L900 ACTIVATION ON EXISTING FDD WITH RRH INSTALLATION AND BOARD ADDITION
MIN926 BUDAFL & MIN1492 GAIDIGOSODFL & MIN223 MAGCARF

MOP HISTORY
MOST RECENT REVISION DETAIL/S AUTHOR APPROVED BY DATE APPROVED
VERSION
1.0

1. DESCRIPTION
TO ACTIVATE L900 ON EXISTING FDD L1800 L700 WITH RRH INSTALLATION OF NEW NOKIA ARDA/AHDA AND
ADDITION OF NEW ABIA2

2. PURPOSE AND SCOPE


THE PURPOSE OF THIS ACTIVITY IS TO CO-LOCATE THE NEW L900 INTO EXISTING L1800 L700 AND THIS MOP
IS FOR SITES WITH NOKIA RADIOS

1. NEW RRH INSTALLATION AND ACTIVATION

2. BOARD ADDITION

3. SCF LOADING WITH L900 CONFIGURATION

3. BACKGROUND

PART OF THE 3G TO 4G MIGRATION IS TO REPLACE L1800 RRH WITH AHEGC WHICH IS THE DUAL BAND
L1800+L2100 RRH FOR THE MIGRATION OF U2100 TO L2100

WE WILL NEED ALSO TO INSTALL L900 RRH FOR THE MIGRATION OF U900 TO L900

4. PROPONENT
Name Position Dept./Div. Signature Date
FRANGELO ALILIN INTEGRATION
MINDANAO AGILE SQUAD
RAMON ROSALES COACH
MINDANAO AGILE SQUAD
Note: Required Signatories

Confidential. This document is not to be reproduced without the permission from Globe Telecom.
MOP Ref. #: _VERSION # :
(to be provided by DMSC) Why
METHOD OF PROCEDURE (MOP) from DMSC? DMSC provide process
number no the MOP number!
Page 2 of 10
L900 ACTIVATION ON EXISTING FDD WITH RRH INSTALLATION AND BOARD ADDITION
MIN926 BUDAFL & MIN1492 GAIDIGOSODFL & MIN223 MAGCARF
Minor – up to Section Head
Major – up to Department Head
Critical – up to Division Head

5. Target Date and Time of Implementation: 15 MAY 2021 (SATURDAY) 0800H-1800H

6. CHANGE CATEGORY

Minor Major Critical

7. TYPE OF SERVICES AFFECTED


Service : Product : MVNO /IR/Others :
4G LTE DATA & VOICE-LTE NOKIA FDD N/A

8. SITE AND E2E SYSTEM AFFECTED


Site (Location) System (E2E)
BUDAF GAIDIGOSODF MAGCARF LTE1800 FDD
BUDAL GAIDIGOSODL LTE700 FDD

9. E2E SYSTEMS BLOCK DIAGRAM

FOR BUDAFLY

Confidential. This document is not to be reproduced without the permission from Globe Telecom.
MOP Ref. #: _VERSION # :
(to be provided by DMSC) Why
METHOD OF PROCEDURE (MOP) from DMSC? DMSC provide process
number no the MOP number!
Page 3 of 10
L900 ACTIVATION ON EXISTING FDD WITH RRH INSTALLATION AND BOARD ADDITION
MIN926 BUDAFL & MIN1492 GAIDIGOSODFL & MIN223 MAGCARF

FOR GAIDIGOSODFLY

FOR MAGCARFY

Confidential. This document is not to be reproduced without the permission from Globe Telecom.
MOP Ref. #: _VERSION # :
(to be provided by DMSC) Why
METHOD OF PROCEDURE (MOP) from DMSC? DMSC provide process
number no the MOP number!
Page 4 of 10
L900 ACTIVATION ON EXISTING FDD WITH RRH INSTALLATION AND BOARD ADDITION
MIN926 BUDAFL & MIN1492 GAIDIGOSODFL & MIN223 MAGCARF

10.WITH OTHER RELATED ACTIVITY: YES NO


Description
SO REF#
MOP REF#
Other Network Element (NE) Affected
Remarks:

11.SPECIFIC NODE AFFECTED IN THIS MOP


HARDWARE
System Name Product Version Remarks
FDD ENODEB AIRSCALE
SOFTWARE
System Name Product Version Remarks
FDD ENODEB AIRSCALE SBTS20B

12.PEOPLE INVOLVED DURING IMPLEMENTATION OF THE ACTIVITY


Company Department Name Role Contact
Number
GLOBE TELECOM MINDANAO RGPM LING LING TOE ANG ICD 1ST APPROVER 0917 688 2044
GLOBE TELECOM SICE ACCESS TRANSPORT LOUIE DIMAILIG ICD 2ND APPROVER 0917 688 0737
NOKIA NOKIA ROC NOKIA ROC ALARM MONITORING 0917 503 8634
NOKIA NOKIA TM RICHARD DOLE TECHNICAL SUPPORT 0917 774 7071
NOKIA NOKIA TM JAYSON SALANG TECHNICAL SUPPORT 0956 800 0778
NOKIA NOKIA NI ARCHIE UY AREA MANAGER 0917 887 9730
NOKIA NOKIA NI LEMUEL ACEBEDO SITE ENGINEER 0917 655 7766
NOKIA NOKIA NI GILBERT MERCADO AREA MANAGER 0917 301 0514
NOKIA NOKIA NI PJ ZAMORA SITE ENGINEER 0977 814 6986
GLOBE TELECOM NOC SCC_WIRELESS 0917 354 2161

13.SUPPORTING DOCUMENTS
Reference Number Description

LTE BFT Procedure


BASIC
FUNCTIONALITY TEST MOP FINAL.docx

Confidential. This document is not to be reproduced without the permission from Globe Telecom.
MOP Ref. #: _VERSION # :
(to be provided by DMSC) Why
METHOD OF PROCEDURE (MOP) from DMSC? DMSC provide process
number no the MOP number!
Page 5 of 10
L900 ACTIVATION ON EXISTING FDD WITH RRH INSTALLATION AND BOARD ADDITION
MIN926 BUDAFL & MIN1492 GAIDIGOSODFL & MIN223 MAGCARF

14.WORK BREAKDOWN SCHEDULE


Start Time End Time Activity Responsible Remarks
0800H 0900H PRE BFT L1800 L700 FOR BUDAFL GAIDIGOSODFL NOKIA ICM no impact
PRE BFT L1800 FOR MAGCARF SITE ENGINEER

RF DIAGNOSTIC TEST IN BTS MANAGER/WEB


ELEMENT (WEBEM)

BACKUP COMMISSIONING FILES AND FULL


SNAPSHOTS
0900H 1100H LOCK L1800 L700 FOR BUDAFL GAIDIGOSODFL SITE ENGINEER outage
LOCK L1800 FOR MAGCARF L1800 L700

INSERT ABIA2

UNPLUG TRANSPORT CABLE AND SFP MODULE

CONFIG RESET
● CPRI RECABLING OF EXISTING L1800 RRH
NOKIA 1xFXED FROM EXISTING ABIA1
PORTS 3,4 TO NEW ABIA2 PORTS 1,2
THEN CPRI INSERTION OF NEW L900 RRH
NOKIA 1xARDA AT EXISTING ABIA1 PORTS
3,4 WITH RE-USE CPRI CABLING OF
EXISTING L700 RRH NOKIA 1xFRPA AT
EXISTING ABIA1 PORTS 1,2 (BUDAFLY)
● CPRI RECABLING OF EXISTING L1800 RRH
NOKIA 2xFXED FROM EXISTING ABIA1
PORTS 3,4 TO NEW ABIA2 PORTS 1,2
THEN CPRI INSERTION OF NEW L900 RRH
NOKIA 3xAHDA AT EXISTING ABIA1
PORTS 3,4,5 WITH RE-USE CPRI CABLING
OF EXISTING L700 RRH NOKIA 2xFRPA AT
EXISTING ABIA1 PORTS 1,2
(GAIDIGOSODFLY)
● CPRI RECABLING OF EXISTING L1800 RRH
NOKIA 1xFXED FROM EXISTING ABIA1
PORTS 1,2 TO NEW ABIA2 PORTS 1,2
THEN CPRI INSERTION OF NEW L900 RRH
NOKIA 1xARDA AT EXISTING ABIA1 PORT
1 (MAGCARFY)

Confidential. This document is not to be reproduced without the permission from Globe Telecom.
MOP Ref. #: _VERSION # :
(to be provided by DMSC) Why
METHOD OF PROCEDURE (MOP) from DMSC? DMSC provide process
number no the MOP number!
Page 6 of 10
L900 ACTIVATION ON EXISTING FDD WITH RRH INSTALLATION AND BOARD ADDITION
MIN926 BUDAFL & MIN1492 GAIDIGOSODFL & MIN223 MAGCARF

DETECTION OF NEW L900 RRH

SOFTWARE UPDATE/UPGRADE FOR NEW RRH

LOAD SCF WITH NEW RRH (DATABASE WILL


INCLUDE L1800+L700+L900)

PLUG TRANSPORT CABLE AND SFP MODULE

UNLOCK L1800 L700 L900 end of outage


1100H 1300H POST BFT OF L1800 L700 L900 NOKIA ICM no impact
SITE ENGINEER
ALARM CHECK

RF DIAGNOSTIC TEST IN BTS MANAGER/WEB


ELEMENT (WEBEM)

BACKUP COMMISSIONING FILES AND FULL


SNAPSHOTS
1300H 1500H REVERT IN CASE OF ISSUES NOKIA ICM outage
SITE ENGINEER L1800 L700
LOCK L1800 L700 L900 L900

UNPLUG TRANSPORT CABLE AND SFP MODULE

CONFIG RESET
● REMOVE CPRI INSERTION OF L900 RRH
NOKIA ARDA FROM ABIA1 PORTS 3,4
THEN CPRI RECABLING OF L1800 RRH
NOKIA FXED FROM ABIA2 PORTS 1,2 TO
ABIA1 PORTS 3,4 (BUDAFL)
● REMOVE CPRI INSERTION OF L900 RRH
NOKIA AHDA FROM ABIA1 PORTS 3,4,5
THEN CPRI RECABLING OF L1800 RRH
NOKIA FXED FROM ABIA2 PORTS 1,2 TO
ABIA1 PORTS 3,4 (GAIDIGOSODFL)
● REMOVE CPRI INSERTION OF L900 RRH
NOKIA ARDA FROM ABIA1 PORT 1 THEN
CPRI RECABLING OF L1800 RRH NOKIA
FXED FROM ABIA2 PORTS 1,2 TO ABIA1
PORTS 1,2 (MAGCARF)

Confidential. This document is not to be reproduced without the permission from Globe Telecom.
MOP Ref. #: _VERSION # :
(to be provided by DMSC) Why
METHOD OF PROCEDURE (MOP) from DMSC? DMSC provide process
number no the MOP number!
Page 7 of 10
L900 ACTIVATION ON EXISTING FDD WITH RRH INSTALLATION AND BOARD ADDITION
MIN926 BUDAFL & MIN1492 GAIDIGOSODFL & MIN223 MAGCARF

REMOVE ABIA2

LOAD SCF WITH THE ORIGINAL TYPE OF RRH

PLUG TRANSPORT CABLE AND SFP MODULE

UNLOCK L1800 L700 end of outage

15.KNOWN ISSUES, RISKS AND MITIGATIONS (Preventive)

● DEFECTIVE ABIA BOARD AND DEFECTIVE CPRI CABLES


● INCORRECT SFP MODULE

16.PRE-REQUISITES PRIOR IMPLEMENTATION

● APPROVED RAAWA (SITE ACCESS PERMIT) FOR ON-SITE IMPLEMENTATION TEAM


● APPROVED S.O. CRF# CREATED IN ICD
● RESOURCES (NOKIA ICM + BFT SITE ENGINEER)
● SCF CONTAINING THE NEW RRH
● NOKIA AHDA/ARDA ALREADY INSTALLED
● SITE IS ALREADY IN SBTS20B SOFTWARE RELEASE

17.SUCCESS, ABORT AND REVERT BACK CRITERIA

SUCCESS CRITERIA
● CHECKING THE OPERATING STATUS OF THE ENODEB (NO NEW ALARM IS REPORTED AND NO BOARD
WITH UNEXPECTEDLY RESET)
● POST BFT PASSED
● CHECKING OF CELL STATUS (ALL THE CONFIGURED CELLS ARE AVAILABLE)
● PRE KPI AND POST KPI WITH NO MAJOR KPI DEGRADATIONS ARE OBSERVED (RRC CONNECTION SUCCESS
RATE, ERAB SETUP SUCCESS RATE, CALL DROP RATE, LTE USER NUMBER, TRAFFIC VOLUME, AVERAGE TP,
CSFB SUCCESS RATE)
● OPTIMIZATION 0.5% TO 5% DEGRADATIONS OF MAJOR KPI (DISCUSSION/REVERT)

ABORT CRITERIA
● ALARMS OBSERVED DURING IMPLEMENTATION
● ENCOUNTERED SEVERAL ERRORS IN THE SCRIPT DURING IMPLEMENTATION
● CRITICAL ALARMS OBSERVED

Confidential. This document is not to be reproduced without the permission from Globe Telecom.
MOP Ref. #: _VERSION # :
(to be provided by DMSC) Why
METHOD OF PROCEDURE (MOP) from DMSC? DMSC provide process
number no the MOP number!
Page 8 of 10
L900 ACTIVATION ON EXISTING FDD WITH RRH INSTALLATION AND BOARD ADDITION
MIN926 BUDAFL & MIN1492 GAIDIGOSODFL & MIN223 MAGCARF

REVERT CRITERIA
● >5% DEGRADATIONS OF MAJOR KPI
● POST KPI DATA NOT NORMAL
● SITE WITH ALARMS
● POST BFT FAILED

18.PRE-ACTIVITY PROCEDURES

● PRE BFT L1800 L700 FOR BUDAFL GAIDIGOSODFL


● PRE BFT L1800 FOR MAGCARF
● RF DIAGNOSTIC TEST IN BTS MANAGER/WEB ELEMENT (WEBEM)
● BACKUP COMMISSIONING FILES AND FULL SNAPSHOTS

19.PLANNED ACTIVITY PROCEDURES

● LOCK L1800 L700 FOR BUDAFL GAIDIGOSODFL


● LOCK L1800 FOR MAGCARF
● INSERT ABIA2
● UNPLUG TRANSPORT CABLE AND SFP MODULE
● CONFIG RESET
● CPRI RECABLING OF EXISTING L1800 RRH NOKIA 1xFXED FROM EXISTING ABIA1 PORTS 3,4 TO NEW
ABIA2 PORTS 1,2 (BUDAFLY)
● CPRI INSERTION OF NEW L900 RRH NOKIA 1xARDA AT EXISTING ABIA1 PORTS 3,4 (BUDAFLY)
● RE-USE CPRI CABLING OF EXISTING L700 RRH NOKIA 1xFRPA AT EXISTING ABIA1 PORTS 1,2 (BUDAFLY)
● CPRI RECABLING OF EXISTING L1800 RRH NOKIA 2xFXED FROM EXISTING ABIA1 PORTS 3,4 TO NEW
ABIA2 PORTS 1,2 (GAIDIGOSODFLY)
● CPRI INSERTION OF NEW L900 RRH NOKIA 3xAHDA AT EXISTING ABIA1 PORTS 3,4,5 (GAIDIGOSODFLY)
● RE-USE CPRI CABLING OF EXISTING L700 RRH NOKIA 2xFRPA AT EXISTING ABIA1 PORTS 1,2
(GAIDIGOSODFLY)
● CPRI RECABLING OF EXISTING L1800 RRH NOKIA 1xFXED FROM EXISTING ABIA1 PORTS 1,2 TO NEW
ABIA2 PORTS 1,2 (MAGCARFY)
● CPRI INSERTION OF NEW L900 RRH NOKIA 1xARDA AT EXISTING ABIA1 PORT 1 (MAGCARFY)
● DETECTION OF NEW L900 RRH
● SOFTWARE UPDATE/UPGRADE FOR NEW RRH
● LOAD SCF WITH NEW RRH (DATABASE WILL INCLUDE L1800+L700+L900)
● PLUG TRANSPORT CABLE AND SFP MODULE
● UNLOCK L1800 L700 L900

Confidential. This document is not to be reproduced without the permission from Globe Telecom.
MOP Ref. #: _VERSION # :
(to be provided by DMSC) Why
METHOD OF PROCEDURE (MOP) from DMSC? DMSC provide process
number no the MOP number!
Page 9 of 10
L900 ACTIVATION ON EXISTING FDD WITH RRH INSTALLATION AND BOARD ADDITION
MIN926 BUDAFL & MIN1492 GAIDIGOSODFL & MIN223 MAGCARF

20.POST ACTIVITY CHECKING AND VALIDATION

● POST BFT OF L1800 L700 L900


● ALARM CHECK
● RF DIAGNOSTIC TEST IN BTS MANAGER / WEB ELEMENT (WEBEM)
● BACKUP COMMISSIONING FILES AND FULL SNAPSHOTS

21.REVERT BACK PROCEDURES

● LOCK L1800 L700 L900


● UNPLUG TRANSPORT CABLE AND SFP MODULE
● CONFIG RESET
● REMOVE CPRI INSERTION OF L900 RRH NOKIA ARDA FROM ABIA1 PORTS 3,4 (BUDAFL)
● CPRI RECABLING OF L1800 RRH NOKIA FXED FROM ABIA2 PORTS 1,2 TO ABIA1 PORTS 3,4 (BUDAFL)
● REMOVE CPRI INSERTION OF L900 RRH NOKIA AHDA FROM ABIA1 PORTS 3,4,5 (GAIDIGOSODFL)
● CPRI RECABLING OF L1800 RRH NOKIA FXED FROM ABIA2 PORTS 1,2 TO ABIA1 PORTS 3,4
(GAIDIGOSODFL)
● REMOVE CPRI INSERTION OF L900 RRH NOKIA ARDA FROM ABIA1 PORT 1 (MAGCARF)
● CPRI RECABLING OF L1800 RRH NOKIA FXED FROM ABIA2 PORTS 1,2 TO ABIA1 PORTS 1,2 (MAGCARF)
● REMOVE ABIA2
● LOAD SCF WITH THE ORIGINAL TYPE OF RRH
● PLUG TRANSPORT CABLE AND SFP MODULE
● UNLOCK L1800 L700

22.POST REVERT BACK SUCCESS CRITERIA

● NO UNEXPLAINABLE LARMS APPEARED AFTER REVERSION


● POST REVERT BFT IS SUCCESSFUL
● POST KPI DATA HAS NO DEGRADATIONS

23.CONTINGENCY (If Revert Procedure Fails)

● IN CASE THE SITE HANGED UP AFTER THE ACTIVITY ALU/NSB MAINTENANCE WILL DO ON-SITE RESET
● IN CASE THE ENODEB HAS REACHABILITY PROBLEM FROM SAM ALU/NSB MAINTENANCE WILL DO ON-
SITE RESET

Confidential. This document is not to be reproduced without the permission from Globe Telecom.
MOP Ref. #: _VERSION # :
(to be provided by DMSC) Why
METHOD OF PROCEDURE (MOP) from DMSC? DMSC provide process
number no the MOP number!
Page 10 of 10
L900 ACTIVATION ON EXISTING FDD WITH RRH INSTALLATION AND BOARD ADDITION
MIN926 BUDAFL & MIN1492 GAIDIGOSODFL & MIN223 MAGCARF

24.MOP REVISION DETAILS (to be filled in by SEI reviewing engr)


REVISION 1 : (indicate reason)

Lack of Mandatory Information Condfiguration not aligned with standard / LLD


Confusing instruction in the procedure Missing Configuration
Missing step in procedure Wrong Configuration
Typing Error Incorrect Data

REVISION 2 : (indicate reason based on same list above)

REVISION 3 : (indicate reason based on same list above)

Confidential. This document is not to be reproduced without the permission from Globe Telecom.

You might also like