You are on page 1of 2

VERSATILE MULTI-LIQUID ULTRASONIC

FLOWMETERS With Mating Flow Transducers


Model FD-7000
$
5150
Complete with Flowmeter,
Mating Flow Transducers,
and Operator’s Manual

Supplied with Black


Plastic Cover

Up to now, Doppler ultrasonic A backlit, 2 line by 20 character,


flowmeters have required significant alphanumeric LCD offers simultaneous
quantities of suspended particles or gas flowrate and totalizer displays.
U Non-Invasive Design, bubbles to reflect sound signals. Now, The FD-7000 is designed for ease of
Easy to Install, No with the Model FD-7000 Ultrasonic use in the field. Only a few simple
System Downtime Flowmeter, this is no longer required. keypad entries are required to configure
When the FD-7000 is used to measure the flowmeter for any given pipe and
U Powered by the flow of liquids containing suspended flow conditions.
Rechargeable Internal solids or bubbles, the transducers are
mounted on a straight run of pipe in the The encapsulated, submersible design
Battery or AC Line Power same manner as other ultrasonic of the transducer sensor head allows it
to be easily mounted to the pipe surface
U Operates with Clean meters. In applications where
with the coupling compound and elastic
insufficient “reflectors” exist (a condition
Liquids, Emulsions indicated by a low reading on the bands that are supplied with the unit.
and Slurries FD-7000’s Flow Analyzer bar graph), A 6 m (20') retractable cable for
connection to the transmitter/indicator
U Digital Flowrate Indicator the transducers are relocated to a point
in the piping where non-symmetrical unit is supplied as as integral part of the
Plus Eight- Digit Totalizer hydraulic turbulence will be present – sensor. The FD-7000 sensor is utilized
on pipes that range in internal diameter
U 4-20 mA Output Standard ideally just downstream of a 90° elbow.
from 25 to 3048 mm (1 to 120").
The FD-7000’s unique digital filtering
U Easy-to-Use system and signal recognition circuitry Flowrates can be measured in smaller
Data Entry Keypad transforms the reflections from this non- pipes from 6 to 25 mm (1⁄4 to 1") in
symmetrical, and not necessarily linear, diameter with use of the small pipe
U NEMA-4X ABS turbulence into a useable and linear sensor, model FD-7000-S1.
Waterproof Enclosure data format.
E-5
ULTRASONIC FLOWMETERS
GAL 45263 Totalizer
FLOW GPM 1,250 Flow Rate
5, 10, 20 FPS

. LL
1 to 120" I.D FU ALE 7 8 9
SC
FPS, GPM, MGD

Totalizer Factor L.
VOLSE TS
0 to 100,000 U U NI 4 5 6
P
Adj.
E
Calibration L M P 1 2 3
CA DA

S T SET 0 • N
RUNT
Entry Mode/
TE RE E
Run Mode

SPECIFICATIONS Power Requirements: 115 Vac ±10%, 50/60 Hz,


FD-7000 20 VA max. (standard); 230 Vac 50/60 Hz (optional).
Internal gel cell battery provides 8 hrs.
System Accuracy: ±2% of F.S.
of continuous operation
Velocity Range: 0.15 to 6.2
Liquid Requirements: Full-pipe,
meters/second (0.5 to 20 feet/second)
low-viscosity (water-like) liquid
Measuring Units: FPS, GPM, MGD
Transmitter/Indicator Operating T
Linearity: ±0.2% of F.S. emperature: -30 to 70°C (-22 to 158°F)
Repeatability: 0.4% of F.S. Sensor Operating Temperature:
Flow Rate Display: 6-digit LCD -40 to 121°C (-40 to 250°F)
Totalizer Display: Dimensions: 432 L x 279 W x 203 mm H
6-digit LCD (resettable) (17 x 11 x 8")
Outputs: 4-20 mA into 600 Ohms Weight: 10 kg (22 lb)
max., isolated Enclosure: NEMA-4X (IP65)

HIGHLIGHTED MODELS STOCKED FOR FAST DELIVERY!


To Order (Specify Model Number)
Model No. Price Description
FD-7000 $5150 Ultrasonic Flowmeter
*For metric add “-M” to model number; no extra charge. For Line Sizes
For 230 Vac version add “-230” to model number. 25 to 1524 mm
Comes complete with operator’s manual, 2 transducers, couplant, and battery. (1" to 60")
Ordering Example: FD-7000, ultrasonic flowmeter, $5150
Accessory Required
Model No. Price Description Pipe
Mounting
FD-7000-STD $840 Replacement sensor for Configuration
25 to 1524 mm (1" to 60") pipes
FD-7000-S1 990 Sensors for 1⁄4" to 1" pipe
FD-7000-HT 1240 High temperature sensor for 25 to 1524 mm
(1" to 60") pipe, 204°C (400°F)
FD-7000-BATT 95 Replacement gel cell battery
FD-7000-Charger 65 Replacement charging cord (USA) NON-PENETRATING-
FD-7000-EXT 275 Two conductors, 20 AWG, EASY INSTALLATION
unshielded extension cable, 6 m (20')