Vendor must provide supporting PQRs for the following WPS;
o 03B-2021, 03-2021, 03FW-2021
o 05-2021 o 06-2021 o 07-2021 o 08-2021 F Number for E 16.8.2-15 is 5 as per AMSE Section IX (QW-432). Correction needed in following documents: o PQR no. 04-2020 o WPS no 04-2020, 4B-2020 and 4FW-2020. As per ASME section IX (QW-451.1), 04 side bend tests are required for PQR no. 04- 2020. Tensile and Bend test results are missing in the PQR no. 02-2021 and PQR no. 03-2021. Test coupon thickness of PQR no. 04-2021 (i.e. 13mm) doesn’t support the thickness range to be qualified in the following WPS. o 04B-2021, 04-2021, 04FW-2021 (i.e. 1,5÷17,12 mm) Supporting PQRs for the WPS nos. 04B-2020, 04FW-2020 are 04-2020 (04-2021) Max weld deposit thickness (2+38.88 mm max.) as per WPS no 04-2020 and WPS no 04B-2020 is not in concurrence with Thickness Range qualified (42.88mm max.). WPS no. 06-2021 must be qualified for the base metal thickness of 11.13mm (10.97mm) WPS no. 07-2021 must be qualified for the base metal thickness of 6.02mm & 11.13mm (13mm) No WPS is available to cover the welds W-438, W-439, W-444, W-445, W-447, W-448, W-453, W-454, W-457, W-456, W-464, W-465, W-467, W-468, W-473, W-474 Inspection company representative stamp is missing on few WPS.