Job No: Shed-Estimate-R0 Date :- 28/01/2022

1. Building Parameters
S.NO DESCRIPTION DETAILS
1 LOCATION Nagpur, MH
2 BUILDING TYPE Clear Span (Pitched Roof) + Lean to
3 WIDTH 12.5 m O/O of Steel Line
4 LENGTH 25 m O/O of Steel Line
5 HEIGHT 6m Clear Height
6 ROOF SLOPE 1:10
7 WIDTH MODULE 1 @ 12.5 m
8 BAY SPACING 4 @ 6.25m
9 FUTURE EXPANSION Non Expandable
10 ENDWALL BAY SPACING 2 @ 6.25 m
11 BRACING Cross Rod Bracing and angle bracing for Wall & Cross Rod Bracing for Roof .
12 WALL CONDITION 3.0 m brick wall and above sheeting.
13 STEEL GRADE FY-345 Mpa
14 DESIGN VERSION STAAD.Pro V8i (SELECT Series 6)

EOT CRANE NA
CANOPY 1 Nos (1.8m X Bay Spacing)
FRAMED OPENINGS NA
MEZZANINE 312.5 m2; (12.5m X 25m ) Bottom of Mezzanine beam = 3m
OTHER DETAILS
INSULATION ROOF NA
WALL NA
ACCESSORIES Skylights Wall Light Ridge Vent Turbo Vent
Poly Carbo.-5 Nos. NA NA 5 Nos

2. Design Data
2 Dead Load Live Load Wind Load Collateral Load
DESIGN LOADS, KN/M
0.1 0.57 44 m/sec 0.001
Frames Purlins Girts Crane Beam
SERVICEABILITY CRITERIA
H/100, L/180 L/150 L/120 -
DESIGN
Bridge Weight Trolley Wt. Wheel Load Wheel Base
CRITERIA CRANE DATA
- - - -
Dead Load Live Load Deflection
MEZZANINE LOAD kN/m2
3.75 3.5 L/240
CODES AISC/AISI/IS-875/IS-1893-2002

3. Indicative Tonnage
Description Weight in Kg Remarks
Primary Steel 5757 All Built-up Members with mezz.
Mezzanine 11953 Including crane beam & connections
Staircase 1350
Anchor Bolts & Connection Bolts 400
Secondary Steel 2464 Including Coldformed members & Flange bracings
Hot Rolled Members 910 Pipes & tubes
Roof Sheeting 1612 0.47MM thick Bare galvalume panel
Roof / Wall Accessories 531 Including All trims,gutters & Downspouts
Wall Cladding 1155 0.47MM thick Color Coated panel
Rod bracing+Sag rod 622
Other Wall Accessories 0
Decking Panels 2550 0.8mm thick deck sheet
Walkway 0 Including walkway beam & checqured plate
Roof Monitor 0 including frame,purlin and sheeting
Grand Total 29302.67 Kgs

4. Special Notes

1. Building is designed as an Enclosed building.(Cpi=+/-0.2)


2 Purlin and Girts are considered of minimum thickness size (200Z1.5) mm Depth.
4. Main Frame column bases & wind column are Pinned base.
5. Building is designed as per AISC-2005
6.. Building class B considered for wind pressure calculations.
7.Cross rod bracing & angle bracing considered along both sidewalls.
8. Gutter & Downspouts considered.
9. Framed openings are not considered.
10. Rod bracing considered over roof and same is designed as tension member only.
11.Two Set of braced bay considered in the Shed.
12. Canopy soffit panel not considered.
13. Seismic zone II considered.
14. Wind Load is as per IS-875-PART-3-2015. (Wind Pressure=0.659 Kn/m2)
15. Minimum Built up member thickness 5.0 mm considered.
16. This estimated tonnage may vary by +/-3% for miscallenious items.