0331/32 / 33/34/35/36
GENERAL NOTE
HMD DWG . NO = 1A000E002
2 . RULE AND REGULATION = LR . +IOOA1 . DOUBLE HULL OIL AND CHEMICAL TANKER ESP.
SHIP TYPE 3 IN ASSOCIATION KITH A LIST OF DEFINED
CARGOES . *LMC . UMS . LI . IGS.
SHIPRIGHT (SDA . FDA . CM)
3. THE PREFERENTIAL TRIPPING BREAKERS ARE SO INSTALLED AS TO BE TRIPPED BY OVER CURRENT
RELAYS FOR THE MAIN GENERATOR ~~E~ THE OPERATING GER~n~oRCS) IS [ARE7 OVER LOADED.
4. EM'CY TRIPPING BREAKERS ARE SO INSTALLED AS TO BE TRIPPED BY EM'CY STOP 1N THE EVENT OF FIRE
THE EM'CY STOP SNITCH $ ARE TO BE LOCATED OUTSIDE OF ENGINE ROOM.
(E/R ENTRANCE . ~/H CONSOLE . FIRE CONTROL STATION)
6. THE OVERLOAD TRIP SETTING OF THE FEEDER CIRCUIT BREAKER FOR STEERING GEAR IS
TO BE 200% OF THE STARTING CURRENT OF THE MOTOR AND TO ALLOW ExCESS CURRENT TO PASS DURING
THE NORMAL ACCELERATING OF THE MOTORS
7. THE AIR CIRCUIT BREAKERS OF GENERATORS ARE SO INTERLOCKED AS NOT TO OPERATE IN PARALLEL
KITH SHORE SUPPLY.
8. THE CABLES HAVING NOMINAL OUTDIAMETER 30 . . AND ABOVE ARE NOT TO BE BUNCHED OR LAID
TOGETHER 1N FLAT FORMATION MORE THAN SIX (6l CABLE.
9 . AS FOR THE DETAILS ON THE RELATIVE CIRCUITS . SEE THE FOLLOWING DRA~INCS RESPECTIVELY.
DSC N0 . DESCRIPTION
1A000E009 ~/D OF CONTROL 6 INSTRUMETATION SYSTEM
1A000E006 ~/D OF COMMUNICATION ~ NAVIGATION SYSTEM
1A000E008 ~/D OF AND ARR'T OF FIRE DETECTION b GEN . ALARM SYSTEM
1A000E003 ~/D OF LIGHTING SYSTEM EXCEPT E/ROOM
1A200E001 W/D OF LIGHTING SYSTEM IN S/GEAR ROOM ~ E/ROOM
= 1XTURE
N
O
O
w
O P = POSER DIAGRAM
O
0а L = LIGHTING DIAGRAM
A = CONTROL/MONITOR DIAGRAM
1
n
~ _ ~nvt . ~ co~~ . OIACRA~
N
0
W
1 = INTER - COMM . DIAGRAM
F = FIRE DECT ./ GEN . ALARM DIAGRAM