You are on page 1of 1

DESIGN DATA

LENGTH 40m C/C of steel columns


WIDTH 30m C/C of steel columns

FRAME TYPE Multi span 2@15m c/c of columns


FEAME spacing 5 @ 8m c/c of columns
Eave height/ Clear 12m clear ht
Roof slope 1 in 20

MEZZANINE Yes Crane Yes


FFL 4.25m No of cranes 2 1 per bay
Deck matl TS45 or eq -S345 Crane SWL 10T EACH
Deck type Non composite Hook ht 8m
SLAB 125mm + A242 Mesh Crane Supplier Unknown
Finishes 50mm screed + tiles Ladder Nil
STAIR + HR 1 No.
SIDE WALLS END WALLS
Block wall ht Gird 1 to 4 1m Factory Block wall ht Grid 1 1m
Block wall ht Grid 4 to 5 5.25m & 7.25m As shown in dwg Block wall ht Grid 5 5.25m & 7.25m
Sheeting above block wall Single skin Sheeting above block wall Single skin
Windows 2m W x 1.5m H - 2 per bay Windows Grid 5 1.5m W x 1.5m H - 8x2 Nos
Ventilators 2m W x 1.5m H - 2 per bay Windows Grid 1 1.5m W x 1.5m H - 8x1 Nos
RS NIL RS Grid 1&5 3m Wx 3m H 2 X2
Doors As shown Doors As shown

ROOF FASCIA
SHEETING Single skin SHEETING Single skin both sides
Roof monitor Nil Height 1m above Eave
Ridge vent Nil
Skylight Nil
Duct Nil
Gutter Valley Both sides
DS 1 @ each grid

LOADS CODES
2
DEAD 0.15 kN/m IS875
2
LIVE 0.57 kN/m IS875
WIND Openings 5-20 % IS 875
SEISMIC Zone IV IS 1893
CRANE 10T Supplier data
DESIGN IS 800
Horizontal deflection for frame : H/150
Vertical deflection for frame : L/180
Mezzanine beams L/250
Min.Thickness of Secondaries : Not Apllicable
Min. Thickness of Primaries : Not Applicable
Side Wall Columns Sections / Base : Straight / Fix Bases
Intererior Columns Sections / Base : Not Applicable
End Wall Columns Sections / Base : Not Applicable
CROSS BRACING ALLOWED GRID 1 -2 & 3-4 Side walls