Delta Air Lines Aircraft Maintenance Manual (AMM)

Printed: 8/29/2018; 09:33am.


Rev. 22 Aug-23-2018

TASK A350-A-24-71-57-00001-921A-A

RCCB - EPDC (Electrical Power Distribution Center) - Swapping of the RCCB

ON A/C ALL

References
Table 1 References

Data Module/Technical Publication Title

ON A/C ALL

MP - De-energize the Aircraft Electrical Circuits from External


A350-A-24-41-XX-00ZZZ-561Z-A
Power Receptacle 1

ON A/C ALL
MP - Energize the Aircraft Electrical Circuits from External Power
A350-A-24-41-XX-00ZZZ-761Z-A
Receptacle 1

ON A/C ALL

MP - Removal of the ATA24 Remote Control Circuit Breaker (RCCB)


A350-A-24-71-57-00ZZZ-520Z-A
from Electrical Power Distribution Center 1 (EPDC1)
ON A/C ALL
MP - Removal of the ATA21 Remote Control Circuit Breaker (RCCB)
A350-A-24-71-57-01ZZZ-520Z-A
from Electrical Power Distribution Center 1 (EPDC1)

ON A/C ALL
MP - Removal of the ATA27 Remote Control Circuit Breaker (RCCB)
A350-A-24-71-57-02ZZZ-520Z-A
from Electrical Power Distribution Center 1 (EPDC1)
ON A/C ALL

MP - Removal of the ATA28 Remote Control Circuit Breaker (RCCB)


A350-A-24-71-57-03ZZZ-520Z-A
from Electrical Power Distribution Center 1 (EPDC1)
ON A/C ALL

MP - Removal of the ATA29 Remote Control Circuit Breaker (RCCB)


A350-A-24-71-57-04ZZZ-520Z-A
from Electrical Power Distribution Center 1 (EPDC1)

ON A/C ALL
MP - Removal of the ATA30 Remote Control Circuit Breaker (RCCB)
A350-A-24-71-57-05ZZZ-520Z-A
from Electrical Power Distribution Center 1 (EPDC1)

ON A/C ALL
MP - Removal of the ATA38 Remote Control Circuit Breaker (RCCB)
A350-A-24-71-57-06ZZZ-520Z-A
from Electrical Power Distribution Center 1 (EPDC1)

ON A/C ALL

MP - Removal of the ATA49 Remote Control Circuit Breaker (RCCB)


A350-A-24-71-57-07ZZZ-520Z-A
from Electrical Power Distribution Center 1 (EPDC1)
ON A/C ALL

MP - Removal of the ATA78 Remote Control Circuit Breaker (RCCB)


A350-A-24-71-57-08ZZZ-520Z-A
from Electrical Power Distribution Center 1 (EPDC1)

ON A/C ALL
MP - Removal of the ATA24 Remote Control Circuit Breaker (RCCB)
A350-A-24-71-57-09ZZZ-520Z-A
from Electrical Power Distribution Center 2 (EPDC2)

Filtering is on: 3510 A350-A-24-71-57-00001-921A-A Page 1 of 10


Delta Air Lines Aircraft Maintenance Manual (AMM)
Printed: 8/29/2018; 09:33am.
Rev. 22 Aug-23-2018

ON A/C ALL
MP - Removal of the ATA21 Remote Control Circuit Breaker (RCCB)
A350-A-24-71-57-0AZZZ-520Z-A
from Electrical Power Distribution Center 2 (EPDC2)

ON A/C ALL

MP - Removal of the ATA27 Remote Control Circuit Breaker (RCCB)


A350-A-24-71-57-0BZZZ-520Z-A
from Electrical Power Distribution Center 2 (EPDC2)
ON A/C ALL
MP - Removal of the ATA28 Remote Control Circuit Breaker (RCCB)
A350-A-24-71-57-0CZZZ-520Z-A
from Electrical Power Distribution Center 2 (EPDC2)

ON A/C ALL

MP - Removal of the ATA29 Remote Control Circuit Breaker (RCCB)


A350-A-24-71-57-0DZZZ-520Z-A
from Electrical Power Distribution Center 2 (EPDC2)
ON A/C ALL

MP - Removal of the ATA30 Remote Control Circuit Breaker (RCCB)


A350-A-24-71-57-0EZZZ-520Z-A
from Electrical Power Distribution Center 2 (EPDC2)
ON A/C ALL
MP - Removal of the ATA38 Remote Control Circuit Breaker (RCCB)
A350-A-24-71-57-0FZZZ-520Z-A
from Electrical Power Distribution Center 2 (EPDC2)
ON A/C ALL

MP - Removal of the ATA78 Remote Control Circuit Breaker (RCCB)


A350-A-24-71-57-0GZZZ-520Z-A
from Electrical Power Distribution Center 2 (EPDC2)
ON A/C ALL
MP - Removal of the ATA25 Remote Control Circuit Breaker (RCCB)
A350-A-24-71-57-0HZZZ-520Z-A
from Electrical Power Distribution Center 1 (EPDC1)

ON A/C ALL and (FOR FIN 1091-MC or RCCB-GALLEY FEEDER 9 AC)


MP - Installation of the ATA24 Remote Control Circuit Breaker
A350-A-24-71-57-00ZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 1 (EPDC1)
ON A/C ALL

MP - Installation of the ATA21 Remote Control Circuit Breaker


A350-A-24-71-57-01ZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 1 (EPDC1)
ON A/C ALL

MP - Installation of the ATA27 Remote Control Circuit Breaker


A350-A-24-71-57-02ZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 1 (EPDC1)

ON A/C ALL and (FOR FIN 1001-QA or RCCB-PUMP STBY 1 SPLY or FOR FIN 2001-QA or RCCB-PUMP MAIN 2 SPLY)
MP - Installation of the ATA28 Remote Control Circuit Breaker
A350-A-24-71-57-03ZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 1 (EPDC1)

ON A/C ALL and (FOR FIN 1001-JV or RCCB-G ELEC PUMP)

MP - Installation of the ATA29 Remote Control Circuit Breaker


A350-A-24-71-57-04ZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 1 (EPDC1)
ON A/C ALL

MP - Installation of the ATA30 Remote Control Circuit Breaker


A350-A-24-71-57-05ZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 1 (EPDC1)

ON A/C ALL

MP - Installation of the ATA38 Remote Control Circuit Breaker

Filtering is on: 3510 A350-A-24-71-57-00001-921A-A Page 2 of 10


Delta Air Lines Aircraft Maintenance Manual (AMM)
Printed: 8/29/2018; 09:33am.
Rev. 22 Aug-23-2018

A350-A-24-71-57-06ZZZ-720Z-A (RCCB) in Electrical Power Distribution Center 1 (EPDC1)


ON A/C ALL and (FOR FIN 1001-KA or RCCB-APU START AC)
MP - Installation of the ATA49 Remote Control Circuit Breaker
A350-A-24-71-57-07ZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 1 (EPDC1)

ON A/C ALL

MP - Installation of the ATA78 Remote Control Circuit Breaker


A350-A-24-71-57-08ZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 1 (EPDC1)
ON A/C ALL and (FOR FIN 1102-MC or RCCB-GALLEY FEEDER 10 AC)

MP - Installation of the ATA24 Remote Control Circuit Breaker


A350-A-24-71-57-09ZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 2 (EPDC2)

ON A/C ALL
MP - Installation of the ATA21 Remote Control Circuit Breaker
A350-A-24-71-57-0AZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 2 (EPDC2)
ON A/C ALL and (FOR FIN 2008-CV or RCCB-ADGB MCE EMOT PWR)
MP - Installation of the ATA27 Remote Control Circuit Breaker
A350-A-24-71-57-0BZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 2 (EPDC2)
ON A/C ALL and (FOR FIN 1000-QA or RCCB-PUMP STBY 2 SPLY or FOR FIN 2000-QA or RCCB-PUMP MAIN 1 SPLY)
MP - Installation of the ATA28 Remote Control Circuit Breaker
A350-A-24-71-57-0CZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 2 (EPDC2)
ON A/C ALL

MP - Installation of the ATA29 Remote Control Circuit Breaker


A350-A-24-71-57-0DZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 2 (EPDC2)
ON A/C ALL
MP - Installation of the ATA30 Remote Control Circuit Breaker
A350-A-24-71-57-0EZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 2 (EPDC2)
ON A/C ALL
MP - Installation of the ATA38 Remote Control Circuit Breaker
A350-A-24-71-57-0FZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 2 (EPDC2)
ON A/C ALL
MP - Installation of the ATA78 Remote Control Circuit Breaker
A350-A-24-71-57-0GZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 2 (EPDC2)
ON A/C ALL

MP - Installation of the ATA25 Remote Control Circuit Breaker


A350-A-24-71-57-0HZZZ-720Z-A
(RCCB) in Electrical Power Distribution Center 1 (EPDC1)

ON A/C ALL

1. General

A. Reason for the Job


Self Explanatory

B. Additional information
This procedure gives the instructions necessary to swap (interchange) the RCCB when RCCB is defective.

Swap the RCCBs only if:


– The Fault Isolation procedure confirms that RCCB is defective, and
– There is no spare RCCB available, and

Filtering is on: 3510 A350-A-24-71-57-00001-921A-A Page 3 of 10


Delta Air Lines Aircraft Maintenance Manual (AMM)
Printed: 8/29/2018; 09:33am.
Rev. 22 Aug-23-2018

– The aircraft is in a NO GO configuration (MEL), and


– This is in accordance with the airline policy.

NOGO RCCB: RCCB LRM with at least one RCCB failed leading to a NO_DISPATCH condition according to MEL.

GO or GOIF RCCB: RCCB LRM which allows the dispatch even in case of failure (with or without condition described in MEL).

2. Job Set-Up Information

A. Required Conditions

Table 2 Required Conditions

Title/Condition Data Module/Technical Publication

None

B. Support Equipment

Table 3 Support Equipment

Name Identification/Reference Quantity Remarks

ON A/C ALL

WARNING NOTICE(S) No Specific As required

C. Consumables, Materials and Expendables

Table 4 Consumables, Materials and Expendables

Name Identification/Reference Quantity Remarks

None

D. Spares

Table 5 Spares

Name Identification/Reference Quantity Remarks

None

E. Safety Conditions

Table 6 Safety Conditions

Name Safety Requirement

None

3. Job Set-Up

ON A/C ALL
SUBTASK 247157-10102630001

A. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits


Ref. MP A350-A-24-41-XX-00ZZZ-761Z-A.

4. Procedure

ON A/C ALL
SUBTASK 247157-40100660001

A. Preparation for RCCB swapping

(1) On the ECAM display, on the SD, on the “DISPATCH” page:

(a) Record the messages shown on ECAM display.


NOTE: The messages recorded will be used after swapping to define if NO GO configuration is solved.

(2) De-energize the aircraft electrical circuits

Filtering is on: 3510 A350-A-24-71-57-00001-921A-A Page 4 of 10


Delta Air Lines Aircraft Maintenance Manual (AMM)
Printed: 8/29/2018; 09:33am.
Rev. 22 Aug-23-2018

Ref. MP A350-A-24-41-XX-00ZZZ-561Z-A.

ON A/C ALL
SUBTASK 247157-40100750001

B. Structure of the Procedure


(1) This procedure is split in three parts. Each part contains instructions related to specific RCCB part number:

– For Part Number 106CZ02L05Yxx, go to Ref. 4.C..


– For Part Number 107CZ02L05Yxx, go to Ref. 4.D..

– For Part Number 115CZ02Yxx, go to Ref. 4.E..

ON A/C ALL

SUBTASK 247157-40100670001

C. Swapping of the RCCB Part Number 106CZ02L05Yxx


NOTE: The RCCBs which have the same P/N root must replace the NO GO RCCBs.

NOTE: It is possible that RCCBs of the same P/N root are not interchangeable. It is necessary to refer to the applicable IPD task to

know if you can interchange two RCCBs.


(1) Remove the defective RCCB (NO GO):

(a) From EPDC1:


1) For RCCB ATA 24 Ref. MP A350-A-24-71-57-00ZZZ-520Z-A.

2) For RCCB ATA 21 Ref. MP A350-A-24-71-57-01ZZZ-520Z-A.


3) For RCCB ATA 27 Ref. MP A350-A-24-71-57-02ZZZ-520Z-A.

4) For RCCB ATA 28 Ref. MP A350-A-24-71-57-03ZZZ-520Z-A.

5) For RCCB ATA 29 Ref. MP A350-A-24-71-57-04ZZZ-520Z-A.


6) For RCCB ATA 30 Ref. MP A350-A-24-71-57-05ZZZ-520Z-A.

7) For RCCB ATA 38 Ref. MP A350-A-24-71-57-06ZZZ-520Z-A.


8) For RCCB ATA 49 Ref. MP A350-A-24-71-57-07ZZZ-520Z-A.

9) For RCCB ATA 78 Ref. MP A350-A-24-71-57-08ZZZ-520Z-A.

10) For RCCB ATA 25 Ref. MP A350-A-24-71-57-0HZZZ-520Z-A.


(b) From EPDC2:
1) For RCCB ATA 24 Ref. MP A350-A-24-71-57-09ZZZ-520Z-A.

2) For RCCB ATA 21 Ref. MP A350-A-24-71-57-0AZZZ-520Z-A.


3) For RCCB ATA 27 Ref. MP A350-A-24-71-57-0BZZZ-520Z-A.

4) For RCCB ATA 28 Ref. MP A350-A-24-71-57-0CZZZ-520Z-A.

5) For RCCB ATA 29 Ref. MP A350-A-24-71-57-0DZZZ-520Z-A.

6) For RCCB ATA 30 Ref. MP A350-A-24-71-57-0EZZZ-520Z-A.

7) For RCCB ATA 38 Ref. MP A350-A-24-71-57-0FZZZ-520Z-A.


8) For RCCB ATA 78 Ref. MP A350-A-24-71-57-0GZZZ-520Z-A.

(2) Remove the RCCB which will be used to solve NO GO Configuration on RCCB:

(a) For EPDC1:

NOTE: P1 is related to the first RCCB that must be used for the replacement.
Table 7

Priority Designation FIN position Procedure

P1 RCCB-GALLEY FEEDER 4387XZ Ref. MP A350-A-24-71-57-00ZZZ-520Z-A

9 AC (1091MC)

Filtering is on: 3510 A350-A-24-71-57-00001-921A-A Page 5 of 10


Delta Air Lines Aircraft Maintenance Manual (AMM)
Printed: 8/29/2018; 09:33am.
Rev. 22 Aug-23-2018

P2 RCCB-G ELEC PUMP 4315XZ Ref. MP A350-A-24-71-57-04ZZZ-520Z-A


(1001JV)

P3 RCCB-GALLEY FEEDER 4358XZ Ref. MP A350-A-24-71-57-09ZZZ-520Z-A

10 AC (1102MC)

(b) For EPDC2:


NOTE: P1 is related to the first RCCB that must be used for the replacement.

Table 8

Priority Designation FIN position Procedure

P1 RCCB-GALLEY FEEDER 4358XZ Ref. MP A350-A-24-71-57-09ZZZ-520Z-A


10 AC (1102MC)

P2 RCCB-GALLEY FEEDER 4387XZ Ref. MP A350-A-24-71-57-00ZZZ-520Z-A

9 AC (1091MC)

P3 RCCB-G ELEC PUMP 4315XZ Ref. MP A350-A-24-71-57-04ZZZ-520Z-A


(1001JV)

(3) Install the defective RCCB on position of the replacement RCCB (P1, P2 or P3):

FOR FIN 1091-MC or RCCB-GALLEY FEEDER 9 AC


(a) Install defective RCCB on position of AC galley-feeder 9 RCCB (1091MC) Ref. MP A350-A-24-71-57-00ZZZ-720Z-A.

NOTE: It is not necessary to do the test requested in the installation procedure.

FOR FIN 1001-JV or RCCB-G ELEC PUMP

(b) Install defective RCCB on position of green electrical-pump RCCB (1001JV) Ref. MP A350-A-24-71-57-04ZZZ-720Z-A.
NOTE: It is not necessary to do the test requested in the installation procedure.

FOR FIN 1102-MC or RCCB-GALLEY FEEDER 10 AC

(c) Install defective RCCB on position of AC galley-feeder 10 RCCB (1102MC) Ref. MP A350-A-24-71-57-09ZZZ-720Z-A.
NOTE: It is not necessary to do the test requested in the installation procedure.

(4) Put a WARNING NOTICE(S) in position on defective RCCB to tell RCCB is inoperable.

(5) Install replacement RCCB (P1, P2 or P3) on position of the defective RCCB:
NOTE: It is necessary to do the test requested when all RCCB are installed.

(a) In EPDC1:

1) For RCCB ATA 24 Ref. MP A350-A-24-71-57-00ZZZ-720Z-A.

2) For RCCB ATA 21 Ref. MP A350-A-24-71-57-01ZZZ-720Z-A.


3) For RCCB ATA 27 Ref. MP A350-A-24-71-57-02ZZZ-720Z-A.

4) For RCCB ATA 28 Ref. MP A350-A-24-71-57-03ZZZ-720Z-A.

5) For RCCB ATA 29 Ref. MP A350-A-24-71-57-04ZZZ-720Z-A.


6) For RCCB ATA 30 Ref. MP A350-A-24-71-57-05ZZZ-720Z-A.

7) For RCCB ATA 38 Ref. MP A350-A-24-71-57-06ZZZ-720Z-A.

8) For RCCB ATA 49 Ref. MP A350-A-24-71-57-07ZZZ-720Z-A.


9) For RCCB ATA 78 Ref. MP A350-A-24-71-57-08ZZZ-720Z-A.

10) For RCCB ATA 25 Ref. MP A350-A-24-71-57-0HZZZ-720Z-A.

(b) In EPDC2:
1) For RCCB ATA 24 Ref. MP A350-A-24-71-57-09ZZZ-720Z-A.

2) For RCCB ATA 21 Ref. MP A350-A-24-71-57-0AZZZ-720Z-A.

3) For RCCB ATA 27 Ref. MP A350-A-24-71-57-0BZZZ-720Z-A.


Filtering is on: 3510 A350-A-24-71-57-00001-921A-A Page 6 of 10
Delta Air Lines Aircraft Maintenance Manual (AMM)
Printed: 8/29/2018; 09:33am.
Rev. 22 Aug-23-2018

4) For RCCB ATA 28 Ref. MP A350-A-24-71-57-0CZZZ-720Z-A.


5) For RCCB ATA 29 Ref. MP A350-A-24-71-57-0DZZZ-720Z-A.
6) For RCCB ATA 30 Ref. MP A350-A-24-71-57-0EZZZ-720Z-A.

7) For RCCB ATA 38 Ref. MP A350-A-24-71-57-0FZZZ-720Z-A.

8) For RCCB ATA 78 Ref. MP A350-A-24-71-57-0GZZZ-720Z-A.

ON A/C ALL

SUBTASK 247157-40100680001

D. Swapping of the RCCB Part Number 107CZ02L05Yxx


NOTE: The RCCBs which have the same P/N root must replace the NO GO RCCBs.

NOTE: It is possible that RCCBs of the same P/N root are not interchangeable. It is necessary to refer to the applicable IPD task to

know if you can interchange two RCCBs.

(1) Remove the defective RCCB (NO GO):


(a) From EPDC1:

1) For RCCB ATA 24 Ref. MP A350-A-24-71-57-00ZZZ-520Z-A.

2) For RCCB ATA 21 Ref. MP A350-A-24-71-57-01ZZZ-520Z-A.

3) For RCCB ATA 27 Ref. MP A350-A-24-71-57-02ZZZ-520Z-A.


4) For RCCB ATA 28 Ref. MP A350-A-24-71-57-03ZZZ-520Z-A.

5) For RCCB ATA 29 Ref. MP A350-A-24-71-57-04ZZZ-520Z-A.


6) For RCCB ATA 30 Ref. MP A350-A-24-71-57-05ZZZ-520Z-A.

7) For RCCB ATA 38 Ref. MP A350-A-24-71-57-06ZZZ-520Z-A.

8) For RCCB ATA 49 Ref. MP A350-A-24-71-57-07ZZZ-520Z-A.


9) For RCCB ATA 78 Ref. MP A350-A-24-71-57-08ZZZ-520Z-A.

10) For RCCB ATA 25 Ref. MP A350-A-24-71-57-0HZZZ-520Z-A.


(b) From EPDC2:
1) For RCCB ATA 24 Ref. MP A350-A-24-71-57-09ZZZ-520Z-A.

2) For RCCB ATA 21 Ref. MP A350-A-24-71-57-0AZZZ-520Z-A.


3) For RCCB ATA 27 Ref. MP A350-A-24-71-57-0BZZZ-520Z-A.

4) For RCCB ATA 28 Ref. MP A350-A-24-71-57-0CZZZ-520Z-A.


5) For RCCB ATA 29 Ref. MP A350-A-24-71-57-0DZZZ-520Z-A.

6) For RCCB ATA 30 Ref. MP A350-A-24-71-57-0EZZZ-520Z-A.


7) For RCCB ATA 38 Ref. MP A350-A-24-71-57-0FZZZ-520Z-A.

8) For RCCB ATA 78 Ref. MP A350-A-24-71-57-0GZZZ-520Z-A.

(2) Remove the RCCB which will be used to solve NO GO Configuration:


NOTE: P1 is related to the first RCCB that must be used for the replacement.

NOTE: It is mandatory to secure ATA28 RCCBs (refer to ATA28 MEL). If there is a monitoring failure on defective RCCBs

installed in the ATA28 position, these RCCBs have the status NO GO. To remove this status, it is necessary to use

P1 for the replacement.

Table 9

Priority Designation FIN position Procedure

20A/25A P1 RCCB-APU START AC

(1001KA)
4327XZ Ref. MP A350-A-24-71-57-07ZZZ-520Z-A

15A P2 RCCB-PUMP STBY 2

SPLY(1000QA)
4308XZ Ref. MP A350-A-24-71-57-0CZZZ-520Z-A

Filtering is on: 3510 A350-A-24-71-57-00001-921A-A Page 7 of 10


Delta Air Lines Aircraft Maintenance Manual (AMM)
Printed: 8/29/2018; 09:33am.
Rev. 22 Aug-23-2018

15A P3 RCCB-PUMP STBY 1

SPLY(1001QA)
4337XZ Ref. MP A350-A-24-71-57-03ZZZ-520Z-A

(3) Install the defective RCCB on position of the replacement RCCB (P1, P2 or P3):
FOR FIN 1001-KA or RCCB-APU START AC

(a) Install defective RCCB on position of APU start-AC RCCB (1001KA) Ref. MP A350-A-24-71-57-07ZZZ-720Z-A.
NOTE: It is not necessary to do the test requested in the installation procedure.

FOR FIN 1000-QA or RCCB-PUMP STBY 2 SPLY

(b) Install defective RCCB on position of standby-supply-pump 2 RCCB (1000QA) Ref. MP A350-A-24-71-57-0CZZZ-720Z-A.

NOTE: It is not necessary to do the test requested in the installation procedure.


FOR FIN 1001-QA or RCCB-PUMP STBY 1 SPLY

(c) Install defective RCCB on position of standby-supply-pump 1 RCCB (1001QA) Ref. MP A350-A-24-71-57-03ZZZ-720Z-A.

NOTE: It is not necessary to do the test requested in the installation procedure.

(4) Put a WARNING NOTICE(S) in position on defective RCCB to tell RCCB is inoperable.

(5) Install replacement RCCB (P1, P2 or P3) on position of the defective RCCB:
NOTE: It is necessary to do the test requested when all RCCB are installed.

(a) In EPDC1:
1) For RCCB ATA 24 Ref. MP A350-A-24-71-57-00ZZZ-720Z-A.

2) For RCCB ATA 21 Ref. MP A350-A-24-71-57-01ZZZ-720Z-A.

3) For RCCB ATA 27 Ref. MP A350-A-24-71-57-02ZZZ-720Z-A.


4) For RCCB ATA 28 Ref. MP A350-A-24-71-57-03ZZZ-720Z-A.

5) For RCCB ATA 29 Ref. MP A350-A-24-71-57-04ZZZ-720Z-A.


6) For RCCB ATA 30 Ref. MP A350-A-24-71-57-05ZZZ-720Z-A.

7) For RCCB ATA 38 Ref. MP A350-A-24-71-57-06ZZZ-720Z-A.

8) For RCCB ATA 49 Ref. MP A350-A-24-71-57-07ZZZ-720Z-A.


9) For RCCB ATA 78 Ref. MP A350-A-24-71-57-08ZZZ-720Z-A.

10) For RCCB ATA 25 Ref. MP A350-A-24-71-57-0HZZZ-720Z-A.


(b) In EPDC2:

1) For RCCB ATA 24 Ref. MP A350-A-24-71-57-09ZZZ-720Z-A.

2) For RCCB ATA 21 Ref. MP A350-A-24-71-57-0AZZZ-720Z-A.


3) For RCCB ATA 27 Ref. MP A350-A-24-71-57-0BZZZ-720Z-A.

4) For RCCB ATA 28 Ref. MP A350-A-24-71-57-0CZZZ-720Z-A.

5) For RCCB ATA 29 Ref. MP A350-A-24-71-57-0DZZZ-720Z-A.

6) For RCCB ATA 30 Ref. MP A350-A-24-71-57-0EZZZ-720Z-A.


7) For RCCB ATA 38 Ref. MP A350-A-24-71-57-0FZZZ-720Z-A.

8) For RCCB ATA 78 Ref. MP A350-A-24-71-57-0GZZZ-720Z-A.

ON A/C ALL
SUBTASK 247157-40100700001

E. Swapping of the RCCB Part Number 115CZ02Yxx

NOTE: The RCCBs which have the same P/N root must replace the NO GO RCCBs.

NOTE: It is possible that RCCBs of the same P/N root are not interchangeable. It is necessary to refer to the applicable IPD task to

know if you can interchange two RCCBs.


NOTE: There are some limitations/constraints associated to each swapping proposition, please refer to the MEL.

(1) Remove the defective RCCB (NO GO):

Filtering is on: 3510 A350-A-24-71-57-00001-921A-A Page 8 of 10


Delta Air Lines Aircraft Maintenance Manual (AMM)
Printed: 8/29/2018; 09:33am.
Rev. 22 Aug-23-2018

(a) From EPDC1:

1) For RCCB ATA 24 Ref. MP A350-A-24-71-57-00ZZZ-520Z-A.


2) For RCCB ATA 27 Ref. MP A350-A-24-71-57-02ZZZ-520Z-A.

3) For RCCB ATA 28 Ref. MP A350-A-24-71-57-03ZZZ-520Z-A.

4) For RCCB ATA 30 Ref. MP A350-A-24-71-57-05ZZZ-520Z-A.

(b) From EPDC2:

1) For RCCB ATA 24 Ref. MP A350-A-24-71-57-09ZZZ-520Z-A.


2) For RCCB ATA 27 Ref. MP A350-A-24-71-57-0BZZZ-520Z-A.

3) For RCCB ATA 28 Ref. MP A350-A-24-71-57-0CZZZ-520Z-A.

4) For RCCB ATA 30 Ref. MP A350-A-24-71-57-0EZZZ-520Z-A.

(2) Remove the RCCB which will be used to solve NO GO Configuration on RCCB of:

(a) For EPDC1:


Table 10

Designation FIN position Procedure

RCCB-PUMP MAIN 2 4565XZ Ref. MP A350-A-24-71-57-03ZZZ-520Z-A


SPLY (2001QA)

RCCB-PUMP MAIN 1 4552XZ Ref. MP A350-A-24-71-57-0CZZZ-520Z-A

SPLY (2000QA)

RCCB-ADGB MCE 4554XZ Ref. MP A350-A-24-71-57-0BZZZ-520Z-A


EMOT PWR (2008CV)

(b) For EPDC2:

Table 11

Designation FIN position Procedure

RCCB-PUMP MAIN 1 4552XZ Ref. MP A350-A-24-71-57-0CZZZ-520Z-A

SPLY (2000QA)

RCCB-PUMP MAIN 2 4565XZ Ref. MP A350-A-24-71-57-03ZZZ-520Z-A

SPLY (2001QA)

RCCB-ADGB MCE 4554XZ Ref. MP A350-A-24-71-57-0BZZZ-520Z-A


EMOT PWR (2008CV)

(3) Install the defective RCCB on position of the replacement RCCB:

FOR FIN 2000-QA or RCCB-PUMP MAIN 1 SPLY


(a) Install defective RCCB at location of main-supply-pump 1 RCCB (2000QA) Ref. MP A350-A-24-71-57-0CZZZ-720Z-A.

NOTE: It is not necessary to do the test requested in the installation procedure.


FOR FIN 2001-QA or RCCB-PUMP MAIN 2 SPLY

(b) Install defective RCCB at location of main-supply-pump 2 RCCB (2001QA) Ref. MP A350-A-24-71-57-03ZZZ-720Z-A.

NOTE: It is not necessary to do the test requested in the installation procedure.


FOR FIN 2008-CV or RCCB-ADGB MCE EMOT PWR

(c) Install defective RCCB at location of the ADGB-MCE-EMOT power RCCB (2008CV) Ref. MP A350-A-24-71-57-0BZZZ-

720Z-A.

NOTE: It is not necessary to do the test requested in the installation procedure.

(4) Put a WARNING NOTICE(S) in position on defective RCCB to tell RCCB is inoperable.
(5) Install replacement RCCB on position of the defective RCCB:

Filtering is on: 3510 A350-A-24-71-57-00001-921A-A Page 9 of 10


Delta Air Lines Aircraft Maintenance Manual (AMM)
Printed: 8/29/2018; 09:33am.
Rev. 22 Aug-23-2018

NOTE: It is necessary to do the test requested when all RCCB are installed.

(a) In EPDC1:
1) For RCCB ATA 24 Ref. MP A350-A-24-71-57-00ZZZ-720Z-A.
2) For RCCB ATA 27 Ref. MP A350-A-24-71-57-02ZZZ-720Z-A.

3) For RCCB ATA 28 Ref. MP A350-A-24-71-57-03ZZZ-720Z-A.

4) For RCCB ATA 30 Ref. MP A350-A-24-71-57-05ZZZ-720Z-A.


(b) In EPDC2:

1) For RCCB ATA 24 Ref. MP A350-A-24-71-57-09ZZZ-720Z-A.


2) For RCCB ATA 27 Ref. MP A350-A-24-71-57-0BZZZ-720Z-A.
3) For RCCB ATA 28 Ref. MP A350-A-24-71-57-0CZZZ-720Z-A.

4) For RCCB ATA 30 Ref. MP A350-A-24-71-57-0EZZZ-720Z-A.


ON A/C ALL

SUBTASK 247157-50000360001
F. Test after swapping of the RCCB
(1) Energize the aircraft electrical circuits
Ref. MP A350-A-24-41-XX-00ZZZ-761Z-A

(2) On the ECAM display, on the SD, on the “DISPATCH” page:

(a) Record the messages shown on ECAM display.


(b) Compare the message(s) shown with the message(s) recorded before swapping:
1) If the new message is GOIF, apply MEL.

2) If the new message is NOGO, do the related trouble shooting procedure.


5. Close-Up
ON A/C ALL
SUBTASK 247157-10200350001
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Make an applicable entry in the logbook.
(3) De-energize the aircraft electrical circuits
Ref. MP A350-A-24-41-XX-00ZZZ-561Z-A.

6. Required Conditions

Table 12 Required Conditions

Title/Condition Data Module/Technical Publication

None

Filtering is on: 3510 A350-A-24-71-57-00001-921A-A Page 10 of 10


Delta Air Lines
Printed: 8/29/2018; 07:13am.
Aircraft Maintenance Manual (AMM)
Installation Procedure
Rev. 22 Aug-23-2018

(1) Put on an ELECTRICALLY GROUNDED WRIST STRAP, and connect the wrist strap cable to the grounding connector (7) of

EPDC1.
FOR FIN 1011-MC or RCCB-GALLEY FEEDER 1 AC or FOR FIN 1031-MC or RCCB-GALLEY FEEDER 3 AC or FOR FIN 1051-MC

or RCCB-GALLEY FEEDER 5 AC or FOR FIN 1091-MC or RCCB-GALLEY FEEDER 9 AC or FOR FIN 1021-XP or RCCB-121XP or

FOR FIN 1023-XP or RCCB-123XP or FOR FIN 1025-XP or RCCB-125XP or FOR FIN 1027-XP or RCCB-127XP or FOR FIN 1033-X

P or RCCB-133XP

(2) Put on an ELECTRICALLY GROUNDED WRIST STRAP, and connect the wrist strap cable to a grounding point near the work
area.

4. Procedure

See Graphic figs040001

ON A/C 3501, 3502, 3503, 3504, 3505, 3506, 3507, 3508, 3509, 3510, 3511

CAUTION: BE CAREFUL WHEN YOU OPERATE THE RCCB SELECTOR KNOB. THIS COMPONENT CAN BE EASILY

DAMAGED.

SUBTASK 247157-10100940006

B. Preparation for Installation


FOR FIN 1001-PU or RCCB-TR1

(1) Put the selector knob (5) to the 20A/25A position.


25A
1021-XP FOR FIN 1021-XP or RCCB-121XP or FOR FIN 1023-XP or RCCB-123XP

(2) Put the selector knob (5) to the 35A position. 35A
FOR FIN 1011-MC or RCCB-GALLEY FEEDER 1 AC or FOR FIN 1031-MC or RCCB-GALLEY FEEDER 3 AC or FOR FIN 1051-MC

or RCCB-GALLEY FEEDER 5 AC or FOR FIN 1091-MC or RCCB-GALLEY FEEDER 9 AC or FOR FIN 1025-XP or RCCB-125XP or

FOR FIN 1027-XP or RCCB-127XP or FOR FIN 1033-XP or RCCB-133XP

(3) Put the selector knob (5) to the 50A position.


ON A/C 3501, 3502, 3503, 3504, 3505, 3506, 3507, 3508, 3509, 3510, 3511
50A
SUBTASK 247157-40100020006
D. Installation of the ATA24 RCCB in EPDC1
FOR FIN 1011-MC or RCCB-GALLEY FEEDER 1 AC or FOR FIN 1031-MC or RCCB-GALLEY FEEDER 3 AC or FOR FIN 1051-MC

or RCCB-GALLEY FEEDER 5 AC or FOR FIN 1091-MC or RCCB-GALLEY FEEDER 9 AC or FOR FIN 2001-PE or RCCB-EMER TR

1 or FOR FIN 1001-PU or RCCB-TR1 or FOR FIN 2001-XH or RCCB-EMER ATU1 or FOR FIN 1021-XP or RCCB-121XP or FOR FI

N 1023-XP or RCCB-123XP or FOR FIN 1025-XP or RCCB-125XP or FOR FIN 1027-XP or RCCB-127XP or FOR FIN 1033-XP or R

CCB-133XP
(1) Installation of the RCCB

(a) Do a visual inspection and clean the component interfaces and the adjacent area.

(b) Remove the RCCB (2) from the BAG - ANTISTATIC.

(c) Make sure that all the electrical connections are clean and in the correct condition.

(d) Put the RCCB (2) in position on the current transformer plate (3) and engage the locating pins (4) in the related holes of

the RCCB (2).


(e) TORQUE the captive screws (1) to between 0.08 and 0.09 m.daN (7.08 and 7.96 lbf.in) .

(f) Apply a drop of 04TME5 (Varnish_- Marking System) on the captive screws (1) and on the RCCB (2).

ON A/C 3501, 3502, 3503, 3504, 3505, 3506, 3507, 3508, 3509, 3510, 3511

Filtering is on: 3510 A350-A-24-71-57-00001-720A-A Page 5 of 7