Compressor

Product Specification

Model HY90Y a
Brand Huayi
Cooling capacity 95Kcal/Hr, 133.3Kcal/Hr,
150.5Kcal/Hr, 228Kcal/Hr,
327Kcal/Hr,
404Kcal/Hr, 860Kcal/Hr 1292Kcal/Hr
Method Fan Cooling
Power Input 98 W, 141 W, 159 W, 204 W, 293 W,
188 W, 455 W
Displacement 11.3 Cm3

Voltage Range 160-260 V


Voltage 220V
Frequency 50/60Hz
Refrigerant R134a

Application Deep freezer, Water cooler, Display


cabinet, Visi cooler
Motor Type RSIR, RSCR, CSR, CSIR

DN 50 DRIERS
Features
DN
Refrigerants R 22, R 134a and R 404A, R 507 etc.
Compatible with CFC and refrigerant blends containing R 124a, R 125, R 134a,
R143a, R 152a, R 218, R 23 and R 32.
Solid core consisting of: 3Å molecular sieves and activated aluminium oxide for
acid adsorption.
DN and DU filter driers
Removes moisture in the refrigeration system quickly and effectively
Optimized, uniform grain size in the solid core
Insignificant pressure drop
Can be installed in any position provided the arrow is in flow direction.
Effective filtering down to 20 µm
Solid core High vibration resistance eliminates the risk of dust formation from
desiccant wear.
Robust solid core withstands pressure surge and vibration without releasing dust
into the refrigeration system.
DN/DU 032s, DN/DU 032.5s and DN/DU 033s specially prepared for use in units
with capillary tube expansion.
Helium leak detection All DN and DU filter driers are leak tested before being
painted.
Surface finish, powder coating High corrosion resistance. Can be used in all
environments - from plant rooms to ships’ refrigeration systems.
FAN MOTOR
ebm-papst
M4Q045-CA03-A4
AC Motors

Product Technical Specifications


Type Shaded Pole Motor
Motor Current (A) 0.25
Motor Voltage (V) 230
Maximum Output Power 10W
Operating Speed (r/min) 1550
Configuration Motor Only
Motor Shape Square Body
Number of Shafts 1
Minimum Operating -30
Temperature (°C)
Maximum Operating 40
Temperature (°C)
Product Length (mm) 83
Product Height (mm) 89.5
Mounting Foot Mount

Condenser
A condenser is designed to transfer heat from a working fluid (e.g. water in a steam
power plant) to a secondary fluid or the surrounding air. The condenser relies on
the efficient heat transfer that occurs during phase changes, in this case during
the condensation of a vapor into a liquid. The vapor typically enters the condenser
at a temperature above that of the secondary fluid. As the vapor cools, it reaches
the saturation temperature, condenses into liquid and releases large quantities
of latent heat. As this process occurs along the condenser, the quantity of vapor
decreases and the quantity of liquid increases; at the outlet of the condenser, only
liquid remains. Some condenser designs contain an additional length to subcool
this condensed liquid below the saturation temperature
Countless variations exist in condenser design, with design variables including the
working fluid, the secondary fluid, the geometry and the material. Common
secondary fluids include water, air, refrigerants, or phase-change materials.
Condensers have two significant design advantages over other cooling
technologies:

 Heat transfer by latent heat is much more efficient than heat transfer
by sensible heat only
 The temperature of the working fluid stays relatively constant during
condensation, which maximizes the temperature difference between the
working and secondary fluid.

DN 50 DRIERS
Features
 Solid core consisting of: 3Å molecular sieves and activated aluminum oxide
for acid adsorption.
 Removes moisture in the refrigeration system quickly and effectively.
 Optimized, uniform grain size in the solid core.
 Insignificant pressure drop.
 Can be installed in any position provided the arrow is in flow direction.
 Effective filtering down to 20 µm
 Solid core High vibration resistance eliminates the risk of dust formation
from desiccant wear.
 Robust solid core withstands pressure surge and vibration without releasing
dust into the refrigeration system.

DIGITAL thermostat
Features:
 A mini temperature controller.
 Large and clear LED display for better readability
 Wide temperature measuring range
 Heating and cooling control
 Temperature calibration
 Delay protection function
 All parameters reset to default settings after short circuit
Working voltage DC 9-72V/AC90-250V ± 10%, 50/60 HZ
Rated current 10 A
Power consumption ≤3 W
Measurement range -50~110 °C
Measurement precision 0.1 °C
Measurement error ±0.3 °C
Control precision 1°C
Working temperature -20~70 °C
Output load Normally open 10 A / AC 220 V
Shipment Weight 0.08 kg
Shipment Dimensions 8 × 8 × 4 cm
R134a GAS
A refrigerant is a fluid that is used in air conditioners and refrigerators, to take heat
from the contents of a refrigerator or the room (in the case of ACs) and throw the
heat out in the atmosphere. A refrigerant undergoes phase changes from a liquid to
gas (on absorbing heat) and back to liquid (when a compressor compresses it). The
choice of ideal refrigerant is made based on its favorable thermodynamic
properties, non-corrosive nature, and safety (non-toxic and non-flammable).
Although many fluids can be used to act as a refrigerant, but in 20th century, CFCs
became the most popular refrigerants.
 R134a is no-toxic, non-flammable and non-corrosive.
 R134a has a high heat of vaporization
 The universally accepted cylinder color code for R134a refrigerant is light
blue.
 It has a moderate density in liquid form.
 R134a has zero Ozone layer depleting properties and hence became popular
as an ideal replacement for dichlorodifluoromethane (R-12), which was
known to have an adverse impact on the Ozone layer.

COPPER PIPE
Its use to connect each component to the compressor in series to for a system.
Because of its following advantages,
 Cost-effective fabrication and assembly.
 Smaller size, less weight and lower material costs.
 Higher heat transfer coefficients.
 Well-suited for new refrigerants.
 Uses less refrigerant.
 Overall reduction in system cost