Every dwelling shall be

provided with at least one Habitable rooms – 14.00 cubic


At least two (2) exits
sanitary toilet and adequate meters of air space per person
shall be provided for
washing and drainage
every floor or section
facilities

The minimum width of any


corridor or passageway
serving as a required exit
or means of travel to or
from required exit shall be
one hundred twelve
centimeters (112 cm) in
the clear.

SECTION 1205. Floor


Construction (f) Regulation of
Equipment – All
shelves, fixtures, and
fixed equipment in a
projection room shall
be constructed of
incombustible
materials. All films not
in actual use shall be
stored in metal
cabinets having
individual
compartments for
reels or shall be in
Stairs shall be at least
generally accepted
750 millimeters in clear
shipping containers.
width, with a rise of
No solder shall be
200 millimeters and a
used in the
Door Leaf Width – minimum run of 200
The floor areas hereinabove provided may be construction of such
increased in certain specific instances and max of 1.20 millimeters. Minimum sizes of rooms and their cabinets
under appropriate conditions, based on the
least horizontal dimensions shall
existence of public space, streets or yards
There shall be at least follow the National Building Code of
extending along and adjoining two or more sides
of the building or structure subject to the one entrance and the Philippines.
approval of the Building Official. another one for exit.
Exterior balconies attached to or
supported by wall required to be of
masonry, shall have brackets or beams
constructed of incombustible materials.
Railings shall be provided for balconies,
landings, or porches which are more than
750 millimeters above grade.

The maximum height and


number of storeys of every
building shall be dependent
upon the character of
occupancy

Type III buildings shall be of


masonry and wood
construction.

Habitable rooms provided with Skylights shall have a glass area not less than that required for
artificial ventilation shall have a the windows that are replaced. They shall be equipped with
minimum ceiling heights based on a movable sashes or louvers with an aggregate net free area not
National Building Code of the less than that required for operable parts in the window that are
Philippines replaced or provided with approved artificial ventilation of
equivalent effectiveness.

Eaves over required


windows shall not be less
than 750 millimeters from
the side and rear property
lines.

Railings shall be provided


for balconies, landings, or
porches which are more
than 750 millimeters above
Exterior glass and glazing shall be capable of safely grade.
withstanding the load due to wind pressures for various height
zones above ground acting inward or outward.
No building
shall be
constructed
unless it
adjoins or
has direct
access to a
public space,
yard or street
on at least
one of its
sides.
SECTION 1215. Lathing, Plastering, and Installation of Wall Boards

The installation of lath, plaster and gypsum wall board shall conform to
the fire-resistive rating requirements and the type of construction of
building.