You are on page 1of 1

Technical & Physical Specifications of Rapicon Walls

Sr. No. Property units Standard Required Specifications

1 Length * mm 3000, 2700, 2400 3000, 2700, 2400


2 Width * mm 600 600
3 Thickness * mm 50 75
4 Edge Profile Square, Beveled Square, Beveled
5 Standard Weight ** kg/m2 43 58
6 Apparent Density kg/m3 IS2380P.3:77 700~800 700~800
7 Modulus of Rupture (MOR) MPa IS:2380P.5:77 4 ( - 0.2 / + Free) 3 (- 0.2 / + Free)
8 Uniform Distributed Load kg/m2 190 255
(UDL) @ 1.5 M span

9 Uniform Distributed Load kg/m2 70 95


(UDL) @ 2.9 M span

10 Axial Compressive Strength Kg/m2 IS2380 P.8.77 46 75


#
11 Typical Values
12 Thermal Conductivity K.cal/h.m°C ASTM C 177 0.12 0.12
13 Sound Transmission Class dB IS:9901 (Part3) - 1981 38 40
14 Fire Rating minutes Bs 476 part 20 & 22 108 134
15 Fire Resistance Properties
a Surface Spread of Flame BS 476 Part 7 - 1971 Class I Class I
b Fire Propagation Index ( I ) BS 476 Part 6 - 1981 <3 <3
c Ignitability BS 476 Part 5 – 1968 Class ‘P' (Not Class ‘P' (Not easily
easily ignitable) ignitable)
#
Values taken at actual from test certificates.
* Subject to tolerance, for detail refer to production test certificate.
** Depend upon Density