You are on page 1of 22

ROUP mfDmfom3 jjjgjgjjl) u/mgJgjL^j' jjax^ jjLuoJg^

QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.LL

Test Report
Fire Resistance of Concrete and Masonry
Construction Assemblies
ACI 216.1-97

Client: Qatar Clay Bricks Co. (Q.S.C)

Contractor: N/A Report SN #: 91657

Consultant: N/A Issue date: 25-Apr-2021

Project:** Material Quality Evaluation Job order#: CTLGQ-JQ-5-4APR21-001

Location: N/A Sampled by: Client

Sample type:** 10CM Hollow Block Sampling method: N/A

Source: QBC Tested by: Kashif

Client reference: N/A Testing Location: Main Lab

Sampling date: 31-Mar-2021 Test Environment: Lab temperature (20±5QC)

Receiving date: 31-Mar-2021 Deviation: N/A

Testing date: 20-Apr-2021 UoM: N/A

CTLG-Q reference MAR31-138 MAR31-139 MAR31-140

Received Weight (g) 12370 12485 12210

Average Length (in) 15.7 15.7 15.7

Average Width (in) 3.9 3.9 3.9

Average Height (in) 8.0 7.9 7.9

Gross Volume (in3) 489.8 483.7 483.7

Air Space Volume (in3) 130.8 129.2 129.2

Net Volume (in3) 359.0 354.5 354.5

Equivalent thickness of concrete masonry (in) 2.86 2.86 2.86

Equivalent thickness of finishes (in)’ 0.0 0.0 0.0

Equivalent thickness of concrete masonry assemblies (in) 2.86 2.86 2.86

Estimated Fire resistance rating (hrs) 1.0 1.0 1.0

Estimated Fire resistance rating - average (hrs) 1.0

'Information provided by client


Chandra Kanta Jerin Sam Kurian
Laboratory Supervisor CTUG ROUP
QOTAR
Quality Man

-‘1S+ Vjj'jy*
CO*t5TAUCTION TECHNOLOGY

RPT-0076 Rev.3
ff- LAfiOR. UP W.L L
Page 1 of 1
Ot He. • Doha • Qatar

MOE/QGOSM
Certified
ISO 17025
Accredited Laboratory IAS ACCREDITED'
Testin^taboratory
SI qualityaustria
Succeed with Quality
ISO 9001:2015
ISO 14001 : 2015
ISO 18001 : 2007
r<rrr
NRMCA
Certified
Auditors/Inspectors

"This laboratory is accredited in accordance with the recognized International Standard IS0/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system"
State of Qatar - Doha Industrial Area, Kassarat Road, R/A 41, P.O. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com
ROUP mfDmfo.3 jJj9JQMU snngJgJL^i' j_ux^ jjLuoJg^
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.L.L

Test Report
Fire Resistance of Concrete and Masonry
Construction Assemblies
A Cl 216.1-97

Client: Qatar Clay Bricks Co. (Q.S.C)

Contractor: N/A Report SN ft: 91659

Consultant: N/A Issue date: 25-Apr-2021

Project:** Material Quality Evaluation Job order ft: CTLGQ-JO-5-4APR21-001

Location: N/A Sampled by: Client

Sample type:** 15CM Hollow Block Sampling method: N/A

Source: QBC Tested by: Kashif

Client reference: N/A Testing Location: Main Lab

Sampling date: 31-Mar-2021 Test Environment: Lab temperature (20±5QC)

Receiving date: 31-Mar-2021 Deviation: N/A

Testing date: 20-Apr-2021 UoM: N/A

CTLG-Q reference MAR31-144 MAR31-145 MAR31-146

Received Weight (g) 16795 168590 16690

Average Length (in) 15.7 15.7 15.7

Average Width (in) 5.9 5.9 5.9

Average Height (in) 7.9 8.0 7.8

Gross Volume (in3) 731.8 741.0 722.5

Air Space Volume (in3) 254.7 268.8 259.6

Net Volume (in3) 477.1 472.2 462.9

Equivalent thickness of concrete masonry (in) 3.85 3.76 3.78

Equivalent thickness of finishes (in)’ 0.0 0.0 0.0

Equivalent thickness of concrete masonry assemblies (in) 3.85 3.76 3.78

Estimated Fire resistance rating (hrs) 1.6 1.5 1.5

Estimated Fire resistance rating - average (hrs) 1.5

‘Information provided by client


Chandra Kanta Jerin Sam Kurian
Laboratory Supervisor crue ROUP
CKTTAR
Quality Manager

.r.r.'

RPT-0076 Rev.3
ff- CO*eST=SUCT10N TECHNOLOGY
PW.LL
Page 1 of 1
Doha • Qatar

MOE/QGOSM
Certified
ISO 17025
Accredited Laboratory IAS; ACCREDITED-
Testin^laboratory
SI qualityaustria ISO 9001:2015
ISO 14001 : 2015 r^Tr Certified
Auditors/Inspectors
Succeed with Quality ISO 18001 : 2007 NRMCA
"This laboratory is accredited in accordance with the recognized International Standard IS0/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system"
State of Qatar - Doha Industrial Area, Kassarat Road, R/A 41, RO. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com
ROUP .fD.iD.h M9.P jJjQj'giJlJ (yuxS jjLuoJg^
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.LL

Test Report
Fire Resistance of Concrete and Masonry
Construction Assemblies
ACT 216.1-97

Client: Qatar Clay Bricks Co. (Q.S.C)

Contractor: N/A Report SN #: 91658

Consultant: N/A Issue date: 25-Apr-2021

Project:** Material Quality Evaluation Job order#: CTLGQ-JO-5-4APR21-001

Location: N/A Sampled by: Client

Sample type:" 20CM Hollow Block Sampling method: N/A

Source: QBC Tested by: Kashif

Client reference: N/A Testing Location: Main Lab

Sampling date: 31-Mar-2021 Test Environment: Lab temperature (20±5°C)

Receiving date: 31-Mar-2021 Deviation: N/A

Testing date: 20-Apr-2021 UoM: N/A

CTLG-Q reference MAR31-141 MAR31-142 MAR31-143

Received Weight (g) 17650 17605 17700

Average Length (in) 15.7 15.7 15.7

Average Width (in) 7.9 7.9 7.9

Average Height (in) 8.0 8.1 7.9

Gross Volume (in3) 992.2 1004.6 979.8

Air Space Volume (in3) 457.6 457.6 457.6

Net Volume (in3) 534.6 547.0 522.2

Equivalent thickness of concrete masonry (in) 4.26 4.30 4.21

Equivalent thickness of finishes (in)* 0.0 0.0 0.0

Equivalent thickness of concrete masonry assemblies (in) 4.26 4.30 4.21

Estimated Fire resistance rating (hrs) 2.0 2.1 2.0

Estimated Fire resistance rating - average (hrs) 2.0

•Information provided by client


Chandra Kanta Jerin Sam Kurian
Laboratory Supervisor crita ROUP
QOTAR
-1^
CO*BT^UCTlON TECHNOLOGY
RPT-0076 Rev.3
ff- LABOR PWL L
Page 1 of 1
CR WW Doha • Qatar

MOE/QGOSM
Certified
ISO 17025
Accreditee Laboratory IAS ACCREDITED’
Testin^Laboratcry
SI qualityaustria ISO 9001:2015
ISO 14001 : 2015 r^Tr Certified
Auditors/Inspectors
Succeed with Quality ISO 18001 : 2007 NRMCA
"This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.
This accreditation demonstrates technical competence fora defined scope and the operation of a laboratory quality management system"
State of Qatar - Doha Industrial Area, Kassarat Road, R/A 41, P.O. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctigroupqatar.com | Web: ctlgroupqatar.com
ROUP mfomfo.D vQir1 jJjQjgiJU uiivqJO-iix^ >LloJ9^
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.LL
Test Report
Compressive Strength of Masonry Units
BS 6073-1:1981 Appendix B
CTLG-Q Client: Qatar Clay Bricks Co.
Contractor: N/A Report SN #: 91656
Consultant: N/A Issue date: 25-Apr-2021
Project:* Material Quality Evaluation Job order #: CTLGQ-JO-5-4APR21 -001
Location: N/A Sampled by: Client
Sample type:* 10CM Solid Block Sampling method: N/A
Source/Supplier:* QBC Tested by: Kashit
Client reference:* 10 CM Soild Block Testing location: Main Lab
Production date: N/A Test environment: Lab temperature (20±5°C)
Receiving date: 31-Mar-2021 Deviation: Specimen tested by using fiber board
Testing date: 17-Apr-2021 UoM: N/A

CTLG-Q reference MAR31-132 MAR31-133 MAR31-134 MAR31-135 MAR31-136 MAR31-137


Age (days) N/A
Method of surface preparation Without capping, fiber board
Method of conditioning Air dry
Description of the measuring device Vernier Caliper
Way of measuring Two measurements taken near the edges of each specimen
Sample Weight (g) 17430 17380 17485 17675 17460 17395
Average length (mm) 400.0 400.0 400.0 400.0 400.0 400.0
Average width (mm) 100.0 100.0 100.0 100.0 100.0 100.0
Average height (mm) 200.0 200.0 200.0 200.0 200.0 200.0
Average face shell thickness (mm) N/A N/A N/A N/A N/A N/A
Average web thickness (mm) N/A N/A N/A N/A N/A N/A
Net area (mm2) 40000 40000 40000 40000 40000 40000
Gross area (mm2) 40000 40000 40000 40000 40000 40000
Failure load (N) 824800 815100 802800 741800 691100 847600
Normalised Compressive Strength (MPa) 20.6 20.4 20.1 18.5 17.3 21.2

Average Normalised Compressive Strength (MPa) 19.7


QCS 2014, Section: 13-Part 04-Table 4.5
QCS 2014, Section: 13-Part 04-Table 4.6
Minimum Compressive Strength (N/mm2)
Classes
Average of 3 Blocks Lowest Individual Block Block Dimensions and Wall and Web Thicknesses
1 7.0 5.6 Nominal Size Work size Min. Thickness (mm)
2 10.4 8.3 (mm) (mm) Wall Web
3 17.4 14.0 400x200x100 390x190x100 19 19
4 14.0 11.2 400x200x150 390x190x150 25 25
5 4.0 3.6 400x200x200 390x190x200 32 30

•Information provided by client

Note: -
• This results apply to the sample as received.
• This document may not be reproduced except in its entirety. The result pertains only to the particular items tested.

Chandra Kanta Jerin Sam Kurian


Laborato^Ja upervisor cri)GROUP Q67AR
Quality Manarfer

RPT-0080 Rev fW5- ...f.J -‘is* v* 'i*jC


30«5T?*U£ iTDiW ECdNOLOGY
LAPORATCRES GROUP W.L L
■age 1 of 1

Of He. *S00* PC. U2!2 • Doha - Oatar

MOE/QGOSM
Certified
ISO 17025
Accredited Laboratory IAS ACCREDITED’
Testing Laboratory
SI qualityaustria ISO 9001:2015
ISO 14001 : 2015 ^Tr Certified
Auditors/Inspectors
Succeed with Quality ISO 18001 : 2007
NRMCA
"This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system”
State of Qatar - Doha Industrial Area. Kassarat Road. R/A 41, P.0. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com
.fO.fO.D v_jg>n jjjgjgjjll oingJgi^’j ji-uxig^
ROUP
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.LL
Test Report
Fire Resistance of Concrete and Masonry
Construction Assemblies
ACT 216.1-97
CTLG-Q Client: Qatar Clay Bricks Co. (Q.S.C)

Contractor: N/A Report SN #: 92885

Consultant: N/A Issue date: 8-May-2021

Project:** Material Quality Evaluation Job order #: CTLGQ-JO-5-4MAY21 -001

Location: N/A Sampled by: Client

Sample type:** Concrete Solid Block 8" Sampling method: N/A

Supplier: N/A Tested by: Kashif

Client reference: N/A Testing Location: Main Lab

Sampling date: 2-May-2021 Test environment: Lab temperature (20±5°C)

Receiving date: 2-May-2021 Deviation: N/A

Testing date: 5-May-2021 UoM: N/A

CTLG-Q reference MAY02-065 MAY02-066 MAY02-067

Received Weight (g) 34230 34480 34840

Average Length (in) 15.7 15.7 15.7

Average Width (in) 7.9 7.9 7.9

Average Height (in) 7.9 7.8 7.9

Equivalent thickness of concrete masonry (in) 7.90 7.90 7.90

Equivalent thickness of finishes (in)* 0.0 0.0 0.0

Equivalent thickness of concrete masonry assemblies (in) 7.90 7.90 7.90

Estimated Fire resistance rating (hrs) 4.00 4.00 4.00

Estimated Fire resistance rating - average (hrs) 4.0

'Information provided by client


Note:-
• This results apply to the sample as received.
• This document may not be reproduced except in its entirety. The result pertain only to the particular items tested

Chandra Kanta Jerin Sam Kurian

Laboratory Supervisor cnJGROUP OSTAR


Quality Mana

c -‘it* ajJ-IX1' ^
CONSTRUCTION TECHNOLOGY
ff LACCRA-hCRIES GROUP W L L
RPT-0076 Rev.3 c* • oof* • o«« Page 1 of 1

MOE/QGOSM ISO 17025


Jiajl Accredited Laboratory IAS ACCREDITED'
Testin^Ubcratory
(S qualityaustria
ISO 9001:2015
ISO 14001 : 2015 ^Tr Certified
Auditors/Inspectors
Certified Succeed with Quality ISO 18001 : 2007
NRMCA
'This laboratory is accredited in accordance with the recognized International Standard 1S0/IEC 17025:2017.
This accreditation demonstrates technical competence fora defined scope and the operation of a laboratory quality management system”
State of Qatar - Doha Industrial Area, Kassarat Road, R/A 41, P.O. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com
ROUP -fO-fO.ii yjgjn jjjgj’gjjL) oiiigJgJL^j jjLuxig^
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.L.L
Test Report
Fire Resistance of Concrete and Masonry
Construction Assemblies
ACI 216.1-97

CTLG-Q Client: Qatar Clay Bricks Co. (Q.S.C)

Contractor: N/A Report SN #: 92886

Consultant: N/A Issue date: 8-May-2021

Project:** Material Quality Evaluation Job order#: CTLGQ-JO-5-4MAY21-001

Location: N/A Sampled by: Client

Sample type:" Concrete Solid Block 6" Sampling method: N/A

Supplier: N/A Tested by: Kashif

Client reference: N/A Testing Location: Main Lab

Sampling date: 2-May-2021 Test environment: Lab temperature (20±5°C)

Receiving date: 2-May-2021 Deviation: N/A

Testing date: 5-May-2021 UoM: N/A

CTLG-Q reference MAY02-068 MAY02-069 MAY02-070

Received Weight (g) 25825 26055 25795

Average Length (in) 15.7 15.7 15.7

Average Width (in) 5.9 5.9 5.9

Average Height (in) 7.7 8.0 7.8

Equivalent thickness of concrete masonry (in) 5.90 5.90 5.90

Equivalent thickness of finishes (in)* 0.0 0.0 0.0

Equivalent thickness of concrete masonry assemblies (in) 5.90 5.90 5.90

Estimated Fire resistance rating (hrs) 3.60 3.60 3.60

Estimated Fire resistance rating - average (hrs) 3.6

■Information provided by client


Note:-
• This results apply to the sample as received.
• This document may not be reproduced except in its entirety. The result pertain only to the particular items tested.
Chandra Kanta Jerin Sam Kurian
Laboratory Supervisor CU)GROUP Quality Mana
OSTAR
-SJ*

ff- CONSTRUCTION TECHNOLOGY


LAEORA-hCRIES GROUP W.L L
RPT-0076 Rev.3 Page 1 of 1

0 MOE/QGOSM
Certified
ISO 17025
Accredited Laboratory
ACCREDITED'
Testing laboratory
U -651
® qualityaustria
Succeed with Quality
ISO 9001:2015
ISO 14001 : 2015
ISO 18001 : 2007
r«rc
NRMCA
Certified
Auditors/Inspectors

"This laboratory is accredited in accordance with the recognized International Standard IS0/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system"
State of Qatar - Doha Industrial Area, Kassarat Road, R/A41, P.O. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctigroupqatar.com | Web: ctlgroupqatar.com
.fO.fO.i <wjg>n jjjgjgjjll v_niigJgjL£i j-ux^ jLuJjg^
ROUP
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.L.L

Test Report
Compressive Stremzth of Masonry Units
BS EN 772-1:2011+41:2015*, 772-16:2011.772-20:2000

CTLG-Q Client: Qatar Clay Bricks Co. (Q.S.C)


Owner: N/A
Contractor: N/A
Consultant: N/A
Project: N/A Report SN #: 95953
Location: N/A Issue date: 9-Jun-2021
Sample type:** Solid Block 8" Job order #: CTLGQ-JO-5-10May21 -001
Source: N/A Sampled by: CTL Group Qatar
INR reference: N/A Sampling method: N/A
Casting date: N/A Tested by: Kashif
Sampling date: 9-May-2021 Testing Location: Main Lab
Receiving date: 9-May-2021 Test Environment: Lab Temperature (20±5°C)
Testing Date: 8-Jun-2021 Deviation: Not Available
CTLG-Q reference: MAY09-111-116 UoM: Not Available

CTLG-Q reference MAY09-111 MAY09-112 MAY09-113 MAY09-114 MAY09-115 MAY09-116


Age (days) N/A
Method of surface preparation Surface Grinding
Method of conditioning Air Dry
Description of the measuring device Vernier Caliper
Way of measuring Two measurements taken near the edges of each specimen
Sample Weight (g) 34510 35145 34395 34520 35150 34390
Average length (mm) 400.0 400.0 400.0 399.0 400.0 400.0
Average width (mm) 200.0 200.0 200.0 200.0 200.0 200.0
Average height (mm) 199.0 201.0 200.0 202.0 200.0 201.0
Average face shell thickness (mm) N/A N/A N/A N/A N/A N/A
Average web thickness (mm) N/A N/A N/A N/A N/A N/A
Net area (mm2) 80000 80000 80000 79800 80000 80000
Gross area (mm*) 80000 80000 80000 79800 80000 80000
Failure load (N) 2428400 2199100 2099500 2064100 2184100 2091100
Compressive Strength - Net area (MPa) 30.4 27.5 26.2 25.9 27.3 26.1
Compressive Strength - Gross area (MPa) 30.4 27.5 26.2 25.9 27.3 26.1
Conditioning factor 1.00
Shape factor 1.15
Normalised Compressive Strength (MPa) 34.9 31.6 30.2 29.7 31.4 30.1

Average Normalised Compressive Strength


31.3
(MPa)
QCS 2014, Section: 13-Part 04-Table 4.5
QCS 2014, Section: 13-Part 04-Table 4.6
Minimum Compressive Strength (N/mm*)
Classes Block Dimensions and Wall and Web Thicknesses
Average of 3 Blocks Lowest Individual Block
1 7.0 5.6 Nominal Size Work size Min. Thickness (mm)
2 10.4 8.3 (mm) (mm) Wall Web
3 17.4 14.0 400x200x100 390x190x100 19 19
4 14.0 11.2 400x200x150 390x190x150 25 25
5 4.0 3.6 400x200x200 390x190x200 32 32
•ISO 17025 Accredited Test
"Information provided by client
Note:-
• This results apply to the sample as received.
• The sample tested as per QCS 2014 requirement.
• This document may not be reproduced except in its entirety The result pertain only to the particular items tested.

Chandra Kanta Jerin Sam Kuri;


Laboratoc&Supervisor ctOg ROUP
OCTAR

RPT-0080 "Page 1 of 1
LAf ORATCRES GROUP W L L
CT Hi. AC, Ro. U21Z.Doha-0*Uf

MOE/QGOSM ISO 17025


Accredited Laboratory
AS ACCREDITED'
Tatin^laboratory
SI qualityaustria ISO 9001:2015
ISO 14001 : 2015 ^Tr Certified
Auditors/Inspectors
Certified Succeed with Quality ISO 18001 : 2007
NRMCA
"This laboratory is accredited in accordance with the recognized International Standard 1S0/IEC 17025:2017.
This accreditation demonstrates technical competence fora defined scope and the operation of a laboratory quality management system"
State of Qatar- Doha Industrial Area, Kassarat Road, R/A 41, P.O. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com
ROUP mfomfDmn ^jg.p jjjgjgjjU enngJgJL^)' Ojjlx^ jJLuoJg^
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.L.L

Test Report
Compressive Strength of Masonry Units
BS EN 772-1:2»11+A 1:2015 % 772-16:2011, 772-20:2000
CTLG-Q Client: Qatar Clay Bricks Co. (Q.S.C)
Owner: N/A
Contractor: N/A
Consultant: N/A
Project: N/A Report SN #: 94954
Location: N/A Issue date: 9-Jun-2021
Sample type:** Solid Block 6" Job order #: CTLGQ-JO-5-10May21-001
Source: N/A Sampled by: CTL Group Qatar
INR reference: N/A Sampling method: N/A
Casting date: N/A Tested by: Kashif
Sampling date: 9-May-2021 Testing Location: Main Lab
Receiving date: 9-May-2021 Test Environment: Lab Temperature (20±5°C)
Testing Date: 8-Jun-2021 Deviation: Not Available
CTLG-Q reference: MAY09-117-122 UoM: Not Available

CTLG-Q reference MAY09-117 MAY09-118 MAY09-119 MAY09-120 MAY09-121 MAY09-122


Age (days) N/A
Method of surface preparation Surface Grinding
Method of conditioning Air Dry
Description of the measuring device Vernier Caliper
Way of measuring Two measurements taken near the edges of each specimen
Sample Weight (g) 29050 28845 27900 29120 27950 28975
Average length (mm) 400.0 400.0 400.0 400.0 399.5 400.0
Average width (mm) 150.0 150.0 150.0 149.5 150.0 150.0
Average height (mm) 199.0 200.0 202.0 200.0 202.0 199.0
Average face shell thickness (mm) N/A N/A N/A N/A N/A N/A
Average web thickness (mm) N/A N/A N/A N/A N/A N/A

Net area (mm2) 60000 60000 60000 59800 59925 60000

Gross area (mm2) 60000 60000 60000 59800 59925 60000


Failure load (N) 1828400 1499100 1699500 1561100 1487500 1691300
Compressive Strength - Net area (MPa) 30.5 25.0 28.3 26.1 24.8 28.2
Compressive Strength - Gross area (MPa) 30.5 25.0 28.3 26.1 24.8 28.2
Conditioning factor 1.00
Shape factor 1.25
Normalised Compressive Strength (MPa) 38.1 31.2 35.4 32.6 31.0 | 35.2
Average Normalised Compressive Strength
33.9
(MPa)
QCS 2014, Section: 13-Part 04-Table 4.5
QCS 2014, Section: 13-Part 04-Table 4.6
Minimum Compressive Strength (N/mm2)
Classes Block Dimensions and Wall and Web Thicknesses
Average of 3 Blocks Lowest Individual Block
1 7.0 5.6 Nominal Size Work size Min. Thickness (mm)
2 10.4 8.3 (mm) (mm) Wall Web
3 17.4 14.0 400x200x100 390x190x100 19 19
4 14.0 11.2 400x200x150 390x190x150 25 25
5 4.0 3.6 400x200x200 390x190x200 32 32
•ISO 17025 Accredited Test
"Information provided by client
Note -
• This results apply to the sample as received.
• The sample tested as per QCS 2014 requirement.
• This document may not be reproduced except in its entirety The result pertain only to the particular items tested

Chandra Kanta Jerin Sam Kuril


Laboratocy^Supervisor ctPg ROUP
OCTAR

RPT-0080 R
ft- CO<ST5BUCn ^■SySfoLOoT "Page 1 of 1
LA60RATCRIES GROUP W L L
CF Ni. P<T l-!Zir-Qoh*-G»ur

MOE/QGOSM
Certified
ISO 17025
Accredited Laboratory IAS ACCREDITED'
Testing Laboratory
SI qualityaustria ISO 9001:2015
ISO 14001 : 2015 ^Tr Certified
Auditors/Inspectors
TL-651 Succeed with Quality ISO 18001 : 2007
NRMCA
"This laboratory is accredited in accordance with the recognized International Standard ISO/lEC 17025:2017.
This accreditation demonstrates technical competence fora defined scope and the operation of a laboratory quality management system"
State of Qatar - Doha Industrial Area, Kassarat Road, R/A 41, P.O. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com
CTL^Group .^.rO.D jgja jjjgjgjjll e/tagJgjllj jjLuxig^
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.L.L
Test Report
Compressive Strength of Masonry Units
BS EN yyi-iaOll+Al^OlS*. 772-16:2011, 772-20:2000
Client: Qatar Clay Bricks
Contractor: N/A
Consultant: N/A Report SN #: 62629
Project:** Evaluation of Material Issue date: 18-Jul-2020
Location:** Industrial Area. Street # 41 (Masa-2) Job order #: CTLGQ-JO-5-28JUN20-001

Sample type:'* Insulation Block 20CM - Blue Sampled by: CTL Group Qatar

Source:** Industrial Area, Street # 41 (Masa-2) Sampling method: ASTM D3665


Client reference: N/A Tested by: Kashif
Production date:” 15-Jun-2020 Test Environment: Lab Temperature (20±5°C)
Receiving date: 24-Jun-2020 Deviation: Specimen tested by using fiber board
Testing date: 1 -Jul-2020 UoM: N/A

Specimen reference JUN24-218 JUN24-219 JUN24-220 JUN24-221 JUN24-222 JUN24-223

Age (days) 16
Method of surface preparation Without capping, fiber board
Method of conditioning Air Dry
Description of the measuring device Vernier Caliper
Way of measuring Two measurements taken near the edges of each specimen
Sample Weight (g) 17480 18015 17390 17600 17490 17570
Average Length (mm) 399.0 400.0 399.0 398.0 396.0 396.0
Average Width (mm) 201.0 201.0 200.0 201.0 201.0 201.0
Average Height (mm) 199.0 200.0 200.0 198.0 199.0 198.0
Foam Area (mm2) 29874 29601 29577 29477 29775 29799
Air Space Area (mm2) 6215 6177 6248 6231 5720 6221
Net Area (mm2) 44110 44622 43976 44289 44101 43577
Gross Area (mm2) 80199 80400 79800 79998 79596 79596
Failure load (N) 476900 599500 498300 467500 548200 453200
Compressive Strength - Net area (MPa) 10.8 13.4 11.3 10.6 12.4 10.4

Compressive Strength - Gross area (MPa) 5.9 7.5 6.2 5.8 6.9 5.7

Conditioning factor 1.00


Shape factor 1.15
Normalised Compressive Strength (MPa) 6.8 8.6 7.2 6.7 7.9 6.5

Average Normalised Compressive Strength (MPa) 7.3

QCS 2014, Section: 13-Part 04-Table 4.5


QCS 2014, Section: 13-Part 04-Table 4.6
Minimum Compressive Strength (N/mm2)
Classes
Average of 3 Blocks Lowest Individual Block Block Dimensions and Wall and Web Thicknesses

1 7.0 5.6 Nominal Size Work size Min. Thickness (mm)

2 10.4 8.3 (mm) (mm) Wall Web

3 17.4 14.0 400x200x100 390x190x100 19 19


4 14.0 11.2 400x200x150 390x190x150 25 25

5 4.0 3.6 400x200x200 390x190x200 32 30


'ISO 17025 Accredited Test
"Information provided by client
Note:- This document may not be reproduced except in its entirety. The result pertain only to the particular items tested.
"Above mention standard is withdrawn and replace by BS EN 772-2 and BS EN 771-3
Chandra Kanta .ng. Mahmoud Al Shboul
Laboratory Supervisor C~ f.'f ' ) Protects Manager
-r ' ■s

C.T.L. Gr>: j? I.L.L.


<;
CP tJn 6900?
P. O. Bex: 1421/ - DoM - C.v -r

RPT-0080 Rev.05 End of report Page 1 of 1

MOE/QGOSM ISO 17025


Acaedited Laboratory AS ACCREDITED'
TestinK Laboratwy
E qualityaustria ISO 9001 : 2015
ISO 14001 : 2015 r<TTr Certified
Auditors/Inspectors
Certified Tl-ttl Succeed with Quality ISO 18001 : 2007 NRMCA
"This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system"
State of Qatar - Doha Industrial Area. Kassarat Road, R/A 41. P.0. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com
-fO-fO.h gj3 jjjgjgjjJJ v-nngJgi^j jjLuxig^
CTL)Group
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.LL
Test Report
Thermal Properties of Concrete & Masonry Systems
AC1 122
CTLG-Q Client: Qatar Clay Bricks

Contractor: N/A

Consultant: N/A Report SN # : 62631

Project:* Evaluation of Materials Issue Date: 18-Jul-2020

Location:* Industrial Area. Street # 41 Job Order # : CTLGQ-JO-5-28JUN20-001

Sample type:* Insulation Block 20CM - Blue Sampled by: Client

Supplier/Source: N/A Sampling Method: N/A

Production Date:* 15-Jun-2020 Tested By: Kashif

Receiving date: 24-Jun-2020 Test Environment: Lab Temperature (20±5°C)


-
Testing date: 30-Jun-2020 Deviation: N/A

CTLG-Q reference: JUN24-227 to 229 UoM: N/A

Property Value

Thermal conductance - K value of masonry concrete W/(m K)*‘ 0.860 0.860 0.860

Thermal conductivity - K value of EPS W/(m K)*’* 0.037 0.037 0.037

Thermal resistivity - R value of section A (m2 K/W) **•* 0.035 0.035 0.037

Thermal resistivity - R value of section B (m2 K/W) *•* * N/A N/A N/A

Thermal resistivity - R value of section C (m2 K/W)*“* 0.043 0.047 0.044

Thermal resistivity - R value of section D (m2 K/W)**** 2.027 2.000 2.000

Thermal resistivity - R value of section E (m2 K/W)**** 0.053 0.052 0.052

Total thermal resistance - R value of insulated CMU (m2 K/W) 3.055 3.031 3.031

Thermal transmittance - U value of insulated CMU (W/m2 K) ***** 0.327 0.330 0.330

‘Information provided by client


"Value stated in ACI 122R-02 Chapter 2, Table 2.1
‘‘‘Value stated in ASTM C177-13, Table 1
‘‘"Based on existing thickness of each section (as shown in adjacent photo)
Computed U value excludes any thermal bridges, air gaps, fixings, mortar/plaster & moisture content
Note: -This document may not be reproduced except in its entirety. The result pertain only to the particular items tested.
Chandra Kanta Eng. Mahmoud Al Shboul
Laboratory Supen/isor UUF- P/o/ects Manager

C.7.L. Grc jr. /.l.l.


OR Nr.
P. O. Box: ■x 1 ^ - Ooi\M - c.itnr _

RPT-0138 Rev.1 End of report Page 1 of 1

MOE/QGOSM
Certified
ISO 17025
Accredited Laboratory
IAS
AS2iD'
Tl-651
E qualityaustria
Succeed with Quality
ISO 9001 : 2015
ISO 14001 : 2015
ISO 18001 : 2007
r«rr
NRMCA
Certified
Auditors/Inspectors

"This laboratory is accredited in accordance with the recognized International Standard 1S0/1EC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system"
State of Qatar - Doha Industrial Area. Kassarat Road, R/A 41, P.0. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com
CTL)Group m(omfom3 v_jgj3 jjjgjgjjU vjxngJgJL^j jJLuoJg^
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.LL
Test Report
Fire Resistance of Concrete and Masonry
Construction Assemblies
A Cl 216.1-97

Client: Qatar Clay Bricks

Contractor: N/A Report SN #: 62630

Consultant: N/A Issue date: 18-Jul-2020

Project:** Evaluation of Materials Job order #: CTLGQ-JO-5-28JUN20-001

Location:** Industrial Area, Street # 52 Sampled by: Client

Sample type:** Insulation Block 20CM - Blue Sampling method: N/A

Source: N/A Tested by: Kashif

Client reference: N/A Testing Location: Main Lab

Production date: 15-Jun-2020 Test Environment: Lab Temperature (20±5°C)

Receiving date: 24-Jun-2020 Deviation: N/A

Testing date: 30-Jun-2020 UoM: N/A

CTLG-Q reference JUN24-224 JUN24-225 JUN24-226

Received Weight (g) 17355 17910 1755

Average Length (in) 15.6 15.6 15.7

Average Width (in) 8.0 8.1 7.9

Average Height (in) 7.8 7.8 7.9

Gross Volume (in3) 973.4 985.6 979.8

Air Space Volume (in3) 346.3 334.6 357.1

Net Volume (in3) 627.1 651.0 622.7

Equivalent thickness of concrete masonry (in) 5.15 5.35 5.02

Equivalent thickness of finishes (in)* 0.0 0.0 0.0

Equivalent thickness of concrete masonry assemblies (in) 5.15 5.35 5.02

Estimated Fire resistance rating (hrs) 2.8 2.9 3.1

Estimated Fire resistance rating - average (hrs) 2.9

'Information provided by client


Chandra Kanta lahrrpud Al Shboul
Laboratory Supervisor ojeens Manager
CLV:v ql-

C.T.L. Grc Jf ;.l.l.


CP. Ur PPM?
p. Q. Box:

RPT-0076 Rev.3 End of report Page 1 of 1

MOE/QGOSM ISO 17025


Accredited Laboratory
IAS
ASSffiD" ® qualityaustria ISO 9001 : 2015
ISO 14001 : 2015 r<TTr Certified
Auditors/Inspectors
Certified TL-651 Succeed with Quafity ISO 18001 : 2007 NRMCA
"This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system”
State of Qatar - Doha Industrial Area, Kassarat Road, R/A 41. RO. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com
CTLJCjROUP mfDmfD.ii vjgja jjjgj'gjjlJ vJiagJgi^) \j-ujS jiuoigS
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.LL
Test Report
Determination Water Absorption of Precast Concrete Pavinu Block
CML 09-97

CTLG-Q Client: Qatar Clay Bricks


Contractor: N/A Report SN. #: 62632
Consultant: N/A Issue date: 18-Jul-2020
Project:** Evaluation of Materials Job order # : CTLGQ-JO-5-28JUN20-001
Location:** Industrial Area, Street # 52 Sampled by: Client
Sample type:** Insulation Block (400x250x200mm) - White Sampling method: N/A
Source/Supplier: N/A Tested by: Kashif
Client reference: N/A Testing Location: Main Lab
Production date: 15-Jun-2020 Test Environment: Lab Temperature (20±5°C)
Receiving date: 24-Jun-2020 Deviation: Specimen tested as saw cut
Testing date: 1-Jul-2020 to 5-Jul-2020 UoM: N/A

CTLGQ reference Receiving Weight (g) Dry Weight (g) SSD Weight (g) Water Absorption (%)

JUN24-230 17590 6831.7 7275.9 6.1

JUN24-231 17625 6996.7 7430.4 5.8

JUN24-232 18105 7373.8 7780.2 5.2

Average Water Absorption (%) 5.7

QCS 2014 Section : 13 Part: 04


Water Absorption (%)
Average of 3 Blocks individual Block
Maximum 7% Maximum 7.5%

‘Information provided by client


Note:- This document may not be reproduced except in its entirety. The result pertain only to the particular items tested.

Chandra Kama Eng-Wtahmoud Al Shboul


Laboratory Supervisor /Projects Manager
C~ i'C .^UP
•*T1
C.7.L. Grcj,v. ’7.L.L.
CR Do. f-PfifiP.
P. O. Bl«: :-l-• 1- C jiia • Qai.ir

RPT-0203 Rev.1 End of report Page 1 of 1

MOE/QGOSM ISO 17025


Accredited Laboratory AS ACCREDITED'
testing Laboratory
® qualityaustria ISO 9001 : 2015
ISO 14001 : 2015 ^Tr Certified
Auditors/Inspectors
Certified Tl-65t Succeed with Quality ISO 18001 : 2007 NRMCA
"This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system"
State of Qatar - Doha Industrial Area, Kassarat Road, R/A 41, P.0. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com
CTL)Group v-jgjn jjjgjgpli vjugJgJL^J j-ui^ jjLuoJg^i
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.LL
Test Report
Compressive Strength of Masonry Units
BS I-N 772-1:2011+A 1:2015:i:. 772-16:2011.772-20:2000

Client: Qatar Clay Bricks


Contractor: N/A
Consultant: N/A Report SN #: 62596
Project:** Evaluation of Material Issue date: 18-Jul-2020
Location:** Industrial Area. Street # 41 (Masa-2) Job order #: CTLGQ-JO-5-5JUL20-001

Sample type:” Insulation Block (400x250x200mm) - White Sampled by: CTL Group Qatar

Source:** Industrial Area, Street # 41 (Masa-2) Sampling method: ASTM D3665

Client reference: N/A Tested by: Kashif

Production date:” 14-Jun-2020 Test Environment: Lab Temperature (20±5°C)

Receiving date: 4-Jul-2020 Deviation: Specimen tested by using fiber board

Testing date: 6-Jul-2020 UoM: N/A

Specimen reference JUL04-090 JUL04-091 JUL04-092 JUL04-093 JUL04-094 JUL04-095

Age (days) 22
Method of surface preparation Without capping, fiber board

Method of conditioning Air Dry


Description of the measuring device Vernier Caliper
Way of measuring Two measurements taken near the edges of each specimen
Sample Weight (g) 21630 21095 21380 20925 21205 20445
Average Length (mm) 396.0 395.0 396.0 396.0 396.0 395.0
Average Width (mm) 252.0 250.0 252.0 251.0 252.0 251.0
Average Height (mm) 201.0 199.0 200.0 199.0 200.0 199.0
Foam Area (mm2) 29874 29601 29577 29477 29775 29799
Air Space Area (mm2) 6215 6177 6248 6231 5720 6221
Net Area (mm2) 63703 62972 63968 63687 64297 63126
Gross Area (mm2) 99792 98750 99792 99396 99792 99145
Failure load (N) 754100 594900 832700 674500 623700 575400
Compressive Strength - Net area (MPa) 11.8 9.4 13.0 10.6 9.7 9.1
Compressive Strength - Gross area (MPa) 7.6 6.0 8.3 6.8 6.3 5.8

Conditioning factor 1.00


Shape factor 1.10
Normalised Compressive Strength (MPa) 8.3 6.6 9.2 7.5 6.9 6.4

Average Normalised Compressive Strength (MPa) 7.5

QCS 2014, Section: 13-Part 04-Table 4.5


QCS 2014, Section: 13-Part 04-Table 4.6
Minimum Compressive Strength (N/mm2)
Classes
Average of 3 Blocks Lowest Individual Block Block Dimensions and Wall and Web Thicknesses

1 7.0 5.6 Nominal Size Work size Min. Thickness (mm)

2 10.4 8.3 (mm) (mm) Wall Web

3 17.4 14.0 400x200x100 390x190x100 19 19


4 14.0 11.2 400x200x150 390x190x150 25 25
5 4.0 3.6 400x200x200 390x190x200 32 30

’ISO 17025 Accredited Test


’’Information provided by client
Note:- This document may not be reproduced except in its entirety. The result pertain only to the particular items tested.
’’Above mention standard is withdrawn and replace by BS EN 772-2 and BS EN 771-3
Chandra Kanta Eng. Manmoud Al Shboul
Laboratory Supervisor C'LlCir.oU' Pro/e/ts Manager
: JV '''
C.T.L. Grcjj. w.L.L.
CR No f-fPOP
p. O. Box: • Oaii.T - C.-Pr___

End of report Page 1 of 1

MOE/QGOSM ISO 17025


Accredited Laboratory
HAS ACCREDITED'
TestingLaboratoiy qualityaustria
ISO 9001 : 2015
ISO 14001 : 2015 ^Tr Certified
Auditors/Inspectors
Certified Succeed with Quality ISO 18001 : 2007 NRMCA
"This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system
State of Qatar - Doha Industrial Area, Kassarat Road. R/A 41, P.0. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com
CTL)Group .,£>..,0.:] jJjQJ9jJU v-nagJQiS) i>iixS jjLuajg£
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.LL
Test Report
Thermal Properties of Concrete & Masonry Systems
ACI 122
CTLG-Q Client: Qatar Clay Bricks

Contractor: N/A

Consultant: N/A Report SN # : 62597

Project:* Evaluation of Materials Issue Date: 18-Jul-2020

Location:* Industrial Area, Street # 41 Job Order # : CTLGQ-JO-5-5JUL20-001

Sample type:* Insulation Block (400x250x200mm) - White Sampled by: Client

Supplier/Source: N/A Sampling Method: N/A

Production Date:* 14-Jun-2020 Tested By: Kashif

Receiving date: 4-Jul-2020 Test Environment: Lab Temperature (20±5°C)

Testing date: 4-Jul-2020 Deviation: N/A

CTLG-Q reference: ju!04-099 to 101 UoM: N/A

Property Value

Thermal conductance - K value of masonry concrete W/(m K)’* 0.860 0.860 0.860

Thermal conductivity - K value of EPS W/(m K)“* 0.037 0.037 0.037

Thermal resistivity - R value of section A (m2 K/W)**** 0.065 0.065 0.066

Thermal resistivity - R value of section B (m2 K/W)**** N/A N/A N/A

Thermal resistivity - R value of section C (m2 K/W)**** 0.077 0.078 0.078

Thermal resistivity - R value of section D (m2 K/W)**** 3.000 2.892 2.892

Total thermal resistance - R value of insulated CMU (m2 K/W) 4.039 3.932 3.933

Thermal transmittance - U value of insulated CMU (W/m2 K) ***** 0.248 0.254 0.254

'Information provided by client


"Value stated in ACI 122R-02 Chapter 2, Table 2.1
"'Value stated in ASTM C177-13. Table 1
'"'Based on existing thickness of each section (as shown in adjacent photo)
""'Computed U value excludes any thermal bridges, air gaps, fixings, mortar/plaster & moisture content
Note: -This document may not be reproduced except in its entirety. The result pertain only to the particular items tested.
Chandra Kanta Eng. Mahmoud Al Shboul
Laboratory Supervisor Projects Manager
t. ..our
■ '• A-’*

C.T.u . G r c u •.
/.L.L.
cr up. fcono?’
. Doha • Qatar
p. o. -—

RPT-0138 Rev.1 End of report Page 1 of 1

MOE/QGOSM ISO 17025


AS ACCREDITED'
testing laboratory
E qualityaustria ISO 9001 : 2015
ISO 14001 : 2015 r<TTc Certified
Auditors/Inspectors
Certified Accredited Latxxatory 11-651 Succeed with Quality ISO 18001 : 2007 NRMCA
"This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system
State of Qatar - Doha Industrial Area, Kassarat Road. R/A 41, R0. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 1 Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com
CTLIGroup -fO-fD.h igjiv jjjgjgjjJJ vT/ogJgJL^j j_ui^ jJLlojgS
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.L.L.
Test Report
Fire Resistance of Concrete and Masonry
Construction Assemblies
AC'l 216.1-97

Client: Qatar Clay Bricks

Contractor: N/A Report SN #: 62598

Consultant: N/A Issue date: 18-Jul-2020

Project:** Evaluation of Materials Job order#: CTLGQ-JO-5-5JUL20-001

Location:** Industrial Area, Street # 52 Sampled by: Client

Sample type:” Insulation Block (400x250x200mm) - White Sampling method: N/A

Source: N/A Tested by: Kashif

Client reference: N/A Testing Location: Main Lab

Production date: 14-Jun-2020 Test Environment: Lab Temperature (20±5°C)

Receiving date: 4-Jul-2020 Deviation: N/A

Testing date: 4-Jul-2020 UoM: N/A

CTLG-Q reference JUL04-096 JUL04-097 JUL04-098

Received Weight (g) 21265 20955 21610

Average Length (in) 15.6 15.7 15.7

Average Width (in) 9.9 9.8 9.9

Average Height (in) 7.9 7.8 7.9

Gross Volume (in3) 1220.1 1200.1 1227.9

Air Space Volume (in3) 570.0 565.0 563.4

Net Volume (in3) 650.1 635.1 664.5

Equivalent thickness of concrete masonry (in) 5.27 5.19 5.36

Equivalent thickness of finishes (in)* 0.0 0.0 0.0

Equivalent thickness of concrete masonry assemblies (in) 5.27 5.19 5.36

Estimated Fire resistance rating (hrs) 3.0 3.1 3.0

Estimated Fire resistance rating - average (hrs) 3.0

•Information provided by client


Chandra Kanta Eng. Mahmfcud Al Shboul
Laboratory Supervisor Projat/s Manager
C~ L‘;C.:._>L:r

C.T.L. Grc jj. ' i.i.L.


CR Ho. M)P08
P. O. Bo*: 14*12 - Coha - Qatar___

RPT-0076 Rev.3 End of report Page 1 of 1

MOE/QGOSM gj ISO 17025


AS ACCREDITED'
Testing Laboratory
E qualityaustria ISO 9001:2015
ISO 14001 : 2015 ^Tr Certified
Auditors/Inspectors
Certified Accredited Laboratory TL-551 Succeed with Quality ISO 18001 : 2007
NRMCA
"This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system"
State of Qatar - Doha Industrial Area, Kassarat Road, R/A 41, P.0. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com
CTL)Grc>up .fO.fO.z) v-jQ-P jJjgjg>iLI ^nagJgjL^j' j-ux^ jjLuaJ^
QATAR
CONSTRUCTION TECHNOLOGY LABORATORIES GROUP W.L.L
Test Report
Determination Water Absorption of Precast Concrete Paving Block
CML 09-97

CTLG-Q Client: Qatar Clay Bricks

Contractor: N/A Report SN. # : 62599

Consultant: N/A Issue date: 18-Jul-2020

Project:** Evaluation of Materials Job order # : CTLGQ-JO-5-5JUL20-001

Location:** Industrial Area, Street # 52 Sampled by: Client

Sample type:** Insulation Block (400x250x200mm) - White Sampling method: N/A

Source/Supplier: N/A Tested by: Kashif

Client reference: N/A Testing Location: Main Lab

Production date: 14-Jun-2020 Test Environment: Lab Temperature (20±5°C)

Receiving date: 4-Jul-2020 Deviation: Specimen tested as saw cut

Testing date: 5-Jul-2020 to 9-Jul-2020 UoM: N/A

CTLGQ reference Receiving Weight (g) Dry Weight (g) SSD Weight (g) Water Absorption (%)

JUL04-102 21650 8044.5 8522.1 5.6

JUL04-103 21390 7999.6 8497.5 5.9

JUL04-104 20980 10680.4 11290.3 5.4

Average Water Absorption (%) 5.6

QCS 2014 Section : 13 Part: 04


Water Absorption (%)
Average of 3 Blocks Individual Block
Maximum 7% Maximum 7.5%

'Information provided by client


Note:- This document may not be reproduced except in its entirety. The result pertain only to the particular items tested.

Chandra Kanta Eng. MaMmoud/AI Shboul


Laboratory Supervisor Projects Manager

t C:.QU'

C.T.L. Grcjf. /.L.L.


cm Ho. f firms
P. O. Be*. '1-^12 - Doha - Qatar

RPT-0203 Rev.1 End of report Page 1 of 1

MOE/QGOSM J ISO 17025


3 Accredited Laboratory AS ACCREDITED’
Testing Laboratory
E qualityaustria ISO 9001 : 2015
ISO 14001 : 2015 r^Tr Certified
Auditors/Inspectors
Certified 71-651 Succeed with Quality ISO 18001 : 2007 NRMCA
"This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system"
State of Qatar - Doha Industrial Area, Kassarat Road, R/A 41, RO. Box 14212 | CR: 69008 | Tel: 40370130 | Capital: QAR 200,000 | Email: info@ctlgroupqatar.com | Web: ctlgroupqatar.com

You might also like