You are on page 1of 7

ANALISA BEBAN

RANGKA ATAP BAJA RINGAN


GEDUNG RAWAT INAP KELAS III ( FLAMBOYAN)
RSUD GROBOGAN JL DI PANJAITAN NO.36
PURWODADI

CV. SURYA MANDIRI


Jl. Industri V No. 234 Kaligawe
SEMARANG
Engineering Design Summary
Company GIGASTEEL Truss ID R6
Client RSUD DR R SOEDJATI [ GEDUNG FLAMBOYAN
System ] Giga-Galvalum
Job No SMG 081813 Design Code AS/NZS 4600:2005-S
Dwg No. QS CUTTING SMG 081813 GEDUNG RAWAT
Wind Speed
INAP KELAS IIIW30
[ FLAMBOYAN ] RSUD DR R SOEDJATI
Print Date 15-10-2018 Roof Load CONCRETETILE
Overall Status Passed Truss Spacing 1200
Overall Capacity 29% BC Restraint 2000
TC Restraint 350

Materials Used Z75.75,


Reactions Up (L>R) 1451,2626,1900,1391,609,0,55,132,
Reactions Dn (L>R) 2863,5243,4273,3372,2401,1365,1403,395,

Load Case Results

Load Case 1 1.0G 10% Load Case 8 1.2G + 1.5P 23%


Load Case 2 Ws 18% Load Case 9 1.2G + 1.5P 22%
Load Case 3 1.2G + 1.5Q 18% Load Case 10 1.2G + 1.5P 25%
Load Case 4 0.9G + Wu 25% Load Case 11 1.2G + 1.5P 29%
Load Case 5 1.2G + Wd 27% Load Case 12 1.2G + 1.5P 22%
Load Case 6 1.2G + 1.5P 21% Load Case 13 1.2G + 1.5P 28%
Load Case 7 1.2G + 1.5P 23%
Client = RSUD DR R SOEDJATI [ GEDUNG FLAMBOYAN ] Overall Status = Passed
Job No. = SMG 081813 System = Giga-Galv
Dwg No. = QS CUTTING SMG 081813 GEDUNG RAWAT INAP KELAS III [ FLAMBOYAN ] RSUD DR R SOEDJATI PURWODADI JL DI PANJAITAN NO.36 PURWODADI.dwg Truss
Print Date = 15-10-2018
1819

17

16

15

14

13

12

11

10

2 1000 0 1000
1

Relative Scale

Node Diagram for Load Case 11 (1.2G + 1.5P) - 29% of Full Capacity for this Load Case Only Software Licenced for Unlimited
Quik Series Framing Truss Analysis Report

Company Name GIGASTEEL


Job Name RSUD DR R SOEDJATI [ GEDUNG FLAMBOYAN ]
Job Number SMG 081813
Drawing Name QS CUTTING SMG 081813 GEDUNG RAWAT INAP KELAS III [ FLAM
Print date 15-10-2018

Truss Name R6
System Name Giga-Galvalum
Design Code AS/NZS 4600:2005-S
Status Passed

Node Results for Load Case 11 (1.2G + 1.5P)

Node IDplacementlacementesultantRotationReactionReactionReactionReactionint LoadCapacityShortage

1 -0.04 0.05 0.06 -0.02 0 0 0 0 0 0 0


2 0.00 0.00 0.00 -0.02 0 194 0 -292 0 0 0
3 0.06 -0.08 0.10 0.01 0 0 0 0 0 0 0
4 0.00 0.00 0.00 -0.00 0 334 0 -540 0 0 0
5 0.09 -0.12 0.15 0.00 0 0 0 0 0 0 0
6 0.01 0.00 0.01 -0.01 0 432 0 -648 0 0 0
7 0.15 -0.21 0.26 -0.01 0 0 0 0 0 0 0
8 0.01 0.00 0.01 0.03 0 235 0 -411 0 0 0
9 -0.13 0.20 0.23 0.02 0 0 0 0 0 0 0
10 0.02 0.00 0.02 -0.12 0 625 0 -880 0 0 0
11 0.64 -0.89 1.10 -0.25 0 0 0 0 0 0 0
12 1.48 -2.10 2.56 -0.27 0 0 0 0 130 0 -130
13 0.71 -1.00 1.22 0.30 0 0 0 0 0 0 0
14 0.02 0.00 0.02 0.20 0 590 0 -1144 0 0 0
15 -0.30 0.44 0.53 -0.03 0 0 0 0 0 0 0
16 0.01 0.00 0.01 -0.07 0 465 0 -575 0 0 0
17 0.33 -0.46 0.56 -0.01 0 0 0 0 0 0 0
18 0.01 0.00 0.01 0.09 0 137 0 -254 0 0 0
19 -0.04 0.07 0.08 0.09 0 0 0 0 0 0 0

Software Licenced for Unlimited Use Page 1


Client = RSUD DR R SOEDJATI [ GEDUNG FLAMBOYAN ] Overall Status = Passed
Job No. = SMG 081813 System = Giga-Galv
Dwg No. = QS CUTTING SMG 081813 GEDUNG RAWAT INAP KELAS III [ FLAMBOYAN ] RSUD DR R SOEDJATI PURWODADI JL DI PANJAITAN NO.36 PURWODADI.dwg Truss
Print Date = 15-10-2018

1000 0 1000

Relative Scale

Deflection Diagram for Load Case 11 (1.2G + 1.5P) - 29% of Full Capacity for this Load Case Only Software Licenced for Unlimited