GENERAL
GENERAL
GENERAL
GENERAL- OPERATION
The starter generator drives the engine up to 45% NH. -On the ground, if there is no GPU, the second engine can
After 62.5% starter generator is a generator. First engine to be started with the battery and the power produced by the
be started (1 or 2) can be started using battery or a ground running engine starter/generator by using the cross-start.
power unit connected.
- In flight the cross-start cannot be used (to preserve the
NOTE: When connected GPU is prior to battery. integrity of the other engine starter/generator).
Second Engine to be started can be started using GPU or
Battery with support from engine running's starter generator.
FOR TRAINING PURPOSES ONLY!
ENG START selector switch has five positions : START 1 (2) Pushbutton Switch, initialization of the starting
sequence (Ref. 80-11) selected by means of ENG START
-START A, START B, START A+B positions enable : selector switch is controlled by START 1 (2) pushbutton
switch (ON legend).
-Arming of the start circuit
R01 Start pushbutton switch is a single-position switch:
-Arming of the ignition circuit with automatic cut off at the when released it R01 comes back to initial position. Once
end of the start sequence which is detected by the GCU of switch pushed, Start sequence R01 lauching request is
the related starter/generator (45% NH). memorized by BPCU till the end of the start.
-CRANK position enables : R01 NOTE : START 1 (2) pushbutton switch has no action
when either CONT RELIGHT R01 or OFF positions are
-Arming of the start circuit (Ref. 80-11) for motoring only. selected.
-OFF position :
- No circuit is supplied.
FOR TRAINING PURPOSES ONLY!
CRANKING
General Operation
Engine motoring is performed for particular configurations or Place ENG START selector switch in CRANK position and
maintenance press START 1 (2) pushbutton switch (ON legend comes
on); the engine is driven into rotation.
Operations :
For an engine wet motoring, place the condition lever in
-The dry motoring is used to evaporate the fuel remaining in FTR position as soon as NH sime 10%.
the combustion chamber (e.g. action on nozzles or aborted
start). NOTE : In any motoring configurations, the jet pump must
always be fuel supplied to avoid cavitation.
- The wet motoring is used to test HP fuel lines.
FOR TRAINING PURPOSES ONLY!
INDICATING
GENERAL
The power sources which can supply engine starting system Description/Operation
are :
Engine Starting by Main Battery. The engine starting, by
- Main battery ; main battery is required on ground when DC external power
is not connected and in flight.
- Main battery and running S/G ;
The starting sequence initiates when ENG START selector
- DC external power. switch 13KG is set to START (A or B or A + B or CRANK)
position; under this condition DC BPCU 9PG closes battery
DC external power has priority over the other sources. start contactor 3KG allowing main battery to supply the
Main battery can be used alone to start the first engine, starting line.
either left or right. If DC external power is not available, the
second engine is started by main the battery and the In this way pressing START 1 or 2 pushbutton switch 5KG
running S/G (this operation, in flight, is inhibited). (or 6KG), DC GCU 1 (5PU) or DC GCU 2 (6PU) closes
ENG 1 (or ENG 2) start contactor 1KG (or 2KG) connecting
the starting line to the S/G 1 (or 2).
FOR TRAINING PURPOSES ONLY!
INDICATING
When the engine reaches 45% of NH, starting sequence is Engine Starting by Cross-Start
finished the related contactor 1KG (or 2KG) opens first
followed by contactor 3KG. Once the first engine has been started using main battery,
the second engine is automatically started by using a cross-
NOTE: It is not necessary to maintain 5KG (or 6KG) start combination of main battery and the running S/G.
pushbutton pushed during all the starting duration. With the starting sequence already initiated (battery start
Once starting sequence launched is memorized by BPCU till contactor 3KG and ENG 1 or 2 start contactor 1KG or 2KG
starting stop. closed) when the start S/G reaches 10% NH associated
GCU transmits a signal to BPCU.
INDICATING
When the starting engine reaches 45% of NH, its starting Engine Starting by External Power
sequence is finished and both SC's open the followed by
BSC. When DC external power is available and delivering
acceptable quality it can connected to aircraft by closing DC
NOTE: Cross-start combination is inhibited in flight. external power contactor 11PG.
INDICATING
The following protective functions are provided for the Contactors position coherence protection
engines starting systems :
On ground with ENG START selector switch 13KG in
- Contactors position coherence protection START (A or B or A + B or CRANK) position, the contact
position of SC's is detected by means of the BPCU.
- Differential fault protection (DP). If the contact position of one of three (1KG, 2KG or 3KG) is
different from the commanded one the starting sequence is
inhibited.
INDICATING
Differential fault protection (DP) When the GCU detects a DP fault in any part of the
associated channel, the related starting operation is
The differential protection (DP) circuit controlled by the inhibited, causing FAULT legend of the START 1 or 2
GCU's allows to detect, even during starting operation, any pushbutton switch to come on and the crew alerting system
short circuit occurring in a zone extending from the neutral be activated.
side of the S/G winding to the S/G contactor.
This differential protection is operating only on ground while
in flight it is inhibited by related GCU (anyway DP
information is always transmitted to BPCU).
FOR TRAINING PURPOSES ONLY!
INDICATING
INDICATING
INDICATING
Alert
INDICATING
Preparation
Removal of DC starter/generator Note: installation position of clamp and position of both half-
rings with regard to clamp for re-installation.
-Unplug electrical connectors
Note: half-rings are differents. Remove lockwire, clamp and
-Mark and disconnect terminal lug of monitoring wire and half-rings securing starter/generator.
those of power supply wires
Note : starter/generator must be removed very carefully to
-Mark and disconnect terminal lugs of monitoring wires avoid damaging splined drive shaft. Remove
disconnect drain line starter/generator. Remove and discard o-ring
-Tighten nuts.
GLOSSARY
ABBREVIATION SIGNIFICATION
BAT Battery
BPCU Bus Power Control
Unit
CCAS Centralized Crew
Alerting System
DC Direct Current
DP Differential
Protection
ENG Engine
EPC External Power
Contactor
GCU Generator Control
Unit
NH High Pressure
Rotor Speed
P/BSW Pushbutton Switch
SC Start Contactor
FOR TRAINING PURPOSES ONLY!
S/G Starter/Generator
GPU Ground Power Unit