You are on page 1of 1

NOTE :-

HD HB HA 1. FOR GENERAL NOTES REFER DRG. NO. 000M/WD/ST/001


GA GB GC GD HC
18000 18000
2. ALL DIMENSIONS ARE IN MILLIMETERS.
1987 6000 6000 6000 6000 6000 6000 1987
3. REINFORCEMENT SHALL BE INSPECTED AND APPROVED
BY THE CONSULTING ENGINEERS BEFORE CONCRETING.
1988 7109
2200 2200 2200 2200 2200 4. MINIMUM LAP AND ANCHORAGE LENGTH IN REINFORCEMENT
2200 2200 2200
1500 988 1212 988 1212 TO BE 52 x SMALLER BAR DIAMETER.
F5,C1 1100 1100 F5,C1 1100 1100 1100 1100 1213 987 F5,C1 1100 1100 1200 1000 1500 1500
F5,C1 F5,C1 F5,C1 F5,C1 F5,C1 750 750 F7,C4 F7,C5
737 763 982 518
5. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH

1100

1100

1100

1100
988

988

988

988
750 750

750

750 750

750 750
ALL RELEVANT STRUCTURAL,ARCHITECTURAL,SERVICE&

2200

2200

2200

2200
1500

1500

1500

1500
SPECIFICATION.

2200

2200

2200

2200
G1 H1

750
1100

1100

1100

1100
1212

1212

1212

1212
750 750 6. CONCRETE GRADE - C30.
F7,C2 F7,C2
3000 2500

3000
1138 1362 2200 2500 1500
1500 F5,C1 F5,C1 1750 1750
875 875 F6,C5 1129 621 7. COVER TO ALL REINFORCEMENT
737 763 1488 1262 F3,C1 F4,C1 F4,C1 1262 1488 F3,C1 F4,C1 F6,C4
2500 1100 1100 1363 1137 1362 1138

1375

1375
2750

1250

1250

1250

1250
1212
1212
2750 BELOW GROUND - 50mm

837

837
750

750
COLUMN - 25mm

2200

2200
2500

2750

2500

2500

2750

2500
1500

1500

1750

1750
G2 750 H2 BEAM - 25mm

750
SLAB - 20mm

913

913
988

988
1250

1250

1250

1250
1375

1375
2500 1100 1100

F7,C2 F4,C1 C7 1138 1362

C8
750 750
F7,C2
9000
3000

3000
9000
1138 1362 2200 2200 2500 2500 1500 1750
F5,C1 F5,C1
1488 1262 F3,C1 F4,C1 1269 1481 F3,C1 F6,C5 1142 608
2500 F4,C1 1100 1100 1363 1137 1362 1138

1375

1375
1250

1250

1250

1250
1212

1212
2750 2750

874
2200

2200
2500

2750

2500

2500

2750

1750
G3 H3

2500

876
988

988
1250

1250

1250

1250
1375
1375
2500
1138 1362 F4,C1
2200 1100 1100
F4,C1 2200 2200

3000
3000

1100 1100 1750


2200 F5,C3 1100 1100
F5,C3 F6,C5 1142 608

1500

1499
1083 1117

1375
1372

1375

1377

1138
1105
1100
1060

874
791 709

2200
2200
3000

2200

2750

3000

2750
2750

2750

1750
2200
1500

G4 H4

876
1062
1095
1100
1140

1373

1375
1378

1375

1499
1500
492 1008 F7,C4 F5,C4
F1,C3 F3,C3 F3,C3 F1,C3

3024
1100 1100
3005

1500 1375 1375 F3,C3


F5,C4 1377 1373 F3,C3 1375 1375 2200 1337 1376 1500 1500
1500 1500 2750
2750 3000 2750 2750 3000

76

10
°

2200 2200 2200 2200 2200 2200 2200 2200 2200 2200
1100 1100 1100 1100 1100 1100 1750
2774

2776
1100 1100 1100 1100 F5,C5 1100 1100 F5,C5 1100 1100 1100 1100 F5,C5 1100 1100 F5,C5 1100 1100
1500 F5,C5 F5,C5 F5,C5 F5,C5 F5,C5 F5,C5 1142 608 F6,C5
F7,C5 900 600
1137

1135

1137

1137

1136

1136

1136

1136

1136

1136

915
712 788

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

1750
1500

835
1063

1063

1063
1065

1064

1064

1064

1064

1064
1064
LAYOUT OF FOUNDATIONS & COLUMNS RESTAURANT BUILDING C7,C8
(FOOTING TO GROUND FLOOR)

LEGEND
COLUMN TYPE COLUMN SIZE
C1 400x225
C2 225x225
C3,C4 300x300
C5 ∅300

SCHEDULE OF FOOTINGS
DETAIL OF COLUMN REINFORCEMENT
TYPE LENGTH WIDTH THICKNESS REINFORCEMENT
L W T1 T2 RF1 RF2 T1 & T2 (TOP NET)
10 10
10 10 F1 3000 3000 550 650 T16-150 T16-150 T10-200 B/W
F2 2900 2900 550 650 T16-150 T16-150 T10-200 B/W
UPPER GROUND TO

03 03 04 04
01 01a 01 02 02 F3 2750 2750 500 600 T16-150 T16-150 T10-200 B/W
300

300
225

225

F4 2500 2500 500 500 T16-150 T16-150 T10-200 B/W


ROOF

01 01a 01 02 02 03 03 04 04
F5 2200 2200 425 425 T12-125 T12-125 -
F6 1750 1750 400 400 T12-125 T12-125 -
400 225 300 300
F7 1500 1500 350 350 T12-150 T12-150 -
F8 1250 1250 300 300 T12-150 T12-150 -

MAIN BARS 04 T20 - 01 - VERTICAL BARS 04 T20 - 02 - VERTICAL BARS 04 T25 - 03 - VERTICAL BARS 04 T20 - 04 - VERTICAL BARS
02 T16 - 01a - VERTICAL BARS
E.G.L.
LINKS 1 - SET T8-10-150 - STIRRUPS 1 - SET T8-10-150 - STIRRUPS 1 - SET T8-10-150 - STIRRUPS 1 - SET T8-10-150 - STIRRUPS

REFER COLUMN DETAIL


FOR COLUMN R/F.

D
10 10 RF1
10 10
RF2
UPPER GROUND FLOOR

10
LOWER GROUND TO

T2
03 03 04 04
T1
01 01a 01 02 02
05
1:3:6 SCREED
300

300

Ø300 05
225

225

CONC.
05 WxL
50

05 WELL COMPACTED
01 01a 01 02 02 03 03 04 04 SOIL FILL
05 05

400 225 300 300


SECTION X-X
(TYPICAL SECTION)

MAIN BARS 04 T20 - 01 - VERTICAL BARS 04 T20 - 02 - VERTICAL BARS 04 T25 - 03 - VERTICAL BARS 04 T20 - 04 - VERTICAL BARS 06 T20 - 05 - VERTICAL BARS
02 T16 - 01a - VERTICAL BARS
SOIL
LINKS 1 - SET T8-10-150 - STIRRUPS 1 - SET T8-10-150 - STIRRUPS 1 - SET T8-10-150 - STIRRUPS 1 - SET T8-10-150 - STIRRUPS 1 - SET T8-10-150 - STIRRUPS
E.G.L. DATE REVISION REV.
DESIGN & BUILD CONTRACTOR
REFER COLUMN DETAIL
RF1
FOR COLUMN R/F.
10 10
10 10 RF1 600

D
LOWER GROUND FLOOR

10 RF2 BED ROCK 200, Nawala Road, Narahenpita


03 03 04 04 FOUNDATION BOTTOM Colombo 05, Sri Lanka.
01 01a 01 02 02 LEVEL Tel :2808835 to 2808844 Fax :2808846 & 2808847

T2
05
FOOTING TO

T1
X X Email : maga@maga.lk
300

300

RF2

05
225

225

Ø300
L

05
05 PROJECT
ROCK ANCHORS

600
01 01a 01 02 02 03 03 04 04
05 05 T20 @ 600C/C BROTH WAYS
T20 @ 600C/C PROPOSED TECH - CITY PROJECT
400 225 300 300
WxL AT WALAHANDUWA
GALLE.
TYPICAL ROCK ANCHOR DETAIL ROCK ANCHORS
MAIN BARS 04 T20 - 01 - VERTICAL BARS 04 T20 - 02 - VERTICAL BARS
04 T25 - 03 - VERTICAL BARS 04 T20 - 04 - VERTICAL BARS 06 T20 - 05 - VERTICAL BARS TITLE
02 T16 - 01a - VERTICAL BARS W NOTE:- FOUNDATION & COLUMN LAYOUT
LINKS 1 - SET T8-10-150 - STIRRUPS 1 - SET T8-10-150 - STIRRUPS
1 - SET T8-10-150 - STIRRUPS 1 - SET T8-10-150 - STIRRUPS 1 - SET T8-10-150 - STIRRUPS PLAN IF BED ROCK IS ENCOUNTERED IN ANY FOUNDATION LOCATION, (FOOTING TO GROUND FLOOR)
THE CONDITION OF ROCK SHOULD BE INFORMED TO STRUCTURAL
(TYPICAL COLUMN FOOTING) ENGINEER.FOUNDATION SIZES AND ROCK ANCHORS WILL BE RESTAURANT BUILDING - C7,C8 BLOCK
DETERMINED ACCORDING TO THE ROCK CONDITION
TYPE OF C1 DRAWN M.D.D.C DRAWING NO.
C2 C3 C4 C5 AND THE COLUMN REACTION.
M. S. P.
COLUMN DESIGN QS / TD / 2021 / 138 - ST 400
L.G.S.J.E DATE SCALE REVISION
CHECKED
21.08.2021 1:125