You are on page 1of 101

ZXR10 M6000-S/M6000-2S

Carrier-Class Router Introduction


Contents

 ZXR10 M6000-S/M6000-2S System Structure


 Product Overview
 Boards

 Power Supply Module

 Heat Dissipation System

 ZXR10 M6000-S/M6000-2S Features and


Capacity
 ZXR10 M6000-S/M6000-2S Network Application
Product Overview

 ZXR10 M6000-S/M6000-2S series are large capacity, high


performance and carrier-class Broadband Multi-Service Gateway
(BMSG) .
 ZXR10 M6000-S/M6000-2S series routers adopt modularized
structure design and provide different types of service interfaces.
 The key modules of the system use redundant design, which
makes the system more reliable.
 The high-speed network processors together with effective
software technologies realize fast routing policies.
 ZXR10 M6000-S/M6000-2S series routers consist of six models:
ZXR10 M6000-8S/-5S/-3S/-18S/-2S10/-2S4

© ZTE Corporation. All rights reserved


M6000-S/M6000-2S Overview

M6000-8S M6000-5S M6000-3S

© ZTE Corporation. All rights reserved


M6000-S/M6000-2S Overview

M6000-18S M6000- M6000-2S4


2S10

© ZTE Corporation. All rights reserved


M6000-S/M6000-2S Specifications
M6000-8S M6000-5S M6000-3S
Total slots 12 7 5
Service slots 8 5 3
Dimensions 619.5×442×749.4 DC:308.3×442×740 DC:175×442×738
(height (mm)× AC:352.8×442×740 AC:219.4×442×738
width (mm)×
depth(mm))
Weight DC: 127kg DC: 75kg DC: 47kg
(Chassis with
- AC: 81kg AC: 53kg
full
configuration)
-48 V DC :1+1 -48 V DC :1+1 -48 V DC :1+1
Power Supply
redundancy in 220 V AC :1+1 220 V AC :1+1
redundancy
each area
MPU/SRU 1:1
redundancy
Switch 3+1 1+1 FULLMESH
redundancy
MPU/SRU/SFU/PFU/PIU boards, power supply modules, and fan modules
Hot swapping support hot-swapping

© ZTE Corporation. All rights reserved


M6000-S/M6000-2S Specifications
M6000-18S M6000-2S10 M6000-2S4
Total slots 28 12 6
Service slots 18 10 4
Dimensions 1819.6×442×634 219.4×442×220 130.5×442×220
(height (mm)×
width (mm)×
depth(mm))
Weight DC (N+1): 348kg DC: 21kg DC: 14.9kg
(Chassis with DC (N+N): 355kg
full
AC: 357kg - -
configuration)
-48 V DC :11+1/8+8 -48 V DC :1+1 -48 V DC :1+1
Power Supply
220 V AC: 8+8
redundancy

MPU/SRU 1:1
redundancy
Switch 6+2 FULLMESH FULLMESH
redundancy
MPU/SRU/SFU/PFU/PIU boards, power supply modules, and fan modules
Hot swapping support hot-swapping

© ZTE Corporation. All rights reserved


System Structure — M6000-8S
Switching and Routing Unit(SRU)
2 SRU Boards,1:1 redundant backup

Switch Fabric Unit(SFU)


2 SFU Boards,3+1 redundant backup with SRU

Service Line Card(PFU+PIU)


8 PFU Boards

Air inlet

Fan:5 fan modules


Power: redundancy backup mode, 2+2,<4000WAC
Weight: chassis (including backplane)31.2kg,full load<95kg

© ZTE Corporation. All rights reserved


M6000-8S Hardware Structure

Line card PFU


Power/CLK Power/CLK
Switch card SFU
Physics Line Switch
POS/ETHERNET interfac processi interfac
Control Control
TDM/ATM e unit ng unit e unit
HSSL HSSL 4
1 3
2 Switch Matrix 2
1
8

b
a Ethernet
General Service card GSU Management Process Unit MPU
Power/CLK c Power/CLK
k Ethernet Maintenance
RS232
Service Switch Control p switch unit Management
processi interfac l unit ZXR10-OAM
2.048MHz
ng unit e unit a Control
HSSL n System 2.048Mbps
management and
e Clock TOD/PP1S
maintenance unit module
1 M S
2
8

Power
Power Fan
supply module
module
.. 5
2
1 1
2
3
4

© ZTE Corporation. All rights reserved


System Structure — M6000-5S
DC Power Supply
Service Line Card(PFU+PIU)
5 PFU+PIU Boards

Switching and Routing Unit(SRU)


2 SRU boards, 1:1 redundant backup and Switch
Fabric Unit is in 1+1 redundant backup

Power:1+1 redundant backup,<2000W Fan:3 fan modules


Weight: chassis (including backplane)15.4kg
,Full load< 55kg

© ZTE Corporation. All rights reserved


System Structure — M6000-5S
AC Power Supply
Service Line Card(PFU+PIU)
5 PFU+PIU Boards
Switching and Routing Unit(SRU)
2 SRU boards, 1:1 redundant backup and Switch
Fabric Unit is in 1+1 redundant backup

Power:1+1 redundant backup,<2000W Fan:3 fan


Weight: chassis (including modules
backplane)18kg,Full load< 58kg
© ZTE Corporation. All rights reserved
M6000-5S Hardware Structure

Line card PFU


Power/CLK Power/CLK
Switch card SFU
Physics Line Switch
POS/ETHERNET interfac processi interfac
Control Control
TDM/ATM e unit ng unit e unit
HSSL HSSL
1
2 Switch Matrix 2
1
5

b
a Ethernet
General Service card GSU Management Process Unit MPU
Power/CLK c Power/CLK
k Ethernet Maintenance
RS232
Service Switch Control p switch unit Management
processi interfac l unit ZXR10-OAM
2.048MHz
ng unit e unit a Control
HSSL n System 2.048Mbps
management and
e Clock TOD/PP1S
maintenance unit module
1 M S
2
5

Power
Power Fan
supply module
module
3
2
1 1
2

© ZTE Corporation. All rights reserved


System Structure — M6000-3S
DC Power Supply
Service Line Card(PFU+PIU)
3 PFU+PIU Boards

MPU
2 MPU Boards,1:1 redundant backup

Fan:2 fan modules

Power:1+1 redundant backup ,<1500W


Weight: chassis (including backplane)11.2kg,
Full load< 35kg
© ZTE Corporation. All rights reserved
System Structure — M6000-3S
AC Power Supply
Service Line Card(PFU+PIU)
3 PFU+PIU Boards

MPU
2 MPU Boards,1:1 redundant backup

Power:1+1 redundant backup ,<1500W


Weight: chassis (including
backplane)13.2kg,Full load< 37kg

Fan:2 fan modules

© ZTE Corporation. All rights reserved


M6000-3S Hardware Structure

Line card PFU


Power/CLK
Physics Line Switch
POS/ETHERNET Control
interface processin interface
TDM/ATM
unit g unit unit
HSSL

1
2
3

b Ethernet
General Service card GSU a Management Process Unit MPU
Power/CLK c Power/CLK
k Ethernet Maintenance RS232
Service Switch Control p switch unit Management
processin interface l ZXR10-OAM
a unit 2.048MHz
g unit unit HSSL Control System
n 2.048Mbps
e management and Clock TOD/PP1S
maintenance module
1 unit M S
2
3

Power
Fan module
Power
supply
module
2
1
1
2

© ZTE Corporation. All rights reserved


System Structure — M6000-18S
Power: N+1/N+N redundant backup

Main Processing Unit(MPU)


2 MPU Boards, 1:1 redundant backup

Service Line Card(PFU+PIU)


18 PFU Boards

Fan: 12 fan modules

Switch Fabric Unit(SFU)


8 SFU Boards, 6+2 redundant backup

© ZTE Corporation. All rights reserved


M6000-18S Hardware Structure

Line card PFU


Power/CLK Power/CLK
Switch card SFU
Physics Line Switch
POS/ETHERNET interfac processi interfac
Control Control
TDM/ATM e unit ng unit e unit
HSSL HSSL 4
1 3
2 Switch Matrix 2
1
8

b
a Ethernet
General Service card GSU Management Process Unit MPU
Power/CLK c Power/CLK
k Ethernet Maintenance
RS232
Service Switch Control p switch unit Management
processi interfac l unit ZXR10-OAM
2.048MHz
ng unit e unit a Control
HSSL n System 2.048Mbps
management and
e Clock TOD/PP1S
maintenance unit module
1 M S
2
8

Power
Power Fan
supply module
module
.. 5
2
1 1
2
3
4

© ZTE Corporation. All rights reserved


System Structure — M6000-2S10

Service Line Card(PIU)


8 PIU Boards

Service Line Card(PFU)


2 PFU Boards

Main Processing Unit (MPU)


2 MPU Boards, 1:1 redundant backup

Power: 1+1 redundant backup

Fan: 1 fan modules

© ZTE Corporation. All rights reserved


System Structure — M6000-2S4

Service Line Card(PFU)


2 PFU Boards

Service Line Card(PIU)


2 PIU Boards

Main Processing Unit (MPU)


2 MPU Boards, 1:1 redundant backup

Power: 1+1 redundant backup

Fan: 1 fan modules

© ZTE Corporation. All rights reserved


M6000-2S Hardware Structure

Line card PFU


Power/CLK
Physics Line Switch
POS/ETHERNET Control
interface processin interface
TDM/ATM
unit g unit unit
HSSL

1
2
3

b Ethernet
General Service card GSU a Management Process Unit MPU
Power/CLK c Power/CLK
k Ethernet Maintenance RS232
Service Switch Control p switch unit Management
processin interface l ZXR10-OAM
a unit 2.048MHz
g unit unit HSSL Control System
n 2.048Mbps
e management and Clock TOD/PP1S
maintenance module
1 unit M S
2
3

Power
Fan module
Power
supply
module
2
1
1
2

© ZTE Corporation. All rights reserved


Contents

 ZXR10 M6000-S/M6000-2S System Structure


 Product Overview
 Boards

 Power Supply Module

 Heat Dissipation System

 ZXR10 M6000-S/M6000-2S Features and


Capacity
 ZXR10 M6000-S/M6000-2S Network Application
Slot Layout -- M6000-8S

M6000-8S Slot Layout


(Front)
0 1 2 3 1 8 11 4 5 6 7
Slot 0
9

P P P P S S S P P P P
F F F F R F R F F F F
U U U U U U U U U U U
S
F
U

© ZTE Corporation. All rights reserved


Slot Layout -- M6000-8S

M6000-8S Slot Layout (Back)

0 1 2 3 4
FAN FAN FAN FAN FAN
0 1 2 3
PWR PWR PWR PWR

© ZTE Corporation. All rights reserved


Slot Layout -- M6000-5S DC ZXR10 M6000-5S DC Slot
Slot Layout Front
4 PFU
3 PFU
2 PFU
6 SRU
5 SRU
1 PFU
0 PFU

Slot Back Slot Back


0 DC POWER 0 FAN
1 FAN
1 DC POWER 2 FAN

© ZTE Corporation. All rights reserved


Slot Layout -- M6000-5S AC ZXR10 M6000-5S AC Slot
Slot Layout Front
4 PFU
3 PFU
2 PFU
6 SRU
5 SRU
1 PFU
0 PFU
0 1 AC PWR AC PWR

Slot Back Slot Back


0 DC POWER 0 FAN
1 FAN
1 DC POWER 2 FAN

© ZTE Corporation. All rights reserved


Slot Layout -- M6000-3S DC

 ZXR10 M6000-3S DC Slot Layout


Slot Front
2 PFU
1 PFU
0 PFU
3 4 MPU MPU

Slot Back Slot Back


0 DC POWER 0 FAN
1 DC POWER 1 FAN

© ZTE Corporation. All rights reserved


Slot Layout -- M6000-18S/M6000-2S10/M6000-
2S4

M6000-
M6000-
18S
2S10

M6000-2S4

© ZTE Corporation. All rights reserved


Board Classification for M6000-S

Silk Screen Name Type Description

M6KS-MPU-18-1D MPU Type-1D MPU board(supported by ZXR10 M6000-18S)

M6KS-MPU-A MPU Type-A MPU board(supported by ZXR10 M6000-3S)

M6KS-MPU-1A MPU Type-1A MPU board(supported by ZXR10 M6000-3S)

M6KS-SRU-A SRU Type-A SRU board(supported by ZXR10 M6000-8S and -5S)

M6KS-SRU-1A SRU Type-1A SRU board(supported by ZXR10 M6000-8S and -5S)

M6KS-SRU-1H SRU Type-1H SRU board(supported by ZXR10 M6000-8S and -5S)

M6KS-SFU-18-H SFU Type-H SFU board(supported by ZXR10 M6000-18S)

M6KS-SFU-A SFU Type-A SFU board(supported by ZXR10 M6000-8S)

M6KS-SFU-8-H SFU Type-H SFU board(supported by ZXR10 M6000-8S)

© ZTE Corporation. All rights reserved


Board Classification for M6000-S
Silk Screen Name Type Description
Type-B 20G NP board, two daughter card slots, interconnected
M6KS-PFU-20-B2 PFU to half-height daughter cards and full-height cards
Type-A 40G NP board, two daughter card slots, interconnected
M6KS-PFU-40-A2 PFU to half-height daughter cards and full-height cards
Type-A 10G NP board, four daughter card slots, interconnected
M6KS-PFU-10-A4 PFU to quarter-height daughter cards
Type-H 20G NP board, two daughter card slots, interconnected
M6KS-PFU-20-H2 PFU to half-height daughter cards and full-height cards
Type-H 40G NP board, two daughter card slots, interconnected
M6KS-PFU-40-H2 PFU to half-height daughte cards and full-height cards
Type-H 50G NP board, two daughter card slots, interconnected
M6KS-PFU-51-H2 PFU to half-height daughter cards and full-height cards
Type-H 100G NP board, two daughter card slots, interconnected
M6KS-PFU-100-H2 PFU to half-height daughter cards and full-height cards
Type-H 120G NP board, two daughter card slots, interconnected
M6KS-PFU-101-H2 PFU to half-height daughter cards and full-height cards
Type-H 200G NPboard, two daughter card slots, interconnected
M6KS-PFU-201-H2 PFU to half-height daughter cards and full-height cards
Type-H 8G NP board, four daughter card slots, interconnected
M6KS-PFU-11-H4 PFU to quarter-height daughter cards

© ZTE Corporation. All rights reserved


Board Classification for M6000-S
Silk Screen Name Type Description

RPS-20GE-SFP PIU 20-port half-height GE optical interface daughter card

RPS-01XGE-SFP+ PIU 1-port half-height 10GE LAN/WAN interface daughter card

RPS-02XGE-SFP+ PIU 2-port half-height 10GE LAN/WAN interface daughter card


4-port quarter-height OC-3c/STM-1c POS interface daughter
RPS-04P3/P12-SFP PIU card

RPU-01XLGE-CFP PIU 1-port half-height 40GE LAN interface daughter card

RPU-01CGE-CFP PIU 1-port full-height 100GE LAN interface daughter card


3-port 40GE interface board(half-height daughter card),
RPH-03XLGE-QSFP+-S PIU supports 1588v2
1-port 100GE interface board(half-height daughter card),
RPH-01CGE-CFP-S PIU supports 1588v2
General service processing board, two functional daughter
M6KS-GSU-A2 GSU card slots
Type-I enhanced daughter card, used for M6KS-GSU-A2, half-
M6KS-GIU-A-I GIU height daughter card

© ZTE Corporation. All rights reserved


Board Classification for M6000-2S
Silk Screen Name Type Description

Type-1D MPU board(supported by ZXR10 M6000-


M6KS-MPU-2-1D MPU 2S10 and M6000-2S4)

M6KS-PFUA-04XG-SFP+ PFU Service processing board of the ZXR10 M6000-2S10

M6KS-PFUA PFU Service processing board of the ZXR10 M6000-2S10

M6KS-PFUAR PFU Service processing board of the ZXR10 M6000-2S10

M6KS-PFUB-04XG16G-SFP+ PFU Service processing board of the ZXR10 M6000-2S4

M6KS-PFUB-16G-SFP PFU Service processing board of the ZXR10 M6000-2S4

M6KS-PFUC-04XG16G-SFP+RJ PFU Service processing board of the ZXR10 M6000-2S4

© ZTE Corporation. All rights reserved


Board Classification for M6000-2S

Silk Screen Name Type Description


1-Port quarter-height 10GE optical interface daughter
RPN-01XGE-SFP+-S PIU card
2-Port quarter-height 10GE optical interface daughter
RPN-02XGE-SFP+-S PIU card
1-Port quarter-height OC-192c/STM-64c POS
RPN-01P192-SFP+ PIU interface daughter card
2-Port quarter-height OC-192c/STM-64c POS
RPN-02P192-SFP+ PIU interface daughter card
24-Port quarter-height channelized E1 PWE3 interface
RPN-24CE1-DB50-75 PIU daughter card
24-Port quarter-height channelized E1 PWE3 interface
RPN-24CE1-DB50-75-CES PIU daughter card
24-Port quarter-height channelized E1 PWE3 interface
RPN-24CE1-DB50-120 PIU daughter card
24-Port quarter-height channelized E1 PWE3 interface
RPN-24CE1-DB50-120-CES PIU daughter card

© ZTE Corporation. All rights reserved


M6000-18S MPU
 MPU Board: M6KS-MPU-18-1D
 MPU is the control center of M6000-18S system, 1:1 redundant.
 Manages and maintains the router
 Processes dynamic routing protocols
 Provides the reset function, in-position signal collection and active/ standby indicator signals for SFU boards,
PFU boards
 Manages line interface boards
 Provides interfaces for operation and management of the router system
 Provides the system environment monitoring function

© ZTE Corporation. All rights reserved


M6KS-MPU-18-1D Panel

© ZTE Corporation. All rights reserved


M6KS-MPU-18-1D Panel Description - Interfaces
Interface Type Description
Downloads the version file and monitors network
MGMTETH RJ45interface
ports.
STDBY RJ45interface Debugginginterface.
Connects to a back-end management terminal for
CONSOLE RJ45interface operation and maintenance through a tool, for
example, Hyper Terminal.
Connects to a Modulator-Demodulator(MODEM)
AUX RJ45interface
for remote management.
USB USBinterface Interface for a USB storage device.
ALMIN RJ45interface Alarm input interface.
ALMOUT RJ45interface Alarm output interface
LAMP RJ45interface Interface for turning on the alarm indicator.
GPSIN RJ45interface External interface for GPS clock input.
GPSOUT RJ45interface External interface for GPS clock output.
External interface for 2.048MHz or 2.048Mbit/s
CLK1 SMB
clock input/output.
External interface for 2.048MHz or 2.048Mbit/s
CLK2 SMB
clock input/output.
© ZTE Corporation. All rights reserved
M6KS-MPU-18-1D Panel Description –
Indicators
Module Indicator Color Description

System operation indicator. It flashes when the system is operating


RUN Green
properly.

System ALM Red


System alarm indicator. It is on when a fault occurs and off when the
system state is normal.
operation
state System active indicator. It is on when the board is active and off
ACT Green
when the board is standby.

Indicates whether hot swapping is allowed. Off: The board is


OFL Red operating properly and hot swapping is disallowed. Solid on: Hot
swapping is allowed.

The ACT indicator for the first gigabit electrical interface. It flashes
ACT Yellow
when there are packets being sent and received.

The link indicator for the first gigabit electrical interface. It is on


Gigabit LNK Green
when the link is normal.
electrical
interface The ACT indicator for the second gigabit electrical interface. It
ACT Yellow
flashes when there are packets being sent and received.

The link indicator for the second gigabit electrical interface. It is on


LNK Green
when the link is normal.

© ZTE Corporation. All rights reserved


M6KS-MPU-18-1D Panel Description – Buttons

Button Description
Function button. It is used to collect the system operation
FUN state and configuration. Press this button for more than 6
seconds.
RST Reset button. It is used to reset this board.
Active/standby switchover and hot swapping button. When
this board is active, this button is an active/standby
switchover button. Press this button to switchover between
EXCH/OFL the active and the standby boards manually. When this
board is standby, this button is a hot swapping button.
Press this button for more than 6 seconds until the OFL
indicator is on and then the board can be removed.
Ring button. By pressing it for more than 6 seconds, the
RING
ring stops.

© ZTE Corporation. All rights reserved


M6000-3S MPU

 MPU board:M6KS-MPU-A
 Manages and maintains the router
 Processes dynamic routing protocols
 Provides the reset function, in-
position signal collection and
active/standby indicator signals for
SFU boards, PFU boards, and ESU
boards
 Manages line interface boards
 Provides interfaces for operation and
management of the router system
 Provides the system environment
monitoring function

© ZTE Corporation. All rights reserved


M6KS-MPU-A Panel

© ZTE Corporation. All rights reserved


M6KS-MPU-A Panel Description - Interfaces

Interface Type Description


MGMT ETH RJ45 Download the version file and monitor network
Ports.
USB USB Interface for USB storage devices.
CONSOLE RJ45 Connect to a back-end management terminal for
operation and maintenance through a tool, for
example, HyperTerminal.
AUX RJ45 Connect to a MODEM for remote management
CLK1 SMB External interface for 2.048 MHz or 2.048 Mbit/s
clock
input/output.
CLK2 SMB External interface for 2.048MHz or 2.048 Mbit/s
clock
input/output.
GPS IN RJ45 External interface for GPS clock input.
GPS OUT RJ45 External interface for GPS clock output.

© ZTE Corporation. All rights reserved


M6KS-MPU-A Panel Description – Indicators and
Buttons
Module Indicator Color Description

System RUN Green System operation indicator. It flashes when the system is
Operation operating properly.
State
ALM Red System alarm indicator. It is on when a fault occurs and off when
the system state is normal.

ACT Green System active indicator. It is on when the board is active and off
Indicators when the board is standby.

OFL Red Indicates whether hot-plug is allowed.


Off: The board is operating properly and hot-plug is disallowed.
Constantly on: Hot-plug is allowed.
Gigabit ACT Yellow The ACT indicator for the first gigabit electrical interface. It
electrical flashes when there are packets being sent and received.
interface
LINK Green The link indicator for the first gigabit electrical interface. It is
turned on when the link is normal.

Button Descrption

FUN Function button. It is used to collect the system operation state and configuration. Press
this button for more than 6 seconds.
Buttons
RST Reset button. It is used to reset this board.
EXCH Active/standby changeover button. It is used to change over between the active board
and the standby board manually. When the board is a standby board, this button is a
hot-plug button.
© ZTE Corporation. All rights reserved
Technical Specifications of M6KS-MPU-A and
M6KS-MPU-1A
Parameter Specification
Silk screen name M6KS-MPU-A M6KS-MPU-1A
Dimensions
(W×H×D) 197.2mm×35.16mm×515.4mm 197.2mm×35.16mm×515.4mm
Power
consumption 50W 65W

Hot load 162 BTU/Hour 210.6 BTU/Hour

Weight 3.2kg 2.23kg


Dual-core, single-core CPU Four-core, single-core CPU
CPU speed 1.5GHz speed 1.2GHz

Memory Slot 2DIMMs 2DIMMs

Memory 4G(2G×2)/8G(4G×2) 8G(4G×2)/16G(8G×2)


default/maximum
capacity (byte)

© ZTE Corporation. All rights reserved


M6000-5S /8S SRU

 SRU Board: M6KS-SRU-A


 SRU is the control center of M6000 system, 1:1 redundant.
 Manages and maintains the router
 Processes dynamic routing protocols
 Provides the reset function, in-position signal collection and active/ standby indicator
signals for SFU boards, PFU boards, and ESU boards
 Manages line interface boards
 Provides interfaces for operation and management of the router system
 Provides the system environment monitoring function

© ZTE Corporation. All rights reserved


M6KS-SRU-A Panel

SRU Buttons
Button Description

FUN Function button. It is used to collect the system operation state and
configuration. Press this button for more than 6 seconds.

RST Reset button. It is used to reset this board.

EXCH/OFL Active/standby changeover and hot-plug button. When this board is active,
this button is an active/standby changeover button. Press this button to
change over
between the active and the standby boards manually. When this board is
standby, this button is a hot-plug button. Press this button for more than 6
seconds until the OFL indicator is on and then the board can be removed.

RING Ring button. By pressing it for more than 6 seconds, the ring stops.
© ZTE Corporation. All rights reserved
M6KS-SRU-A Panel Description - Interfaces
Mark Type Description
OAM RJ45 Download the version file and monitor network ports.
QX RJ45 Debugging interface.
CONSOLE RJ45 Connect to a back-end management terminal for operation and
maintenance through a tool, for example, HyperTerminal.
AUX RJ45 Connect to a Modulator-Demodulator (MODEM) for remote
management.
USB USB Interface for a USB storage device.
ALM IN RJ45 Alarm input interface
ALM OUT RJ45 Alarm output interface.
LAMP RJ45 Interface for turning on the alarm indicator.
GPS IN RJ45 External interface for GPS clock input.
GPS OUT RJ45 External interface for GPS clock output.
CLK1 SMB External interface for 2.048 MHz or 2.048 Mbit/s clock input/output.
CLK2 SMB External interface for 2.048MHz or 2.048 Mbit/s clock input/output.

© ZTE Corporation. All rights reserved


M6KS-SRU-A Panel Description - Indicators
Module Indicator Color Description
System RUN Green System operation indicator. It flashes when the system is operating
Operation properly.
State
ALM Red System alarm indicator. It is on when a fault occurs and off when the
system state is normal
ACT Green System active indicator. It is on when the board is active and off when
the board is standby.
OFL Red Indicates whether hot plug is allowed.
Off: The board is operating properly and hot plug is disallowed.
Constantly on: Hot plug is allowed.
Gigabit ACT Yellow The ACT indicator for the first gigabit electrical interface. It flashes
electric when there are packets being sent and received.
interface
LINK Green The link indicator for the first gigabit electrical interface. It is turned
on when the link is normal.
ACT Yellow The ACT indicator for the second gigabit electrical
interface. It flashes when there are packets being sent and received.
LINK Green The link indicator for the second gigabit electrical
interface. It is turned on when the link is normal.

© ZTE Corporation. All rights reserved


M6000-2S MPU

 MPU Board: M6KS-MPU-2-1D


 MPU is the control center of M6000-2S system, 1:1 redundant.
 Manages and maintains the router
 Processes dynamic routing protocols
 Provides the reset function, in-position signal collection and active/ standby
indicator signals for PFU boards
 Manages line interface boards
 Provides interfaces for operation and management of the router system
 Provides the system environment monitoring function

© ZTE Corporation. All rights reserved


M6KS-MPU-2-1D Panel Description - Interfaces
Interface Type Description
Downloads the version file and monitors network
OAM RJ45interface
ports.
External interface for the channel of network
QX RJ45interface
management system
Connects to a back-end management terminal for
CONSOLE RJ45interface operation and maintenance through a tool, for
example, Hyper Terminal.
Connects to a Modulator-Demodulator(MODEM)
AUX RJ45interface
for remote management.
USB USBinterface Interface for a USB storage device.
ALMIN RJ45interface Alarm input interface.
ALMOUT RJ45interface Alarm output interface
LAMP RJ45interface Interface for turning on the alarm indicator.
GPS RJ45interface External interface for GPS clock input or output.
External interface for 2.048MHz or 2.048Mbit/s
BITS IN SMB
clock input.
Interface for outputting 2.048MHz or 2.048Mbit/s
BITS OUT SMB
clock to a downstream device.
© ZTE Corporation. All rights reserved
M6KS-MPU-2-1D Panel Description - Indicators
Module Indicator Color Description
System operation indicator. It flashes when the system is
RUN Green
operating properly.

System ALM Red


System alarm indicator. It is on when a fault occurs and off
when the system state is normal.
operation
state System active indicator. It is on when the board is active and
ACT Green
off when the board is standby.

OFL Red Indicates whether hot swapping is allowed.

The ACT indicator for the gigabit electrical interface.


OAM OAM ACT Green It flashes when there are packets being sent and
Gigabit received.
electrical The link indicator for the gigabit electrical interface.
OAM LNK Green
interface It is on when the link is normal.
The ACT indicator for the gigabit electrical interface.
QX Gigabit QX ACT Green It flashes when there are packets being sent and
received.
electrical
interface The link indicator for the gigabit electrical interface.
QX LNK Green
It is on when the link is normal.
© ZTE Corporation. All rights reserved
M6KS-MPU-2-1D Panel Description - Buttons

Button Description
Function button. It is used to automatically collect system
FUN
information.
RST Reset button. It is used to reset this board.

Active/standby switchover button. It is used to switch over


between the active board and the standby board manually.
EXCH
When the board is a standby board, this button is a hot
swapping button.

© ZTE Corporation. All rights reserved


M6000-18S SFU

SFU Board: M6KS-SFU-18-H


•Non-cascade connection SFU board.
•It implements the high-speed switching of packets.
•SFU boards can implement load sharing and 7+1 redundancy protection.
SFU Indicator

Indicator Color Description

RUN/ALM Green/Red Operation/alarm indicator. When the system is operating


properly, it flashes in green. The cycle is 1 second. In
other situations, it is constantly on in red.

OFL Green Offline indicator. In normal situations, it is off. When it is


on, the board can be removed.

SFU Buttons
Button Description

OFL Hot-plug button. To plug out this board when the device is powered
on, it is necessary to press this button for more than 6 seconds.
When the OFL indicator is on, the board can be removed.

© ZTE Corporation. All rights reserved


M6000-8S SFU
 SFU Board: M6KS-SFU-A
 Non-cascade connection SFU board.
 It implements the high-speed switching of packets.
 Together with switching units , the SFU boards can
implement redundancy protection with 2 SRU boards
 M6000-8S 3+1

SFU Indicator
Indicator Color Description

RUN/ALM Green/Red Operation/alarm indicator. When the system is


operating properly, it flashes in green. The cycle is
1 second. In other situations, it is constantly on in
red.

OFL Green Offline indicator. In normal situations, it is off.


When it is on, the board can be removed.

SFU Buttons
Button Description

OFL Hot-plug button. To plug out this board when the device is powered
on, it is necessary to press this button for more than 6 seconds.
When the OFL indicator is on, the board can be removed.

© ZTE Corporation. All rights reserved


M6000-S PFU
 PFU board is the network processing board of
ZXR10 M6000-S series routers. The PFU board
provides the following functions:
 Implements the configuration of network
processor modules, provides different power

M6KS-PFU-20-A2 supplies for the modules and completes normal


operation through the peripheral interface bus.
 Implements interaction, link establishment and
forwarding between the TM module and SFU
through a high-speed SerDes link. With this link,
packets are forwarded between boards.
 Provides two gigabit Ethernet links to
M6KS-PFU-10-A4 communicate with the SRU or MPU boards.
 Supports EPLD and FPGA online download.
Implements two -48 V power supply accesses and
Ten types of PFU boards:

conversions of different power supplies on the


•M6KS-PFU-20-B2 board.
•M6KS-PFU-40-A2 •M6KS-PFU-100-H2
•M6KS-PFU-10-A4 •M6KS-PFU-101-H2
•M6KS-PFU-20-H2 •M6KS-PFU-201-H2
•M6KS-PFU-40-H2 •M6KS-PFU-11-H4
•M6KS-PFU-51-H2

© ZTE Corporation. All rights reserved


M6000-S PFU Descriptions-1
Silk Screen Name Slot Height Description

M6KS-PFU-20-B2 Two half-height (197.4 mm × 2) The throughput of each PIU is 10


G, and the M6KS-PFU-20-B2
board provides 20 G bidirectional
network processing ability.

M6KS-PFU-40-A2 Two half-height (197.4 mm × 2) The throughput of each PIU is 20


G, and the M6KS-PFU-40-A2
board provides 40 G bidirectional
network processing ability.

M6KS-PFU-10-A4 Four half-height (197.4 mm × The PIUs include GE, OC3 CPOS,
OC3/OC12 POS, OC48 POS, OC12
4) CPOS, CE1, OC3 ATM and OC12
ATM. The throughput of each
quarter-height PIU is 10Gbps. The
M6KS-PFU-10-A4 board provides
10 G bidirectional network
processing ability.

M6KS-PFU-20-H2 Two half-height (188.8 mm × 2) The throughput of each PIU is 20


G, and the M6KS-PFU-20-H2
board provides 20 G bidirectional
network processing ability.

M6KS-PFU-40-H2 Two half-height (188.8 mm × 2) The throughput of each PIU is 40


G, and the M6KS-PFU-40-H2
board provides 40 G bidirectional
network processing ability.

© ZTE Corporation. All rights reserved


M6000-S PFU Descriptions-2
Silk Screen Name Slot Height Description

M6KS-PFU-51-H2 Two half-height (188.8 mm × 2) The throughput of each PIU is 25


G, and the M6KS-PFU-51-H2
board provides 50 G bidirectional
network processing ability.

M6KS-PFU-100-H2 Two half-height (188.8 mm × 2) The throughput of each PIU is 50


G, and the M6KS-PFU-100-H2
board provides 100 G
bidirectional network processing
ability.

M6KS-PFU-101-H2 Two half-height (188.8 mm × 2) The throughput of each PIU is 60


G, and the M6KS-PFU-101-H2
board provides 120 G
bidirectional network processing
ability.

M6KS-PFU-201-H2 Two half-height (188.8 mm × 2) The throughput of each PIU is


100
G, and the M6KS-PFU-201-H2
board provides 200 G
bidirectional network processing
ability.

M6KS-PFU-11-H4 Four half-height (197.4 mm × The throughput of each PIU is 2 G,


and the M6KS-PFU-11-H4 board
4) provides 8 G bidirectional
network processing ability.

© ZTE Corporation. All rights reserved


M6000-S PFU Panel
M6KS-PFU-20-A2 Panel

M6KS-PFU-40-A2 Panel
 The indicators and
buttons of PFU
Board are the
same as SFU
M6KS-PFU-10-A4 Panel

© ZTE Corporation. All rights reserved


M6000-S- M6KS-PFU-10-A4

 M6KS-PFU-10-A4 provides 4 slots and it can support 4 semi-


height PIU.
 PIU supports the following functions:
 hot swap
 different types of daughter cards
 The throughput of each PIU is 10 G
© ZTE Corporation. All rights reserved
M6000-S- M6KS-PFU-20-A2

 M6KS-PFU-20-A2 provides 2 slots and it can support 2 semi-


height PIU or 1 full-height PIU.
 PIU supports the following functions:
 hot swap
 different types of daughter cards
 The throughput of each PIU is 20 G
© ZTE Corporation. All rights reserved
M6000-S- M6KS-PFU-40-A2

 M6KS-PFU-40-A2 provides 2 slots and it can support 2 semi-height PIU


or 1 full-height PIU.
 maximum bandwidth is 40Gbps
 PIU supports the following functions :
 hot swap
 different types of daughter cards
 The throughput of each PIU is 20 G
 compatible with all interface cards of M6KS-PFU-20-A2
© ZTE Corporation. All rights reserved
M6000-2S PFU- M6KS-PFUA-04XG-SFP+

 The M6KS-PFUA-04XG-SFP+ board is used as a service processing board of the


ZXR10 M6000-2S10.
 The M6KS-PFUA-04XG-SFP+ board provides 100 G bidirectional network
processing ability.

 The M6KS-PFUA-04XG-SFP+ board provides the following functions:


 Provides four 10 GE LAN interfaces
 Supports 1+1 and 1:1 redundancy backup
 Supports the IEEE 1588 timestamp mark function
 Supports hot swapping and implements the no-packet-loss switchover
 Supports input and output of IPv4 ACL and IPv6 ACL
 Supports the functions of BFD, MPLS OAM, ETH OAM, and TP OAM.

© ZTE Corporation. All rights reserved


M6000-2S PFU- M6KS-PFUA

 The M6KS-PFUA board is used as a service processing board of the ZXR10


M6000-2S10.
 The M6KS-PFUA board provides 100 G bidirectional network processing ability.

 The M6KS-PFUA board provides the following functions:


 Supports 1+1 and 1:1 redundancy backup
 Supports the IEEE 1588 timestamp mark function
 Supports hot swapping and implements the no-packet-loss switchover
 Supports input and output of IPv4 ACL and IPv6 ACL
 Supports the functions of BFD, MPLS OAM, ETH OAM, and TP OAM.

© ZTE Corporation. All rights reserved


M6000-2S PFU- M6KS-PFUAR

 The M6KS-PFUAR board is used as a service processing board of the ZXR10


M6000-2S10.
 The M6KS-PFUAR board provides 50 G bidirectional network processing ability.

 The M6KS-PFUAR board provides the following functions:


 Supports 1+1 and 1:1 redundancy backup
 Supports the IEEE 1588 timestamp mark function
 Supports hot swapping and implements the no-packet-loss switchover
 Supports input and output of IPv4 ACL and IPv6 ACL
 Supports the functions of BFD, MPLS OAM, ETH OAM, and TP OAM.

© ZTE Corporation. All rights reserved


M6000-2S PFU- M6KS-PFUB-04XG16G-SFP+

 The M6KS-PFUB-04XG16G-SFP+ board is used as a service processing board of the ZXR10


M6000-2S4.
 The M6KS-PFUB-04XG16G-SFP+ board provides 50 G bidirectional network processing ability.

 The M6KS-PFUB-04XG16G-SFP+ board provides the following functions:


 Supports 4×10GE LAN SFP+ Ethernet optical ports and 16×1GE LAN SFP Ethernet optical
ports.
 Supports 1+1 and 1:1 redundancy backup.
 Supports the IEEE 1588 timestamp mark function.
 Supports hot swapping and implements the no-packet-loss switchover.
 Supports input and output of IPv4 ACL and IPv6 ACL.
 Supports the functions of BFD, MPLS OAM, ETH OAM, and TP OAM.

© ZTE Corporation. All rights reserved


M6000-2S PFU- M6KS-PFUB-16G-SFP

 The M6KS-PFUB-16G-SFP board is used as a service processing board of the


ZXR10 M6000-2S4.
 The M6KS-PFUB-16G-SFP board provides 50 G bidirectional network processing
ability.

 The M6KS-PFUB-16G-SFP board provides the following functions:


 Supports 16×1GE LAN SFP Ethernet optical ports.
 Supports 1+1 and 1:1 redundancy backup.
 Supports the IEEE 1588 timestamp mark function.
 Supports hot swapping and implements the no-packet-loss switchover.
 Supports input and output of IPv4 ACL and IPv6 ACL.
 Supports the functions of BFD, MPLS OAM, ETH OAM, and TP OAM.

© ZTE Corporation. All rights reserved


M6000-2S PFU- M6KS-PFUC-04XG16G-SFP+RJ

 The M6KS-PFUC-04XG16G-SFP+RJ is used as a service processing board of the


ZXR10 M6000-2S4.
 The M6KS-PFUC-04XG16G-SFP+RJ board provides 50 G bidirectional network
processing ability.

 The M6KS-PFUC-04XG16G-SFP+RJ board provides the following functions:


 Provides four 10 GE LAN interfaces, 8 SFP optical interfaces, and eight RJ45
electrical interfaces
 Supports 1+1 and 1:1 redundancy backup
 Supports the IEEE 1588 timestamp mark function
 Supports hot swapping and implements the no-packet-loss switchover
 Supports input and output of IPv4 ACL and IPv6 ACL
 Supports the functions of BFD, MPLS OAM, ETH OAM, and TP OAM
© ZTE Corporation. All rights reserved
M6000-S PFU and PIU Connections-1
PFU M6KS-PFU-20-B2 M6KS-PFU-40-A2 M6KS-PFU-10-A4 M6KS-PFU-20-
H2
Supported RPS-01XGE-SFP+-S RPS-02XGE-SFP+-S RPS-08GE-SFP-S RPU-01XGE-SFP+
PIU RPS-01XGE-SFP+ RPS-02XGE-SFP+ RPS-08GE-SFP RPU-01XGE-SFP+-S
RPS-12GE-8SFP4C-S RPS-20GE-SFP-S RPS-08GE-RJ45-S RPU-12GE-SFP-S
RPS-12GE-8SFP4C RPS-20GE-SFP RPS-08GE-RJ45 RPU-12GE-SFP
RPS-01XGE-XFP-O RPS-02XGE-XFP-O RPS-04P48-SFP
RPS-01P192-XFP-O RPS-02P192-XFP-O RPS-08P3/P12-SFP
RPS-04P48A-SFP RPS-08P48-SFP RPS-04P3/P12-SFP
RPS-04CP3-SFP-CES
RPS-04CP3-SFP
RPS-24CE1-DB50-CES
RPS-24CE1-DB50

© ZTE Corporation. All rights reserved


M6000-S PFU and PIU Connections-2
PFU M6KS-PFU-40-H2 M6KS-PFU-51-H2 M6KS-PFU-100- M6KS-PFU-101-
H2 H2
Supported RPU-02XGE-SFP+ RPH-04XGE-SFP+-S RPU-01CGE-CFP-S RPH-01XLGE-CFP-S
PIU RPU-02XGE-SFP+-S RPH-02XGE-SFP+-S RPU-01CGE-CFP RPH-06XGE-SFP+-S
RPU-24GE-SFP-S RPH-05XGE-XFP-S RPU-01XLGE-CFP-S RPH-06XGE-XFP-S
RPU-24GE-SFP RPH-04XGE-XFP-S RPU-01XLGE-CFP RPH-04XGE20GE-
RPU-20GE-SFP-S RPH-02XGE-XFP-S RPU-05XGE-XFP-S SFP+-S
RPU-20GE-SFP RPH-01XGE-XFP-S RPU-05XGE-XFP RPH-04XGE16GE-
RPU-20GE-RJ45-S RPH-01XGE11GE- RPU-05XGE-SFP+ SFP+RJ45-S
RPU-20GE-RJ45 SFP+-S RPU-05XGE-SFP+-S
RPH-02XGE10GE- RPU-01P768-PIN300
SFP+-S RPU-04P192-XFP
RPH-24GE-SFP-S RPU-02XGE-XFP-O
RPH-20GE-SFP-S RPU-02P192-XFP-O
RPH-12GE-SFP-S RPU-01XGE-XFP-O
RPH-02XGE16GE- RPU-01P192-XFP-O
SFP+RJ45-S

© ZTE Corporation. All rights reserved


M6000-S PFU and PIU Connections-3

PFU M6KS-PFU-201-H2 M6KS-PFU-11-H4

Supported PIU RPH-01CGE-CFP-S RPH-08P3/02P12-SFP


RPH-03XLGE-QSFP+-S RPH-04P3/01P12-SFP
RPH-12XGE-SFP+-S RPH-08CP3-SFP
RPH-10XGE-SFP+-S RPH-08CP3-SFP-CES
RPH-08XGE16GE-SFP+-S RPH-04CP3-SFP
RPH-04CP3-SFP-CES
RPH-24CE1-DB50-120
RPH-24CE1-DB50-120-CES
RPH-24CE1-DB50-75
RPH-24CE1-DB50-75-CES

© ZTE Corporation. All rights reserved


M6000-S Line Interface Boards (1)

RPS-20GE-SFP

RPS-01XGE-SFP+

RPS-02XGE-SFP+

RPS-04P3/P12-SFP

© ZTE Corporation. All rights reserved


M6000-S Line Interface Boards (2)

RPU-01XLGE-CFP

RPU-01CGE-CFP

RPH-03XLGE-QSFP+-S

RPH-01CGE-CFP-S

© ZTE Corporation. All rights reserved


M6000-2S Line Interface Boards (1)

RPN-01XGE-SFP+-S

RPN-02XGE-SFP+-S

RPN-01P192-SFP+

RPN-02P192-SFP+

© ZTE Corporation. All rights reserved


M6000-2S Line Interface Boards (2)

RPN-24CE1-DB50-75

RPN-24CE1-DB50-75-CES

RPN-24CE1-DB50-120

RPN-24CE1-DB50-120-CES

© ZTE Corporation. All rights reserved


Contents

 ZXR10 M6000-S/M6000-2S System Structure


 Product Overview
 Boards

 Power Supply Module

 Heat Dissipation System

 ZXR10 M6000-S/M6000-2S Features and


Capacity
 ZXR10 M6000-S/M6000-2S Network Application
ZXR10 M6000-S DC Power Supply Module -1

-48 V RTN
Power supply input (+)
Switch power supply Handle
cable input
Indicator end

Setscrew -48 V input (-)


power supply
cable input end
© ZTE Corporation. All rights reserved
ZXR10 M6000-S DC Power Supply Module -2

 ZXR10 M6000-S DC power supply panel indicators description


Indicator Color Description

RUN Green It is always on when the system is operating properly.

ALM Red It is always on in the following situations:


•The breaker is open.
•Overvoltage or undervoltage occurs.

 ZXR10 M6000-S DC power supply Technical Specifications


Parameter Description

Dimensions (L × W × H) 213 mm × 84 mm × 111.84 mm

Weight 1.2kg

Rated input voltage -48 V DC / -60 V DC

Input voltage range -38 V DC – -72 V DC

Maximum input current 60A

Maximum output 2650W


Power

Rated input current 55A

© ZTE Corporation. All rights reserved


ZXR10 M6000-S AC Power Supply Module - 1

Switch Handl
e

Power supply Setscrew


input
connector
© ZTE Corporation. All rights reserved
ZXR10 M6000-S AC Power Supply Module - 2

 ZXR10 M6000-S AC power supply panel indicators description


Indicator Color Description

RUN Green It is always on when the system is operating properly.

ALM Red It is on when the power supply output is abnormal.

 ZXR10 M6000-S DC power supply Technical Specifications


Parameter Description
Dimensions (L × W × H) 526.2 mm × 197.2 mm × 41.2 mm
Weight 2.5kg
Input voltage range 100VAC- 240 V AC
AC input frequency 50/60Hz
Rated output power 1337.5 W / 2675 W
Rated output voltage -53.5V
Rated output current 50A

© ZTE Corporation. All rights reserved


M6000-8S DC Power Supply

 The maximum power


provided by each ZXR10
M6000-8S DC power supply
module is 2650 W
 There are two areas on the
M6000-8S backplane. Each
area is provided with one
channel of power supply.
Each area supports 1+1
redundancy backup.

© ZTE Corporation. All rights reserved


M6000-18S DC Power Supply

 ZXR10 M6000-18S supports N+1 or N+N redundancy for the DC power supply modules.

N+1 Power Supply N+N Power Supply


© ZTE Corporation. All rights reserved
M6000-2S DC Power Supply

Parameter Specification
Dimensions (Height × Width × Depth) 19.9 mm ×197.2 mm ×194.5 mm
Weight 0.9 kg
Rated input voltage -48 V DC / -60 V DC
Input voltage range -38.4 V DC to -72 V DC
Rated input current 28 A / 22.3 A
Rated output voltage -12 V DC / -48 V DC
Maximum output current 43 A / 20.3 A
Maximum output power 516 W / 780 W

© ZTE Corporation. All rights reserved


Contents

 ZXR10 M6000-S/M6000-2S System Structure


 Product Overview
 Boards

 Power Supply Module

 Heat Dissipation System

 ZXR10 M6000-S/M6000-2S Features and


Capacity
 ZXR10 M6000-S/M6000-2S Network Application
Heat Dissipation System Overview

 The heat dissipation system of ZXR10 M6000-8S:


 Fan modules (five)
 Air filter (two)

 The heat dissipation system of ZXR10 M6000-5S:


 Fan module(three)
 Fan in power supply module
 Air filter(one)

 The heat dissipation system of ZXR10 M6000-3S:


 Fan module(two)
 Fan in power supply module
 Air filter(one)

 The heat dissipation system of ZXR10 M6000-18S:


 Fan modules (twelve)
 Fan in power supply module
 Air filter (three)
© ZTE Corporation. All rights reserved
Heat Dissipation System – M6000-8S
Five fan modules, including
two fans and one fan
monitoring board in each
module

fan modules
Horizontal Air Filter

ZXR10 M6000-8S Air Directions

Air Filter
© ZTE Corporation. All rights reserved
ZXR10 M6000-S Fan Module
Indicators on the ZXR10 M6000-5S Fan Module Panel

Indicator Color Description

RUN Green It is on when the fan module is


operating properly.
ALM Red It is on when any fan of the fan
module has a fault.

Technical Specifications of the ZXR10 M6000-5S Fan Module

Parameter Description

Dimension(L×W×H) 217.3 mm × 84 mm × 99.45 mm


1. Lever 2. Indicator 3. Clasp
Weight 1.3 kg

Power consumption 22 W
Maximum wind
410 Pa
pressure
Maximum air volume 300 cfm

Maximum noise 73dB


Working voltage
-72 V – -36 V
range

© ZTE Corporation. All rights reserved


Heat Dissipation System – M6000-8S
Air Filter Replaced

© ZTE Corporation. All rights reserved


Heat Dissipation System – M6000-5S/3S DC

Air Filter

M6000-5S/3S Air Directions

Air Filter
Replaced
© ZTE Corporation. All rights reserved
Heat Dissipation System – M6000-5S/3S AC

System air duct

Air Filter
Each AC power supply module
has two fans for independent
heat dissipation.

M6000-5S/3S Air Directions

Air Filter
Replaced
© ZTE Corporation. All rights reserved
Heat Dissipation System – M6000-18S

Air Directions
of Network
Processing
Board Slots

© ZTE Corporation. All rights reserved


Heat Dissipation System – M6000-18S

Air Directions of
SFU Board Slots

© ZTE Corporation. All rights reserved


Heat Dissipation System – M6000-18S

Air Directions of
Power Supply
Module Slots

© ZTE Corporation. All rights reserved


Heat Dissipation System – M6000-2S
Air Directions of the ZXR10 M6000-2S10 Chassis

Air Directions of the ZXR10 M6000-2S4 Chassis

© ZTE Corporation. All rights reserved


Contents

 ZXR10 M6000-S/M6000-2S System Structure


 Product Overview
 Boards

 Power Supply Module

 Heat Dissipation System

 ZXR10 M6000-S/M6000-2S Features and


Capacity
 ZXR10 M6000-S/M6000-2S Network Application
ZXR10 M6000-S Features

 Broadband Multi-Service Integration Platform


 Product positioning: core and aggregation layers of carrier
backbone network, MAN service gateway, Core of large campus
network.
 Scalable switching capacity and high speed forwarding capability
 Various service accesses
 Carrier-class reliability
 Complete security guarantee
 Graphical integrated network management system

© ZTE Corporation. All rights reserved


ZXR10 M6000-S Features (Cont.)

 Layer 2 functions
 VLAN /QinQ /Super VLAN /MAC /Smartgroup /LACP/Broadcast restriction
/ARP/IGMP Snooping /Ethernet OAM

 Layer 3 functions
 IPv4/IPv6/ PIM-SM/PIM-DM/ IGMP

 MPLS
 MPLS L2 VPN /MPLS L3 VPN /MPLS TE / MPLS OAM

 QoS
 Traffic Classification/Traffic Monitoring and Shaping/Congestion
management/Congestion avoidance/
 H-QoS/QPPB

© ZTE Corporation. All rights reserved


ZXR10 M6000-S Features (Cont.)

 Integrated BRAS and SR services, Unified Service Edge


 RADIUS / Tacacs+/ DHCP Server/ DHCP Relay/ DHCP Snooping

 Reliability
 MPLS-TE tunnel end to end path protection/ MPLS-TE FRR/ BFD/VPN FRR/ IP
FRR/ LDP FRR/ Graceful Restart/ VRRP / NSR / Non interrupted upgrade

 Security
 MPLS tunnel /GRE tunnel /IPsec tunnel
 Anti attack /CPU Security / Advanced security features

 OAM

© ZTE Corporation. All rights reserved


Contents

 ZXR10 M6000-S/M6000-2S System Structure


 ZXR10 M6000-S/M6000-2S Features and
Capacity
 ZXR10 M6000-S/M6000-2S Network
Application
IP/MPLS Backbone Physical topology
•Dual-device per PoP
Logical topology •Core PoP full-mesh
• Dual-plane redundancy Eliminate single-point fault
and load-sharing
Increase HA

Site1
PE/
PE&CE

Site2
CE
Site3

© ZTE Corporation. All rights reserved 97


Full-service Bearer Network

Backbone IP Backbone MGW


MSCS
GGSN

Access control layer


of WCN

CR CR
CMS center
IP MAN BSC
RNC
Core layer
BRAS
M6000-S Access control
SR SR layer of RAN

Access layer

CE/PTN
Switch xDSL PON

Video Business
Wimax WLAN HSI surveillance IPTV Node B BTS Leased Line
Resident Service Carrier-grade and Leased Line Services

© ZTE Corporation. All rights reserved


Fixed Line NGN in MAN
SoftSwitch
core/gateway
router PE-ASBR
PSTN

TG/SG
VoIP VPN

Scheme A Scheme B
M6000-S M6000-S

VRRP EBGP/Static

M6000
L2 switch
VRRP

AG AG AG AG AG

 Carrier protect via VRRP+BFD


 High-density GE port save investment
 Guaranteed QoS

© ZTE Corporation. All rights reserved


Mobile Access in MAN
core/gateway
router
MPLS/VPN

WCN Site
switch

CS PS BOSS &
Application
 Mobile service SLA guarantee via VPN QoS
 Tunnel mode in RFC 3270: uniform, short pipe and pipe modes
 Flexible mapping
 Traffic engineering

 Carrier grade HA via FRR+BFD


 BFD with everything
 LDP/IP/TE/VPN FRR
© ZTE Corporation. All rights reserved

You might also like