You are on page 1of 67

LOTE AREA LOTE AREA

1 471.6 65 357
2 346.5 66 331.5
3 340.7 67 324
4 343.1 68 520.4
5 343.1 69 396.2
6 480 70 340
7 325.6 71 429.8
8 263.5 72 360.4
9 451.5 73 323
10 247 74 314.5
11 388.5 75 231.1
12 342.6 76 386
13 386.8 77 387.6
14 361 78 387.6
15 335 79 338
16 399 80 459
17 374 81 360
18 405 82 360
19 370 83 452
20 370 84 434
21 370 85 434
22 366 86 434
23 374 87 434
24 405 88 435
25 370 89 451.5
26 370 90 418
27 370 91 442
28 366 92 328
29 399 93 404.8
30 315 94 456.8
31 382.3 95 280.5
32 317.9 96 317.9
33 355.8 97 317.9
34 317.9 98 482.3
35 442 99 315
36 404.8 100 386.8
37 280.5 101 335
38 328 102 361
39 418 103 342.6
40 451.1 104 480
41 435 105 343.1
42 434 106 343.1
43 434 107 340.7
44 434 108 346.5
45 434 109 471.6
46 452 110 325.6
47 460 111 388.5
48 460 112 451.5
49 459 113 263.5
50 338 114 247
51 387.6
52 387.6
53 386
54 360.4
55 323
56 314.5
57 231
58 357
59 331.5
60 324
61 520.4
62 429.8
63 340
64 396.2
SUELOS - HORMIGONES - ASFALTOS

ENSAYO DE COMPRESION SIMPLE


D-2166

ENSAYO - DISEÑO - CONTROL

PROYECTO : TEMPLO P-2


UBICACIÓN : SANGOLQUÍ
LOCALIZACIO
: AV. GENERAL RUMIÑAHUI
MUESTRA No.
:1

DESCRIPCIÓN DEL SUELOCAFÉ OSCURO CON MEDIANA HUMEDAD


MASA DEL SUELO: MUESTRA
masa: 144.15 gr
altura: 7.63 cm 3.00393700787 in
diámetro 3.7 cm
Área 10.75 cm2 1.67
Volumen: 82.0385295382 cm3
ᵞ 1.75710121587

VAR. DEF VAR. DEF DEF. VERT LECTURA DIAL LECTURA CARGA X AREA
(in.) (cm) (CM) DEF. VERT % (lb) DIAL (kg) FACTOR CORREGIDA
0 0 0 0% 0 0 0 10.7521009
0.01 0.0254 0.0033289646 0% 3 6.615 1.0881675 10.7880138
0.02 0.0508 0.0066579292 1% 8 17.64 2.90178 10.8241674
0.03 0.0762 0.0099868938 1% 13 28.665 4.7153925 10.8605642
0.04 0.1016 0.0133158585 1% 19 41.895 6.8917275 10.8972065
0.05 0.127 0.0166448231 2% 27 59.535 9.7935075 10.934097
0.06 0.1524 0.0199737877 2% 33 72.765 11.9698425 10.971238
0.07 0.1778 0.0233027523 2% 40 88.2 14.5089 11.0086323
0.08 0.2032 0.0266317169 3% 47 103.635 17.0479575 11.0462823
0.09 0.2286 0.0299606815 3% 53 116.865 19.2242925 11.0841908
0.1 0.254 0.0332896461 3% 59 130.095 21.4006275 11.1223603
0.11 0.2794 0.0366186107 4% 62 136.71 22.488795 11.1607936
0.12 0.3048 0.0399475754 4% 64 141.12 23.21424 11.1994935
0.13 0.3302 0.04327654 4% 63 138.915 22.8515175 11.2384626
0.14 0.3556 0.0466055046 5% 60 132.3 21.76335 11.2777039

VAR. DEF DEF. VERT LECTURA DIAL CARGA X AREA ESFUERZO


(in.) (in) (lb) FACTOR CORREGIDA NORMAL
0 0 0 0 1.666578966 0
0.01 0.00332896 3 1.086 1.6721454791 0.64946502
0.02 0.00665793 8 2.896 1.6777493021 1.72612201
0.03 0.00998689 13 4.706 1.6833908113 2.79554811
0.04 0.01331586 19 6.878 1.6890703882 4.07206239
0.05 0.01664482 27 9.774 1.6947884194 5.76709157
0.06 0.01997379 33 11.946 1.7005452967 7.02480553
0.07 0.02330275 40 14.48 1.7063414174 8.48599222
0.08 0.02663172 47 17.014 1.712177184 9.93705567
0.09 0.02996068 53 19.186 1.7180530049 11.1672922
0.1 0.03328965 59 21.358 1.7239692937 12.3888517
0.11 0.03661861 62 22.444 1.72992647 12.9739618
0.12 0.03994758 64 23.168 1.7359249591 13.346199
0.13 0.04327654 63 22.806 1.7419651923 13.09211
0.14 0.0466055 60 21.72 1.7480476067 12.4252909
RESION SIMPLE
6

FECHA : 22/07/2021
REALIZADO : S.G.
REVISADO : ING. SEGUNDO GUANOLOQUIN
SOLICITADO : ING. RICHARD MORALES TEXTEX

ESFUERZO
NORMAL
Chart Title
0
0.1008682 2.5
0.26808344
0.43417565 2
0.63243066
0.89568508 1.5
1.09102022
1.31795664 1
1.54332082
1.73438846
0.5
1.92410846
2.01498171
2.07279374 0
0% 1% 1% 2% 2% 3% 3% 4% 4% 5% 5%
2.03333127
1.92976781

Chart Title
16

14

12
Chart Title
16

14

12

10

0
0 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 0.045 0.05
5% 5%
045 0.05
SUELOS - HORMIGONES - ASFALTOS

ENSAYO DE COMPRESION SIMPLE


D-2166

ENSAYO - DISEÑO - CONTROL

PROYECTO : TEMPLO P-2


UBICACIÓN : SANGOLQUÍ
LOCALIZACIO
: AV. GENERAL RUMIÑAHUI
MUESTRA No.
:1

DESCRIPCIÓN DEL SUELOCAFÉ OSCURO CON MEDIANA HUMEDAD


MASA DEL SUELO: MUESTRA
masa: 139.83 gr
altura: 7.4 cm 2.91338582677 in
diámetro 3.7 cm
Área 10.75 cm2 1.67
Volumen: 79.5655463411 cm3
ᵞ 1.75741896374

VAR. DEF VAR. DEF DEF. VERT LECTURA DIAL LECTURA CARGA X AREA
(in.) (cm) (CM) DEF. VERT % (lb) DIAL (kg) FACTOR CORREGIDA
0 0 0 0% 0 0 0 10.7521009
0.01 0.0254 0.0034324324 0% 5 11.025 1.8136125 10.7891338
0.02 0.0508 0.0068648649 1% 11 24.255 3.9899475 10.8264228
0.03 0.0762 0.0102972973 1% 18 39.69 6.529005 10.8639704
0.04 0.1016 0.0137297297 1% 26 57.33 9.430785 10.9017793
0.05 0.127 0.0171621622 2% 33 72.765 11.9698425 10.9398524
0.06 0.1524 0.0205945946 2% 40 88.2 14.5089 10.9781923
0.07 0.1778 0.024027027 2% 46 101.43 16.685235 11.0168019
0.08 0.2032 0.0274594595 3% 54 119.07 19.587015 11.055684
0.09 0.2286 0.0308918919 3% 59 130.095 21.4006275 11.0948415
0.1 0.254 0.0343243243 3% 62 136.71 22.488795 11.1342774
0.11 0.2794 0.0377567568 4% 66 145.53 23.939685 11.1739947
0.12 0.3048 0.0411891892 4% 69 152.145 25.0278525 11.2139963
0.13 0.3302 0.0446216216 4% 69 152.145 25.0278525 11.2542853
0.14 0.3556 0.0480540541 5% 64 141.12 23.21424 11.2948649
0.15 0.381 0.0514864865 5% 56 123.48 20.31246 11.3357382
0.16 0.4064 0.0549189189 5% 50 110.25 18.136125 11.3769084
VAR. DEF DEF. VERT LECTURA DIAL CARGA X AREA ESFUERZO
(in.) (in) (lb) FACTOR CORREGIDA NORMAL
0 0 0 0 1.666578966 0
0.01 0.00343243 5 1.81 1.6723190883 1.08232933
0.02 0.00686486 11 3.982 1.6780988881 2.37292333
0.03 0.0102973 18 6.516 1.6839187783 3.8695453
0.04 0.01372973 26 9.412 1.6897791774 5.56995856
0.05 0.01716216 33 11.946 1.6956805099 7.0449592
0.06 0.02059459 40 14.48 1.7016232061 8.50952194
0.07 0.02402703 46 16.652 1.7076077024 9.7516543
0.08 0.02745946 54 19.548 1.7136344415 11.4073338
0.09 0.03089189 59 21.358 1.7197038721 12.4195801
0.1 0.03432432 62 22.444 1.7258164495 13.0048592
0.11 0.03775676 66 23.892 1.7319726355 13.7946752
0.12 0.04118919 69 24.978 1.7381728983 14.370262
0.13 0.04462162 69 24.978 1.7444177131 14.3188181
0.14 0.04805405 64 23.168 1.7507075618 13.2335066
0.15 0.05148649 56 20.272 1.7570429332 11.5375667
0.16 0.05491892 50 18.1 1.7634243234 10.2641206
RESION SIMPLE
6

FECHA : 22/07/2021
REALIZADO : S.G.
REVISADO : ING. SEGUNDO GUANOLOQUIN
SOLICITADO : ING. RICHARD MORALES TEXTEX

ESFUERZO
NORMAL
Chart Title
0
0.16809621 2.5
0.36853794
0.6009778 2
0.86506842
1.09415028 1.5
1.32161103
1.5145262 1
1.77166922
1.92888087
0.5
2.01978038
2.14244643
2.23184063 0
0% 1% 2% 3% 4% 5% 6%
2.2238509
2.05529151
1.79189565
1.59411717
Chart Title
16

14

12

10

0
0 0.01 0.02 0.03 0.04 0.05 0.06
6%
0.06
SUELOS - HORMIGONES - ASFALTOS

ENSAYO DE COMPRESION SIMPLE


D-2166

ENSAYO - DISEÑO - CONTROL

PROYECTO : TEMPLO P-2


UBICACIÓN : SANGOLQUÍ
LOCALIZACIO
: AV. GENERAL RUMIÑAHUI
MUESTRA No.
:1

DESCRIPCIÓN DEL SUELOCAFÉ OSCURO CON MEDIANA HUMEDAD


MASA DEL SUELO: MUESTRA
masa: 114.82 gr
altura: 6.1 cm 2.40157480315 in
diámetro 3.7 cm
Área 10.75 cm2 1.67
Volumen: 65.5878152272 cm3
ᵞ 1.75063004618

VAR. DEF VAR. DEF DEF. VERT LECTURA DIAL LECTURA CARGA X AREA
(in.) (cm) (CM) DEF. VERT % (lb) DIAL (kg) FACTOR CORREGIDA
0 0 0 0% 0 0 0 10.7521009
0.01 0.0254 0.0041639344 0% 4 8.82 1.45089 10.7970591
0.02 0.0508 0.0083278689 1% 6 13.23 2.176335 10.8423949
0.03 0.0762 0.0124918033 1% 10 22.05 3.627225 10.888113
0.04 0.1016 0.0166557377 2% 13 28.665 4.7153925 10.9342183
0.05 0.127 0.0208196721 2% 16 35.28 5.80356 10.9807158
0.06 0.1524 0.0249836066 2% 22 48.51 7.979895 11.0276103
0.07 0.1778 0.029147541 3% 24 52.92 8.70534 11.0749072
0.08 0.2032 0.0333114754 3% 34 74.97 12.332565 11.1226115
0.09 0.2286 0.0374754098 4% 39 85.995 14.1461775 11.1707285
0.1 0.254 0.0416393443 4% 40 88.2 14.5089 11.2192636
0.11 0.2794 0.0458032787 5% 34 74.97 12.332565 11.2682224
0.12 0.3048 0.0499672131 5% 29 63.945 10.5189525 11.3176103
0.13 0.3302 0.0541311475 5% 25 55.125 9.0680625 11.3674331
0.14 0.3556 0.058295082 6% 20 44.1 7.25445 11.4176964

VAR. DEF DEF. VERT LECTURA DIAL CARGA X AREA ESFUERZO


(in.) (in) (lb) FACTOR CORREGIDA NORMAL
0 0 0 0 1.666578966 0
0.01 0.00416393 4 1.448 1.6735475081 0.8652279
0.02 0.00832787 6 2.172 1.6805745706 1.29241513
0.03 0.0124918 10 3.62 1.6876608939 2.14498067
0.04 0.01665574 13 4.706 1.6948072307 2.77671697
0.05 0.02081967 16 5.792 1.7020143466 3.40302654
0.06 0.02498361 22 7.964 1.7092830205 4.65926351
0.07 0.02914754 24 8.688 1.7166140442 5.06112602
0.08 0.03331148 34 12.308 1.7240082235 7.13917708
0.09 0.03747541 39 14.118 1.7314663781 8.15378235
0.1 0.04163934 40 14.48 1.7389893419 8.32667553
0.11 0.04580328 34 12.308 1.7465779632 7.04692276
0.12 0.04996721 29 10.498 1.7542331054 5.98438142
0.13 0.05413115 25 9.05 1.7619556471 5.13633815
0.14 0.05829508 20 7.24 1.7697464822 4.09098143
RESION SIMPLE
6

FECHA : 22/07/2021
REALIZADO : S.G.
REVISADO : ING. SEGUNDO GUANOLOQUIN
SOLICITADO : ING. RICHARD MORALES TEXTEX

ESFUERZO
NORMAL
Chart Title
0
0.13437826 1.4
0.20072457 1.2
0.33313624
0.43125099 1
0.52852292
0.8
0.72362867
0.7860418 0.6
1.10878323
0.4
1.26636123
1.29321322 0.2
1.09445524
0.92943229 0
0% 1% 2% 3% 4% 5% 6% 7%
0.79772297
0.63536897

Chart Title
9
8
7
Chart Title
9
8
7
6
5
4
3
2
1
0
0 0.01 0.02 0.03 0.04 0.05 0.06 0.07
% 7%
0.07
SUELOS - HORMIGONES - ASFALTOS

ENSAYO DE COMPRESION SIMPLE


D-2166

ENSAYO - DISEÑO - CONTROL

PROYECTO : TEMPLO P-2


UBICACIÓN : SANGOLQUÍ
LOCALIZACIO
: AV. GENERAL RUMIÑAHUI
MUESTRA No.
:1

DESCRIPCIÓN DEL SUELOCAFÉ OSCURO CON MEDIANA HUMEDAD


MASA DEL SUELO: MUESTRA
masa: 132.96 gr
altura: 6.9 cm 2.71653543307 in
diámetro 3.7 cm
Área 10.75 cm2 1.67
Volumen: 74.1894959127 cm3
ᵞ 1.79216745395

VAR. DEF VAR. DEF DEF. VERT LECTURA DIAL LECTURA CARGA X AREA
(in.) (cm) (CM) DEF. VERT % (lb) DIAL (kg) FACTOR CORREGIDA
0 0 0 0% 0 0 0 10.7521009
0.01 0.0254 0.0036811594 0% 8 17.64 2.90178 10.7918273
0.02 0.0508 0.0073623188 1% 32 70.56 11.60712 10.8318484
0.03 0.0762 0.0110434783 1% 67 147.735 24.3024075 10.8721674
0.04 0.1016 0.0147246377 1% 88 194.04 31.91958 10.9127877
0.05 0.127 0.0184057971 2% 144 317.52 52.23204 10.9537127
0.06 0.1524 0.0220869565 2% 174 383.67 63.113715 10.9949457
0.07 0.1778 0.0257681159 3% 113 249.165 40.9876425 11.0364904
0.08 0.2032 0.0294492754 3% 105 231.525 38.0858625 11.0783502
0.09 0.2286 0.0331304348 3% 100 220.5 36.27225 11.1205288
0.1 0.254 0.0368115942 4% 83 183.015 30.1059675 11.1630298

VAR. DEF DEF. VERT LECTURA DIAL CARGA X AREA ESFUERZO


(in.) (in) (lb) FACTOR CORREGIDA NORMAL
0 0 0 0 1.666578966 0
0.01 0.00368116 8 2.896 1.672736576 1.73129472 40
0.02 0.00736232 32 11.584 1.6789398565 6.899592 35
0.03 0.01104348 67 24.254 1.6851893176 14.3924482 30
0.04 0.01472464 88 31.856 1.6914854768 18.8331502
25

20

15
40

35

30

25
0.05 0.0184058 144 52.128 1.6978288595 30.7027412
0.06 0.02208696 174 62.988 1.704219999 36.9600169 20
0.07 0.02576812 113 40.906 1.7106594367 23.912416 15
0.08 0.02944928 105 38.01 1.7171477221 22.1355446
10
0.09 0.03313043 100 36.2 1.7236854131 21.0015121
5
0.1 0.03681159 83 30.046 1.7302730763 17.3648891
0
0 0.005 0.01
RESION SIMPLE
6

FECHA : 22/07/2021
REALIZADO : S.G.
REVISADO : ING. SEGUNDO GUANOLOQUIN
SOLICITADO : ING. RICHARD MORALES TEXTEX

Chart Title
7
ESFUERZO
NORMAL
6
0
0.26888681 5
1.07157335
4
2.23528636
2.92497031 3
4.76843255
5.74024797 2

3.71382939 1
3.43786409
3.26173787 0
0% 1% 1% 2% 2% 3% 3% 4% 4%
2.69693516

Chart Title
40

35

30

25

20

15
40

35

30

25

20

15

10

0
0 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04
SUELOS - HORMIGONES - ASFALTOS

ENSAYO DE COMPRESION SIMPLE


D-2166

ENSAYO - DISEÑO - CONTROL

PROYECTO : TEMPLO P-2


UBICACIÓN : SANGOLQUÍ
LOCALIZACIO
: AV. GENERAL RUMIÑAHUI
MUESTRA No.
:1

DESCRIPCIÓN DEL SUELOCAFÉ OSCURO CON MEDIANA HUMEDAD


MASA DEL SUELO: MUESTRA
masa: 148.4 gr
altura: 7.7 cm 3.03149606299 in
diámetro 3.7 cm
Área 10.75 cm2 1.67
Volumen: 82.7911765982 cm3
ᵞ 1.79246154116

VAR. DEF VAR. DEF DEF. VERT LECTURA DIAL LECTURA CARGA X AREA
(in.) (cm) (CM) DEF. VERT % (lb) DIAL (kg) FACTOR CORREGIDA
0 0 0 0% 0 0 0 10.7521009
0.01 0.0254 0.0032987013 0% 10 22.05 3.627225 10.7876862
0.02 0.0508 0.0065974026 1% 25 55.125 9.0680625 10.8235079
0.03 0.0762 0.0098961039 1% 37 81.585 13.4207325 10.8595683
0.04 0.1016 0.0131948052 1% 50 110.25 18.136125 10.8958697
0.05 0.127 0.0164935065 2% 64 141.12 23.21424 10.9324147
0.06 0.1524 0.0197922078 2% 73 160.965 26.4787425 10.9692057
0.07 0.1778 0.0230909091 2% 87 191.835 31.5568575 11.0062451
0.08 0.2032 0.0263896104 3% 98 216.09 35.546805 11.0435355
0.09 0.2286 0.0296883117 3% 113 249.165 40.9876425 11.0810794
0.1 0.254 0.032987013 3% 122 269.01 44.252145 11.1188795
0.11 0.2794 0.0362857143 4% 130 286.65 47.153925 11.1569383
0.12 0.3048 0.0395844156 4% 139 306.495 50.4184275 11.1952586
0.13 0.3302 0.0428831169 4% 140 308.7 50.78115 11.2338431
0.14 0.3556 0.0461818182 5% 128 282.24 46.42848 11.2726944
0.15 0.381 0.0494805195 5% 116 255.78 42.07581 11.3118154

VAR. DEF DEF. VERT LECTURA DIAL CARGA X AREA ESFUERZO


(in.) (in) (lb) FACTOR CORREGIDA NORMAL
0 0 0 0 1.666578966 0
0.01 0.0032987 10 3.62 1.672094707 2.16494914
0.02 0.0065974 25 9.05 1.6776470792 5.39445996
0.03 0.0098961 37 13.394 1.6832364488 7.95728967
0.04 0.01319481 50 18.1 1.6888631867 10.7172684
0.05 0.01649351 64 23.168 1.6945276691 13.6722465
0.06 0.01979221 73 26.426 1.7002302769 15.5426005
0.07 0.02309091 87 31.494 1.7059713964 18.4610364
0.08 0.02638961 98 35.476 1.711751419 20.7249719
0.09 0.02968831 113 40.906 1.7175707415 23.8161952
0.1 0.03298701 122 44.164 1.7234297661 25.6256454
0.11 0.03628571 130 47.06 1.7293289004 27.2128685
0.12 0.03958442 139 50.318 1.7352685577 28.9972407
0.13 0.04288312 140 50.68 1.7412491571 29.1055417
0.14 0.04618182 128 46.336 1.7472711233 26.519067
0.15 0.04948052 116 41.992 1.753334887 23.9497887
RESION SIMPLE
6

FECHA : 22/07/2021
REALIZADO : S.G.
REVISADO : ING. SEGUNDO GUANOLOQUIN
SOLICITADO : ING. RICHARD MORALES TEXTEX

ESFUERZO
NORMAL
Chart Title
0
0.33623753 5

0.83781179 4.5
1.23584402 4
1.6644954 3.5
2.12343207 3
2.41391613 2.5
2.86717744 2
3.21878851 1.5
3.69888537
1
3.97991048
0.5
4.22642159
0
4.50355183 0% 1% 1% 2% 2% 3% 3% 4% 4% 5% 5%
4.52037203
4.1186675
3.71963373

Chart Title
35

30

25
Chart Title
35

30

25

20

15

10

0
0 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 0.045 0.05
5% 5%
.045 0.05
SUELOS - HORMIGONES - ASFALTOS

ENSAYO DE COMPRESION SIMPLE


D-2166

ENSAYO - DISEÑO - CONTROL

PROYECTO : TEMPLO P-2


UBICACIÓN : SANGOLQUÍ
LOCALIZACIO
: AV. GENERAL RUMIÑAHUI
MUESTRA No.
:1

DESCRIPCIÓN DEL SUELOCAFÉ OSCURO CON MEDIANA HUMEDAD


MASA DEL SUELO: MUESTRA
masa: 146.16 gr
altura: 7.4 cm 2.91338582677 in
diámetro 3.7 cm
Área 10.75 cm2 1.67
Volumen: 79.5655463411 cm3
ᵞ 1.83697601187

VAR. DEF VAR. DEF DEF. VERT LECTURA DIAL LECTURA CARGA X AREA
(in.) (cm) (CM) DEF. VERT % (lb) DIAL (kg) FACTOR CORREGIDA
0 0 0 0% 0 0 0 10.7521009
0.01 0.0254 0.0034324324 0% 8 17.64 2.90178 10.7891338
0.02 0.0508 0.0068648649 1% 20 44.1 7.25445 10.8264228
0.03 0.0762 0.0102972973 1% 34 74.97 12.332565 10.8639704
0.04 0.1016 0.0137297297 1% 49 108.045 17.7734025 10.9017793
0.05 0.127 0.0171621622 2% 66 145.53 23.939685 10.9398524
0.06 0.1524 0.0205945946 2% 82 180.81 29.743245 10.9781923
0.07 0.1778 0.024027027 2% 99 218.295 35.9095275 11.0168019
0.08 0.2032 0.0274594595 3% 116 255.78 42.07581 11.055684
0.09 0.2286 0.0308918919 3% 134 295.47 48.604815 11.0948415
0.1 0.254 0.0343243243 3% 145 319.725 52.5947625 11.1342774
0.11 0.2794 0.0377567568 4% 154 339.57 55.859265 11.1739947
0.12 0.3048 0.0411891892 4% 157 346.185 56.9474325 11.2139963
0.13 0.3302 0.0446216216 4% 146 321.93 52.957485 11.2542853
0.14 0.3556 0.0480540541 5% 120 264.6 43.5267 11.2948649
0.15 0.381 0.0514864865 5% 82 180.81 29.743245 11.3357382

VAR. DEF DEF. VERT LECTURA DIAL CARGA X AREA ESFUERZO


(in.) (in) (lb) FACTOR CORREGIDA NORMAL
0 0 0 0 1.666578966 0
0.01 0.00343243 8 2.896 1.6723190883 1.73172693
0.02 0.00686486 20 7.24 1.6780988881 4.31440605
0.03 0.0102973 34 12.308 1.6839187783 7.30914113
0.04 0.01372973 49 17.738 1.6897791774 10.4972296
0.05 0.01716216 66 23.892 1.6956805099 14.0899184
0.06 0.02059459 82 29.684 1.7016232061 17.44452
0.07 0.02402703 99 35.838 1.7076077024 20.987256
0.08 0.02745946 116 41.992 1.7136344415 24.5046429
0.09 0.03089189 134 48.508 1.7197038721 28.2071819
0.1 0.03432432 145 52.49 1.7258164495 30.4145902
0.11 0.03775676 154 55.748 1.7319726355 32.1875755
0.12 0.04118919 157 56.834 1.7381728983 32.6975527
0.13 0.04462162 146 52.852 1.7444177131 30.2977891
0.14 0.04805405 120 43.44 1.7507075618 24.8128248
0.15 0.05148649 82 29.684 1.7570429332 16.8942941
RESION SIMPLE
6

FECHA : 22/07/2021
REALIZADO : S.G.
REVISADO : ING. SEGUNDO GUANOLOQUIN
SOLICITADO : ING. RICHARD MORALES TEXTEX

ESFUERZO
NORMAL
Chart Title
0
0.26895394 6
0.67006897
5
1.13518028
1.63032125
4
2.18830055
2.70930261 3
3.25952377
3.80580796 2
4.38084807
4.72367991 1
4.99904168
5.07824607 0
0% 1% 2% 3% 4% 5% 6%
4.70553958
3.85367159
2.62384721

Chart Title
35

30

25
Chart Title
35

30

25

20

15

10

0
0 0.01 0.02 0.03 0.04 0.05 0.06
6%
0.06

You might also like