You are on page 1of 6

Power solutions

> X & S series product range

Fully integrated, reliable and efficient


Dependable service, engineering expertise and parts support

Our energy working for you.TM


With over 80 years experience in
power generation and an extensive
global distributor network across
130 countries, we are ready to
match the right generating, transfer
and control technologies with your
power needs - be it continuous,
prime, peaking, standby,
cogeneration, or a complete
turnkey power plant.

Part of Cummins Inc. which has a


turnover of over US$ 11 billion,
Cummins Power Generation has
the global resources to meet your
unique power needs.

Global leader
Contents Global strengths, local partnership
Diesel generator sets -15 to 70 kVA............................. 3 With a worldwide distribution network across 130
Enclosures .................................................................... 4 countries, with approaching 500 dealers and 4,500
PowerCommand® and Power electronics .................... 5 service/ parts outlets, we have the capability and
experience to support our products wherever they are
operating.
Fully integrated – reliable – efficient
Cummins Power Generation is a world leader in the As a Cummins Power Generation user, you can expect
design and manufacture of pre-integrated generator a face to face relationship with someone worthy of
sets, transfer switches, paralleling equipment and your trust and fast access to reliable service,
controls for use in standby, prime and continuous rated engineering expertise and parts support.
systems.
Service outlets are spread strategically across the
All major components – the engine, alternator and world with technicians trained to the highest
control systems – are manufactured by divisions of standards. So wherever you need fully integrated,
Cummins. This integral approach means each element reliable and efficient power, call your local Cummins
of a generating set is designed to work in harmony Power Generation distributor.
from the start. A high quality product, coupled with
unrivalled reliability, gives industry leading power
solutions.
3

Cummins engine maintenance,


powered generating sets replacement and
are available at overhaul parts, thereby
competitive prices and proving to be the most
offer the best fuel economical power
economy, best warranty solution.
terms and lowest cost of

Diesel generator sets - 15 to 70 kVA


Cummins powered X and S series diesel generator sets are available in size ranging from 15 to 70 kVA. A high
quality product, manufactured in accordance with the international standards, coupled with unrivalled
reliability gives industry leading power solutions.

X series 50 Hz rating
Genset model Engine model Prime Standby
X series Ready-to-Use generator sets with 2 and 3
kVA / kW kVA / kW
cylinder inline configuration diesel engines are the
most compact, light weight and easy to service ES 17 D5 X 1.7 G1 15 / 12 16.5 / 13
products. Built-in vibration mounts, a completely ES 22 D5 X 2.5 G1 20 / 16 22 / 18
wired control system including engine protection, ES 28 D5 X 2.5 G2 25 / 20 27.5 / 22
instrumentation, industrial silencer and integral fuel
tank are part of its special features. Engines in this 60 Hz rating
series are naturally aspirated, fuel efficient, with low Genset model Engine model Prime Standby
lube oil consumption. kVA / kW kVA / kW
ES 12 D6 X 1.7 G2 13.5 / 11 15 / 12
ES 16 D6 X 2.5 G4 18 / 14.5 20 / 16
ES 20 D6 X 2.5 G4 22.5 / 18 25 / 20

* Alternator Model/Frame size are subject to change without notification.


Please verify this at the time of order .
60 Hz models are Tier 2 certifiable.
Rating Definition:
Prime Power
Prime Power is available for an unlimited number of annual operating hours in variable load applications,
in accordance with ISO8528-1.
A 10% overload capability is available for a period of 1 hour within 12-hour period of operation,
in accordance with ISO3046-1.
Standby Power Rating
Standby Power Rating is applicable for supplying emergency power for the duration of a utility power
interruption.No overload,utility parallel or negotiated outage operation capability is available at this rating.
In installations served by unreliable utility sources (where outages last longer or occur more frequently),where
operation is likely to exceed 200 hours per year, the prime power should be applied.All ratings are based on the
following reference conditions:Ambient temperature - 27oC (Altitude above sea level - 150 metres) Relative
humidity - 60%

S series 50 Hz rating
Genset model Engine model Prime Standby
The S series generator sets with 4 cylinder inline
kVA / kW kVA / kW
configuration diesel engines are naturally aspirated,
turbocharged and aftercooled. Engines in this series ES 33 D5 S 3.8 G2 30 / 24 33 / 26
are simple, compact, reliable, fuel efficient and have ES 38 D5 S 3.8 G3 35 / 28 38 / 30
minimal noise and vibration levels. ES 43 D5 S 3.8 G4 40 / 32 43 / 35
ES 55 D5 S 3.8 G6 50 / 40 55 / 44
ES 68 D5 S 3.8 G7 62 / 50 68 / 55

60 Hz rating
Genset model Engine model Prime Standby
kVA / kW kVA / kW
ES 30 D6 S 3.8 G2 35 / 28 38 / 30
ES 35 D6 S 3.8 G3 40 / 32 43 / 35
ES 38 D6 S 3.8 G4 43 / 35 47 / 38
ES 48 D6 S 3.8 G6 55 / 44 60 / 48
ES 61 D6 S 3.8 G7 70 / 56 76 / 61
4

Enclosures

All Cummins Power Generation diesel generator sets up to 70 kVA are available with weather
protective and sound attenuated enclosures.

All enclosures cover and protect the generator set. Enclosures are designed to optimize genset
cooling performance, providing you with confidence that genset ratings and ambient capability
have not been compromised. All enclosures provide easy access to service points and provide
operators with plenty of room for maintenance.

All sound attenuated enclosures are made of


1.6/2 mm thick CRCA sheets and structural
sheet metal base frame painted in Munsel
green shade. The walls of the enclosure are
insulated with fire retardant foam so as to
comply with the 80 dBA at 1 mtr sound levels.
All enclosures are designed to provide optimal
genset performance and sound-treatment. This
results in achieving the lowest noise level pos-
sible without compromising performance.

X series - 50 & 60 Hz ratings


Genset model Length Width Height Weight Sound level @ 100% load
(mm) (mm) (mm) (kgs) dry dBA dBA LWA
@ 1 mtr @ 7 mtr
ES 17 D5 1850 900 1375 810 80 63 96
ES 22 D5 1850 900 1375 860 80 63 96
ES 28 D5 1850 900 1375 885 80 63 96
ES 12 D6 1850 900 1375 810 80 63 -
ES 16 D6 1850 900 1375 840 80 63 -
ES 20 D6 1850 900 1375 860 80 63 -

Major features include:

● 80 dBA at 1 mtr
● Compact footprint, low profile design
● Easy access to all major generator, engine
control components for servicing
● Enclosed, protective exhaust systems
● CE compliant

S series - 50 & 60 Hz ratings


Genset model Length Width Height Weight Sound level @ 100% load
(mm) (mm) (mm) (kgs) dry dBA dBA LWA
@ 1 mtr @ 7 mtr
ES 33 D5 2300 1100 1650 1200 80 63 97
ES 38 D5 2300 1100 1650 1200 80 63 97
ES 43 D5 2300 1100 1650 1250 80 63 97
ES 55 D5 2300 1100 1650 1300 80 63 97
ES 68 D5 2300 1100 1650 1350 80 63 97
ES 33 D6 2300 1100 1650 1200 80 63 -
ES 38 D6 2300 1100 1650 1200 80 63 -
ES 43 D6 2300 1100 1650 1250 80 63 -
ES 55 D6 2300 1100 1650 1300 80 63 -
ES 68 D6 2300 1100 1650 1350 80 63
5

PowerCommand® and
Power electronics

PCC 0300 PCC 1301

Main features Model Main features Model Main features Model


PCC 0300 PCC 1301 PCC 0300 PCC 1301 PCC 0300 PCC 1301

General Engine protection Power transfer function

Integrated electronic Low fuel level Open transition transfer


governing High fuel level Hard closed transition
High oil temperature Soft closed transition
Human machine interface
Low engine coolant temp. (ramping)
Integrated AVR
Failure to crank shutdown Transfer & base load (utility)
Manual start / stop
Over crank (failure to start) Gen / mains breaker control
Auto / remote start
Over speed Gen / mains breaker status
Test run - manual
Low battery voltage alarm
Test run - auto Miscellaneous
High battery voltage alarm
Emergency stop Operating temperature range
Battery alternator charge fault
Alpha / numeric Screen -40oC to +70 o C
Discrete status indicators Alternator protection CE marked
Fault reset Under over frequency Common fault alarm
Reverse power CAN bus
Engine measurements/ instrumentation
Reverse VAr RS232
Oil pressure Date and time stamp
Overcurrent
Oil temperature for alarm
Short circuit
Water temperature LonWorks
Earth leakage
Engine speed
Phase sequence
Hours run
Number of starts Paralleling capacity Standard
Battery voltage Auto synchronising Not available
Exhaust temperature (isolated bus) Option
Isochronous kW & VAr Under frequency only
Alternator measurements/ instrumentation
load sharing control
3 phase voltage Auto synchronising (utility bus)
& frequency Based load (utility bus)
3 phase current Synchroscope
kWh Peak lopping
Total kVA
Total kW & kVAr
PF
Per phase kVAr, kW
Per phase kVA

GTEC

GTEC series transfer switches covering the range 40 to 1250 amps - provide
normal and generator set source monitoring, generator set starting, and load
transfer functions for emergency, standby, and optional standby applications.
GTEC transfer switches are continuously rated, so they can be applied in
applications up to their nameplate rating.

The transfer switch power contacts are silver alloy composition with high
pressure design that can withstand thousands of switching cycles without
burning, pitting or welding. They require no routine contact maintenance and provide 100%
continuous current ratings.

The transfer switch control is reliable and easy to understand, utilizing LED lamps for status
indications, and push-button controls for operator functions. The control is field-programmable
without the use of service tools.
Asia Pacific China India Mexico
10 Toh Guan Road 8 Wanyuan Street 35A/1/2, Erandawana Eje 122 No. 200
#07-01 Beijing Economic and Pune 411 038 Zona Industrial
TT International Tradepark Technological Dev. Area India San Luis Potosí, S.L.P.
Singapore 608838 Beijing 100176 Phone: 91 020 6602 7525 78090
Phone: 65 6417 2388 P.R. China Fax: 91 020 6602 8090 Mexico
Fax: 65 6417 2399 Phone: 86 10 6788 2258 Phone: 52 444 870 6700
Fax: 86 10 6788 2285 Latin America Fax: 52 444 824 0082
Brazil 3350 Southwest 148th Ave.
Rua Jati, 310, Cumbica Europe, CIS, Suite 205 North America
Guarulhos, SP 07180-900 Middle East and Africa Miramar, FL 33027 1400 73rd Ave. NE
Brazil Manston Park USA Minneapolis, MN 55432
Phone: 55 11 2186 4195 Columbus Ave. Phone: 954 431 5511 USA
Fax: 55 11 2186 4729 Manston Ramsgate Fax: 954 433 5797 Phone: 763 574 5000
Kent CT 12 5BF Toll-free: 877 769 7669
United Kingdom Fax: 763 574 5298
Phone: 44 1843 255000
Fax: 44 1843 255902

Visit us at
www.cumminspower.com

Our energy working for you.TM


www.cumminsindia.com
© 2006 Cummins Power Generation is a registered trademark of Cummins Inc.
PowerCommand® and Our energy working for you.™ are trademarks of Cummins Power Generation.
Cummins is a registered trademark of Cummins Inc. All other trademarks are owned by their respective companies.
Specifications are subject to change without notice. PGBU/01/Power Solutions/90deg./February 2007

You might also like