You are on page 1of 2

ATTACHMENT - 3

Document No.********** Rev. B


Upheaval Buckling Calculation (24" DFO Pipeline, D.F = 0.72)
1 As per OTC Paper 6335 by A.C. Palmer, C.P.Ellinas, D.M. Richards and J.Guijt, 1990
2
3 Non Corroded pipe
4
5 Input Data Unit Conv.fact Unit
6 Pipe diameter, D = 0.610 m 39.37008 24 inch
7 Nominal pipe thk, t = 0.0095 m 39.37008 0.375 inch
Corrosion Allowance = 0 m
8 Design pressure, P = 720 PSI 703.0696 506210 Kg/m2
9 Steel density = 7850 Kg/m3
10 Soil density, Y = 1600 Kg/m3
11 Youngs modulas of steel, E = 207000 Mpa 101971.62 21108125609 kg/m2
12 Poisson ratio, n = 0.3
13 Thermal expansion, a = 0.0000117 Per oC
14 Installation (backfill) Temp, T1 = 13 o
C
15 Design Temp (U/G), T2 = 60 o
C
16 Pipeline Cover depth, H = 1 m
17 Fluid density (0.65 s.g) = 0 Kg/m3 (Consider zero for conservative reason)
18 Uplift coefficient = 0.1 (for loose soil or 0.5 for dense material)
19
20 Pipe Properties
21 Pipe cross sectional area, A = π/4(D2-d2) = 0.017956 m2
22 Pipe Section modulus, I = π/64(D4-d4) = 0.000808 m4
23 Pipe flexural rigidity = EI = 17064774 kg-m2
24 Weight of pipe = Sect area x L x density 140.9581 Kg/m
Pipe contents sectional area = π/4(D-2xt)2 = 0.273907 m2
Weight of contents = Sect area x L x density 0 Kg/m
25
26 Pipeline Axial force = (P) = A {0.5 Sh + Eα(T2-T1) - ٧Sh }
27 Axial stress due hoop stress = ٧(PD)/(2t) = 4859617 Kg/m2 (+)
28 Axial stress due to pressure = 0.5xSh = 8099362 Kg/m2 (-)
29 Thermal stress = Eα(T2-T1) = 11607358 Kg/m2 (-)
30 So the Axial force (P) = = 266601 kg
31
32 The required down force from OTC Paper
33
34 W = [1.16 – 4.76 (EI Wo / d)0.5 / P] P ( d Wo / EI) 0.5 Kg/m
35
36 The Uplift resistance from Soil & Pipe weight
37 Q = H x D x Ƴx [1+f x (H / D)]
38 Wo = Weight of Pipe + Contents
39
40
41 Condition for Stability = W < Wo + Q
42 Imperfection height Req. Down force (W) Uplift soil resistance(Q) Wo Q + Wo Stability
43 0.1 -389.89 1007.42 140.96 1148.38 Stable
44 0.2 -273.47 882.69 140.96 1023.65 Stable
45 0.3 -184.13 761.15 140.96 902.11 Stable
46 0.4 -108.82 642.82 140.96 783.77 Stable
47 0.5 -42.47 527.68 140.96 668.64 Stable
48
49
50
51
52
53
54
55
56
57

'file:///conversion/tmp/activity_task_scratch/539080445.xls'#$24" diesel nc

Page 1 of 2
ATTACHMENT - 3
Document No. ************ Rev. B
Upheaval Buckling Calculation (24" DFO Pipeline, D.F = 0.72)
1 As per OTC Paper 6335 by A.C. Palmer, C.P.Ellinas, D.M. Richards and J.Guijt, 1990
2
3 Corroded pipe
4
5 Input Data Unit Conv.fact Unit
6 Pipe diameter, D = 0.610 m 39.37008 24 inch
7 Nominal pipe thk, t = 0.0095 m 39.37008 0.375 inch
Corrosion Allowance = 0.001 m
8 Design pressure, P = 720 PSI 703.0696 506210 Kg/m2
9 Steel density = 7850 Kg/m3
10 Soil density, Y = 1600 Kg/m3
11 Youngs modulas of steel, E = 207000 Mpa 101971.62 21108125609 kg/m2
12 Poisson ratio, n = 0.3
13 Thermal expansion, a = 0.0000117 Per oC
14 Installation (backfill) Temp, T1 = 13 C
o

15 Design Temp (U/G), T2 = 60 C


o

16 Pipeline Cover depth, H = 1 m


17 Fluid density (0.65 s.g) = 0 Kg/m3 (Consider zero for conservative reason)
18 Uplift coefficient = 0.1 (for loose soil or 0.5 for dense material)
19
20 Pipe Properties
21 Pipe cross sectional area, A = π/4(D2-d2) = 0.016098 m2
22 Pipe Section modulus, I = π/64(D4-d4) = 0.000727 m4
23 Pipe flexural rigidity = EI = 15348901 kg-m2
24 Weight of pipe = Sect area x L x density 126.3696 Kg/m
Pipe contents sectional area = π/4(D-2xt)2 = 0.275765 m2
Weight of contents = Sect area x L x density 0 Kg/m
25
26 Pipeline Axial force = (P) = A {0.5 Sh + Eα(T2-T1) - ٧Sh }
27 Axial stress due hoop stress = ٧(PD)/(2t) = 4859617 Kg/m2 (+)
28 Axial stress due to pressure = 0.5xSh = 8099362 Kg/m2 (-)
29 Thermal stress = Eα(T2-T1) = 11607358 Kg/m2 (-)
30 So the Axial force (P) = = 239009 kg
31
32 The required down force from OTC Paper
33
34 W = [1.16 – 4.76 (EI Wo / d)0.5 / P] P ( d Wo / EI) 0.5 Kg/m
35
36 The Uplift resistance from Soil & Pipe weight
37 Q = H x D x Ƴx [1+f x (H / D)]
38 Wo = Weight of Pipe + Contents
39
40
41 Condition for Stability = W < Wo + Q
42 Imperfection height Req. Down force (W) Uplift soil resistance(Q) Wo Q + Wo Stability
43 0.1 -349.95 1007.42 126.37 1133.79 Stable
44 0.2 -245.75 882.69 126.37 1009.06 Stable
45 0.3 -165.79 761.15 126.37 887.52 Stable
46 0.4 -98.38 642.82 126.37 769.19 Stable
47 0.5 -39.00 527.68 126.37 654.05 Stable
48
49
50
51
52
53
54
55
56
57

'file:///conversion/tmp/activity_task_scratch/539080445.xls'#$24" diesel corr

Page 2 of 2