Professional Documents
Culture Documents
ECR WH
DIN34
A A
REMOTE CONTROL PANEL REMOTE CONTROL PANEL
( R C S - E C R) (RCS-W H)
RESERVED
PORT REMOTE CONTROL PANEL (RCS-ECR) STBD PORT REMOTE CONTROL PANEL (RCS-WH) STBD
H3 H6 H3 H6
A1 S1
H1 H2 PB1 PB2 H1 H2 PB1 PB2
M / E A L A R M P AN EL M / E A L A R M P AN EL
COPYRIGHT
(ECP) (ECS)
B B
REFER TO DRAWING
P2199A2016
FOR DETAIL
C ER C
N1
H1 H2 H3 H4
PB1 S1
Schutzvermerk nach DIN34 beachten
H5 H8
H6 H9
H7 H10
D REMOTE D
CONTROL PANEL
(MPC)
PORT STBD
M/E AIR SOURCE PANEL M/E AIR SOURCE PANEL
(ASPP) (ASPS)
PORT PORT
GEARBOX MAIN ENGINE
E REFER TO DRAWING E
P2199A2016
FOR DETAIL
STBD STBD
GEARBOX MAIN ENGINE
NOTE:
ALL CABLES ARE SUPPLIED BY YARD
F 1 As Built 2 4 . 1 0 . 2016 LingJing Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +
0 AFC 07.09.2016 LingJing Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat System
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 1
Hull KN6000-01 Block Diagram
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2199B16.O of 1 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
ITEM TEXT DESCRIPTION
RESERVED
860 mm 250 mm
835 mm
C 800 mm C
4XØ11 mm
TRUNKING
N1
Schutzvermerk nach DIN34 beachten
FUSE
FUSE
H1 H2 H3 H4
PB1 S1
TRUNKING
D D
TRUNKING
560 mm
H5 H8 600 mm
H6 H9
H7 H10 TRUNKING
TRUNKING
E E
TRUNKING
SPECIFICATIONS
1. COLOR : RAL 7032 FRONT VIEW SIDE VIEW BASEPLATE
2. WEIGHT : APPROX. 40KG
3. PROTECTION CLASS : IP54
F 1 As Built 2 4 . 1 0 . 2016 LingJing Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +10
0 AFC 07.09.2016 LingJing Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat Panel
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 1
Hull KN6000-01 (MPC)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2199B16.P of 3 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
240 mm 154 mm 130 mm
220 mm
4XØ5 mm AS BUILT
24 OCT 2016
DIN34
A A
D D
H4 A A
H4
S
T
S
T RECOMMENDED INSTALLATION SPACE
200 mm
220 mm
H5
E
R
N
E
R
N H5 FOR CONNECTORS
Z2 Z4
COPYRIGHT
B B
Z1 Z3 A1
H1 H2 PB1 PB2
YANMAR AUTOMATION
200 mm
4XØ10 mm
ITEM TEXT DESCRIPTION
TRUNKING
Schutzvermerk nach DIN34 beachten
SPECIFICATIONS
1. COLOR : BLACK
2. PROTECTION CLASS : IP22
3. CUT-OUT DIMENSION : 204(W) x 184(H) MM BASEPLATE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +20
0 AFC 07.09.2016 LingJing Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat Panel
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 2
Hull KN6000-01 (RCS-ECR)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2199B16.P of 3 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
AS BUILT
24 OCT 2016
DIN34
A A
240 mm 154 mm 130 mm
220 mm
RESERVED
4XØ5 mm
PORT REMOTE CONTROL PANEL (RCS-WH) STBD
A A
H3 H
E
H
E
H3
COPYRIGHT
A A
D D
H4 H4
B A A B
S
T
S
T RECOMMENDED INSTALLATION SPACE
200 mm
220 mm
FOR CONNECTORS
E E
H5 R
N
R
N H5
Z2 Z4
Z1 Z3
S1
H1 H2 PB1 PB2
C YANMAR AUTOMATION
C
85 mm
PB1. CONTROL POSITION CONFIRM - BLUE
PB2. LA M P /BUZZER TEST - WHITE
S1. DIMMER -
TERMINAL STRIP
Z1. COMMAND KEY WITH COMMAND LED
E E
Z2. DEVICE STATUS LED
Z3. A L A R M K E Y W I T H A L A R M L E D
Z4. BRIGHTNESS SENSOR
SPECIFICATIONS
1. COLOR : BLACK
2. PROTECTION CLASS : IP22
3. CUT-OUT DIMENSION : 204(W) x 184(H) MM
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Revision History:A
DIN34
A A
Date Revision Page
1 05.08.2016 LingJing For Approval P2199B16_O.0001
RESERVED
COPYRIGHT
B B
C C
Schutzvermerk nach DIN34 beachten
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Revision History:B
DIN34
A A
Date Revision Page
1 19.08.2016 LingJing Revised P2199B16_O.0001
RESERVED
C C
Schutzvermerk nach DIN34 beachten
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Revision History:0
DIN34
A A
Date Revision Page
1 07.09.2016 LingJing AFC P2199B16_M.0001
RESERVED
C C
Schutzvermerk nach DIN34 beachten
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Revision History:1
DIN34
A A
Date Revision Page
1 24.10.2016 LingJing As Built P2199B16_M.0001
RESERVED
B B
C C
Schutzvermerk nach DIN34 beachten
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
SYMBOL LEGEND
RESERVED
4-20mA
C STOP C
PRESSURE TRANSMITTER
FUSE
NORMALLY OPEN PUSH BUTTON
FLASHER
D LAMP D
NORMALLY CLOSE PUSH BUTTON
RESISTOR
D1 DIODE
P NORMALLY OPEN PRESSURE SWITCH
13 VARISTOR
RELAY NORMALLY CLOSE PRESSURE SWITCH
P
14
E 7 E
TIME RELAY NORMALLY OPEN TEMPERATURE
SWITCH POTENTIOMETER
2
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
D D
.
.
Panel(s) \ Equipment(s)
Externally Connected
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
ECR WH
DIN34
A A
REMOTE CONTROL PANEL REMOTE CONTROL PANEL
( R C S - E C R) ( R C S - W H)
RESERVED
PORT R E M O T E CONTROL PANEL (RCS-ECR) STBD PORT REMOTE CONTROL PANEL (RCS-WH) STBD
H3 H6 H3 H6
H5 H8 H5 H8
A1 S1
H1 H2 PB1 PB2 H1 H2 PB1 PB2
COPYRIGHT
YANMAR YANMAR
X2 X3 X2
C C
ENGINE ROOM
X5
Schutzvermerk nach DIN34 beachten
STATION
N1
D D
H1 H2 H3 H4
PB1 S1
H5 H8
H6 H9
H7 H10
E E
REMOTE CONTROL PANEL
(MPC)
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
101 24VDC+
5.1
102 24VDC- 5.1
DIN34
A 201 24VDC+ A
8.1
202 24VDC- 8.1
RESERVED
1F-301 24VDC+
-F1 -F2 -F3 -F4 10.1
4A 4A 10A 10A 1F-302 24VDC-
10.1
1F-401 24VDC+ 5.1
010
020
1F-402 24VDC-
5.1
=1F =1F =1F =1F
COPYRIGHT
2F-301 24VDC+
-N1 [20A] -F5 -F6 -F7 -F8 10.1
B Vout + - B
4A 4A 0.5A 0.5A 2F-302 24VDC-
ALARM A 10.1
2F-401 24VDC+
ALARM B
5.1
Vin
A+ - B+ - 2F-402 24VDC- 5.1
=2F =2F =2F =2F
-F5 -F6 -F7 -F8
4A 4A 0.5A 0.5A
C C
-H1 -H2
Schutzvermerk nach DIN34 beachten
PORT STBD
SYSTEM SYSTEM
POWER POWER
ON ON
1F-901
2F-901
PORT PORT STBD STBD
D CLUTCH EP CLUTCH EP D
CIRCUIT CONVERTER CIRCUIT CONVERTER
1 5 1 5
=1F =2F
13 13 13 13
1F-X1/+
1F-X1/-
2F-X1/+
2F-X1/-
-K1 -K1
9 9 =1F =1F =2F =2F
4.5 4.7
-K1 -K2 -K1 -K2
1F-902
2F-902
14 14 14 14
=1F =2F
-X1. . -X1. .
+ - + - 1 5 1 5
=1F =2F
E -K2 -K2 E
9 9
4.6 4.8
5 5 5 5
-X5 -X5 1 9 4.3 1 9 4.3 1 9 4.4 1 9 4.4
+ - + - 6 6 6 6
24VDC 24VDC 2 10 2 10 2 10 2 10
11.1 11.1 11.4 11.4
7 7 7 7
3 11 3 11 3 11 3 11
REFER TO DWG REFER TO DWG
P2199A2016 P2199A2016 8 8 8 8
4 12 4 12 4 12 4 12
ECP ECS
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +10
Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat Panel
1 As Built 2 4 . 1 0 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 4
Hull KN6000-01 (MPC)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 wir.dwg P2199B16.W of 19 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A 1F-401 24VDC+ A
4.8
4.8 2F-401 24VDC+
RESERVED
REMOTE
LOCAL
-S1
COPYRIGHT
LOCAL/
REMOTE
B CONTROL B
SELECTOR
LOCAL=OPEN
REMOTE=CLOSE
-K4
1 5
C 5.2 C
903
Schutzvermerk nach DIN34 beachten
REMOTE
X402
X401
D CONTROL D
CONFIRM
=1F =2F
13 13 -X4. . -X4. . -X2. . -X2. .
7
-K3 -K4 -K4A 2 1 + - + - + -
2 (0.8S) 14 14
MODE D
2F-402 24VDC-
4.8
1F-402 24VDC-
4.8
E 102 24VDC- E
4.8 6.1
3 5 5
4 1 7.3 1 9 5.2 1 9 8.1 EC+ -X2 -X2
6 6 8 12.1
EC- + - + -
5 8 2 10 4 12 12.1
7.7 7.2 8.1 EC01
7 12.6
3 11 11.3 EC02 12.6 REFER TO DWG REFER TO DWG
8 RCS-ECR P2199A2016 P2199A2016
4 12 11.5
ASPP ASPS
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +10
Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat Panel
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 5
Hull KN6000-01 (MPC)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 wir.dwg P2199B16.W of 19 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
RESERVED
COPYRIGHT
B B
C C
Schutzvermerk nach DIN34 beachten
D D
1F-X308
1F-X310
2F-X308
2F-X310
13 13 13 13
=1F =1F =2F =2F
=1F =1F -K5 -K6 =2F =2F -K5 -K6
-X3. . -X3. . 14 14 -X3. . -X3. . 14 14
7 8 9 10 7 8 9 10
E 102 24VDC- E
5.8 7.1
5 5 5 5
1 9 7.4 1 9 7.4 1 9 7.5 1 9 7.6
A1 A2 B1 B2 6 6 A1 A2 B1 B2 6 6
AHEAD ASTERN 2 10 2 10 AHEAD ASTERN 2 10 2 10
7.4 7.5 7.6 7.6
FEEDBACK FEEDBACK 7 7 FEEDBACK FEEDBACK 7 7
3 11 11.2 3 11 11.2 3 11 11.5 3 11 11.5
8 8 8 8
4 12 4 12 4 12 4 12
PORT GEARBOX (BY YANMAR) STBD GEARBOX (BY YANMAR)
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +10
Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat Panel
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 6
Hull KN6000-01 (MPC)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 wir.dwg P2199B16.W of 19 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
LOCAL REMOTE PORT PORT PORT STBD STBD STBD
CTRL. CTRL. AHEAD NEUTRAL ASTERN AHEAD NEUTRAL ASTERN
RESERVED
ID1
ID2
ID3
ID4
ID5
ID6
ID7
ID8
B B
OD1
OD2
OD3
OD4
OD5
OD6
OD7
OD8
C C
-PB1 1 5 2 6 1 5 2 6 5 6
LAMP =1F =2F
TEST -K5 -K5 -K3
9 10 9 10 5.2 8
Schutzvermerk nach DIN34 beachten
6.3 6.5
904
905
2 6 4 3 1 5 2 6 1 5 2 6
X405
D -K4 -K3 =1F =2F D
-K6 -K6
5.2 10 5.2 1 9 10 9 10
6.3 6.6
-X4. -X4. -X4. -X4. -X4. -X4. -X4. -X4. -X4.
3 4 6 7 8 9 10 11 5
102 24VDC-
6.8
EC05 12.3
E EC03 E
12.3
EC04 12.3
EC06 12.3
EC07 12.3
EC08 12.3
EC09 12.3
EC10
12.3
EC11
12.3
RCS-ECR
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +10
Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat Panel
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 7
Hull KN6000-01 (MPC)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 wir.dwg P2199B16.W of 19 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
RESERVED
1 5
-K4A
5.3 9
B POWER ALARM PORT AUX STBD AUX PORT THROTTLE STBD THROTTLE B
906
1
+
SAFETY STOP/
SAFETY STOP/
SAFETY STOP
SAFETY STOP
INTERLOCK
INTERLOCK
HIGH IDLE
HIGH IDLE
INTERLOCK
INTERLOCK
HIGH IDLE
HIGH IDLE
IGNITION
INPUT +
OUT GND
SIGNAL
4~20mA
SIGNAL
SIGNAL
SIGNAL
4~20mA
SIGNAL
SIGNAL
ALARM
OUT +
ALARM
START
START
OUT -
START
START
OUT -
0~10V
0~10V
-
GND
PWM
PWM
GND
PWM
PWM
IN
IN
IN
IN
C 2 C
+
-
3 1 2 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
908
909
Schutzvermerk nach DIN34 beachten
907
4 8
D -K4A D
5.3 12
1F-X107
1F-X108
2F-X107
2F-X108
1F-X201
1F-X202
2F-X201
2F-X202
13
-K7
14
=1F =2F =1F =2F
-X1. . -X1. . -X2. . . -X2. . .
7 8 7 8 1 2 3 1 2 3
E 202 24VDC- E
4.8
5
1 9 11.2 -X5 7 ECP -X5 7 ECS -X2 -X2
6 1 2 1 2
2 10
11.4
7 8 8
3 11 COMMON TRIP COMMON TRIP REFER TO DWG REFER TO DWG
8 P2199A2016 P2199A2016
4 12 REFER TO DWG REFER TO DWG
P2199A2016 P2199A2016 ASPP ASPS
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +10
Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat Panel
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 8
Hull KN6000-01 (MPC)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 wir.dwg P2199B16.W of 19 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
FORWARD
OUT GND
REVERSE
REVERSE
OUT GND
FORWARD
FORWARD
OUT GND
REVERSE
REVERSE
OUT GND
OUT +
OUT +
OUT +
OUT +
C C
1 2 3 4 1 2 3 4
STATION
1F-910
1F-911
1F-912
1F-913
2F-910
2F-911
2F-912
2F-913
Schutzvermerk nach DIN34 beachten
D D
13 7 13 7 13 7 13 7
=1F =1F =1F =1F =2F =2F =2F =2F
X5/+
X5/-
X501
X502
X503
X5/E
-K8 -K8A -K9 -K9A -K8 -K8A -K9 -K9A
14 2 (1.5S) 14 2 (1.5S) 14 2 (1.5S) 14 2 (1.5S)
MODE B MODE B MODE B MODE B
-X5. . -X5. . . .
+ - 1 2 3 E
E E
5 3 5 3 5 3 5 3
1 9 10.4 4 1 10.1 1 9 10.4 4 1 10.2 1 9 10.8 4 1 10.5 1 9 10.8 4 1 10.5 ECCU+
6 6 6 6 6 6 6 6 14.1
ECCU-14.1
2 10 5 8 2 10 5 8 2 10 5 8 2 10 5 8
10.2 10.3 10.6 10.6 ECCU1
7 7 7 7 14.1
3 11 3 11 3 11 3 11 ECCU214.1
8 8 8 8 ECCU314.1
4 12 4 12 4 12 4 12 RCS-ECR
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +10
Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat Panel
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 9
Hull KN6000-01 (MPC)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 wir.dwg P2199B16.W of 19 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A 2F-301 24VDC+ A
4.8
RESERVED
4 3 4 3 5 6 5 6 4 3 1 5 4 3 4 3 5 6 5 6 4 3 1 5
=1F =1F =1F =1F =1F =1F =2F =2F =2F =2F =2F =2F
-K8A -K9A -K8A -K9A -K10 -K8 -K8A -K9A -K8A -K9A -K10 -K8
COPYRIGHT
1 1 8 8 1 9 1 1 8 8 1 9
9.2 9.3 9.2 9.3 10.4 9.1 9.4 9.6 9.4 9.6 10.8 9.4
B B
1F+914
2F+914
1 5 1 5
=1F =2F
-K9 -K9
9 9
9.2 9.5
C C
Schutzvermerk nach DIN34 beachten
1F+915
2F+915
D D
1F-X302
1F-X303
1F-X306
1F-X305
2F-X302
2F-X303
2F-X306
2F-X305
=1F =1F =1F =1F =1F =1F 7 =2F =2F =2F =2F =2F =2F 7
-X3. -X3. -X3. -X3. -X3. -X3. =1F -X3. -X3. -X3. -X3. -X3. -X3. =2F
-K10 -K10
2 3 1 6 5 4 2 (1.5S) 2 3 1 6 5 4 2 (1.5S)
MODE B MODE B
2F-302 24VDC-
4.8
E 1F-302 24VDC- E
4.8
3 3
4 1 10.3 4 1 10.7
12 13 11 D3 D2 D1 6 12 13 11 D3 D2 D1 6
5 8 5 8
11-12: AHEAD D1-D2: DISENGAGE 11-12: AHEAD D1-D2: DISENGAGE
11-13: ASTERN D1-D3: ENGAGE 11-13: ASTERN D1-D3: ENGAGE
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
COPYRIGHT
B B
2 6 1 5 3 7 2 6 2 6 3 7
=1F =1F =2F =2F
-K7 -K7
-K1 -K5 -K1 -K5
10 8.2 9 11 10 8.2 10 11
4.5 6.3 4.7 6.5
1F+916
1F+918
2F+916
2F+918
Schutzvermerk nach DIN34 beachten
2 6 3 7 3 7 2 6 3 7 4 8
=1F =1F =2F =2F
-K4 -K4
D -K2 -K6 -K2 -K6 D
10 11 5.2 11 10 11 5.2 12
4.6 6.3 4.8 6.6
1F-X101
1F-X102
1F-X103
1F-X104
1F-X105
1F-X106
2F-X101
2F-X102
2F-X103
2F-X104
2F-X105
2F-X106
=1F =2F
-X1. . . . . . -X1. . . . . .
1 2 3 4 5 6 1 2 3 4 5 6
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
101 24VDC+.
DIN34
A A
RESERVED
D13
ID1
ID2
ID3
ID4
ID5
ID6
ID7
ID8
D13 D14 D15 D16 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12
NAFE-WH-00-01
D13
COM COM D14 D15 D16 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12
X105
X103
X104
X106
X107
X108
X109
X110
X111
C -PB2 C
LAMP/ 13
BUZ. 13.3 13.2 13.2 13.3 13.4 13.4 13.4 13.5 13.5
TEST
14
Schutzvermerk nach DIN34 beachten
102 24VDC-.
D D
-PB1
-F1 -F2
2A 2A EC05 CONTROL
7.7 POSITION
EC03
7.7 CONFIRM
EC04
7.7
7.7 EC06
7.7 EC07 13
X1/+.
X1/-.
7.7 EC08
7.7 EC09 14
7.7 EC10
-X1. . -X3. . 13.1
7.7 EC11
X101
X102
E E
+ - + - MPC 13.1
-X1. .
1 2
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +20
Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat Panel
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 12
Hull KN6000-01 (RCS-ECR)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 wir.dwg P2199B16.W of 19 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
COPYRIGHT
B B
CONTROL LOCAL REMOTE REMOTE PORT PORT PORT STBD STBD STBD
POSITION CNTRL. CNTRL. CONTROL AHEAD NEUTRAL ASTERN AHEAD NEUTRAL ASTERN
C CONFIRM REQUEST C
12.7
12.7 12.4 12.4 12.3 12.5 12.5 12.5 12.6 12.6 12.6
Schutzvermerk nach DIN34 beachten
X101
X102
X103
X104
X105
X106
X107
X108
X109
X110
X111
D -X3. . -X3. -X3. -X3. -X3. -X3. -X3. -X3. -X3. -X3. D
1 2 3 4 5 6 7 8 9 10 11
WH05 15.2
WH03 15.2
WH04 15.2
E WH06 E
15.2
WH07 15.2
WH08 15.2
WH09 15.2
WH10 15.2
WH11 15.2
WH02
15.7
WH01
15.7
RCS-WH
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +20
Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat Panel
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 13
Hull KN6000-01 (RCS-ECR)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 wir.dwg P2199B16.W of 19 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
(RCS-ECR)
STATION STATION
COPYRIGHT
B B
C C
Schutzvermerk nach DIN34 beachten
D D
X2/+
X2/-
X201
X202
X203
X2/E
X4/+
X4/-
X401
X402
X403
X4/E
-X2. . -X2. . . . -X4. . -X4. . . .
+ - 1 2 3 E + - 1 2 3 E
E E
ECCU+ WHCU+
9.8 16.1
9.8 ECCU- WHCU- 16.1
9.8 ECCU1 WHCU1 16.1
9.8 ECCU2 WHCU2 16.1
9.8 ECCU3 WHCU3 16.1
MPC RCS-WH
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +20
Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat Panel
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 14
Hull KN6000-01 (RCS-ECR)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 wir.dwg P2199B16.W of 19 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
.101 24VDC+
DIN34
A 1 5 A
-K1
9 15.8
RESERVED
108 DIMMER
2 6
-K1 -PB2
10 13
15.8 LOCAL REMOTE PORT PORT PORT STBD STBD STBD LAMP/
901
CNTRL. CNTRL. AHEAD NEUTRAL ASTERN AHEAD NEUTRAL ASTERN BUZ.
COPYRIGHT
107
ID1
ID2
ID3
ID4
ID5
ID6
ID7
ID8
D13 D14 D15 D16 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12
24V+ NAFE-WH-00-01
1 3 7
D13 COM D14 D15 D16 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12
BUZZER &
ID14.
COM
X103
X104
X106
X107
X108
X109
X110
X111
C DIMMERING C
MODULE
2 4 5 6
24V-
105
106
X105
4 8 3 7
13
Schutzvermerk nach DIN34 beachten
-X1. -S1 -X1. -X1. -X1. -X1. -X1. -X1. -X1. -X1.
-K1 -K1 -K1
15.8 12 5 15.8 11 3 4 6 7 8 9 10 11
14
.102 24VDC-
D D
-PB1
-F1 -F2 5
2A 2A WH05 CONTROL 1 9 15.3
13.5
WH03 POSITION 6
13.5 CONFIRM
WH04 2 10 15.3
13.5 7
13.5 WH06 3 11 15.3
13.5 WH07 13 8
13.5 WH08
.X1/+
.X1/-
4 12 15.2
13.5 WH09 14
13.5 WH10
-X1. .
13.5 WH11
X101
X102
E E
+ - RCS-ECR
-X1. .
1 2
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +30
Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat Panel
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 15
Hull KN6000-01 (RCS-WH)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 wir.dwg P2199B16.W of 19 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
(RCS-WH)
STATION STATION
COPYRIGHT
B B
TERMINATING
RESISTOR
C C
Schutzvermerk nach DIN34 beachten
D D
X2/+
X2/-
X201
X202
X203
X2/E
-X2. . -X2. . . .
+ - 1 2 3 E
E E
WHCU+
14.6
14.6 WHCU-
14.6 WHCU1
14.6 WHCU2
14.6 WHCU3
RCS-ECR
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +30
Drawn LingJing Vietnam MOA Remote Control
Email: Fishery Inspection Boat Panel
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 16
Hull KN6000-01 (RCS-WH)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 wir.dwg P2199B16.W of 19 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
P O R T M / E A L A R M P A N E L (E C P )
1F-X1 X5
1 2 X 2.5mm² 1
+ +
2 (BY YARD) 2 24V DC INPUT (SHIP SUPPLY)
- -
1 8 X 1mm² 1
1 1 F P P CONTROL FAIL
2 (BY YARD) 2 ( O P E N A T A LARM)
COPYRIGHT
2 2
3 3 CLUTCH ENGAGE SIGNAL
3 3
B 4 4 B
4 4 (CLUTCH ENGAGE CONTACT OPEN)
5 5
5 5 REMOTE CONTROL
6 6
6 6 (REMOTE CONTROL CONTACT CLOSE)
7 7
7 7 ENGINE TRIP
8 8
8 8 (CLOSE AT TRIP)
C 1F-X2 X2 C
1 2 X 1mm² 1
+ + + 2 POWER
2 (BY YARD) 2 P1
- - - 1 24V DC EP-
1 2 X 1mm² SCREEN 1 CONVERTER
1 (BY YARD) 1 + 3 CONTROL
2 2 P2
2 2 - 1 4-20mA
3 3 E
Schutzvermerk nach DIN34 beachten
P O R T G E A R B O X JU N C TI O N B O X (B Y YANMAR YXH2500)
1F-X3
D 1 10 X 1mm² 1 D
1 11 MAGNET V/V FOR CLUTCH POSITION CHANGEOVER
2 (BY YARD) 2
2 12 2 4 V D C , 1 . 2 5 A , R ATED 2SEC
3 3
3 13 11-12 : AHEAD, 11-13 : ASTERN
4 4
4 D1 M A G N E T V / V F O R C LUTCH ON/OFF CHANGEOVER
5 5
5 D2 24VDC, 1.25A, RATED 1.5SEC
6 6
6 D3 D1-D2 : DISENGAGE, D1-D3 : ENGAGE
7 7
7 A1
8 8 PRESS SW. FOR AHEAD DETECTION
8 A2
9 9
9 B1
10 10 PRESS SW. FOR ASTERN DETECTION
10 B2
E E
NOTE:
[*] ALL SPARE CABLE ARE TO BE
DETERMINE BY YARD
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
2F-X1 X5
1 2 X 2.5mm² 1
+ +
2 (BY YARD) 2 24V DC INPUT (SHIP SUPPLY)
- -
1 8 X 1mm² 1
1 1 F P P CONTROL FAIL
2 (BY YARD) 2 ( O P E N A T A LARM)
COPYRIGHT
2 2
3 3 CLUTCH ENGAGE SIGNAL
3 3
B 4 4 B
4 4 (CLUTCH ENGAGE CONTACT OPEN)
5 5
5 5 REMOTE CONTROL
6 6
6 6 (REMOTE CONTROL CONTACT CLOSE)
7 7
7 7 ENGINE TRIP
8 8
8 8 (CLOSE AT TRIP)
C 2F-X2 X2 C
1 2 X 1mm² 1
+ + + 2 POWER
2 (BY YARD) 2 P1
- - - 1 24V DC EP-
1 2 X 1mm² SCREEN 1 CONVERTER
1 (BY YARD) 1 + 3 CONTROL
2 2 P2
2 2 - 1 4-20mA
3 3 E
Schutzvermerk nach DIN34 beachten
S T B D G E A R B O X J U N C T I O N B O X ( B Y Y A N M A R Y X H2500)
2F-X3
D 1 10 X 1mm² 1 D
1 11 MAGNET V/V FOR CLUTCH POSITION CHANGEOVER
2 (BY YARD) 2
2 12 2 4 V D C , 1 . 2 5 A , R ATED 2SEC
3 3
3 13 11-12 : AHEAD, 11-13 : ASTERN
4 4
4 D1 M A G N E T V / V F O R C LUTCH ON/OFF CHANGEOVER
5 5
5 D2 24VDC, 1.25A, RATED 1.5SEC
6 6
6 D3 D1-D2 : DISENGAGE, D1-D3 : ENGAGE
7 7
7 A1
8 8 PRESS SW. FOR AHEAD DETECTION
8 A2
9 9
9 B1
10 10 PRESS SW. FOR ASTERN DETECTION
10 B2
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
X4 X1 X3 X1
1 2 X 2.5mm² 1 1 2 X 2.5mm² 1
+ + + +
2 (BY YARD) 2 2 (BY YARD) 2
- - - -
1 11 X 1mm² 1 1 11 X 1mm² 1
1 1 1 1
2 (BY YARD) 2 2 (BY YARD) 2
COPYRIGHT
2 2 2 2
3 3 3 3
3 3 3 3
B 4 4 4 4 B
4 4 4 4
5 5 5 5
5 5 5 5
6 6 6 6
6 6 6 6
C C
X5 X2 X4 X2
1 2 X 1mm² 1 1 2 X 1mm² 1
+ + + +
2 (BY YARD) 2 2 (BY YARD) 2
- - - -
1 3 X 1mm² SCREEN 1 1 3 X 1mm² SCREEN 1
1 1 1 1
2 (BY YARD) 2 2 (BY YARD) 2
2 2 2 2
3 3 3 3
Schutzvermerk nach DIN34 beachten
3 3 3 3
E E E E
CONTROL PANEL
D D
( R C S - E C R)
REMOTE
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A
Material List A
RESERVED
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A
Material List A
RESERVED
+10-X5
B 27 038356 Terminal End Bracket EW-35 +10- 3 B
28 3038503 Terminal End Plate D-STTBS 2,5 +10- 8
29 160880 Terminal Fuse End Plate ZAP/TW 3 +10- 1
30 161640 Terminal Fuse Holder ZSI2.5 =1F+10-F5, =1F+10-F6, =1F+10-F7 10
=1F+10-F8, =2F+10-F5, =2F+10-F6
=2F+10-F7, =2F+10-F8, +10-F1, +10-F2
31 R419801320 Throttle Control Cable, 4~20mA,10M +10- 2
C C
Schutzvermerk nach DIN34 beachten
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A
Material List A
RESERVED
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A
Material List A
RESERVED
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
RESERVED
N3000-SAP
Shipyard :
Vessel Name:
*Notes:
IMO No. :
1. As Built (FAT / In-House) 2. Commissioning 3. As Built (Final) 4. Service
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
WH
DIN34
A PORT STBD A
M / E A L A R M P AN EL M / E A L A R M P AN EL
(WHP) REMOTE CONTROL PANEL (WHS)
G1
N1
G2
( R C S - W H) G2
N2
G1
RESERVED
PB1 H3 H2 H1 H1 H2 H3 PB1
ECR ER
C C
REMOTE CONTROL PANEL
( R C S - E C R)
PORT REMOTE CONTROL PANEL (RCS-ECR) STBD
H3 H6
H4 H7
H5 H8
Schutzvermerk nach DIN34 beachten
PORT PORT
M / E A L A R M P AN EL
A1
M / E A L A R M P AN EL M/E ALARM SIREN COMBI.FLASHER
HORN
H1 H2 PB1 PB2
(ECP) YANMAR (ECS) & R O T A T I N G L I G H T JB
N1
REFER TO DRAWING N2
24VDC
N1
2 2 0 V AC 2 2 0 V AC
M
a
i
nE
n
gi
n
e M
a
i
nE
n
gi
n
e M
a
i
nE
n
gi
n
e M
a
i
nE
n
gi
n
e M
a
i
nE
n
gi
n
e M
a
i
nE
n
gi
n
e
A A
S
t
a
tu
sP
i
c
k-
U
p1
/
O
ve
r
s
p. S
t
a
tu
sP
i
c
k-
U
p1
/
O
ve
r
s
p.
MAIN MAIN
L
u
b
.O
i
lP
r
e
s.L
o
w10
6 S
t
a
tu
sP
i
c
k-
U
p2
/
O
ve
r
s
p. L
u
b
.O
i
lP
r
e
s.L
o
w10
6 S
t
a
tu
sP
i
c
k-
U
p2
/
O
ve
r
s
p.
C
ol
.
W
at
.P
r
e
s.H
T2
1
0
3 E
n
g
in
eR
un C
ol
.
W
at
.P
r
e
s.H
T2
1
0
3 E
n
g
in
eR
un
L
u
b
.O
i
lG
e
a
rP
r
es.L
o
w L
u
b
.O
i
lG
e
a
rP
r
es.L
o
w
B
a
te
r
y1 B
a
te
r
y1
B
a
te
r
y2 B
a
te
r
y2
STBD
N3000-SAP N3000-SAP
E E
PORT
M / E A I R S O U R C E P A NEL
(ASPP)
F 1 As Built 01.11.2016 LingJing Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +
0 AFC 07.09.2016 LingJing Drawn LingJing Vietnam MOA Alarm & Safety
Email: Fishery Inspection Boat System
A For Approval 05.08.2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 1
Hull KN6000-02 Block Diagram
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.O of 1 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
300 mm
AS BUILT
280 mm 120 mm
01 NOV 2016
DIN34
A 6XØ5 mm A
N1 / N2
RESERVED
230 mm
NAMEPLATE TEXT DESCRIPTION
480 mm
MainEngine MainEngine MainEngine INSUL.
N1. P O R T M / E A L A R M P A N E L (E C P )
Emergency Stop ECR OilMistConcentrat. 1253 Status Pick-Up 1/Oversp.
N2. S T B D M / E A L A R M P A N E L ( E C S )
COPYRIGHT
Emergency Stop Bridge Lub. Oil Press. Low 1106 Status Pick-Up 2/Oversp. RESET
N3. WARNING:
Emergency Stop Local Autostop from Start-Stop Reset Remote
ShutDown Valve 1 OverrideOil Mist Concentr. Battery1
230 mm
Emergency System Autostop System SpeedSystem
N3000-SAP
RESET ON SAFETY SYSTEM BEFORE STARTING
OF ENGINE.
N3
M/E
N3000 ALARM DISPLAY
RPM CABLE
CONNECTION
YANMAR
- ENGINE OVERSPEED TRIP
- E N G I N E LU B E OIL PRESS LOW TRIP
- ENGINE EMERGENCY STOP
FRONT VIEW SIDE VIEW
C - ENGINE FAIL TO START C
2M - ENGINE LUBE OIL PRESS LOW
600 mm - NO.2 L.O.FILTER PRESS HIGH
550 mm 140 mm - ENGINE FRESH WATER TEMP HIGH
4XØ10 mm - ENGINE FUEL OIL LEAK TANK LEVEL HIGH
Schutzvermerk nach DIN34 beachten
DC/DC
- GEARBOX LUBE OIL PRESS LOW
TRUNKING
- FPP CONTROL FAILURE
- ENGINE CONTROL AIR PRESS LOW
- ENGINE STARTING AIR PRESS LOW [*]
D D
FUSE
FUSE
TRUNKING
RDU
AC/DC
- ENGINE CONTROL AIR VALVE SHUT [*]
- MAIN POWER FAILURE
TRUNKING - BACKUP POWER FAILURE
550 mm
600 mm
- SAP SYSTEM FAULTY/ WIRE BREAK
TRUNKING
TRUNKING (AC)
TRUNKING
E SPECIFICATIONS E
TRUNKING
1. COLOUR : BLACK
2. PROTECTION CLASS : IP22
CB2
CB2
CB1
CB1
NOTE:
DRAWING SHOW FOR ONE ENGINE ONLY,
THE OTHER ENGINE IS IDENTICAL.
[*] APPLY FOR PORT ENGINE ONLY. BASEPLATE SIDE VIEW
F 1 As Built 01.11.2016 LingJing Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +20
0 AFC 07.09.2016 LingJing Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (ECP & ECS)
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 1
Hull KN6000-02
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.P of 6 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
4XØ5 mm 4XØ5 mm
A A
N1 N2
G1 G2 G2 G1
RESERVED
270 mm
270 mm
290 mm
290 mm
CONNECTION
COPYRIGHT
G3 G3
B B
PB1 H3 H2 H1 H1 H2 H3 PB1
C C
FRONT VIEW FRONT VIEW SIDE VIEW
NAMEPLATE TEXT DESCRIPTION
2M 2M
250 mm 250 mm N1. P O R T M / E A L A R M P A N E L ( W H P )
200 mm 200 mm N2. S T B D M / E A L A R M P A N E L ( W H S )
Schutzvermerk nach DIN34 beachten
4XØ10 mm 4XØ10 mm
TRUNKING TRUNKING G1. M/E FRESH WATER TEMP. GAUGE
G2. M / E LU B E OIL PRESS. GAUGE
G3. M/E TACHOMETER
D D
250 mm
300 mm
300 mm
H1. M/E COMMON TRIP - RED
TRUNKING
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
AS BUILT
01 NOV 2016
DIN34
A A
NAMEPLATE TEXT DESCRIPTION
RESERVED
B B
250 mm 100 mm
232 mm
4XØ6 mm
C C
N1
132 mm
150 mm
Schutzvermerk nach DIN34 beachten
D D
E E
SPECIFICATIONS
1. COLOR : GREY
2. MATERIAL : ABS
3. PROTECTION CLASS : IP66
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
SPECIFICATIONS
1. WEIGHT : 0.4KG
2. COLOUR : AMBER
COPYRIGHT
109 mm
B 3. D B O U TPUT : 110dB B
4. P A R T N O . : 9 5 8 C H X 1 2 0 1
5. P O W E R SUPPLY : 24VDC
6. P R O T E C T I O N C L A S S : I P 6 6
7. POWER CONSUMPTION : <2W
8. T E M P E R A T U R E R A N G E : - 4 0 ~ 7 0 ° C
C C
FRONT VIEW SIDE VIEW
92 mm
Schutzvermerk nach DIN34 beachten
Slot x 4
4.5
D D
46 mm 4XØ4.5
48 mm
62 mm
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
NO. PARTS NAME NO. PARTS NAME
1 Y - STRAINER 8 MAG VALVES ( FOR REMOTE CONTROL)
2 B A L L VALVES 9 MAG VALVES ( FOR GOV HOLD) AS BUILT
3 P R E S S R E G U L A T O R ( S E T @ 7 . 5 BAR) 10 E-P CONVERTOR
01 NOV 2016
DIN34
7 13
10
COPYRIGHT
4 4 11
3 3
B B
6 6 12
2 2 460 500 460500
5 5
1 1
8 9
C C
900
D 4XØ10 mm 860 D
7 13
10
11
12
460500
5 5
E E
8 9
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
NO. PARTS NAME NO. PARTS NAME
1 Y - STRAINER 8 MAG VALVES ( FOR REMOTE CONTROL)
2 B A L L VALVES 9 MAG VALVES ( FOR GOV HOLD)
3 P R E S S R E G U L A T O R ( S E T @ 7 . 5 BAR) 10 E-P CONVERTOR
DIN34
4
COPYRIGHT
3 1
B 6 2 B
FROM STARTING AIR RESERVOIR STBD
(30 BAR MAX.)
4
6 3 1
6 2
FROM STARTING AIR RESERVOIR PORT
(30 BAR MAX.)
GOVERNOR
C 13 12 C
8 9
5 5 10
STOP V/V
E/P
F.O.LIMIT
Schutzvermerk nach DIN34 beachten
7
PORT AIR SOURCE PANEL PORT M/E
D D
GOVERNOR
13 12 8 9
10
5 5 STOP V/V
E/P
F.O.LIMIT
7
STBD AIR SOURCE PANEL PORT M/E
E E
REMARKS:
1. PIPING MARKED WITH ----- SHOW THE FITTING PIPES
2. FITTING PIPES IN USED = OUTDIA. 10mm COPPER PIPE
3. CONTROL AIR PRESS = 7 Bar
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +
Drawn LingJing Vietnam MOA M\E
Email: Fishery Inspection Boat Air Source Pl.
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 6
Hull KN6000-02 (ASPP & ASPS)
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 (Piping dwg) P2200A16.P of 6 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Revision History:A
DIN34
A A
Date Revision Page
1 05.08.2016 LingJing For Approval P2200A16_O.0001
RESERVED
COPYRIGHT
B B
C C
Schutzvermerk nach DIN34 beachten
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Revision History:B
DIN34
A A
Date Revision Page
1 19.08.2016 LingJing Revised - add in remote start / stop PB in WH drop in panel P2200A16_M.0001
RESERVED
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Revision History:0
DIN34
A A
Date Revision Page
1 07.09.2016 LingJing AFC - add in "twice start prevention" cct P2200A16_M.0001
RESERVED
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Revision History:1
DIN34
A A
Date Revision Page
1 01.11.2016 LingJing As Built P2200A16_M.0003
RESERVED
B B
C C
Schutzvermerk nach DIN34 beachten
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
SYMBOL LEGEND
RESERVED
4-20mA
C STOP C
PRESSURE TRANSMITTER
FUSE
NORMALLY OPEN PUSH BUTTON
FLASHER
D LAMP D
NORMALLY CLOSE PUSH BUTTON
RESISTOR
D1 DIODE
P NORMALLY OPEN PRESSURE SWITCH
13 VARISTOR
RELAY NORMALLY CLOSE PRESSURE SWITCH
P
14
E 7 E
TIME RELAY NORMALLY OPEN TEMPERATURE
SWITCH POTENTIOMETER
2
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
D D
.
.
Panel(s) \ Equipment(s)
Externally Connected
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
111
112
B B
-N3
+ -
Out In
+ -
101 24VDC+
102 24VDC-
101
102
16.1
WHP
010
020
030
040
D
-N1 D
+ DC
-
G
L AC N
XP/E
001
002
-X1
L N E + - + -
24VDC
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
RESERVED
-X3.
19
-G1
COPYRIGHT
WH16
20.3
ENG. WH17
B TACHOMETER 20.3 B
WH18
20.3
WH19
20.3
WH20
20.3
YASC
RPM WHP
+ - -X3 -X3
. 16 . 17 . 18 . 20
C C
Schutzvermerk nach DIN34 beachten
SAP.3.15
10.7 10.8
D SAP.3.16 D
SAP.3.13
SAP.3.14
10.7 10.8
X316
X317
X318
X320
-X10. . -X3. . . -E1. . . -E1. . . -E1. .
1 2 1 2 3 31 32 33 28 29 30 26 27
[OPTIONAL]
E 202 24VDC- E
3.8 5.1
4-20mA
WH02 20.3 F.W. L.O.
ENGINE TACHOMETER TEMP. PRESS.
WHP
SENSOR 46 TX. 92
PORT ENG.JB 47
(BY YANMAR)
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +20
0 AFC 07.09.2016 LingJing Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (ECP & ECS)
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 4
Hull KN6000-02 wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
RESERVED
COPYRIGHT
B B
1 5
-K2
5.4 9
C C
Schutzvermerk nach DIN34 beachten
START REMOTE
D INTERLOCK CONTROL D
E108
E109
X506
X701
X704
13 13
-K1 -K2
14 -E1. . -X5. . -X5. . 14 -X7. . -X7. . -X7. .
8 9 3 4 5 6 1 2 3 4 5 6
E 202 24VDC- E
4.8 6.1
5 5
1 9 6.3 18 -X1 3 -X1 5 1 9 5.5 -X1 -X1 -X1
6 6 1 2 3 4 5 6
2 10 TURNING CLUTCH REMOTE 2 10 CONTROL GOVERNOR CONTROL
8.3 GEAR ENGAGE 4 CONTROL 6 6.3
7 19 7 TRANSFER HOLD AIR PRESS.
3 11 12.6 ENGAGE =OPEN 3 11 8.3 SOLENOID SOLENOID SW.FOR
=OPEN PORT
8 REFER TO DWG P2200B2016 8 GOV.HOLD
4 12 16.3 ENG.JB 4 12 16.3
(BY YANMAR) MPC PORT M/E AIR SOURCE PANEL (ASPP)
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +20
Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (ECP & ECS)
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 5
Hull KN6000-02 wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
RESERVED
1 5 1 5 2 6 1 5 1 5 1 5 2 6 2 6
-K1 -K15 -K18A -K16A -K11 -K3 -K20
5.1 9 8.3 9 9.3 10 8.5 9 7.6 9 6.1 9 10 6.7 10
922
901
COPYRIGHT
B 1 5 1 5 2 6 B
920
-K20 -K19
6.7 9 6.7 9 10
902
923
1 5 4 3 5 6
-K10 -K21
7.6 9 6.8 1 8
903
C C
1 5
-K18A
9.3 9
905
904
Schutzvermerk nach DIN34 beachten
921
924
2 6
-K2
5.4 10 TWICE
D START D
PREVENTION
E105
E110
E112
E114
13 13 13 7
-K3 [NOT IN USED] -K19 -K20 -K21
(10S)
14 -E1. . -E1. . -E1. . -E1. . -E1. . 14 14 2 MODE A
4 5 6 7 10 11 12 13 14 15
E 202 24VDC- E
5.8 12.3
5 5 5 3
1 9 6.7 11 13 1 9 6.7 1 9 6.3 4 1 6.7
6 20 21 22 23 26 27 6 6 6
2 10 START VALVE STOP VALVE F.O.RACK 2 10 2 10 5 8
6.8 6.7 6.8 6.7
7 12 14 (M/E) (M/E) LIMIT VALVE 7 7
3 11 START HANDLE SW. 3 11 3 11
8 BUTTON (RESET=OPEN) 8 8
4 12 4 12 4 12
PORT ENG.JB (BY YANMAR)
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +20
0 AFC 07.09.2016 LingJing Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (ECP & ECS)
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 6
Hull KN6000-02 wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A 201 24VDC+ A
6.8 8.1
RESERVED
COPYRIGHT
B B
C C
Schutzvermerk nach DIN34 beachten
SAFETY SYSTEM ENGINE RESET SIREN COMMON COMMON ENGINE FO RACK COMMON SAFETY SYSTEM
D FAULTY/ RUN FAULT FAULT RUN LIMIT V/V TRIP FAULTY/ D
WIRE BREAK (400RPM) (FLICKER) (125RPM) (FLICKER) WIRE BREAK
(FLICKER)
13 13 13 13 13 13 13 13 13 13
-K4 -K5 -K6 -K7 -K8 -K9 -K10 -K11 -K12 -K13
14 14 14 14 14 14 14 14 14 14
SAP.3.1 SAP.4.8 SAP.4.9 A0X.1.9 A0X.1.11 A0X.1.13 A0X.2.9 A0X.2.11 A0X.2.13 A0X.2.15
10.5 11.3 11.3 12.3 12.3 12.4 12.7 12.7 12.8 12.8
E E
5 5 5 5 5 5 5 5 5 5
1 9 12.1 1 9 16.5 1 9 8.7 1 9 16.3 1 9 16.8 1 9 16.2 1 9 6.3 1 9 6.5 1 9 16.1 1 9 16.2
6 6 6 6 6 6 6 6 6 6
2 10 2 10 2 10 2 10 2 10 2 10 2 10 2 10 2 10 2 10
16.7 16.6 12.2 16.5 8.3
7 7 7 7 7 7 7 7 7 7
3 11 3 11 3 11 3 11 3 11 3 11 3 11 8.5 3 11 3 11 3 11
8 8 8 8 8 8 8 8 8 8
4 12 4 12 4 12 4 12 4 12 4 12 4 12 16.3 4 12 4 12 4 12
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +20
Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (ECP & ECS)
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 7
Hull KN6000-02 wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
3 7
-K2
RESERVED
5.4 11
-X1.
X312
1
-X3. .
12 14 WH12
2 6 19.5 3 7 5 6 1 5
COPYRIGHT
WH13 19.5
-K15 WH14 -K16A -K15T -K17
B [NOT IN 19.5 B
8.3 10 WH15 8.5 11 8.4 8 8.7 9
USED] 19.5
-X3 WHP
X313 . 13 . 15
-X1
. 2 2 6
-K1
913
5.1 10
X315
906
C C
2 6 3 7 1 5
-K10 -K6
7.6 10 11 7.3 9
907
911
Schutzvermerk nach DIN34 beachten
1 5 4 3 4 3
-K18B -K15T -K16T
9.4 9 1 1
8.4 8.6
908
912
914
ENGINE ENGINE START
910
-K16A
8.5 10
13 7 13 13 7 13
909
E 302 24VDC- E
3.8 9.1
5 3 5 5 3 5
1 9 6.4 4 1 8.3 1 9 6.5 1 9 16.4 4 1 8.5 1 9 8.7
6 6 6 6 6 6
2 10 5 8 2 10 2 10 5 8 2 10
8.2 8.7 8.3 10.1
7 7 7 7
3 11 3 11 8.6 3 11 3 11
8 8 8 8
4 12 4 12 12.6 4 12 4 12
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F 1 As Built 01.11.2016 LingJing Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +20
0 AFC 07.09.2016 LingJing Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (ECP & ECS)
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 8
Hull KN6000-02 wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A
N3000-SAP [X1] N3000-SAP [X6] N3000-SAP [X7] N3000-SAP [X8] A
Batt.1 Batt.2 - 1 - - 2 -
. . . . . . . . . . . . . .
1 2 3 4 1 2 3 4 1 2 3 1 2 3
COPYRIGHT
B [+] [-] [-] [+] [+] [-] [-] [+] [-] [Q] [+] [-] [Q] [+] B
301 24VDC+
302 24VDC-
402 24VDC-
401 24VDC+
SAP.6.1
SAP.6.2
SAP.6.3
SAP.6.4
E102
E101
3.8
8.8 10.5
3.8
C 3.8 C
Schutzvermerk nach DIN34 beachten
D D
-E1. . .
13 13
-K18A -K18B 2 1 3
14 14
E E
5 5
1 9 6.3 1 9 8.3
6 6 05 04 06
2 10 2 10 ENGINE MPU
6.4 16.4
7 7
3 11 16.4 3 11 NO.OF TEETH: 289
8 8 IDLE SPEED: 400RPM
4 12 16.7 4 12 RATED SPEED: 750RPM
PORT ENG.JB (BY YANMAR)
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +20
Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (ECP & ECS)
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 9
Hull KN6000-02 wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A Input: Input: Input: Input: Input: Input: Input: Input: Output: Output: Output: Output: Output: Output: Output: Output: A
Fail To AS2 L.O.Prs. AS4 WH ES2 ES3 ES4 Autostop Speed E.Stop Autostop Overspeed E.Stop Analog Analog
Start Low Trip E.Stop System System System Activated Activated Activated 4~20mA 0~10V
RESERVED
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
COPYRIGHT
302 24VDC-
B B
SAP.3.13
SAP.3.14
SAP.3.15
SAP.3.16
SAP.2.1
SAP.2.2
SAP.3.1
A0X.3.1
A0X.3.2
A0X.3.7
A0X.3.8
E134
E135
E120
E121
X601
X602
X310
X311
X201
X202
X203
X204
X205
X206
7.2 13.2
9.2 11.2 13.2
13.1
2 6 13.1
C -K17 22K 4.2 C
8.7 10 Ohm 4.2
4.4
4.4
Schutzvermerk nach DIN34 beachten
D D
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +20
Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (ECP & ECS)
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 10
Hull KN6000-02 wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A Output: Output: Common Output: Input: Output: Output: Output: Output: Output: Input: Input: Input: Output: A
System Failure Wire SHD & Reset
Override AS5 Frequency Fail To AS2 L.O.Prs. AS4 Override Override Reset Frequency
Syst.F
E.Stop
Syst.F
Firing
/Reset
Emerg.
2 Mode Pickup Start Low Trip AS1 AS2~AS4 Remote Pickup
Term.
Term.
Speed
RESERVED
Auto
Stop
8~12
Auto
Stop
Stop
O/S
3~5
Pre
SHD
O/S
SHD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
COPYRIGHT
[+] [+] [+] [-] [-] [+] [+] [+] [+] [+] [+] [-] [Q] [-] [+] [-] [+] [-] [+] [-] [Q] [-]
B B
302 24VDC-
SAP.4.16
A0X.3.10
SAP.4.8
SAP.4.9
A0X.1.8
A0X.2.7
A0X.2.8
A0X.3.5
A0X.3.6
A0X.3.3
A0X.3.4
A0X.3.9
22k 22k 22k 22k
Ohm Ohm Ohm Ohm
D D
E E
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +20
0 AFC 07.09.2016 LingJing Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (ECP & ECS)
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 11
Hull KN6000-02 wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A Inhibit A
Remarks
RESERVED
Limit: Limit:
<400RPM >600RPM
COPYRIGHT
B B
Output: Output: Output Output: Output Output Output Output
Description
ME. ME. ME. Horn ME. ME. N3000 ME. ME. ME. ME. ME. ME. ME. ME.
SAP Sys. Reset Speed Common Common A05 Fail. Main Backup Start Fail To Run FO Rack Common SAP Sys.
F./WB Fault Fault Pow.Fail Pow.Fail Int'Lock Start (125RPM) Lim.V/V Trip F./WB
(Flicker) (Flicker) (Flicker)
. . . . . . . . . .
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
. . . . . . . . . . . . . . . . . . . . . .
C C
A0X.1.1
A0X.1.2
A0X.1.5
A0X.1.6
A0X.1.8
A0X.2.1
A0X.2.2
A0X.2.3
A0X.2.4
A0X.2.5
A0X.2.6
A0X.2.7
A0X.2.8
1 5 2 6 3 7
202 24VDC-
202 24VDC-
202 24VDC-
202 24VDC-
202 24VDC-
202 24VDC-
202 24VDC-
Schutzvermerk nach DIN34 beachten
A0X.1.11 3.2
A0X.1.13
A0X.2.11
A0X.2.13
A0X.2.15
-K4 -K6 -K1
A0X.1.9
A0X.2.9
3.2
9 7.2 10 7.3 11 5.1
915
3.2
4 8
D 3.2 D
-K16A
12 8.5
11.5 17.2
11.5
11.5
7.4 7.5 7.5 7.6 7.7 7.7 7.8
6.8 12.7 12.4 17.1
E E
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +20
0 AFC 07.09.2016 LingJing Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (ECP & ECS)
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 12
Hull KN6000-02 wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
>150RPM
RESERVED
On Delay
10 Min
Pt. & Range
Alarm Set
Limit:
>900RPM
COPYRIGHT
B B
Description
ME. ME. ME. ME. ME. ME. ME. ME. GB. ME. ME. ME.
O/Speed L.O.Prs. Emerg. L.O. N2 LO F.W. F.O. FPP L.O.Prs. Cntrl.Air Start.Air Cntrl.Air
Trip Low Trip Stop Prs. Low Filter Temp. Hi Leak T. Cntrl. Low Prs.Low Prs.Low V/v Shut
Prs. Hi Lvl. Hi Fail [*] [*]
. . . . . . .
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
. . . . . . . . . . . . . . . . . . . . . . . . .
C C
A0X.3.10
A0X.3.11
A0X.3.12
A0X.3.13
A0X.3.14
A0X.3.15
A0X.3.16
A0X.4.10
A0X.4.11
A0X.4.12
A0X.4.13
A0X.4.14
A0X.4.15
A0X.4.16
A0X.3.1
A0X.3.2
A0X.3.3
A0X.3.4
A0X.3.5
A0X.3.6
A0X.3.7
A0X.3.8
A0X.3.9
A0X.4.1
A0X.4.2
A0X.4.3
A0X.4.4
A0X.4.5
A0X.4.6
A0X.4.7
A0X.4.8
A0X.4.9
Schutzvermerk nach DIN34 beachten
10.7
10.7
11.6
11.6
11.6
D D
11.6
10.7
10.7
11.7
11.7
-E1. . -E1. . -E1. . -E1. . -X5. . -X6. . -X7. . -E2. . . . -E1. . -E1. .
22 23 18 19 24 25 16 17 1 2 3 4 7 8 1 2 3 4 36 37 38 39
E E
75 51 B1 41 1 31 -X1 7
P P P P
76 52 B2 42 2 32 8
PORT GB P
NOTE:
[*] APPLY FOR PORT ENGINE ONLY (BY
PORT ENG.JB (BY YANMAR) MPC YANMAR) ASPP
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +20
1 As Built 01.11.2016 LingJing Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (ECP & ECS)
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 13
Hull KN6000-02 wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Limit:
COPYRIGHT
>O/P
B B
Description
C C
Schutzvermerk nach DIN34 beachten
D D
E E
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +20
Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (ECP & ECS)
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 14
Hull KN6000-02 wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
COPYRIGHT
B B
C C
1H 2L 3G 1H 2L 3G
CAN 1
CAN 2
1H 2L 3G 1H 2L 3G
X3
X4
Schutzvermerk nach DIN34 beachten
D D
E E
OPTIONAL
(APPLICABLE ONLY WHEN MINITERMINAL IS INSTALLED.)
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +10
Drawn LingJing Vietnam MOA CANBUS
Email: Fishery Inspection Boat Connection
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 15
Hull KN6000-02 Diagram
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
BUZZER BUZZER
SIGNAL SIGNAL
DIN34
A A
1 5 2 6
RESERVED
-K7 -K7
7.4 9 7.4 10
X304
X305
X401
X402
-X3. . -X4. .
COPYRIGHT
B 4 5 1 2 B
WH04 SR01
19.2 21.3
WH05 SR02
19.2 21.3
WH06 S.&R. JB
19.4
WH07
19.4
WH08
19.4
WH09
19.4
WHP
C C
-X3
. 6 . 7 . 8 . 9
X309
Schutzvermerk nach DIN34 beachten
919
D D
X306
X307
X308
4 8 1 5 3 7 1 5 2 6 2 6 4 8 1 5
-K2 -K16B -K18A -K5 -K5 -K4 -K18A -K8
5.4 12 8.5 9 9.3 11 7.2 9 7.2 10 7.2 10 9.3 12 7.4 9
916
918
X507
X508
X801
X802
X901
X902
X903
X904
X905
X906
X907
X908
1 5 1 5 1 5 4 8
-K12 -K9 -K13 -K1
7.7 9 7.5 9 7.8 9 5.1 12 -X5. . -X8. . -X9. . . . . . . .
7 8 1 2 1 2 3 4 5 6 7 8
E 102 24VDC- E
3.8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
RESERVED
11.5
12.3
A0X.1.8
N3000-DSP
Unit A05.5
-TB.
COPYRIGHT
1 X6
B B
4.7k
Ohm X1
X7 18...32 VDC
-TB.
SAP.4.16
2 + - + -
A0X+
+ -
N3000-IMC
Unit A05.1 X5
C C
Vout
X2 X6
X1
18...32 VDC X7
Schutzvermerk nach DIN34 beachten
+ - + -
D D
[YELLOW\
[WHITE]
[BROWN]
GREEN]
-KM131-31. . .
1 2 3
E 202 24VDC- E
12.8
[OPTIONAL]
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +20
Drawn LingJing Vietnam MOA Unit A05 & A07
Email: Fishery Inspection Boat Power & I-Bus
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 17
Hull KN6000-02 Connection
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A05.1
RESERVED
Motherboard
Channel 5-8 Card-Type SA655-40G Plug X42
Card-Type
SA646-10G X40
COPYRIGHT
X30
Channel 1-4 Card-Type SA655-40G Plug X31
C C
X20
SA648-1G
Channel 1-4 Card-Type SA655-40G Plug X21
D D
E
Remarks IMC ADDRESS: MODBUS Interface (RTU) E
CPU Master PORT M/E : A05 Noris: Slave
Card Type SA650-21G
STBD M/E : A07 Remote: Master
Data Bits: 8
Firmware N3_ALA_114kb.MOT Parity: None
Stop Bit: 1
Bauds Rate: 9600
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +20
Drawn LingJing Vietnam MOA N3000
Email: Fishery Inspection Boat Master Unit
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 18
Hull KN6000-02 A05.1 & A07.1
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A 1 5 A
-X1.
4 -K2 19.2
9 19.8
RESERVED
X105.
16.4
WH05 2 6
16.4
ECP
-K2 -PB2 -PB1
-X1 10 2 6
19.8 COMMON COMMON SAFETY BUZZER LAMP/
901
. 5 TRIP FAULT SYSTEM -K1 ACK. BUZ.
COPYRIGHT
FAILURE 10 TEST
X105.
19.7
B 19.7 -F3 -H1 -H2 -H3 B
1A
1 5 19.3
19.8
ID6.
-K1
ID1
ID2
ID3
ID4
19.7 9
OD6.
207 D5 D6 D7 D8 D1 D2 D3 D4
19.3
24V+ NAFE-WH-01-02
1 3 7
D5 COM D6 D7 D8 D1 D2 D3 D4
BUZZER &
OD6.
ID6.
COM
OD1
OD2
OD3
OD4
902
C DIMMERING C
MODULE 2
2 4 5 6
19.2 -X1. . . .
24V-
205
206
6 7 8 9
3 7 WH06
16.4 13 13
Schutzvermerk nach DIN34 beachten
-S2 WH07
-K2 16.4 -K1 -K2
11 WH08
19.8 16.4
WH09 14 14
16.4
ECP
.102 24VDC-
D 20.1 D
EMERGENCY READY/ STOP
-F1 -F2 STOP START 5 5
2A 2A 1 9 19.2 1 9 19.2
6 6
22K -PB3 -PH1 -PB4 2 10 19.7 2 10 19.2
Ohm 7 7
[*] 3 11 3 11 19.3
X1/+
X1/-
8 8
4 12 4 12
X110
X111
X112
X113
X114
X115
-X1. .
E -X1. . . . . . E
+ -
WH10 10 11 12 13 14 15
10.5
WH11
10.5
8.5 WH12
8.5 WH13
3.4 WH+ 8.5 WH14
3.4 WH- 8.5 WH15
ECP ECP
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +30
0 AFC 07.09.2016 LingJing Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (WHP & WHS)
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 19
Hull KN6000-02 wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
RESERVED
COPYRIGHT
B B
C DIMMERING RPM
C
MODULE 1
2 4 5 6 + - N A B B L + -
24V-
105
106
Schutzvermerk nach DIN34 beachten
-S1
D D
X101
X102
X116
X117
X118
X119
X120
-X1. . . -X1. . . -X1. .
1 2 3 16 17 18 19 20
E .102 24VDC- E
19.8
WH01
4.3
WH02
4.3
WH16
4.6
WH17
4.6
WH18
4.6
WH19
4.6
WH20
4.6
ECP
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com =1F +30
0 AFC 07.09.2016 LingJing Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (WHP & WHS)
B Revised - For Approval 1 9 . 0 8 . 2016 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 20
Hull KN6000-02 wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
..101 24VDC+
DIN34
A A
RESERVED
1 5
-K1
21.5 9
COPYRIGHT
B B
C C
13
Schutzvermerk nach DIN34 beachten
-K1
X102
X105
14
..102 24VDC-
D D
-F1 5
0.2A -X1. . -X1. .
1 9 21.6 -X1. .
1 2 3 4 6 5 6
2 10
XP/+
7
3 11
8
4 12
-XP. .
+ - 16.5 SR01
E 16.5 SR02 E
ECP
-X4
+ - 1 2
BUZZER
24VDC SIGNAL
POWER SUPPLY COMBI.
(BY YARD) ECS NOTE:
FLASHER HORN [*] THIS PAGE SHOW FOR ALL ENGINE.
DESIGN SHOWN POWER OFF STATE & ENGINE IN STOP CONDITION; IF APPLICABLE
F Date 05.08.2016 Customer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +50
Drawn LingJing Vietnam MOA M/E Alarm
Email: Fishery Inspection Boat Sounder & Rotat.Light
Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 21
Hull KN6000-02 JB wir.dwg
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.W of 29 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 12 X 1mm² 1 3 3
4 4 6 13 HANDLE SWITCH
2 (BY YARD) 2 4 4
5 5 7 14 (C LOSE AT RUN POSITION)
3 3 5 5 TURNING GEAR ENGAGED SWITCH
6 6 8 18
4 4 6 6 (CONTACT OPEN WHEN ENGAGED)
7 7 9 19
5 5 7 7 ENGINE START MAGNET VALVE
8 8 10 20
6 6 8 8 (DC24V 0.23A) RATING 1MIN.
COPYRIGHT
9 9 11 21
7 7 9 9 ENGINE STOP MAGNET VALVE
10 10 12 22
B 8 8 10 10 B
11 11 13 23 (DC24V 0.38A) RATING CONT.
9 9 11 11
12 12 14 26 F. O . RACK LIMIT MAGNET VALVE
10 10 12 12
13 13 15 27 (DC24V 0.38A) RATING CONT.
11 11 13 13
14 14 16 41 F.O. LEAK TANK LEVEL SW. FOR ALARM
12 12 14 14
15 15 17 42 (O P E N A T H I G H LEVEL)
1 3 X 1mm² SCREEN 1 15 15
16 16 18 51 N O . 2 L. O . FILTER DIFF. PRESS. SW. FOR ALARM
2 (BY YARD) 2 16 16
17 17 19 52 (OPEN AT >= 1.2 Bar)
PORT M/E ALARM PANEL (WHP)
P O R T M / E A L A R M P A N E L (E C P )
25 22 22 B2 (OPEN AT >= 95 C)
26 23 23 91 L.O. ENG. INLET PRESS. TX.
27 24 24 92 (0~10BAR, 4~20mA, DC24V)
25 25
Schutzvermerk nach DIN34 beachten
28 45
26 26 F.W. ENG. OUTLET TEMP. SENSOR PT100
29 46
27 27 (0~100 C, PT100, DC24V)
30 47
1 2 X 1mm² SCREEN 1
31 97
2 (BY YARD) 2
32 98 TACHO METER (ENGINE FITTING)
D D
33 99
X1 34
1 35
2 36
37
38
39
X2
1
E E
2
3 E2
1 2 X 1mm² 1
4 1 S T A R T I N G AIR PRESS.SW. [*]
2 (BY YARD) 2
5 2 (OPEN AT < Bar)
1 2 X 1mm² 1
6 3 CONTROL AIR V/V SHUT [*]
2 (BY YARD) 2
NOTE: 4 ( O P E N A T S H U T POSITION)
[*] APPLY FOR PORT ENGINE ONLY
[**] ALL SPARE CABLE ARE TO BE
DETERMINE BY YARD
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
X4 X1 XP
1 2 X 1mm² 1 1 2 X 2.5mm² 24V DC SUPPLY INPUT
1 1 +
2 (BY YARD) 2 2 (BY YARD) (SHIPYARD 2A)
2 2 -
COPYRIGHT
X1
B 1 2 X 1mm² 1
LIGHT J/B
B
ROTATING
5 COMBI.FLASHER
SIREN &
2 (BY YARD) 2
6 HORN
X5 1F-X1
1 2 X 2.5mm² 1
C + + C
2 (BY YARD) 2 24V DC INPUT (SHIP SUPPLY)
- -
1 8 X 1mm² 1
P O R T M / E A L A R M P A N E L (E R P )
1 1 F P P CONTROL FAIL
2 (BY YARD) 2
2 2 ( O P E N A T A LARM)
REMOTE CONTROL
3 3 CLUTCH ENGAGE SIGNAL
3 3
4 4 (CLUTCH ENGAGE CONTACT OPEN)
4 4
Schutzvermerk nach DIN34 beachten
5 5
PANEL (MPC)
5 5 REMOTE CONTROL
6 6 (REMOTE CONTROL CONTACT CLOSE)
6 6
7 7
7 7 ENGINE TRIP
8 8
8 8 (CLOSE AT TRIP)
D D
X6
1 P O R T G E A R B O X J U N C T I O N B O X ( B Y YANMAR YXH2500)
2
1 2 X 1mm² 1
3 31 L.O. PRESS. SW. FOR ALARM
2 (BY YARD) 2
4 32 (OPEN AT =< 0.3 Bar)
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
X7 X1 X2
1 1 8 X 1mm² 1 1 (P) CONTROL TRANSFER SOLENOID +
2 (BY YARD) 2
2 2 (ENERGISE AT REMOTE SELECTION) -
3 3
3 3 1 FROM REMOTE CONTROL PANEL (MPC)
4 4 (P) GOVERNOR HOLD SOLENOID
4 4 2 REFER TO P2200B2016 FOR DETAILS
COPYRIGHT
5 5
5 5 (P) CONTROL AIR PRESS. SW. FOR GOVERNOR HOLD 3
B 6 6 B
6 6 (OPEN AT < 4.5 BAR)
7 7
7 7 (P ) C O N T R OL AIR PRESS. SW. FOR ALARM
8 8 (OPEN AT < 5.5 BAR)
8 8
X8
1 2 X 1mm² 1
1 E N G I N E L. O . P R I M I NG P/P STARTER PANEL (BY OTHERS)
P O R T M / E A L A R M P A N E L (E R P )
2 (BY YARD) 2
2 ENGINE RUN SIGNAL TO STOP L.O. PRIMING PUMP
C C
X9
SHIP MONITORING
2 (O P EN AT ENGINE RUNNING => 300RPM)
3 3
3 SAP SYSTEM FAULTY/ WIRE BREAK
Schutzvermerk nach DIN34 beachten
4 4
4 ( O P E N A T A LARM)
5 5
5 COMMON TRIP
6 6
6 ( O P E N A T A LARM)
7 7
7 COMMON FAULT
8 8
D 8 ( O P E N A T A LARM) D
KM131
1
MODBUS OUTPUT 2
(OPTIONAL)
3
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
X10
1
2
P O R T M / E A L A R M P A N E L (E R P )
COPYRIGHT
B B
CB1
1 2 X 2.5mm² 2 2 0 V A C P O W E R S U P P LY I N P U T
L
2 (BY YARD)
N (SHIPYARD 3A)
XP
E
C C
CB2
+ 1 2 X 4mm² 2 4 V D C S U P P L Y P O W E R I NPUT
2 (BY YARD) (SHIPYARD 20A)
-
Schutzvermerk nach DIN34 beachten
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
S T B D M / E J U N C T I O N B O X (B Y Y A N M A R )
X1 X3 E1
1 2 X 2.5mm² 1 1 2 X 1mm² SCREEN 1
+ + 1 04
2 (BY YARD) 2 2 (BY YARD) 2
DIN34
1 12 X 1mm² 1 3 3
4 4 6 13 HANDLE SWITCH
2 (BY YARD) 2 4 4
5 5 7 14 (C LOSE AT RUN POSITION)
3 3 5 5 TURNING GEAR ENGAGED SWITCH
6 6 8 18
4 4 6 6 (CONTACT OPEN WHEN ENGAGED)
7 7 9 19
5 5 7 7 ENGINE START MAGNET VALVE
8 8 10 20
6 6 8 8 (DC24V 0.23A) RATING 1MIN.
COPYRIGHT
9 9 11 21
7 7 9 9 ENGINE STOP MAGNET VALVE
10 10 12 22
B 8 8 10 10 B
11 11 13 23 (DC24V 0.38A) RATING CONT.
9 9 11 11
12 12 14 26 F. O . RACK LIMIT MAGNET VALVE
10 10 12 12
13 13 15 27 (DC24V 0.38A) RATING CONT.
11 11 13 13
14 14 16 41 F.O. LEAK TANK LEVEL SW. FOR ALARM
12 12 14 14
15 15 17 42 (O P E N A T H I G H LEVEL)
1 3 X 1mm² SCREEN 1 15 15
16 16 18 51 N O . 2 L. O . FILTER DIFF. PRESS. SW. FOR ALARM
2 (BY YARD) 2 16 16
17 17 19 52 (OPEN AT >= 1.2 Bar)
STBD M/E ALARM PANEL (WHS)
28 45
26 26 F.W. ENG. OUTLET TEMP. SENSOR PT100
29 46
27 27 (0~100 C, PT100, DC24V)
30 47
1 2 X 1mm² SCREEN 1
31 97
2 (BY YARD) 2
32 98 TACHO METER (ENGINE FITTING)
D D
33 99
X1 34
1 35
2 36
37
38
39
X2
1
E E
2
3 E2
4 1
5 2
6 3
4
NOTE:
[**] ALL SPARE CABLE ARE TO BE
DETERMINE BY YARD
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
X4 X1
1 1 2 X 1mm² 1 3
2 (BY YARD) 2
2 4
COPYRIGHT
LIGHT J/B
ROTATING
SIREN &
B B
X5 2F-X1
1 2 X 2.5mm² 1
C + + C
2 (BY YARD) 2 24V DC INPUT (SHIP SUPPLY)
- -
1 8 X 1mm² 1
S T B D M / E A L A R M P A N E L (E R S )
1 1 F P P CONTROL FAIL
2 (BY YARD) 2
2 2 ( O P E N A T A LARM)
REMOTE CONTROL
3 3 CLUTCH ENGAGE SIGNAL
3 3
4 4 (CLUTCH ENGAGE CONTACT OPEN)
4 4
Schutzvermerk nach DIN34 beachten
5 5
PANEL (MPC)
5 5 REMOTE CONTROL
6 6 (REMOTE CONTROL CONTACT CLOSE)
6 6
7 7
7 7 ENGINE TRIP
8 8
8 8 (CLOSE AT TRIP)
D D
X6
1 S T B D G E A R B O X J U N C T I O N B O X ( B Y Y A N M A R Y X H2500)
2
1 2 X 1mm² 1
3 31 L.O. PRESS. SW. FOR ALARM
2 (BY YARD) 2
4 32 (OPEN AT =< 0.3 Bar)
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
X7 X1 X2
1 1 8 X 1mm² 1 1 (S) CONTROL TRANSFER SOLENOID +
2 (BY YARD) 2
2 2 (ENERGISE AT REMOTE SELECTION) -
3 3
3 3 1 FROM REMOTE CONTROL PANEL (MPC)
4 4 (S) GOVERNOR HOLD SOLENOID
4 4 2 REFER TO P2200B2016 FOR DETAILS
COPYRIGHT
5 5
5 5 (S) CONTROL AIR PRESS. SW. FOR GOVERNOR HOLD 3
B 6 6 B
6 6 (OPEN AT < 4.5 BAR)
7 7
7 7 (S ) C O N T R OL AIR PRESS. SW. FOR ALARM
8 8 (OPEN AT < 5.5 BAR)
8 8
X8
1 2 X 1mm² 1
1 E N G I N E L. O . P R I M I NG P/P STARTER PANEL (BY OTHERS)
S T B D M / E A L A R M P A N E L (E R S )
2 (BY YARD) 2
2 ENGINE RUN SIGNAL TO STOP L.O. PRIMING PUMP
C C
X9
SHIP MONITORING
2 (O P EN AT ENGINE RUNNING => 300RPM)
3 3
3 SAP SYSTEM FAULTY/ WIRE BREAK
Schutzvermerk nach DIN34 beachten
4 4
4 ( O P E N A T A LARM)
5 5
5 COMMON TRIP
6 6
6 ( O P E N A T A LARM)
7 7
7 COMMON FAULT
8 8
D 8 ( O P E N A T A LARM) D
KM131
1
MODBUS OUTPUT 2
(OPTIONAL)
3
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A A
RESERVED
X10
1
2
S T B D M / E A L A R M P A N E L (E R S )
COPYRIGHT
B B
CB1
1 2 X 2.5mm² 2 2 0 V A C P O W E R S U P P LY I N P U T
L
2 (BY YARD)
N (SHIPYARD 3A)
XP
E
C C
CB2
+ 1 2 X 4mm² 2 4 V D C S U P P L Y P O W E R I NPUT
2 (BY YARD) (SHIPYARD 20A)
-
Schutzvermerk nach DIN34 beachten
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A
Material List A
RESERVED
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A
Material List A
RESERVED
C C
Schutzvermerk nach DIN34 beachten
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A
Material List A
RESERVED
D D
E E
F 1 As Built 01.11.2016 LingJing Date 05.08.2016 C ustomer: Website: Project: PLANT LOC F
Yanmar Asia (S) P/L www.norisautomation.com = +30
0 AFC 07.09.2016 LingJing Drawn LingJing Vietnam MOA M/E Alarm Panel
Email: Fishery Inspection Boat (WHP & WHS)
B Revised - For Approval 1 9 . 0 8 . 2 0 16 LingJing Appr. Alfred Ref. No.: singapore@norisautomation.com DRAWING NO. Page 3
Hull KN6000-02 Material List
Rev. Date Name Norm Noris Automation Far East P.L. 2x6EY26-YXH2500 P2200A16.M of 5 Pages
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A
Material List A
RESERVED
C C
Schutzvermerk nach DIN34 beachten
D D
E E
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DIN34
A
Material List A
RESERVED
D D
E E
1 2 3 4 5 6 7 8