You are on page 1of 1

Done By:- NDR Job No:-DAR-J-109-PEB Shed-Estimate-R0 Date :- 24/03/2020

1. Building Parameters
S.NO DESCRIPTION DETAILS
1 LOCATION Rajkot, Gujrat
2 BUILDING TYPE Multi Span (Pitched Roof)
3 WIDTH 54.56 m O/O of Steel Line
4 LENGTH 60.96 m O/O of Steel Line
5 HEIGHT 7.985 m Clear Height
6 ROOF SLOPE 01:10
7 WIDTH MODULE 1 @ 19.965 m + 1 @ 19.965 m + 1 @ 14.63 m
8 BAY SPACING 3 @ 7.72 m + 5 @ 7.56 m
9 FUTURE EXPANSION Non Expandable
10 ENDWALL BAY SPACING 6 @ 6.655 m + 2 @ 7.315 m
11 BRACING Cross Rod Bracing & angle bracing for Wall & Cross Rod Bracing for Roof .
12 WALL CONDITION 2.44 mbrick wall and above sheeting.
13 STEEL GRADE FY-345 Mpa
14 DESIGN VERSION STAAD.Pro V8i (SELECT Series 5)

EOT CRANE NA
CANOPY 2 Nos. (2.0 m x Bay spacing)
FRAMED OPENINGS 2 No. (4.0 m x 4.0 m)
MEZZANINE 1 level Area =2435 m (39.93 m x 60.96 m) Height 4.27 m bottom of Mezz.
OTHER DETAILS
INSULATION ROOF NA
WALL NA
ACCESSORIES Skylights Wall Light Ridge Vent Turbo Vent
Poly Carbo.-16 Nos. NA NA 16 Nos.

2. Design Data
Dead Load Live Load Wind Load Collateral Load
DESIGN LOADS, KN/M2
0.1 0.57 39 m/sec 0.25
Frames Purlins Girts Crane Beam
SERVICEABILITY CRITERIA
H/100, L/180 L/180 L/120 -
DESIGN
Bridge Weight Trolley Wt. Wheel Load Wheel Base
CRITERIA CRANE DATA
- - - -
Dead Load Live Load Deflection
MEZZANINE LOAD kN/m2
3.75 3 L/240
CODES AISC/AISI/MBMA

3. Indicative Tonnage
Description Weight in Kg Remarks
Primary Steel 47445 All Built-up Members
Mezzanine Beam 94325 Including mezz. main beams, Joist & columns.
Crane Beam 0 Including crane beam,cap angle & connections
Staircase 1425 1 No.
Anchor Bolts & Templates 1450
Secondary Steel 20491 Including Coldformed members & Flange bracings
Hot Rolled Members 4409 Pipes & tubes
Roof Sheeting 17197 0.47MM thick Bare galvalume panel
Roof / Wall Accessories 1589 Including All trims,gutters & Downspouts
Wall Cladding 7981 0.50MM thick Color Coated panel
Rod bracing+Sag rod 2893
Other Wall Accessories 0
Decking Panels 19715 0.8mm thick deck sheet
Louver 1.5m x 1.22 m 0
Grand Total 218920.91 Kgs

4. Special Notes

1. Building is designed as an Enclosed building.


2 Purlin and Girts are considered of minimum thickness size (200Z1.5) mm Depth.
4. Main Frame column bases & wind column are Pinned base.
5. Building is designed as per AISC-2005
6.. Building class B considered for wind pressure calculations.
7.. Cross rod bracing and angle bracing considered along both sidewalls .
8. Gutter & Downspouts considered.
9. Framed opening is considered.
10. Rod bracing considered over roof and same is designed as tension member only.
11.Three Set of braced bay considered in the Shed.
12. Canopy soffit panel not considered.
13. Seismic zone III considered.
14. Wind Load is as per MBMA-2006. (Wind Pressure=0.555 Kn/m2)
15. Minimum Built up member thickness 5.0 mm considered.