Production Gamma Ray (PGR)

Measures naturally occurring radiation emitted


by formations to determine lithology

Application The Sondex Production Gamma telemetry tool. The detector


Ray (PGR) tool measures the is temperature compensated
• Make depth correlations with
naturally occurring radiation to minimise drift from the
other logs
that is emitted by various photomultiplier tube.
• Determine formation profiles formations to determine
When calibrated, the difference
• Estimate shale content in lithology. Radioactive scale
between background and
reservoir rocks can also be detected.
calibrator levels establish a
• Delineate stratigraphic All PGR tools are compact, ratio between raw counts and
boundaries for several rugged and combine excellent API units, allowing a calibrated
production logs sensitivity with high resolution. display to be presented on the
Gamma rays are detected by log in API units.
• Identification of radioactive scale
a Sodium Iodide scintillation
• Tracer monitoring crystal, amplified and counted,
then sent to the appropriate
Features
• Combinable with other
Specifications
Sondex Ultrawire™ production
logging tools PGR032 PGR020

• Also available in Dualconn Temperature rating 350ºF (177ºC)

version (1 11/16 in. tools only) Pressure rating 15,000 psi (103.4 MPa)

Tool diameter 1 11/16 in. (43 mm)

Tool length 23.1 (586 mm)

Tool weight 9.4 lb (4.3 kg)

Toolbus Ultrawire production logging tool

Current consumption 20 mA

Sensor measure point 6.45 in. (163.7 mm) 5.3 in. (134 mm)

Sensitivity (nominal) 1 count per API

Materials Corrosion resistant throughout

bakerhughes.com Copyright 2020 Baker Hughes Company. All rights reserved. 82586