You are on page 1of 7

SITRANS F flowmeters

SITRANS F M
Magnetic water meter MAG 8000W
• Optimal battery power control for reliable information on real
■ Overview battery consumption to reduce site visits.
• Integrated data logger for monitoring of water consumption
and operation conditions. Selectable alarm level for too high
or too low consumption.
• Easy to integrate in a system. MAG 8000W has 2 integrated
pulse outputs and an open “add-on” communication platform
to support existing and future communication platforms. Indi-
vidual configuration of free scalable pulse outputs and net
pulse (based on bi-directional flow calculation).
• Easy set up and documentation of settings. PC Flow Tool Con-
figuration Software for easy set up and meter service. Easy
data download enables same setting of all MAG 8000W
meters installed. Password protection against unauthorized
use of parameters.
4 • No corrosion problems. The build-in standard IrDA interface
ensures problem-free on-site communication. The special
meter coating optimises the resistance against aggressive
media.
• Complies with approvals and standards. WRc drinking water
MAG 8000W battery powered electromagnetic water meter is approval.
designed according to the global water meter standard Additional benefits for potable water distribution networks:
OIML R49 and the European CEN EN 14154. The design fulfils
special customer demands to water applications within abstrac- • Designed for low flow leakage detection. The special sensor
tion, distribution network, revenue metering and irrigation. All design with one internal cone down ensures optimal low flow
functionalities integrated in one meter to optimize water supply measurement with minimal pressure drop and subsequently
and use of highly scanty resources. higher energy consumption.
• Replacing two existing meters by one reduces installation and
With the MAG 8000W product platform focus has been put on maintenance costs. MAG 8000W performances can replace a
the following basic elements; revenue and a distribution meter and makes replacement ob-
• Precision vious when the meters are installed in the same location.
Accurate and reliable measurement for long-term perfor-
mance Additional benefits for potable water revenue metering:
• Information • Protection of custody transfer parameters. MAG 8000W has a
Dedicated information prepared directly from meter site to 4-level data protection to avoid unauthorized use;
minimize the need for additional advanced systems - Software password on parameter and data changing
- Hardware protection of measurement parameters and
• Communication totalizer
Open “add-on” communication platform for connection to ex- - Special enclosure screw for CT sealing
isting systems and future proof for new standards without - Data security information about important parameters
meter replacement
• Long-term accurate measurement for correct billing. No mov-
• Ownership ing parts that can wear and tear over time.
Easy to install with low installation, maintenance and operation
cost • Replacing two existing meters by one reduces installation and
maintenance costs. MAG 8000W performance can replace a
One MAG 8000W, with its comprehensive integrated functional- revenue and a distribution meter and makes replacement ob-
ity and high performance measurement, will in many cases re- vious when the meters are installed in the same location.
place existing district and revenue meters on the same location.
Its easy to install concept and long-term performance take cost Benefits for irrigation:
of ownership as customer service to a new level. • Long-term accurate measurement for correct billing. No mov-
ing parts to wear and tear over time. No stops due to particles
Features like 6 years maintenance-free battery-powered opera- in the medium.
tion and no moving parts provide long-term highly accurate
measurements that make MAG 8000W one of the most convinc- • Optimal meter technology selection for short installation con-
ing selections for stand alone water applications. ditions (in- and outlet conditions). Often practical installation
conditions challenge the demanded inlet and outlet condi-
tions.
■ Benefits
MAG 8000W has been developed for water applications to opti-
mize water supply and correct billing.
Benefits for all applications:
• Flexible power supply makes it easy to install MAG 8000W for
leakage detection. If “no power supply” is present, the internal
or external battery pack ensures operation in typical stand
alone applications for up to 10 years of operation.
• Long-term measurement performance to rely on. Indepen-
dently of power supply MAG 8000W delivers highly accurate
and repeatable measurements of bi-directional flow.
• Build for installation everywhere. The meter enclosure is
IP68/NEMA 6P and designed for underground installation that
can be flooded.

4/90 Siemens FI 01 · 2005


SITRANS F flowmeters
SITRANS F M
Magnetic water meter MAG 8000W
MAG 8000W includes the following functionalities (CS for Cus-
■ Application tomer Specified);
MAG 8000W has been developed as a stand alone water meter • Real time clock and date for optimal data information (CS)
for applications within; • 3 totalizers, 2 individually configurable (CS) on forward, re-
• Abstraction; Collecting water to treatment plans verse and net flow and 1 (CS) (based on totalizer 1) totalizer
• Distribution network; Distribution of water from treatment with on site key reset. Totalizers 1 and 2 (CS) can be changed
plants to customer to an individual starting value. All totalizers have registration of
date and time when reset or changed
• Revenue metering; Measuring the amount of water delivered
for billing purpose • Advanced alarm handling on meter performance and applica-
tion/installation conditions with registration of total hours in
• Irrigation; Measuring the amount of water delivered for billing which the measuring condition has been influenced. The
purpose and monitoring water consumption alarm can be configured (CS) for alarm or call up via pulse
output or communication interface. The alarm log is reset-able
■ Design (CS) with registration of date and time. Alarm handling also in-
cludes individual alarm registrations like
MAG 8000W is designed according to OIML R49 and CEN
EN 14154 water meter standards with focus on minimization of
- Total hours an alarm has been active
- Number of times the alarm has been activated
4
power consumption, easy to install with long-term performance - First time the alarm appears
with dedicated integrated functionality to optimise information - Last time the alarm disappears
on water flow and consumption. MAG 8000W is a combination of
a new transmitter and the MAG 5100 W sensor program with a • Meter status information for quick information on manipulation
special MAG 8000W calibration. of important information and meter operation
• Call up on alarm via pulse output or communication interface
(CS)
• 2 pulse outputs individually configurable (CS) as pulse, alarm
or call up. As pulse output on forward, reverse or net flow cal-
culations with free scalable volume per pulse settings and
pulse length.
• Advanced power management program for optimal battery in-
formation and replacement. It includes battery consumption of
all consuming elements as compensation for the drift in tem-
perature.
• Meter measurement settings with protection of parameters to
ensure correct measurement and revenue billing
• Service information and simulation to ensure correct display of
flow information through the whole signal chain.
• Data logger with 26 records selectable as day, week or month
logging. One log includes consumption on totalizers 1 and 2,
active alarms and influence of mater status parameter for
logged period. Alarm on too high or too low consumption of to-
talizer 1 for the logged period.
• Empty pipe detection (CS) and electrode impedance mea-
surement
• Application identification (CS) and location information
• Fixed or automated adjustment of decimal point (CS)
The display and key improves customer operation and informa- • Special verification mode for fast verification of meter perfor-
tion on site. mance (CS)
Key: By activating the key, the information toggles to the next in- • Automatic data back up each 10 minutes
dex and related information. • Power consumption and number of power ups
Display: The display has been divided into 3 areas. Top area with
symbols for status information. Mid are with actual information. • Password protection of all parameters (CS) and hardware pro-
Bottom area with index number for the information shown. tection of calibration parameters

A Siemens Flow Tool software or communication interface allows


all settings made and that comprehensive information can be PC Flow Tool configuration software includes:
collected from the meter. • Set up meter configuration
• Download and save meter information
■ Function • Print and export of meter information
MAG 8000W includes a wide range of functions and information • Configuration of own individual parameter lists
to optimise water supply and billing. Some data are available via
meter display and key whereas all are accessible via communi- • Additional meter set up in the same project file
cation interface and PC Flow Tool software. All settings are only • Project files can also include related electronic information
configurable via IrDA and Flow Tool software or via communica-
tion interfaces.

Siemens FI 01 · 2005 4/91


SITRANS F flowmeters
SITRANS F M
Magnetic water meter MAG 8000W

■ Technical specifications Temperature


• Ambient -20 ... +60 °C (-4 ... +140 °F)
Sensor
• Storage -30 ... +70 °C (-22 ... +158 °F)
Size and flange DN 50 ... DN 300 (2“ ... 12“) with
EN 1092-1 (DIN 2501), ANSI Enclosure IP68/NEMA 6P rating without
class 150 flanges or AS 4087 cable glands mounted.
Class 14 Cable glands mounted requires
Sylgard® potting kit to remain
Pressure range • DN 50 (2”)... DN 150 (6”) = IP68/NEMA 6P, otherwise
16 bar (232 psi) IP67/NEMA 4 rating
• DN 200 (8”)... DN 300 (12”) =
10 or 16 bar (145 or 232 psi) Meter set-up PC software – Flow Tool, set-up of
parameter and monitoring data,
Media temperature 0 ... 70 °C (32 ... 158 °F) communication through IrDA
interface
Liner Hard rubber/composite elastomer
Approvals WRc approval for potable water
Electrodes AISI 316 Ti (1.4571) (NSF pending)
4 Transmitter Conformity • PED: 97//23EC
Functions See function description • EMC: EN 61000-6-3 and EN
Installation Integral on sensor (compact) 61000-6-2 + DIN EN 61326-1
• EN 14154, OIML R49, ISO 4064
Display and key • Display with 8 digits for informa-
tion, index and icons for status
information
• Key for toggling between dis- MAG 8000W water meter uncertainty
play information To ensure continuous accurate flow measurement, water meters
Measuring function Empty pipe detection must be calibrated. Calibration is conducted at Siemens flow
• Excitation frequency 1/15 Hz for all sizes calibration facilities accredited according to ISO 17025 (ISO
17025 EA) by UKAS and DANAK and traceable to NIST.
• Low flow cut-off 0 ... 9.9% of max. Qn (Qmax) A calibration certificate follows every sensor and calibration data
• Measure filtering [S] 0 ... 1000 (time constant value) are stored in the meter unit.
multiplied by measuring interval =
(I/excitation frequency)
Flow unit Standard:
± %E
• Europe: Volume as m3 and flow 3.0
rate as m3/h v ³ 0.5 m/s (1.5 ft/sec.) Þ E: ±0.5 % of measured value
v < 0.5 m/s Þ E: ±(0.25 / v) % of measured value
• USA: Volume as Gallons and 2.5
v < 1.5 ft/sec. Þ E: ±(0.82 / v) % of measured value
flow rate as GPM
• Australia: Volume as ML and 2.0
flow rate as MLD
Cable entries 2 x M20 (one gland delivered for 1.5
6-8 mm cable size)
Digital output • 2 passive individual galvanic 1.0

isolated open drain MOS out-


puts 0.5
• Maximum load ± 35 V, 50 mA
short circuit protected 0
0.1 0.5 5 10 12
• Shielded cables m/s

• Output A Programmable as pulse volume – 0.3 1.5 15 30 36


forward/reverse – forward/net – ft/sec.
v : Flow velocity
reverse/net with pulse width of E : Meter uncertainty as a percentage of actual flow
10/50/100/500 ms and max. pulse
rate of 50 Hz
• Output B Programmable as pulse volume
(like output A), alarm or call-up
Calibration
Communication Integrated infrared communica-
tion interface, IrDA with Modbus Reference conditions (ISO 9104 and DIN EN 29104)
RTU protocol Media temperature 20 °C ± 5 K (68 °F ± 9 °F)
Power supply • Internal battery pack 3.6 V / Ambient temperature 20 °C ± 5 K (68 °F ± 9 °F)
33 Ah
• External battery pack 3.6 V / Warming-up time 30 min.
66 Ah in IP68/NEMA 6P enclo- Incorporation in pipe section
sure and connections
• Inlet section 10x DN (DN ≤ 1200 (48”))
Meter
• Outlet section 5x DN (DN ≤ 1200 (48”))
Media conductivity > 20 µs/cm
Flow conditions Fully developed flow profile
Accuracy Max. uncertainty of ± 0.5% of rate
in flow range 0.5 ... 10 m/s Installation conditions
(1.5 ... 30 ft/s).
Please refer to “System information MAGFLO electromagnetic
Repeatibility ± 0.1% of actual flow
for v ≥ 0.5 m/s (1.5 ft/s) flowmeters”.

4/92 Siemens FI 01 · 2005


SITRANS F flowmeters
SITRANS F M
Magnetic water meter MAG 8000W
Output configuration
Flow Net total- Pulse output Pulse output net
izer in forward forward
meter dis- Uni-directional Bi-directional
)RUZDUG 5HYHUVH play mode mode
(Bi-direc- Volume [m3] Volume [m3]
tional)
Volume Internal Deliv- Internal Deliv-
[m3] calcula- ered calcula- ered
tion output tion output
0 - 0 0 0

&XW 4 &XW 4
2II 2II

35>V@

3)>+]@
P 3
10 - 10 0 10
4
0D[

0LQ
-2 - 0 -12 0

3:DQGPV P3

Pulse volume: Output A/B configured as volume per pulse, the


output delivers a pulse when the preset volume has passed the 18 - 20 -12+20= 8
selected direction, calculated on forward/reverse or Net for-
P3
ward/reverse flow. The volume per pulse is freely scalable, from
0.0001 to 10,000 meter-unit per pulse. PR = pulse rate and
PF = pulse frequency

Total accounted vol- 18F - 30F 18F


2Q ume [m3]
Forward/reverse
$ODUPRXWSXW 2II
Battery operation time and calculation

2Q The battery operation time depends on the connected battery


pack as well as the operation conditions of the meter. Every 4
$ODUPVWDWXV 2II hours the advanced power management system calculates the
real power consumption and remaining operation capacity.

Alarm: The alarm will follow the internal alarm status. The power consumption calculation includes flow measurement,
meter dialog (communication and display) and pulse output.
The temperature is also measured to control and adjust its influ-
2Q ence on the battery capacity.
&DOOXSRXWSXW 2II The internal battery pack has a nominal capacity of 33 Ah giving
a typical operation time of 6 years in a revenue application. The
nominal capacity of external battery packs is 66 Ah and the op-
eration time is limited to the lifetime of the batteries – typically
&DOOXSUHVHW 10 years. Configuration and operation conditions are shown in
the table.
2Q Scenario - Revenue application
&DOOXSVWDWXV 2II Output A Pulse – 10 Hz
Output B Alarm or call-up
Call up: The “call-up” output is active until manually reset. The Meter dialog 1 hour per month
call-up function is activated when an alarm is activated.
Excitation frequency 1/15 Hz
MAG 8000W has a special net pulse output that include bi-direc-
Country main frequency 50/60 Hz
tional flow calculations. This is special for installation where the
meter is connected to a system with only one input. The example Internal battery pack 50 Hz: 77 months (6.48 years)
shows that over time, the net pulse output indicates the bi-direc- 60 Hz: 86 months (7.16 years)
tional totalized meter calculations. Same principle for forward External battery pack 120 months (10 years)
and reverse flow calculations.
High or low temperature influence the capacity of the battery
and thereby directly influence the total operation time. The
MAG 8000W power management system includes these influ-
ences. The typical operation time of 6 years is based on only
80% battery capacity and an operation time/temperature profile
of 5% @ 0 °C/32 °F, 80% @ 15 °C/59 °F and 15% @ 50 °C/122 °F.

Siemens FI 01 · 2005 4/93


SITRANS F flowmeters
SITRANS F M
Magnetic water meter MAG 8000W

$YDLODEOH&DSDFLW\ The effect from other temperatures can be seen from the figure.
 A variation in temperature from 15 °C to 55 °C (59 to 131 °F) re-
P$
duces the capacity by 17%. (In the table from 15 Ah to 12½ Ah).
&DSDFLW\WR9ROWV$K






          
          

4 7HPSHUDWXUHr& r)

■ Dimensional drawings
   
  

$
'2

/ ',
'1

Nominal DN size A L, lenghts D, diameter


mm (inch) mm (inch)
PN 10 PN 16 DI DO
mm (inch) ANSI Cl. 150 mm (inch) mm (inch)
AS 4087 Cl. 14
mm (inch)
50 (2) 214 (8.43) N/A1) 200 (7.9) 42 (1.65) See flange table
65 (2½) 220 (8.66) N/A1) 200 (7.9) 55 (2.17) See flange table
80 (3) 226 (8.90) N/A1) 200 (7.9) 67 (2.64) See flange table
100 (4) 233 (9.17) N/A1) 250 (9.8) 81 (3.19) See flange table
125 (5) 243 (9.57) N/A1) 250 (9.8) 101 (3.98) See flange table
150 (6) 258 (10.16) N/A1) 300 (11.8) 131 (5.16) See flange table
200 (8) 283 (11.14) 350 (13. 8) 350 (13.8) 169 (6.65) See flange table
250 (10) 310 (12.20) 450 (17.7) 450 (17.7) 212 (8.35) See flange table
300 (12) 336 (13.23) 500 (19.7) 500 (19.7) 265 (10.43) See flange table
1) PN 16 suggested as an option

4/94 Siemens FI 01 · 2005


SITRANS F flowmeters
SITRANS F M
Magnetic water meter MAG 8000W

■ Schematics Selection and Ordering data Order-No. Order Code


SITRANS F M
Electrical installation and pulse output – Connection diagram
MAG 8000W Water meter 7 ME 6 8 1 0 -
Basic transmitter, compact, sensor coned, 77 7 0 1 - 7 A A 7 777
standard calibration, IrDA communication
Diameter
 DN 50 (2“) 2Y
0RGXOH 
 2XWSXW$
,QWHUIDFH  /1  DN 65 (2½“) 3F
2SWLRQ   DN 80 (3“) 3M
 
 DN 100 (4“) 3T
9'&
+/  DN 125 (5“) 4B
9
DN 150 (6“) 4H
DN 200 (8“) 4P
DN 250 (10“)
DN 300 (12“)
4V
5D
4
Flange norm and pressure rating
to EN 1092-1
PN 10 (DN 200 ... 300 / 8" ... 12") B
PN 16 (DN 50 ... 300 / 2" ... 12") C
to ANSI B16.5
class 150 J
to AS4087
Pulse connection terminals are placed to the right in the PCB class 14 N
board. Connection for add-on interface modules is placed to the Region version
left.
Europe with m3 unit and 50 Hz filter 1
HL = Hardware lock key connection USA with Gallon unit and 60 Hz filter 2
V = Push button for verification mode Australien with ML unit and 50 Hz filter 3
Pulse wire connection Power

0$* Internal battery pack 1


,QWHUQDOFRQQHFWLRQ ([WHUQDOFRQQHFWLRQ External IP68/NEMA 6P battery pack 2
&RQQHFWLRQ9DULDQW

Positive logic
V
Further designs Order Code
Passive output
Open drain
0V
Please add "-Z" to Order No. and specify Order code(s).
Output A
56 +
I < 50mA
Flow unit
V < 35 VDC

Signal l/s L00


57 R MGD L01
Negative logic CFS L02
66 V l/min L03
67
0V m3/min L04
Output B
V < 35 VDC GPM L05
I < 50mA R
+
Signal
CFM L06
l/h L07
m3/h L08
The pulse output can be configured as volume, alarm or call-up. GPH L09
The output can be connected as positive or negative logic. CFH L10
R = pull up/down is selected in relation to the Vx power supply GPS L11
and with a max. current I of 50 mA. MLD L12
m3/d L13
GPD L14
Volume unit
m3 L40
Ml L41
G L42
AF L43
l x 100 L44
m3 x 100 L45
G x 100 L46
CF x 100 L47
MG L48
G x 1000 L49
CF x 1000 L50
AI L51

Siemens FI 01 · 2005 4/95


SITRANS F flowmeters
SITRANS F M
Magnetic water meter MAG 8000W

■ Selection and Ordering data Description Order No. Symbol


MAG 8000W Hardware key to FDK:087L4165
Accessories access protected parameters
Description Order No. Symbol
PC Flow Tool on CD (move FDK:087L6001
down for free from
www.siemens.com/flow)

MAG 8000W demo - training FDK:087L4080


unit pack. Transmitter with
Flow tool CD, IrDA interface
adapter and hardware key
IrDA infrared interface adapter FDK:087L4163
with USB for data acquisition
with 1.2 m cable
4

Battery replacement pack, 2 FDK:087L4150


D-cell (33 Ah) and accessories
(2 sets in each package)

External battery pack FDK:087L4151


IP68/NEMA 6P with connector,
4 D-cell (66 Ah)

Glands reduction from M20 to FDK:087L4153


M12 package (25 pcs)

Cable entry one 6 ... 8 mm FDK:087L4121


M20 brass glands package
(1 pc)
Cable entry one 3.5 ... 5 mm FDK:087L4154
M12 brass glands package
(25 pcs)
Cable entry one 6 ... 8 mm FDK:087L4155
M20 brass glands package
(50 pcs)
Cable entry one 8 ... 11 mm FDK:087L4156
M20 brass glands package
(50 pcs)
Cable entry one 11 ... 15 mm FDK:087L4157
M20 brass glands package
(50 pcs)
Cable entry two 3.5 ... 5 mm FDK:087L4158
M20 brass glands package
(50 pcs)
Cable entry two 5.5 ... 7.5 mm FDK:087L4159
M20 brass glands package
(50 pcs)
IP68/NEMA 6P potting kit FDK:087L4160