You are on page 1of 6

Proportional Pressure-Reducing 13

Valve for Hydraulics


Product group

V1300.4982 VR 030
Function
zz Large proportionality between magnetic current and control
pressure
zz Largely constant operating pressure in the flow range
zz Control pressure: 28,5 bar
zz Tank pressure (static pressure armature space): 30 bar
zz Small hysteresis through precise armature bearing
zz Quick response times
Construction Fig. 1: Type VR 030 AA 035 V02

zz Compact design
zz Fastening via flange fastening
zz Protection class according to DIN VDE 0470/EN 60529: IP65
according to DIN 40050 T9: IP6K6 and IPX9X
if mounted properly and with suitable mating connector
zz Electrical connection:
zz Plug connection AMP connector alternatively
Deutsch connector DT04-2P
Application examples
zz In particular proportional actuator in hydraulic control
chains and control loops
Options and accessories on request
zz Filter at pump connection
zz Further max. control pressures
zz Versions with further reduced hysteresis
zz Further electrical connections
zz Manual override

Magnet-Schultz GmbH & Co. KG • Allgäuer Straße 30 • D-87700 Memmingen • Tel. +49 83 31 10 40 • www.magnet-schultz.com
Technical data 
VR 030 AA 035 V02 V03
Hydraulic data
Control pressure (bar) 28,5
Input pressure (bar) max. 50
Tank pressure static (bar) max. 30
Tolerance band for pressure control
characteristic curve as delivered from
the factory (applies for horizontal
installation position and for lower
characteristic curve)
I1 = 0,6 A (12 V); I1 = 0,3 A (24 V) (bar) p = 5,75 ±1,75
I2 = 1,5 A (12 V); I2 = 0,75 A (24 V) (bar) p = 28,5 ±2,5
Flow P → A (∆p=10 bar) (l/min) >4
Flow A → T (∆p=10 bar) (l/min) >4
Leakage P → T (l/min) < 0,1 (50° oil temperature)
Hysteresis (with PWM 125 Hz) in new condition < 0,85 bar (lower hysteresis on request)
Medium Hydraulic oil according to DIN 51524, ATF oil
Oil temperature (°C) -20 to + 80
Oil pollution degree 20 / 18 / 15 according to ISO 4406
Elektrical data
Resistance (Ω) 4,5 ±6% (12 V) / 19,3 ±6% (24 V)
Limit current (A) 1,5 (12 V) / 0,75 (24 V)
Operating mode S1 (100 %)
Operating frequency PWM (Hz) 125
Plug connector AMP-Junior Timer Fa. Compagnie Deutsch DT04-2P
(Coding 1)
Ambient temperature (°C) -30 bis +80

Rated voltage Please make sure that the described devices are suitable for
The devices correspond to protection class III. Electrical equipment your application. Our offers for these devices are based on
of protection class III may be only connected to low voltage systems the assumption of maximal 8 in an FMEA severity table, i. e.
(PELV, SELV)(IEC 60364-4-4-41). in case of malfunction of the device model as offered, there
is, amongst others, no jeopardy of life or limb. Supplementary
Information and remarks concerning European directives information concerning its proper installation can be taken
can be taken from the correspondent information sheet which is also from the –Technical Explanation, the effective
available under Produktinfo.Magnet-Schultz.com. DIN VDE0580 as well as the relevant specifications.

Note on the RoHS Directive This part list is a document for technically qualified personnel.
According to our current state of knowledge the devices pictured The present publication is for informational purposes only and shall
in this document do not contain any substances in concentration not be construed as mandatory illustration of the products unless
values or applications for which putting into circulation with products otherwise confirmed expressively.
manufactured from them is prohibited in accordance to RoHS.

By edition of the present list, all former unit lists lose their validity especially. Illustrations without guarantee – modifications and supply availability reserved

2
Dimensional drawing

Fig. 2: Type VR 030 AA 035 V02

By edition of the present list, all former unit lists lose their validity especially. Illustrations without guarantee – modifications and supply availability reserved

3
Dimensional drawing

Fig. 3: Type VR 030 AA 035 V03

By edition of the present list, all former unit lists lose their validity especially. Illustrations without guarantee – modifications and supply availability reserved

4
Recommended cavity

Fig. 4: Recommended cavity Type VR 030 AA 035 V02


Type VR 030 AA 035 V03

By edition of the present list, all former unit lists lose their validity especially. Illustrations without guarantee – modifications and supply availability reserved

5
Subject to Sales Terms applay, available at www.Magnet-Schultz.com
6 112020/19 Alt