User-friendly, Earth-friendly
COMPRESSOR
HEAT EXCHANGER
- Shell structure with evaporator and separated condenser (Shell and tube structure)
- High-efficiency heat transfer tube (Improved heat exchange rate, reduced compressor load, and
reduced power consumption)
- SUBCOOLING SYSTEM
- Improved refrigerating efficiency with - 77dB or lower (12% lower than constant-speed
DDC-type PID precision control centrifugal chiller)
- Modbus protocol and Ethernet communication - Lower volume (33% lower than same-size model)
- Color TFT touch screen - Lightweight (48% lower than same-size model)
Economic Conditions
Century
2
Oil - Free Inverter Centrifugal Chiller
IPLV 6.3
Features (0.56kW/RT)
1.2
1
kW/RT
Screw
0.8
0.6
TR-A80HA1
0.4
0.2
20 40 60 80 100
Part Load(%)
3
Oil - Free Inverter Centrifugal Chiller
Model Nomenclature
TR W 150 HA(B) 1
VER. No.
Refrigerant: R-134a, quantity of compressors (A: 1, B: 2, C: 3)
Refrigerating Capacity : 90~450 USRT (water-cooled type)
60~160 USRT (air cooled type)
Cooling Type : W : Water-cooled Type
A : Air-cooled Type
Century
4
Oil - Free Inverter Centrifugal Chiller
Features of compressor
Sakura centrifugal chiller is optimally designed with Turbocor’ s oil-free system. The magnetic
bearing technology is automatically controlled with a 2-step turbo compression and a feedback of
100,000 times/second positional information for high reliability.
Cross section of the Danfoss Turbocor compressor equipped with oil-free 2-step turbo compressor shaft and magnetic bearing of Turbocor rotating
magnetic bearing technology for Sakura centrifugal chiller above the rotor assembly magnetic bearing for Sakura centrifugal chiller
Sakura oil-free inverter centrifugal chiller features a compact size, low noise,
and high efficiency.
This oil-free inverter centrifugal chiller consists of shell and tube evaporator and condenser, a 2-
stage compressor, an optimally programmed controller, a refrigerant level sensor for optimum control,
an electronic expansion valve, and several safety devices. The oil-free inverter centrifugal chiller
possesses a high-efficiency optimal system achieved through the adoption of Danfoss Turbocor’ s
oil-free system.
In addition, the automatic and optimally programmed high-performance controller supports a perfect
remote control system with Modbus and RS-232 communications. Sakura Turbocor chiller pro-
vides outstanding performance under part load and minimized operation cost with high reliability.
The graph above compares the total cost of the screw chiller and the oil-free chiller for 2 years.
5
Oil - Free Inverter Centrifugal Chiller
High-performance heat transfer tube, “THERMOEXCEL,” is used for a more effective heat exchange rate
between an evaporator and a condenser.
Using this product, evaporation temperature is increased and condensation temperature is decreased, making
the compression rate small and the load of the compressor much less, thus reducing power consumption.
1. Heat transfer tube“THERMOEXCEL - EKW” for evaporator 2. Heat transfer tube“THERMOEXCEL - CKW” for condenser
For the heat transfer tube of the evaporator, a tun- For the heat transfer tube of the condenser, it is
nel is made in a circumferential direction under the processed in a micro-fin shape with a sharp
surface to promote boiling and increase the air point for easy condensation and dripping of re-
bubble production point. In the tunnel, the refriger- frigerant. In addition, grooves and projects are
ant evaporates quickly to boil continu- processed double to improve the heat transfer
ously and completely. performance. This structure offers better heat
In addition, grooves and projects are processed transfer performance than existing single-
double to improve heat transfer performance. This grooved and project-processed heat transfer
structure offers better heat transfer performance tubes.
than existing single-grooved and project-
processed heat transfer tubes.
CONTROL
- Touch Screen
·Easy control and operation with English
language interface and visualization
·One screen shows full operation state
·Convenient alarm history management
Century
6
OilOil - FreeInverter
- Free InverterCentrifugal
Centrifugal Chiller
Chiller
usRT 90 90 110 120 125 150 180 180 220 250 260 300 340 380 380 450
Cooling Capacity
kW 316.5 316.5 386.8 422.0 439.5 527.4 632.9 632.9 773.6 879.1 914.2 1,054.9 1195.5 1336.2 1336.2 1582.3
Input kW 61 57 80 77 88 93 124 116 160 161 181 187 249 246 265 281
kW/RT 0.379 0.354 0.408 0.364 0.394 0.352 0.385 0.361 0.408 0.359 0.393 0.351 0.410 0.361 0.389 0.349
Efficiency(NPLV)
COP 9.271 9.933 8.614 9.663 8.925 10.000 9.128 9.728 8.628 9.788 8.944 10.026 8.576 9.744 9.043 10.069
Flow Rate m3/h 55 55 67 73 76 91 109 109 134 152 158 182 206 230 227 273
Chilled Pressure Drop mAq 4.9 4.9 5.2 5.6 4.5 6.4 8.5 8.5 3.1 4.3 3.4 4.5 4.3 5.6 4.5 6.0
Water Connection Size A 100 100 125 125 150 150 200 200
No. of Passes - 3 3 3 3 2 2 2 2
Temperature ℃ Inlet 32 / Outlet 37
Flow Rate m3/h 66 66 82 88 93 109 132 131 164 183 193 218 253 278 281 327
Cooling
Pressure Drop mAq 6.5 6.5 6.7 7.0 5.6 7.7 9.2 9.2 4.2 5.5 4.6 5.8 6.2 7.6 6.6 8.1
Water
Connection Size A 100 100 125 125 150 150 200 200
No. of Passes - 3 3 3 3 2 2 2 2
Length(L) mm 2,900 3,000 3,100 3,600 3,720 3,820 4,669 4,669
Dimen-
sion
Width(W) mm 1,100 1,150 1,200 1,400 1,410 1,485 1,900 2,000
Height(H) mm 1,890 1,990 2,040 2,280 2,400 2,460 2,000 2,086
Shipping Weight Ton 2.4 2.6 3.0 3.5 3.9 4.1 5.4 5.6
Operating Weight Ton 2.9 3.3 3.7 4.2 4.8 5.0 6.7 6.9
Main Power - 3PH, 380/440V, 50/60Hz
7
Oil - Free Inverter Centrifugal Chiller
Chilled water
Chilled water Inlet Outlet
TR-W380 ~ 450HC1
Cooling Water
Outlet
Cooling Water
Inlet
Century
8
Oil - Free Inverter Centrifugal Chiller
Outdoor Temperature ℃ 35
Con-
denser Airflow CMM 1,840 1,840 3,680 3,680 3,680 3,680
Chilled water
Outlet
Chilled water
Inlet
9
Oil - Free Inverter Centrifugal Chiller
Century
10
SAKURA CORPORATION