ECT PROBE FREQUENCY SELECTION FOR DIFFERENT TUBE MATERIALS AND

THICKNESS
RFT PROBE DIAMETER SELECTION TABLE
TUBE DIAMETER TUBE WALL RIGID PROBE FLEXBLE PROBE
THICKNESS

MM INCH MM INCH Recommended Alternated Recommended Alternated


probe probe probe probe
diameter diameter

12.7 0.5 1.07 0.042 9.0 - - -

1.24 0.049 9.0 - - -

15.88 0.625 1.24 0.049 11.0 12.0 - -

1.65 0.065 11.0 10.0 - -

2.11 0.083 10.0 - - -

19 0.75 1.65 0.065 14.0 13.0 - -

2.11 0.083 13.0 12.0 - -

2.41 0.095 12.0 13.0 - -

2.77 0.109 12.0 11.0 - -

25.4 1.0 2.11 0.083 19.0 18.0 - -

2.41 0.095 18.0 19.0 - -

2.77 0.109 18.0 17.0 - -

3.05 0.12 17.0 - - -

3.40 0.134 16.0 17.0 - -

31.75 1.25 2.11 0.083 26.0 24.0 - -

2.41 0.095 24.0 - - -

2.77 0.109 24.0 - - -

3.05 0.12 22.0 24.0 - -

3.40 0.134 22.0 - - -


TUBE DIAMETER TUBE WALL RIGID PROBE FLEXBLE PROBE
THICKNESS

MM INCH MM INCH Recommended Alternated Recommended Alternated


probe probe probe probe
diameter diameter

38.1 1.5 2.11 0.083 30.0 32.0 - -

2.41 0.095 30.0 28.0 - -

2.77 0.109 28.0 30.0 - -

3.05 0.12 28.0 30.0 - -

3.40 0.134 28.0 - - -

50.8 2.0 2.11 0.083 - - 37.0 -

2.41 0.095 - - 34.0 37.0

2.77 0.109 - - 45.0 -

3.05 0.12 - - 45.0 -

3.40 0.134 - - 45.0 -

63.5 2.5 2.11 0.083 - - -

2.41 0.095 - - -

2.77 0.109 - - -

3.05 0.12 - - -

3.40 0.134 - - -

76.2 3.0 4.19 0.165 - - 55.0 -

5.16 0.206 - - 55.0 -

6.05 0.238 - - 55.0 -

88.9 3.5 5.16 0.206 - - 65.0 -

6.05 0.238 - - 65.0 -

7.21 0.284 - - 65.0 -

ECT PROBE DIAMETER SELECTION TABLE