installed at 45 degree and steps are not regular.handrail is unsafe
No lines for dumping and
cleaning pits . No water tank supply for cleaning .
two agitators in each pit.
Not enough for agitation and solids suspension . Impeller distance is 92 cm from bottom ( at higher position).blade length is 92 cm diameter . No gear box installed within agitator motors of green its
Top entering gate are closed
on green pits ( bolted )
Diesel tank without
containment dikes
Diesel tank without fuel
machine supplier. No fire extinguisher
Observed bottom of some
pits tanks are harshly corroded . Need to inspect thickness and the matter of pit walls and if it holds heavier mud weights
Discharge lines are all
tortious and 4'' size LMP INSPECTION REPORT Date :31/08/2021
Recommendation Current status Corrected status
Handrill has to be installed and should be at least 1.5 m height .
Ladders can be equipped with cages that act as
safety barriers which provide fall protection. If someone falls, the cage can help catch them.Fall Protection Systems - Ladders can also be equipped with a protection system that is comprised of a harness that connects to a lanyard. The lanyard is attached to a brake so that the harnessed worker can stop mid-fall.
Stairway should be installed at 39-45
degree.Between two regular steps standard distance is 9''-11''
Need to line up pits to nearby waste pit ( butter
fly valve connected to dump line ).Settled barite will be so difficult to discard it if cleaning pits sequences are postponed .Need water tank equipped with lines to clean pits whe needed
LMP pit is 70 m3 with 12m x 2.4 m ( lengthx
width ) . Since (length /width) ratio is more than 1.5 ( 12/4.2 = 5) , we need more than 2agitators to ensure good agitation and efficient . since impeller is canted and predominat flow is axial , Need to lower it at 30 cm from bottom to stear enough solids sediments . blade should be at least 1 m diameter and 20 cm width . Need to add gear box to agitator motors to achieve the desired speed-torque output ( a gearbox will be used to reduce the shaft speed of a motor and increase the torque)
these gates need to be accessible and openable
in order to monitor volumes and clean inside tanks
containment dikes save you money and ensure
your containment system is SPCC compliant (Spill Prevention, Control and Countermeasure)
Need to have such machine to provide vaccum
trucks and record daily diesel consumption . Fire extinguisher is a must .
As Standards thickness wall at least 8 mm mild
steel With proper coating .Spetial team should inspect and go in more such details for site safety issue .
Recommend use of centrifuge in LMP to remove
undesirable solids. Available duration in LMP will enhance centrifugation process.As a result always clean mud is sent to rigs
standards in mud pits states that discharge line
should be 6'' at straight line to prevent pressure loss and help hopper efficient circulation . Corrected status