You are on page 1of 3

INDEX A

BATTERY POWERED ELECTROMAGNETIC FLOW METER


WITH STAINLESS BOLT AND NUT

General Specifications:

A microprocessor-based water meter with graphical display and key for optimum customer operation and
information on site. The transmitter drives the magnetic field in the sensor, evaluates the flow signal from the sensor
and calculates the volume passing through. It delivers the required information via the integrated pulse output or
communication interfere as part of a system solution. Its intelligent functionality, information and diagnostic ensure
optimum meter performance and information to optimize water supply billing.
A battery powered water meter full bore magnetic flowmeter that complies with the WRAS and OIML R49
water meter standards, engineered for stand-alone water applications such as water abstraction, distribution network,
revenue metering and irrigation.

Technical Specifications:
Meter Technology – Electromagnetic Full bore with Bi-directional Measurement
Physical Specifications:
Pipe Diameter Р6ӯ
End Connection – Flanged
Process Operating Conditions:
Operating Pressure : 150 psi
Operating Temperature : 158 °F
Output Options:
Interfere Options - Serial/Digital
Communication:
Can be communicated via IrDA : Standard integrated infrared communication interfere with Mod-Bus RTU
Protocol
User Interface:
Front-Panel Computer Interfere – Controllable and configured via PC Computer
Features:
Programmable; Recorder/Totalizer
Programmable Functions, Recorder/Totalizer
Functions, Bi-directional Measurement
DIAGNOSTIC
Should have a configuration tools and software for field Diagnostic Test and Parameter Changes and for
uploading/downloading measure variables.

Flow Sensor

Electrode Material : Hastelloy C


Lining Material : Suitable for potable water (Drinking Water) with certification attached
Sensor Housing Protection Rating : IP68/NEMA 6P Enclosure (Sensor can be buried and fully
Submersible)

Indicating Transmitter

Enclosure Rating: IP68, should be stainless Steel Top Housing Material and not Epoxy Painted
Display: Forward Reverse Flow R and Net Total, Time, Date, Status Indication Alarm Fault
Unit : Volume Cubic Meter (m3)
Flow rate (m3/hour)
Output : 2 pulse (Programmable as pulse volume, Forward Reverse flow, Net, Total)
Totalizer Display : Should have 3 Totalizer display can be configured to Forward, Reverse and Bi-
directional Net Flow
Power Supply: Replaceable Internal Battery Packed with Six (6) Years minimum of Maintenance
free battery and it should be Site Replaceable Batteries.

Transmitter should have a Built-in Data logger and can be upgraded for Remote Monitoring by
adding an Upgrade GSM Module Unit Data Logger for REMOTE GSM/GPRS.

Performance

Accuracy : Standard +/-0.2% of Flow Rate +/- 2mm/sec Velocity


Process Media Temperature : -4 to 140 Deg. F
Designed with No Moving Parts

The Magnetic Flowmeter Sensor Should be Submersible and Buriable type considering the unit will
be installed in a remote site soil might burry the sensor during rainy season

Bidder Should attached the following:

Manufacturers ISO Standard Certificate on Quality


Manufacturers ISO Certificate Occupational Health & Safety Management
Manufacturer ISO Certificate Environmental Management
Manufacturer Model offered with OIML R49 Certificate Approval
Certificate of authorized service technician

Additional Scope

Warranty Period : Minimum of one year


Must submit Warranty certificate
Must submit original catalogue/brochures and shop drawings
Database of all flowmeters
Installation, Supervision, Start-up and Commissioning of the Flowmeters
Operation and Maintenance Training for the Use of Flowmeters
All expenses must be shouldered by the winning bidder

Prepared by: Checked & Reviewed by: Recommending Approval:

RALPH LOUIE R. CAGASAN, CE RIYNRICK S. DEDUMO, CE NAPOLEON P. PAQUEO, CE


Waterworks Supervisor Assist. Mun. Engineer Municipal Engineer
Approved by:

EDDIE P. GOKIANGKEE
Municipal Mayor

You might also like