Operating Instructions
• This manual is an essential part of the unit and contains important hints about function,
correct handling and commissioning. Non-observance can result in damage to the unit
or the machine or even in injury to persons using the
equipment!
• The unit must only be installed, connected and activated by a qualified electrician
• It is a must to observe all general and also all country-specific and application-specific
safety standards
• When this unit is used with applications where failure or maloperation could cause
damage to a machine or hazard to the operating staff, it is indispensable to meet
effective precautions in order to avoid such consequences
• Regarding installation, wiring, environmental conditions, screening of cables and
earthing, you must follow the general standards of industrial automation industry
• - Errors and omissions excepted –
Version: Description:
BY34002a/April 07/mb/hk First edition
BY34002b/Juli 07/mb/hk Small corrections and supplements
BY340:
Front size 96 x 48 mm (3.780’’ x 1.890’’)
Speed ratio setting by keypad
Analogue output 14 bits
4 power transistor outputs (alert)
BY641:
Front size 96 x 96 mm (3.780’’ x 3.780’’)
Speed ratio setting by keypad
or by front thumbwheel switches
Analogue output 14 bits
4 power transistor outputs (alert)
and 4 relay outputs (alert)
Both models are suitable for front panel or operator desk mounting, by means of the included
mounting clamps.
Where you desire to mount the units on DIN rails inside a cabinet, please refer to the mounting
brackets type SM 300 and SM 600 available as accessories.
Figure: SM300 mounting bracket for DIN rail mounting of BY340 units
Speed
Index variable Index
Master drive Slave
Master (optional) (optional)
Encoder
0-10V Slave
Encoder
BY Controller
• This manual first provides all basic instructions for operation of model BY340
• For operation of relays and thumbwheels with model BY 641 see appendix
• For PC setup our “OS32” software is available on the CD included to delivery,
or on our homepage www.motrona.com
• For communication by PLC or IPC or by a remote operator terminal, please
observe the serial protocol details described in our separate manual “Serpro”.
• PROFIBUS communication is possible with use of our gateway PB251.
Ana.out 20 mA
Ana.out +/-10V
+5,2V aux. out
+24V aux. out
RxD (RS232)
Master, /A
Master, /B
Slave, /A
Slave, /B
Cont. 3
Cont. 4
K4 out
K3 out
PROG
GND
GND
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
X1
17 18 19 20 21 23 24 25 26 27 28 29 30 31 32
X2
Cont. 1
+Vin
+5,2V aux.out
Slave, B
GND
GND
+24V aux.out
Master, B
Master, A
GND
Cont. 2
Com+ (K1-K4)
TxD (RS232)
K2 out
K1 out
Slave, A
+24
19
+5 18 29 Com+ (K1 - K4)
Example shows wiring A 24
for encoders with 5 volts 26 K1 out Alert 1
Master /A 8
power supply and B 23 25 K2 out Alert 2 / Index ok
RS422 line driver output /B 7
- 20 10 K3 out Max. Correction
+24
3
+5 9 K4 out
2 Max. Frequency
A 22
Slave /A
6
B 21 16 +/-10V
/B 5
- 4
15 20 mA
Slave motor
Cont1 32 0V, GND Analogue
28
Reset, Trim, Cont2 27 output
Index etc. Cont3 12
Cont4 11
RxD
RS232 14
TxD 30
GND 31
17 1 13
Drive
+ - 24 V DC
Power supply ∼
Slave speed signal ∼ 24 V AC PROG Slave speed signal
BY 340 30
TxD TxD 3 PC
31 GND 5 (Sub-D-9)
For details of the serial communication protocol, please refer to the special “Serpro” manual.
With most of the applications it is desirable to have proportional characteristics of Factor1, i.e.
we like to increase the Slave speed when we increase Factor1.
Some application however may require reciprocal characteristics (e.g. when we use the unit for
a rotary cutter application where Factor1 is used to set the cutting length. In this case, higher
setting requires lower Slave speed, i.e. Factor1 has to operate reciprocally.
Both, proportional and reciprocal characteristics can be selected by parameter. Depending on
these settings, the distances (and also the speeds) follow to one of the formulae below:
Proportional Operation :
Reciprocal Operation :
5. Operating Modes
The operating mode (parameter F02.004) sets the functions of Trim and Index inputs, provided
that these functions have been assigned to some Control Inputs or front keys.
Mode Impulse scaling
Trim Input Function Index Input Function
F02.004 (Slave : Master)
1 +/- Phase trim by internal No Function Fact 1 : Fact 2
timer. Temporary change of
Slave speed while one of
the Trim commands is on.
2 Similar to Mode 1 Index control with adjustable phase Fact 1 : 1.00000
Index Master
Adjustable Phase Offset
Index Slave
Jump (Offset)
Slave position after index signal
P «
PROG UP DOWN ENTER
Key functions depend on the actual operating state of the unit. Essentially we have to describe
three basic states:
• Normal operation
• General setup procedure
• Direct fast access to scaling factors
During the general setup procedure all control activities remain disabled. New
parameter settings become active after return to normal operation only.
This will access the parameter group F01 right away. To change the settings follow the same
procedure as already described above. Besides the advantage of direct access, the fundamental
difference to general setup is the following:
During the fast access procedure all control functions remain fully active.
Access is limited to Factor settings; no other parameters can be changed.
P «
PROG UP DOWN ENTER
Saves the actual value Increments the Decrements the Shifts the cursor (blinking
shown in the display and highlighted highlighted digit) one position to the
returns to the parameter (blinking) digit (blinking) digit left, or from utmost left
selection level to right
With signed parameters the left digit scrolls from 0 to 9 and then shows “–„ (negative) and
“-1“ (minus one). The example below shows how to change a parameter from the actual setting
of 1024 to the new setting of 250 000.
This example assumes that you have already selected the parameter group and the parameter
number, and that you actually read the parameter value in the display.
Highlighted digits appear on colored background.
Step Display Key action Comment
Display of actual parameter setting, last
00 001024 digit is highlighted
01 4x Scroll last digit down to 0
Where you decide to take this action, please note that all parameters and
settings will be lost, and that you will need to run a new setup procedure again.
-4 ... 0 ... +4
+5 ... +8
+9 ... +16
+17 ... +32
+33 ... +64
> +64
Bar graph display with reference to the actual synchronization error
The diagram shows positive errors only (Slave lags Master). Negative errors are mirror-inverted.
Where instead you find the mask blank with the indication „OFFLINE“ in the top bar, please
click to the „Comms“ menu and check the serial settings of your PC.
Set all parameters in the Edit filed according to your needs, following the hints given in this
manual. The following parameters should initially be set to the values as shown:
Number Register Initial Setting
F02.004 Operation mode 1
F02.006 Integration Time 0000
F02.007 Correction Divider 0
F05.040 Correction Gain 1.000
F05.041 Max. Correction 10.000
After entry of all parameters click to “Transmit All” followed by “Store EEProm” to store all
parameters to the BY340 or BY641 controller.
You can reset the differential counter to zero at any time between, by cycling
the “Reset” command.
Once you have successfully concluded these steps, you can exit the Adjust menu.
Your synchronous application is ready to work now.
Too high settings of Gain-Correction and too low settings of the Integration Time
will cause stability problems like oscillation or hunting of the Slave
K3-NO
K2-NO
K1-NO
K4 - C
K4-NC
K3 - C
K3-NC
K2 - C
K2-NC
K1 - C
K1-NC
X6 X5 X4 X3
44,0 (1.732)
(.315)
8,0
(.394)
10,0
48,0 (1.890)
90,5 (3.563)
8,0 (.315)
(.394)
10,0