
to combustible floor support platform support platform electrical
locations

4” typical toe kick

CUTOUT DIMENSIONS
A SIDE-BY-SIDE UNDER-COUNTER installation

Recommended 1 1/2” (3.8 cm) thick typical counter


electrical
location

29” (73.4 cm)


min. to
combustibles
C
36” typ. B
(91.4 cm) Recommended
electrical
B location
29” (73.4 cm)
min. to bottom C 4” typical toe kick
of cabinet door
3/4” (1.9 cm) 1” (2.5 cm) min.
3/4” (1.9 cm)
support platform to combustible floor
support platform
CUTOUT DIMENSIONS -
UNDER-COUNTER installation

1” (2.5 cm) min.


to top of
cabinet door Alternate (A) (A) (B) (B) (C) (C)
electrical 31 1/4” (79.4 cm) Standard Flush Standard Flush Standard Flush
location recommended Installation Installation Installation Installation Installation Installation
27” 7/16” to
28 3/8” to 29”
30” 31” 30” 28 1/4” 28 7/8”
(72.1 cm to
(76.2 cm) (78.7 cm) (76.2 cm) (69.7 cm to (73.3 cm)
73.7 cm)
71.8 cm)
4” typical toe kick

CUTOUT DIMENSIONS - CUTOUT DIMENSIONS


WALL installation

NOTES:
1. 24” (61.0 cm) minimum standard interior cabinet depth. 3. Two (2) Single Ovens are not approved in a stack
25 3/8” (66.0 cm) for flush installation. configuration.
2. 1/8” (3 mm) minimum clearance from appliance to
adjacent cabinet doors/drawers.

All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093