You are on page 1of 1

200

A B C 50000
D E
12000 6000 6000 6000 6000 14000

200
6000 900

2000
S.S ANCHOR
FASTENER
SPANDRIL GLASS 10 X 100
RAMP SLOPE RATIO-1:10
30M

6000
PANEL ATTACHMENT
12000

TO ARDS BASEMENT-1
-3M
M.S HOT DRIP BRACKETS
75 X 75 X 75MM

14
1
ENTRY

42
ALUMINUM SECTION 50 X 100
0M TRANSOM LINE
FIRE TRUCK MOVEMENT

6MM TOUGHENED

6000
1 F
500 160
1 REFLECTIVE GLASS
25742
11500 VERTICAL FIXING DETAIL

230
1900
D7 D6
6000

8000
2400 5591

2488
2890
D14 D15 D16 D17 12 11
BMS CONTROL
1758 13 10
ROOM

1500
D18

4465
14 9

ST A U ROOM 15 8

16 7

2 2
D8 1680 1730 D5

DETAIL A
17 6

911

7000

RD
6 D1 18 5

2212
19 4 2380
1200

VISION GLASS

7803
ELV

1385

2080
20 3

2000

2000

HT YA
1000
D1 21 2 FIRE ESCAPE LIFT S AFT S AFT
5632 D10 1200

6398
22 1
STAIRCASE
1

7 1800
2400
+0.91M D9 3541

4
750
6000

1200
1750

D13 D12 D11 TOILETS


D10
ST D11 5000

15552
8

SCALE-1:5
8080

9635 1900
1317

700

3 3
STORA E FOR DA RAMP
OFFICIAL FILES RAMP SLOP
RATIO-1:12
4317
50000

500

0
9485

5099
2500

919

2623
995
1171

919 MANA ER S
8090

2230

OFFICE
18600

1300

ROAD
D12
911

3982 1200

1245
D13

700
RETAIL SPACE
D1

NOTES:

1900
1200

FIRE FIRE ESCAPE


4475

S AFT 1200 STAIRCASE ENTR

4 4

3919
D15

5164
GLASS CURTAIN WALLS ARE LIGHTWEIGHT
1200

1200

D14
D16 +0.9M

700
ALUMINIUM-FRAMED FACADES HOUSING
1800

1800

1800

6160

1200
D4

2512
D17 D18 D19 D20 D21 D22 STORA E
7460

700 700

GLASS OR METAL PANELS. THESE GLAZING


5087
1520

FEMALE MALE
2299

TRIAL ROOMS TRIAL ROOMS BILLIN 5472

900
COUNTER D2
1855
4773

SYSTEMS DON'T SUPPORT THE WEIGHT OF A


1667

8675

RD
ENTR FOR
1030
2100

1100

6133
OFFICE

DG Y A
PEOPLE

5 5
1317

ROOF OR A FLOOR. EACH GLAZING SYSTEM


4435

4320
900

D3
1855
2100

1100
1970

2235
REQUIRES CAREFUL INTEGRATION WITH OTHER
9160

20942 SPANDRIL GLASS ADJACENT STRUCTURAL ELEMENTS SUCH AS


9
34
10450

10
WALL CLADDINGS, ROOFS AND WALL DETAILS.

6000
EXIT
SLAB BELOW
WHEN GLASS IS USED AS THE CURTAIN WALL,

2000
40000
AN ADVANTAGE IS THAT NATURAL LIGHT CAN
PENETRATE DEEPER WITHIN THE BUILDING. THE
A B C D E
CURTAIN WALL FACADE DOES NOT CARRY
ANY STRUCTURAL LOAD FROM THE BUILDING
OTHER THAN ITS OWN DEAD WEIGHT.
KE PLAN DETAILED ELEVATION
FABRICATION AND INSTALLATION METHODS
1 2 CLASSIFY GLASS CURTAIN WALLS INTO TWO
SCALE-1:200
MULLION DETAIL SCALE-1:20
GENERAL CATEGORIES: STICK SYSTEMS AND
UNITIZED OR MODULAR SYSTEMS. STICK
1800 1800 SYSTEMS UTILIZE A FRAME MADE UP OF
MILLIONS GLASS OR OPAQUE PANELS. THESE
PANELS ARE DESIGNED AND INSTALLED AS A
UNITIZED SYSTEM.

PLAN UNITIZED SYSTEMS ARE COMPOSED OF LARGE


UNITS THAT ARE ASSEMBLED AND GLAZED IN
3 THE FACTORY. THE INSTALLER OR BUILDER THEN
SCALE-1:20 RECEIVES AND ERECTS THE GLASS SECTION ON
THE BUILDING SITE. THE STANDARD SIZE IS
AROUND ONE STOREY TALL AND ONE MODULE
WIDE; HOWEVER EACH SECTION MIGHT
INCORPORATE MORE THAN ONE MODULE.

DRESS CAP

CAP SCREW
ALUMINUM MULLION

SCREW CHASE
GLAZING CAVITY
ALUMINUM TRANSON STUDENT NAME:
GLAZING PANE
ISHIKA SHRIVASTAVA
USN: SEM: SEC:
IRW18AT001 6 B
DOUBLE GLAZING
PLATE TITLE:

GLASS CURTAIN WALLS


INTERIOR GASKET
SUBJECT CODE: PLATE NO. SHEET NO.
18ARC6.2 2 1
SUBJECT NAME:
EPDM THERMAL STRIP
MATERIALS AND METHODS IN
BUILDING CONSTRUCTION VI
4 MULLION DETAIL 2 MULLION DETAIL
MULLION DETAIL ISOMETRIC VIE
INTERNAL MARKING:

MULLION DETAIL 1 2 LATE


STRUCTURAL SILICON LA IN S STEM 6 7
5 SCALE-1:5 SCALE-1:5 _ _ _
SCALE-1:2 RV COLLEGE OF ARCHITECTURE

You might also like