You are on page 1of 4

Responsible: Construction project:

Construction member:
Position:
Date: August 13, 2021

JORDAHL® EXPERT Punching shear - Design


1. Input information
Column type Rectangular internal column
Column dimension cx / cy = 36 in / 36 in

Slab type In-situ concrete slab


Slab thickness h = 9 in
Concrete cover top/bottom co / cu = 1.75 in / 1.75 in
Effective depth dx / dy = 6.688 in / 6.688 in
Concrete strength 2500 psi
Density Normal concrete
Prestress fpc = 0 psi

Punching shear load Vu = 198 kip


Unbalanced moment Mux / Muy = 122 kip-ft / 65.1 kip-ft
Seismic loading Yes
Reinforcement diameter ϕx / ϕy = #5 / #4
Distances sx / sy = 12 in / 12 in

2. Output information (ACI 318-14)


2.1 Inner Critical Section (d/2 outside of column face)
2.1.1 Common Properties
Area Ac = 1141.9 in²
Critical section perimeter b0 = 170.8 in
2.1.2 Natural Axis Properties
Centroid coordinate ex / ey = 0 in / 0 in
5 5
Section moment of inertia Ix / Iy = 3.468·10 in⁴ / 3.468·10 in⁴
Section product of inertia Ixy = 0 in⁴
2.1.3 Principal Axis Properties
Centroid coordinate e1 / e2 = 0 in / 0 in
Section moment of inertia I1 / I2 = 3.468·105 in⁴ / 3.468·105 in⁴
Principal axis rotation θ = 0.0 °
Moment fraction γ1 / γ2 = 0.4000 / 0.4000
Unbalanced moment Mu1 / Mu2 = 122 kip-ft / 65.1 kip-ft

JORDAHL H-BAU AG Wasterkingerweg 2, CH-8193 Eglisau JORDAHL® EXPERT Punching shear Page 1 from 4
www.jordahl-hbau.ch Version: 4.2.2.39
Responsible: Construction project:
Construction member:
Position:
Date: August 13, 2021

2.1.4 Stresses
Maximum shear stresss vu = 228.7 psi
x/y = 21.344 in / -21.344 in
Shear resistance (concrete only) ϕvc = 133.7 psi
Shear resistance (with studrails) ϕvn = 543.5 psi
Shear resistance (upper limit) ϕvn,max = 300 psi

2.2 Outer Critical Section (d/2 outside of reinforced zone)


2.2.1 Common Properties
Area Ac = 2939.8 in²
Critical section perimeter b0 = 439.6 in
2.2.2 Natural Axis Properties
Centroid coordinate ex / ey = 0 in / 0 in
6 6
Section moment of inertia Ix / Iy = 6.736·10 in⁴ / 6.736·10 in⁴
Section product of inertia Ixy = 0 in⁴
2.2.3 Principal Axis Properties
Centroid coordinate e1 / e2 = 0 in / 0 in
6 6
Section moment of inertia I1 / I2 = 6.736·10 in⁴ / 6.736·10 in⁴
Principal axis rotation θ = 0.0 °
Moment fraction γ1 / γ2 = 0.4000 / 0.4000
Unbalanced moment Mu1 / Mu2 = 122 kip-ft / 65.1 kip-ft
2.2.4 Stresses
Maximum shear stresss vu = 74.3 psi
x/y = 18.385 in / -70.094 in
Shear resistance ϕvc = 75 psi

3. Elements
Number of studrails per column = 16
Number of studs per studrail = 15
Stud diameter D = 0.75 in
Stud spacing S / S0 = 3.25 in / 3.25 in
Overall height of studrail OAH = 5.5 in
Overall length of studrail OAL = 52 in

JORDAHL H-BAU AG Wasterkingerweg 2, CH-8193 Eglisau JORDAHL® EXPERT Punching shear Page 2 from 4
www.jordahl-hbau.ch Version: 4.2.2.39
Responsible: Construction project:
Construction member:
Position:
Date: August 13, 2021

4. Note
• The design against punching shear failure is based on the rules of ACI 318-14.
• This calculation is bases on product specific properties of DECON® Studrails®. Changes, even to similar
products, are only possible with new calculations.
• All data have to be checked with the given edge boundaries and the feasibility. DECON assumes no
liability for the input data of the user.

JORDAHL H-BAU AG Wasterkingerweg 2, CH-8193 Eglisau JORDAHL® EXPERT Punching shear Page 3 from 4
www.jordahl-hbau.ch Version: 4.2.2.39
Responsible: Construction project:
Construction member:
Position:
Date: August 13, 2021

JORDAHL H-BAU AG Wasterkingerweg 2, CH-8193 Eglisau JORDAHL® EXPERT Punching shear Page 4 from 4
www.jordahl-hbau.ch Version: 4.2.2.39