You are on page 1of 3

PT ZI-TECHASIA

Wisma Budi Building 2F 202 Tel (62-21) 5296 1448/58/68


JL HR Rasuna Said Kav, C-6 Fax (62-21) 5296 1450/60/70
Jakarta 12940 E-mail: zi-techasia@zi-id.com
Indonesia Website: www.zitechasia.com

Product Application Inquiry Report

Product Doshion DCHR-71 ion exchange resin


Application Gold recovery, cyanide elution
Date of initial inquiry 02 March 2008
Date of final report 25 April 2008
Report prepared by J Wilson

Questions Answers
1 High mercury & sulphur. Will these be Mercury Removal resin
adsorped onto the resin? Is it possible
For mercury removal we recommend
to have a resin to avoid this?
specialty resin DCHR 76.
In addition to the above, they have silver
Removal of Sulphur and Arsenic
and arsenic. Will these be taken up on
the resin with the gold? Generally DCHR 71 removes Sulphur and
Arsenic up to some extent. But if the
concentration of Sulphur and Arsenic is
high, we recommend specialty resin DCHR
78.
Both these resins can be used upstream of
the DCHR 71 resin to remove these ions
first.
2 De-sorption & regeneration: On the Both stages are most important.
PDS for DCHR-71, it refers to the
In gold adsorption stage, the chloride ion
-De-sorption step (thiourea & sulphuric is replaced by Sulphate (Sulphur),
acid), and the Arsenate (Arsenic) and other metal ions.
-Regeneration step (sodium hydroxide, In de-sorption stage, H2SO4 converts the
sodium chloride). remaining Chloride ion in to Sulphate.
Our clients informed us that currently Now the ionic form of the resin is changed
they only carry out the which must be regenerated into chloride
thiourea/sulphuric acid de-sorption, form for further gold adsorption.
and do not use the sodium
If the resin is not regenerated, the
hydroxide/sodium chloride at any time.
operating efficiency will decrease and
Please comment on this and advise if eventually the resin will not perform so
both steps are required. well.
Therefore the resin must be regenerated
with NaOH and NaCl solutions to
exchange all Sulphate, Arsenate, other
metal ions into chloride ions.
Name

3 Desorption & regeneration 1- After desorption (thiourea & sulphuric


procedures: acid), rinse with DI water for 30
minutes. Flow rate shall be equal to
Some users are not familiar with the
desorption flow rate.
steps of desorption followed by
regeneration. They only perform the 2- Regenerate with 2% NaOH solution.
desorption as they don't use the caustic Use 60g of NaOH per litre of resin.
and sodium chloride for regen). Regeneration time is 30 minutes. Flow
rate to be adjusted accordingly i.e.
Please can you provide procedure for
3,000 ml NaOH should be passed
these steps (eg: concentration,
through one litre resin in 30 minutes
temperature, time etc) so they can
(100 ml/minute). Wash with DI water
understand it and ensure it is done
for 30 minutes at 100 ml/min.
correctly.
3- Regenerate with 100g/litre NaCl (5%
solution) i.e. for one litre resin, 100g
NaCl shall be used. 2000 ml to be
passed though resin in one hour (30-
35 ml/Min). Wash with DI water till
outlet water does not detect positive
test for chloride.
4 Product evaluation: Is there a standard Standard chemical and physical testing
laboratory method or pilot test method methods are available. A method for
to assist with the performance performance test is not available.
evaluation of the product with the
pregnant solution used on these specific
sites?

5 Life expectancy: Can you advise The life expectancy is about three years.
typical life expectancy range normally
experienced in this type of application?
6 References: Can you provide any So far the DCHR71 has not been used in
customer references citing experience industry applications. The supplier is
using the product in these applications prepared to offer this product at reduced
in other countries, and perhaps some price for industry evaluation purposes.
reference contacts (eg: metallurgist) that
they can contact to discuss how they
used?
7 Delivery: What is the lead time for this Pre-shipment sample can be prepared
product for samples & ordering? within 10 days time. A lead time of 6-8
weeks is required for commercial
shipment.
8 Uniform particle size: Other alternative Particle Size In ion exchange process,
products in current use have a particle surface area is very important parameter
size of 0.95mm (+/- 0.5mm) diameter. on which an ion exchange and adsorption
What is the size distribution of the take place.
DCHR 71 resin?
Surface area is directly related to effective
size of particle which is calculated from
particles size distribution. Particle Size
Distribution of DCHR 71 ranges from 0.6
to 1.4 mm which gives an effective median

Page 2 of 3
Name

size of 0.9mm (+ /- 0.5mm), which is


almost identical to the specification of the
quoted uniform particle size products.

End of report