PROJECT Building Use Domestic
OWNER: Design LL 1.5
SITE ADDRESS:

INSTALATION
DATE PREPARED
JOB NUMBER
SHEET NUMBER 1
DESIGN PARAMETERS
SOIL BEARING CAPACITY 100 Soil Description
SOIL CLASSIFIOCATION Sr Rock
WIND TERRAIN CATEGORY TC3 Region B
BUILDING LENGTH 20 Regional Velocity 60
BUILDING WIDTH 12
HEIGHT TO RIDGE 8000 Fill No
HEIGHT TO FLOOR 2500 Depth 0
STUMP SPACING 2100 (From Soil Report)
BEARER SPACING 3100
RISER HEIGHT mm 3500
NO. STORIES 2
UPPER FLOOR JOIST SPAN 0.00 0.00
ROOF SPAN 5000
ROOF TYPE SHEET
WALL HEIGHT 2700 0
Floor Loads Roof Walls Partitions
Upper Lower
LOADS DL 0.314268 0.31 0.25 0.3 0.25
LL 1.5 1.5 0.25 0 0
INSTALLATION SUMMARY
ANCHORS Minimum Depth as per AS 2870
LOCATION Min Pile Depth 0
UNDER INTERNAL WALLS 445
UNDER EXTERNAL WALLS 297 RISER STATUS
RISER SECTION 75 x 2.5 OK

FLOOR FRAME Select continuous


Select Type Trial Section Grade or single span STATUS
JOISTS Sawn Timbe 140 x 35 F17 single OK
BEARERS Sawn Timbe 120 x 70 F17 single OK

SUB FLOOR BRACING


Braces 32NB2.6
Fixings 2/12-24 Screw
NO. BRACES
PERPENDICULAR TO BUILDING LENGTH 26
PARRALEL TO BUILDING LENGTH 16
Note Brace capacity is calculated on compression
therefore each pair of braces represents 2 braces
R.E.Proud & Associates Pty. Ltd.
CIVIL AND STRUCTURAL ENGINEERS
Ballarat: Tasmania:
Unit 4, 903 Doveton Street, Ballarat, 3350 11 Kelcey Tier Road, Spreyton, Tasmania
Phone 03 5331 3477 Fax 03 5331 3577 Phone: 03 6427 2435 Fax: 03 6427 2148

COMPUTATION SHEET
Project: Job No.
Date Sheet No

ANCHOR LOADS FLOOR LOADS


Load Bearer DL LL Anchor Total Anchor
Width Span Load Installation
Int. Floor Loads only - Single Storey Conctruction Depth
Floor Loads 3.10 2.10 0.31 1.5 11.81088
Int. Partitions 3.10 2.10 0.25 0 1.6275
Roof 2.50 2.1 0.25 0.25 2.625 16.06 402
Int. Load Bearing Walls - 2 storey construction
L/B Walls 2.70 2.10 0.3 0 1.701
Upper Floor 0.00 2.10 0.314268 1.5 0
Lower Floor 3.10 2.10 0.314268 1.5 11.81088
Int. Partitions 3.10 2.10 0.25 0 1.6275
Roof 2.50 2.1 0.25 0.25 2.625 17.76 445
Ext.walls - Single Storey Conctruction
Floors 1.55 2.10 0.314268 1.5 5.905442
Walls 2.7 2.1 0.3 0 1.701
Int. Partitions 3.10 2.10 0.25 0 1.6275
Roof 2.50 2.1 0.25 0.25 2.625 11.86 297
Ext. walls- 2 storey construction
Ext Walls 2.70 2.10 0.3 0 1.701
Upper Floor 0.00 2.1 0.314268 1.5 0
Lower Floor 1.55 2.1 0.314268 1.5 5.905442
Int. Partitions 3.10 2.10 0.25 0 1.6275
Roof 2.50 2.1 0.25 0.25 2.625 11.86 297
Summary Internal Design Anchor Loads 444.5424
External Design Anchor Loads 296.7625
Maximum Axial Load on any anchor Internal Walls 17.76 444.54
External Walls 11.86 296.76 17.76
Anchor Capacity
Pile Capacity Soil Classification
Pile diam 42.4 Sr Rock
Circumfrence 133.20
Surface area/m long pile 0.13 Skin Friction 100
No. Piles in Group 3 Bearing Capacity of anchors /m of penitration
Total Surf Area 0.40 39.96
Riser Design
Axial Load 17.76 Effective Lgth "X" 2500
Eccentricity 30 Effective Lgth "Y" 2500
Bending Moment 0.53
Section Properties
Section 75 x 2.5 Material Properties
Ixx 614000 ryy 29.40 Fy 350
Iyy 614000 Iw 0.00 G 8.00E+04
Ze 18300 J 971000 E 2.00E+05
rxx 29.40 Area 709.00
R.E.Proud & Associates Pty. Ltd.
CIVIL AND STRUCTURAL ENGINEERS
Ballarat: Tasmania:
Unit 4, 903 Doveton Street, Ballarat, 3350 11 Kelcey Tier Road, Spreyton, Tasmania
Phone 03 5331 3477 Fax 03 5331 3577 Phone: 03 6427 2435 Fax: 03 6427 2148

COMPUTATION SHEET
Project Job.No.
Date Sheet No.
Column Section selected
Section Properties Material properties
Area 709 ryy 29.4 Fy 350 G 8.00E+04
rxx 29.4 Kf 1 E #######
Flexural Capacity Axial Capacity
Quater point BM's Eff. Lgths
Mm M2 M3 M4 lx ly L/rx L/ry L/Rmin
30 22.5 15 7.5 2500 2500 85.03401 85.03401 85.034014
critical flange eff length 3600 Alpha b (Kf=1.0) 0.5
Ms - (Knm) 6.405 Alpha b (Kf<1.0) 1
Mo - (Knm) 85.2317025 λ2 100.6136
Alpa(s) 0.9951193 α3 17.20365
Alpha(m) 1.81737645 λ4 109.2154
Alpha(m) design 1.81737645 η 0.312032
Mb - (Knm) 10.425135 ξ 0.945483
Mb design 5.7645 α3 0.481948
M' From analysis) 30 φ 0.9
Combined Actions Ns 248.15
Max M' reduced by axial force Nc 119.5954
Mrx 4.813118 Axial capacity 107.6359
N' (from analysis) 17.76
Sub Floor Bracing
No. Braces Based on end connections
Hor Length 2100
joint Type 2/12-24 Screw Vert Height 2500
Shear Capacity 17.2 Brace Angle 0.87
from Hor
Reg Vel 60 Side Wall End Walls
Height 8 Wall Surface Area 160 96
Mzcat 0.83 Total Force to be shared all Braces 285.70 171
Qz 1.49 Total Force at Brace Angle 444.19 266.52
Cpt 1.2 Min No. Braces Required 26 16
Design Press 1.79
Bracing Design
Parralell to Bearers Parallell to Joists Max Effective Length
Effective Lgth "X" an "Y 3265 3982 3982
Section 32NB2.6 Properties L/rx L/ry L/Rmin
Ixx 614000 Fy 350 135.46 135.46 135.46
Iyy 614000 G 8.00E+04 η 0.50
Ze 18300 E 2.00E+05 ξ 0.72
rxx 29.40 Alpha b (Kf=1.0) 0.5 α3 0.25
ryy 29.40 Alpha b (Kf<1.0) 1 φ 0.90
Iw 0.00 λ2 160.28 Ns 248.15
J 971000 α3 12.19 Nc 60.86
Area 709.00 λ4 166.37 Axial capacity 54.77
Kf 1 Side Wall End Walls
Min Number of Braces 8.11 4.87
R.E.Proud & Associates Pty. Ltd.
CIVIL AND STRUCTURAL ENGINEERS
Ballarat: Tasmania:
Unit 4, 903 Doveton Street, Ballarat, 3350 11 Kelcey Tier Road, Spreyton, Tasmania
Phone 03 5331 3477 Fax 03 5331 3577 Phone: 03 6427 2435 Fax: 03 6427 2148

COMPUTATION SHEET
Project Job.No.
Date Sheet No.
Joist Design
Span "L" Effective Spacing Section Dimensions
metres millimetres metres millimetres Depth Width
3.10 3100 0.45 450 140 35

Section Properties Restraint Conditions


Area Ixx Zxx Restraint Type Lay Lay/D S1 ρbS1
4900 8003333 114333.33 Type 1 1000 7.142857 13.36 14.30
Material Properties
grade F'b F't(HW) F't(SW) F's F'c E G ρb
F17 50 30 26 4.3 40 14000 930 1.07
Modification Factors
φ k1DL k1LL k1WL k4 k6 k9 k11 k12
0.8 1 1 0.57 1 1 1 1 0.79
Design Capacity Dead Load Only Dead Load + Live Load
φMb 2.05 3.59
Uniform Distributed Loading
DL LL WL Floor DL
Distributed Loads Kpa
0.31 1.50 0.00 Flooring 0.15
Self Wt
0.03 Joists 0.08
Serviceability Limit State KN/m
0.18 0.68 0.00 Bearers 0.04
Load factors 1.2 1.5 1.5 Coverings 0.05
Strenth Limit State Loads 0.21 1.01 0.00 0.31
M' 0.25 1.22 0.00
Concentrated Point Loads DL LL WL
Distributed Loads 0.00 0 0
Area 0 0 0
Serviceability Point Loads 0 0 0
Load Factors 1.2 1.5 1.5
Strenth Limit State Loads 0 0 0
M' 0 0 0
Total Limit State Bending Moments 0.252807 1.216266 0
Strength Summary DL Only Dead + Live Dead + Wind
M' 0.2528068 1.469072 0
Status OK OK OK
Serviceability Limits
Defl J2 Long Term Defl Defl Ratio Ratio Absolute Status
DL 1.88 2.00 3.76 824 360 12 OK
LL 7.24 1 7.24 428 360 12 OK
WL 0.00 1 0.00 0 240 12.92 OK

Restraint Definitions
Type 1 Discreet Restraint to compression edge
Type 2 Discreet Restraint to Tension edge
Type 3 Continuous Restraint to Compression edge
Type 4 Continuous Restraint to Tension Edge
R.E.Proud & Associates Pty. Ltd.
CIVIL AND STRUCTURAL ENGINEERS
Ballarat: Tasmania:
Unit 4, 903 Doveton Street, Ballarat, 3350 11 Kelcey Tier Road, Spreyton, Tasmania
Phone 03 5331 3477 Fax 03 5331 3577 Phone: 03 6427 2435 Fax: 03 6427 2148

Project Job.No.
Date Computation Sheet Sheet No.
Bearer Design
Span "L" Effective Spacing
metres millimetres metres millimetres Depth Width
2.10 2100 1.5 1500 120 70

Section Properties Restraint Conditions


Area Ixx Zxx Restraint Type Lay Lay/D S1 ρbS1
8400 10080000 168000 Type 1 1000 8.333333 13.36 14.30
Material Properties
grade F'b F't(HW) F't(SW) F's F'c E G ρb
F17 50 30 26 4.3 40 14000 930 1.07
Modification Factors
φ k1DL k1LL k1WL k4 k6 k9 k11 k12
0.8 1 1 0.57 1 1 1 1 0.79
Design Capacity Dead Load Only Dead Load + Live Load
φMb 3.01 5.28
Uniform Distributed Loading
DL LL WL
Distributed Loads Kpa 0.31 1.50 0.00
Self Wt 0.06
Serviceability Limit State KN/m 0.53 2.25 0.00
Load factors 1.2 1.5 1.5
Strenth Limit State Loads 0.64 3.38 0.00
M' 0.35 1.86 0.00
Concentrated Point Loads DL LL WL
Distributed Loads 0.00 0 0
Area 0 0 0
Serviceability Point Loads 0 0 0
Load Factors 1.2 1.5 1.5
Strenth Limit State Loads 0 0 0
M' 0 0 0
Total Limit State Bending Moments 0.35034 1.860469 0
Strength Summary DL Only Dead + Live Dead + Wind
M' 0.35034 2.210808 0
Status OK OK OK
Serviceability Limits
Defl J2 Long Term Defl Defl Ratio Ratio Absolute Status
DL 0.95 2.00 1.90 1105 240 12 OK
LL 4.04 1 4.04 520 240 12 OK
WL 0.00 1 0.00 0 240 8.75 OK
R.E.Proud & Associates Pty. Ltd.
CIVIL AND STRUCTURAL ENGINEERS
Ballarat: Tasmania:
Unit 4, 903 Doveton Street, Ballarat, 3350 11 Kelcey Tier Road, Spreyton, Tasmania
Phone 03 5331 3477 Fax 03 5331 3577 Phone: 03 6427 2435 Fax: 03 6427 2148

Building Act 1993 Form 13


Building Regulations 1994
Regulation No. 15.7(2)
CERTIFICATE OF COMPLIANCE - DESIGN
To:
Relevant Building Surveyor
Postal Address

From: Ross Eric Proud


Building Practitioner Category/Class Engineer (Civil)
of: Unit 4, 903 Doveton Street, Ballarat, 3350

Property Details:

Municipal District:

Compliance
I did Prepare the design and certify that part of the design/building work described as:
MEGA ANCHOR STUMPS AND FLOOR FRAMING
Complies with the following provisions of the Regulations
Building Code of Australia
Building code of Australia Part 2.1
Building code of Australia Part 3.11
AS 1170.1 & 2 Loading Code
AS 2870 Residential Slabs
Design Documents
Job No. No. Sheets Prepared by Date
Computations 5 Ross Proud
Project Drawings 2 Ross Proud

Signed
Ross Proud
Building Practitioner
Registration No. EC1039
Date: