STAMP:

LEFT RIGHT

MATCH

LINE
1
7.10
AD1-10

T.O. HIGHEST PARAPET

2'-0"

2'-0"
4 T.O. PARAPET

5'-2"
AD4-02

4'-1"
6.9

T.O. PL 1
AD2-10 T.O. RF

1"
2'-52
T.O. PL

T.O. WDW

6.10

11'-1"
6.11

9'-1"
8'-0"
3
7.4 AD4-02

T.O. SHTG

7.3 7.7 7.3


T.O. PL
MAYFAIR

39'-0"
LOTS 4 & 10
T.O. WDW

10'-1"
BUILDINGS 4-6
5.6 11
AD4-02 10
1

8'-0"
AD5-10
AD5-10

5.27 5.27 T.O. SLAB

T.O. PL

6"

3"
EQ.EQ.
T.O. DR

08-12-2020 - 2019 CODE UPDATE BUILDINGS 4-6


OAKWOOD COMMUNITES, INC.
7.12 EQ. EQ.

64 MAXWELL

8"
9'-47
IRVINE, CA 92618

8'-0"

8'-0"
PHONE: (949) 719-9040

8'-6"
FAX: (949) 861-8696

T.O. CURB/SLAB
1"
22

1 1 4
3.2 8.1 AD4-01 7.4 3.2 AD3-10 5.2 AD4-01 5.26 2.2
MATCH

LINE

600-109 600-110
LEFT RIGHT UNIT 2 UNIT 3
BUILDING DEPARTMENT SUBMITTAL:
9th SUBMITTAL 09/05/2018
WEST ELEVATION BLDG 5 10th SUBMITTAL 09/25/2018
SCALE: 1/4" = 1'-0"
11th SUBMITTAL 10/16/2018
12th SUBMITTAL 12/21/2018
13th SUBMITTAL 02/06/2019
REVISIONS:

PROJECT DIRECTOR: EB, NC, JM


6.8 8.5
JOB CAPTAIN:
6.8
SENIOR ASSOCIATE: SA
ASSOCIATES: HK, MG, RK
8'-0"
8'-0"

PROJECT NUMBER: 15020


PROJECT CAD FILE: 15020_A5_A5-07
5
AD2-10 5 6.7
6.7
AD2-10 SHEET TITLE:

BUILDING 5
7
WEST SOUTH AD3-10 AD3-10

UNIT 2 UNIT 3
ELEVATION DECK BLDG 5
SCALE: 1/4" = 1'-0"
ELEVATION DECK BLDG 5
SCALE: 1/4" = 1'-0"
ENLARGED
EXTERIOR
ELEVATIONS
5. METALS 7.6 STUCCO RECESS 16. ELECTRICAL 1. HORIZONTAL AND VERTICAL DIMENSIONS SHOWN 9. ALL STRUCTURAL MEMBERS AND ELEMENTS ARE
SYMBOL LEGEND: 5.2 C.R. STUCCO WEEP SCREED, TYP 7.7 STUCCO OVER FOAM SHAPE 16.1 ELECTRICAL WALL FIXTURE 'S5' OR 'S6' PER SITE ARE FROM FACE OF STUD, FACE OF CONCRETE, SHOWN FOR REFERENCE ONLY REFER TO ROBERT HIDEY ARCHITECTS, INC. © 2020 - ALL RIGHTS
5.6 WROUGHT IRON GUARD, 42" HIGH MIN. LIGHTING DRAWINGS BY OTHERS. TOP OF OR FACE OF CMU, UNLESS NOTED OTHERWISE STRUCTURAL ENGINEERS DRAWINGS FOR RESERVED THE DRAWINGS, DESIGNS, INFORMATION,
XX KEY NOTE
5.10 NOT USED 7.9 STUCCO OVER HIGH DENSITY FOAM FIXTURE AT +96" AFF (U.N.O.). VERIFY 'J' BOX DESIGN, DETAILS AND DIMENSIONS. CONTENT AND PROCEDURES DESCRIBED HEREIN ARE
5.19 C.R. METAL OVERFLOW / SCUPPER SURROUND LOCATION WITH MANUFACTURES 2. ANY DISCREPANCY FOUND IN THESE DRAWINGS FOR THE EXCLUSIVE USE OF ROBERT HIDEY
1. SPATIAL
5.20 C.R. METAL DRAIN PIPE OUTLET 7.10 STUCCO OVER FOAM WALL CAP, SLOPE AWAY SPECIFICATIONS TO BE BROUGHT TO THE ATTENTION OF THE 10. CONTRACTOR TO COORDINATE PLUMBING, ARCHITECTS, INC., OR AFFILIATES, AND, AS SUCH, ARE
1.1 LINE OF WALL BEYOND.
5.22 C.R. METAL TRELLIS FROM BLD'G 1/2" PER FT. MIN. 16.2 ENTRY LIGHT FIXTURE 'S7' PER SITE LIGHTING ARCHITECT PRIOR TO ANY CONSTRUCTION MECHANICAL, ELECTRICAL PENETRATIONS AND NOT TO BE REPRODUCED IN ANY FORM OR MEDIA,
1.2 OPENING IN WALL. REFER TO ELEVATION FOR CURRENT OR FUTURE, OR DISCLOSED TO OTHERS
5.23 WROUGHT IRON BALCONY 7.12 STUCCO WRAPPED FOAM CORBEL DRAWINGS BY OTHERS. TOP OF FIXTURE +96" CONNECTIONS WITH SUBCONTRACTORS.
DETAIL REFREN WITHOUT THE WRITTEN CONSENT OF ROBERT HIDEY
5.24 C.R. METAL DRAIN PIPE OUTLET AFF (U.N.O.). VERIFY 'J' BOX LOCATION WITH 3. FIRST FLOOR DIMENSIONS ARE TOP OF SLAB OR
2. SITE CONSTRUCTION 7.13 STUCCO OVER FOAM ROOF CORNICE MANUFACTURERS SPECIFICATIONS ARCHITECTS, INC. DISTRIBUTION OR DUPLICATION OF
5.25 C.R. METAL AWNING TOP OF SUB FLOOR SHEATHING MATERIAL. 11. FINISH CARPENTER SHALL FIELD VERIFY ALL
2.1 SITE WALL (PER LANDSCAPE DWGS) 7.14 STUCCO AWNING 16.3 LIGHTED ADDRESS SIGN, +64" AFF (U.N.O.) THESE DOCUMENTS IS NOT TO BE CONSTRUED AS
5.26 C.R. METAL GAS METER SCREEN - SHUTTER SIZES WHERE THEY OCCUR. (NOT USED) PUBLICATION IN DEROGATION OF THESE RIGHTS.
2.2 FINISH GRADE (PER CIVIL DWGS) RE: LANDSCAPE DWGS 7.15 PRECAST CONCRETE TRIM SURROUND AT UNIT SWITCHED BY PHOTOCELL 4. SECOND FLOOR DIMENSIONS ARE TOP OF SUB VISUAL CONTACT WITH THESE DOCUMENTS SHALL
5.27 METAL TERMINATION CAP FOR TANKLESS W/H. ENTRY DOORS. FLOOR SHEATHING MATERIAL. 12. ALL EXTERIOR STUCCO PER COLOR CONSTITUTE EVIDENCE OF ACCEPTANCE OF THESE
3. CONCRETE RE: MANUFACTURER'S SPECIFICIATIONS CONSULTANT.
8. DOORS AND WINDOWS RESTRICTIONS.
3.1 CONCRETE SLAB ON GRADE (PER STRUCT 6. ALL EXTERIOR PAVING AND SITE ELEMENTS ARE
8.1 ENTRY DOOR W/ TEMP. GLASS PANEL
DWGS) 6. WOOD FOR REFERENCE ONLY REFER TO LANDSCAPE 13. EXTERIOR STUCCO CONTROL JOINTS SHALL BE
8.2 SECTIONAL ROLL-UP GARAGE DOOR SHEET NUMBER:
3.2 CONCRETE STOOP - REFER TO CIVIL 6.6 2x WOOD HEAD TRIM AND CIVIL DRAWINGS FOR DESIGN, DETAILS AND INSTALLED AT ALL WINDOW AND DOOR OPENINGS
8.3 HOLLOW METAL ACCESS DOOR
LANDSCAPE DRAWINGS 6.7 WOOD SILL TRIM DIMENSIONS. HORIZONTALLY ALONG HEADS AND VERTICALLY
8.4 FACTORY METAL LOUVER DOOR, SEE DR. SCHED.
6.8 2x WOOD TRIM 8.5 FRENCH DOOR WITH TEMP GLASS AT EDGES OF OPENINGS.

A5A5-07
4. MASONRY 6.9 4X WOOD HEAD TRIM 8.6 SLIDING GLASS DOOR WITH TEMP GLASS 7. ALL MECHANICAL EQUIPMENT, GRILLS AND
4.13 FALSE CLAY PAVER VENT 6.10 4X WOOD TRANSOM TRIM CONTROLS ARE FOR REFERENCE ONLY REFER TO
6.11 4X WOOD JAMB TRIM 9. MISCELLANEOUS MECHANICAL DRAWINGS FOR DESIGN, DETAILS
9.1 FALSE RECESSED VENT AND DIMENSIONS.
7. EXTERIOR FINISHES 9.3 BUILDING OR UNIT NUMBER SIGN, 12" MINIMUM
7.1 ROOFING MATERIAL. (REFER TO STRUCTURAL) CONTRASTING THE BACKROUND, ILLUMINATED 8. ALL ELECTRICAL FIXTURES, OUTLETS AND
7.2 3-COAT STUCCO (FINISH PER BUILDER) ALL HOURS OF DARKNESS FOR THE BUILDING EQUIPMENT ARE FOR REFERENCE ONLY REFER
7.3 STUCCO SOFFIT / CEILING AND FOR THE UNIT NUMBERS THEY ARE TO ELECTRICAL DRAWINGS FOR DESIGN, DETAILS PLOT REFERENCE DATE: 08/11/2020
7.4 STUCCO SILL, SLOPE 1/2" PER FT. MIN. REQUIRED TO BE A MINIMUM 6" VISIBLE FROM AND DIMENSIONS.