RE-CHANNELING OF WATER FLOW

BACKHOE ON BARGE

OUTPUT = 20 - 30 cu.m./hr

30 x 8 = 240 cu.m.

30 cu.m. x 8 hr = 240 cu.m.


hr day day

240 cu.m. x 10 days = 2400 cu.m.


day

VOL = L x W x H
2400 = L x 12.00 m x 1.00 m
L = 2400
12m
L = 200 Linear meters

NOTE: BACKHOE FUEL CONSUMPTION = 80 LITERS/ DAY

80 LITER/DAY x 10 DAYS = 800 LITERS

PREPARED BY:

Engr. JOSE F. FERNANDEZ JR.


ENGINEERING ASSISTANT