INSTALATION
DATE PREPARED
JOB NUMBER
SHEET NUMBER 1
DESIGN PARAMETERS
SOIL BEARING CAPACITY 100 Soil Description
SOIL CLASSIFIOCATION Sr Rock
WIND TERRAIN CATEGORY TC3 Region B
BUILDING LENGTH 20 Regional Velocity 60
BUILDING WIDTH 12
HEIGHT TO RIDGE 8000 Fill No
HEIGHT TO FLOOR 2500 Depth 0
STUMP SPACING 2100 (From Soil Report)
BEARER SPACING 3100
RISER HEIGHT mm 3500
NO. STORIES 2
UPPER FLOOR JOIST SPAN 0.00 0.00
ROOF SPAN 5000
ROOF TYPE SHEET
WALL HEIGHT 2700 0
Floor Loads Roof Walls Partitions
Upper Lower
LOADS DL 0.314268 0.31 0.25 0.3 0.25
LL 1.5 1.5 0.25 0 0
INSTALLATION SUMMARY
ANCHORS Minimum Depth as per AS 2870
LOCATION Min Pile Depth 0
UNDER INTERNAL WALLS 445
UNDER EXTERNAL WALLS 297 RISER STATUS
RISER SECTION 75 x 2.5 OK
COMPUTATION SHEET
Project: Job No.
Date Sheet No
COMPUTATION SHEET
Project Job.No.
Date Sheet No.
Column Section selected
Section Properties Material properties
Area 709 ryy 29.4 Fy 350 G 8.00E+04
rxx 29.4 Kf 1 E #######
Flexural Capacity Axial Capacity
Quater point BM's Eff. Lgths
Mm M2 M3 M4 lx ly L/rx L/ry L/Rmin
30 22.5 15 7.5 2500 2500 85.03401 85.03401 85.034014
critical flange eff length 3600 Alpha b (Kf=1.0) 0.5
Ms - (Knm) 6.405 Alpha b (Kf<1.0) 1
Mo - (Knm) 85.2317025 λ2 100.6136
Alpa(s) 0.9951193 α3 17.20365
Alpha(m) 1.81737645 λ4 109.2154
Alpha(m) design 1.81737645 η 0.312032
Mb - (Knm) 10.425135 ξ 0.945483
Mb design 5.7645 α3 0.481948
M' From analysis) 30 φ 0.9
Combined Actions Ns 248.15
Max M' reduced by axial force Nc 119.5954
Mrx 4.813118 Axial capacity 107.6359
N' (from analysis) 17.76
Sub Floor Bracing
No. Braces Based on end connections
Hor Length 2100
joint Type 2/12-24 Screw Vert Height 2500
Shear Capacity 17.2 Brace Angle 0.87
from Hor
Reg Vel 60 Side Wall End Walls
Height 8 Wall Surface Area 160 96
Mzcat 0.83 Total Force to be shared all Braces 285.70 171
Qz 1.49 Total Force at Brace Angle 444.19 266.52
Cpt 1.2 Min No. Braces Required 26 16
Design Press 1.79
Bracing Design
Parralell to Bearers Parallell to Joists Max Effective Length
Effective Lgth "X" an "Y 3265 3982 3982
Section 32NB2.6 Properties L/rx L/ry L/Rmin
Ixx 614000 Fy 350 135.46 135.46 135.46
Iyy 614000 G 8.00E+04 η 0.50
Ze 18300 E 2.00E+05 ξ 0.72
rxx 29.40 Alpha b (Kf=1.0) 0.5 α3 0.25
ryy 29.40 Alpha b (Kf<1.0) 1 φ 0.90
Iw 0.00 λ2 160.28 Ns 248.15
J 971000 α3 12.19 Nc 60.86
Area 709.00 λ4 166.37 Axial capacity 54.77
Kf 1 Side Wall End Walls
Min Number of Braces 8.11 4.87
R.E.Proud & Associates Pty. Ltd.
CIVIL AND STRUCTURAL ENGINEERS
Ballarat: Tasmania:
Unit 4, 903 Doveton Street, Ballarat, 3350 11 Kelcey Tier Road, Spreyton, Tasmania
Phone 03 5331 3477 Fax 03 5331 3577 Phone: 03 6427 2435 Fax: 03 6427 2148
COMPUTATION SHEET
Project Job.No.
Date Sheet No.
Joist Design
Span "L" Effective Spacing Section Dimensions
metres millimetres metres millimetres Depth Width
3.10 3100 0.45 450 140 35
Restraint Definitions
Type 1 Discreet Restraint to compression edge
Type 2 Discreet Restraint to Tension edge
Type 3 Continuous Restraint to Compression edge
Type 4 Continuous Restraint to Tension Edge
R.E.Proud & Associates Pty. Ltd.
CIVIL AND STRUCTURAL ENGINEERS
Ballarat: Tasmania:
Unit 4, 903 Doveton Street, Ballarat, 3350 11 Kelcey Tier Road, Spreyton, Tasmania
Phone 03 5331 3477 Fax 03 5331 3577 Phone: 03 6427 2435 Fax: 03 6427 2148
Project Job.No.
Date Computation Sheet Sheet No.
Bearer Design
Span "L" Effective Spacing
metres millimetres metres millimetres Depth Width
2.10 2100 1.5 1500 120 70
Property Details:
Municipal District:
Compliance
I did Prepare the design and certify that part of the design/building work described as:
MEGA ANCHOR STUMPS AND FLOOR FRAMING
Complies with the following provisions of the Regulations
Building Code of Australia
Building code of Australia Part 2.1
Building code of Australia Part 3.11
AS 1170.1 & 2 Loading Code
AS 2870 Residential Slabs
Design Documents
Job No. No. Sheets Prepared by Date
Computations 5 Ross Proud
Project Drawings 2 Ross Proud
Signed
Ross Proud
Building Practitioner
Registration No. EC1039
Date: