You are on page 1of 13

Software

Process Documentation
Doc 001
MIS002-050 MIS for programming Version 10-May-18
of SANDS 1010 HS 8GB MRI Doc Date 1 of 13
Page

Table of Contents
1 Purpose________________________________________________________________2
2 Scope__________________________________________________________________2
3 Definition(s) & abbreviation(s)______________________________________________2
4 Reference(s)_____________________________________________________________2
5 MRI Preparation_________________________________________________________2
5.1 Prerequisites_______________________________________________________________2
5.2 Preparing MRI_____________________________________________________________3
5.3 Copying Files form MRI_____________________________________________________8
6 NOTE_________________________________________________________________11

ESL-SW-QF-23 Version 1.6 Internal Page 1 of 13


1 Purpose
Purpose of this document is to describe the steps for preparation of 8 GB Sands MRI .

2 Scope
The scope of this document is to mention about Preparing Sands 8 GB MRI and copy to / from
operation from MRI.

3 Definition(s) & abbreviation(s)


Name Description
MRI Meter Reading Instrument
HHU Hand Held Unit
BCS Base Computer Software
PC Personal Computer
Lincom PC end utility to transfer the data to/from MRI to/from PC
XX Version of Software

4 Reference(s)
Document No. BC
MRI User Manual Ver General specification of 8 GB Sands MRI
4.7.pdf
RNDIS- Lincom Driver Installation Doc
Installation.doc

5 MRI Preparation
The process of MRI preparation is very simple. Just select copy & paste the desired files in MRI
from PC. In this operation one utility called Lincom will execute at PC & USB cable is
connected between PC & MRI .Once they are connected the data can be transferred between
them.

5.1 Prerequisites
For programming the MRI with respective products like SMILE, following steps need to
perform (Here we are illustrating steps for Smile program, similar kind of steps to perform for
other programs like Dispupd, LibHHU etc).

a. Identify the latest released Smile program in release directory.


b. Copy “PROGRAM FILES” folder from “\\SANDS 1010 HS\PROGRAM FILES” to on local
drive.
c. Copy “For SANDS 1010 HS 8GB” folder on local drive
d. Now Follow the Instruction given in this document to transfer the data from PC to MRI.
e. At PC Lincom utility must be there. This utility is provided in the CD with every MRI pack
(Or copy setup from release directory – “\\SANDS 1010 HS\Lincom SANDS 1010 HS
8GB”). Copy Lincom setup on local drive & install the same on PC.

NPD_SW_QF_23 Version 003 Internal Page 2 of 13


NPD_SW_QF_23 Version 003 Internal Page 3 of 13
NPD_SW_QF_23 Version 003 Internal Page 4 of 13
f. Connect MRI with PC by USB cable and for communication between PC & MRI, USB
driver must be installed on PC, please install the same as per attached document

RNDIS-Installation.d
oc

If driver is already installed, no need to install it again.

5.2 Time set of MRI


Follows below steps to perform time set in MRI

1. Run the Lincom.exe at PC.


2. Connect MRI USB Port to PC USB port via provided cable
3. Press “SERIAL NUM” button to get actual MRI serial number to verify connectivity

NPD_SW_QF_23 Version 003 Internal Page 5 of 13


4) Click on “SET-VIEW DATE/TIME” button, we will get new screen

5) It will show current date & time of MRI


6) Select “Set Date Time” option & enter the current system date & time to be set in MRI
7) Click on set button

8) Press OK button

NPD_SW_QF_23 Version 003 Internal Page 6 of 13


9) Press OK button
10) MRI restarts & will get Date-Time successfully send message on Lincom GUI.
11) After MRI restart again press on “SET-VIEW DATE/TIME” button to ensure proper ate & time in
MRI.

12) Press cancel if proper date time reflects without any time drift.

5.3 Prepare MRI


Preparing of MRI means transferring the desired program files to MRI.

Follows below steps to prepare MRI

1. Press “Esc” button, then Prepare “SEMS” Folder in MRI in B: drive. To create the
specified folder write command “MD SEMS”. as shown below

NPD_SW_QF_23 Version 003 Internal Page 7 of 13


2. Run the Lincom.exe at PC.

3. Connect MRI USB Port to PC USB port via provided cable.

4. Click on “Serial No.” Button to get MRI Serial number.

5. Click on export button and select the both files from ‘For SANDS 1010 HS 8GB’
folder and copy to B:\ drive. As shown below

NPD_SW_QF_23 Version 003 Internal Page 8 of 13


6. Click on export button and select the path of PC where program files are available.
Select all files and Click on open button in “B:\SEMS\”.

NPD_SW_QF_23 Version 003 Internal Page 9 of 13


Click on “Ok” button.

Now restart the MRI:

Following two options will be available

1. Secure (DLMS / NON- DLMS) - To read secure make meters.

2. Tools - To get MRI serial no & to check battery & memory status of MRI

NPD_SW_QF_23 Version 003 Internal Page 10 of 13


Now Press key 1 and Enter. This will launch the SMILE on MRI. Following screen will
Occur in front of you.

NPD_SW_QF_23 Version 003 Internal Page 11 of 13


How to come back on Home Screen of MRI

Use “SH” command on MRI b:\drive.

Procedure to configure of MRI Menu –

Open the “mrimenu.mnu” in notepad++ or TextPad. Below screen will get Appear.

Write below Command Line in “mrinemu.mnu” file and Load into MRI “B:\drive”. And Now power OFF
and ON MRI.

NPD_SW_QF_23 Version 003 Internal Page 12 of 13


Note:-
1. For functional test refer RTP302-115
2. This model of Sands MRI does not support LPR reading

Versio Date completed Written by Reviewed By Approved By


n
001 10-May-2018 Kritesh Kumawat Dipak Kumar Shah Rajendra Jawa
SANDS 1010 HS 8 GB Dos based MRI Preparation.