You are on page 1of 2

Automatic Demineralisation

Plant
The latest INDION Auto Demineralisation (DM)
range comprises a family of automatic twin bed
deionisers incorporating state-of-the-art
counterflow ion exchange technology previously
available only in large, purpose-designed plant.

The operational cycle of these PLC controlled


service & regeneration, packaged units is based
on programmed time throughout, which is pre-
programmed into the PC according to the type of
feedwater. The ion exchange resins are never fully
exhausted ensuring optimum deionised water
production at all times.

Regeneration takes just 90 minutes - after a Special Features


minimum service cycle of six hours. As
regeneration of the cation and anion beds is - Instantaneous flow rate up to 25 m3/h
simultaneous, the effluent streams are largely self- - Maximum available output m3/day on a
neutralising, reducing waste disposal costs and feedwater of 100 ppm total anion feed.
environmental impact. - Average conductivity of purified water is
10.0 µS/cm (at 25oC) , with low running costs.
The Auto DM is exceptionally compact, and is - High chemical efficiency - high purified water
skid-mounted on a corrosion-resistant frame output from low regenerant chemical usage.
which also accommodates a stainless steel multi- - Compact skid mounted system.
purpose pump to optimise the performance of the - Stainless steel process pump fitted as
plant during service and regeneration. standard
- Operation control by PLC
- Continuous indication of system status
- Audible alarm and 'no flow' alarm circuit
Automatic DM Plant - Can be connected to level sensors in
chemical tanks to prevent regeneration when
The INDION Automatic DM Plant has been
insufficient chemicals are available
designed to provide purified water that meets the
- High level treated water tank alarm to
rigorous requirements of the American, British
prevent overflow and to trip the system.
and European Pharmacopoeias. Incorporating
- Minimal installation and commissioning cost
resins specially selected for high purity
- Low bacterial contamination/growth
applications, the system produces deionised water
- Operator interface makes the system user
having a conductivity < 10.0 µS/cm (at 25oC) to
friendly.
meet the industry requirements.
Bulletin CD

Technical Data

Flow Rates Working Pressure Regenerants Flow Rates Working Pressure Regenerants
CATION Inlet/Outlet Hydrochloric Sodium
UNIT Min Max Min Max ANION Inlet/Outlet Min Max Min Max Hydroxide
Connections Acid 100% UNIT Connections 100%
mm m³/h m³/h kg/cm²g kg/cm²g kg mm m³ /h m³ /h kg/cm²g kg/cm² g kg

SAC HQ1 32 1.0 3.5 2.0 3.5 4.5 SBA HQ1 32 1.0 3.5 2.0 3.5 4.5
SAC HQ2 32 1.0 4.0 2.0 3.5 6.0 SBA HQ2 32 1.0 4.0 2.0 3.5 6.0
SAC HQ3 32 1.0 5.0 2.0 3.5 9.0 SBA HQ3 32 1.0 5.0 2.0 3.5 9.0
SAC HQ4 32 1.0 5.0 2.0 3.5 12.0 SBA HQ4 32 1.0 5.0 2.0 3.5 12.0
SAC HQ51 32 1.5 5.0 2.0 3.5 15.0 SBA HQ51 32 1.5 5.0 2.0 3.5 15.0
SAC HQ52 50 1.5 10.0 2.0 3.5 15.0 SBA HQ52 50 1.5 10.0 2.0 3.5 15.0
SAC HQ61 32 2.0 5.0 2.0 3.5 24.0 SBA HQ61 32 2.0 5.0 2.0 3.5 24.0
SAC HQ62 50 2.0 10.0 2.0 3.5 24.0 SBA HQ62 50 2.0 10.0 2.0 3.5 24.0
SAC HQ7 63 3.0 10.0 2.0 3.5 37.5 SBA HQ7 63 3.0 10.0 2.0 3.5 37.5
SAC HQ8 63 4.0 15.0 2.0 3.5 48.0 SBA HQ8 63 4.0 15.0 2.0 3.5 48.0
SAC HQ9 63 6.0 15.0 2.0 3.5 60.0 SBA HQ9 63 6.0 15.0 2.0 3.5 60.0
SAC HQ10 63 7.0 15.0 2.0 3.5 78.0 SBA HQ10 63 7.0 15.0 2.0 3.5 78.0

Average Treated Water Quality


pH : 7.5 - 9.5
Electrical conductivity at 20oC : 10 - 30 microsiemens/cm
Residual electrolyte : 2.0 - 5.0 mg/l
Note : 1. Feed water should be free from turbidity, organic matter, heavy metals, free chlorine and oil and design parameters based on 25oC
2. Output between regeneration will vary with influent feed water quality.

To the best of our knowledge the information contained in this publication is accurate. Ion Exchange (India) Ltd. maintains a policy of
continuous development and reserves the right to amend the information given herein without notice. Please contact our regional offices for
current product specifications.

is the registered trademark of Ion Exchange (India) Ltd.

CORPORATE OFFICE MUMBAI


Tiecicon House, Dr. E. Moses Road, Mahalaxmi, Mumbai 400 011. Tiecicon House, Dr. E. Moses Road, Mahalaxmi, Mumbai 400 011.
Tel: 022-2493 9520/23/25 Fax: 022-2493 8737 Tel: 022-2493 9520/23/25 Fax: 022-2493 8737
E-mail: ieil@ionexchange.co.in; hocro@ionexchange.co.in E-mail:hocro@ionexchange.co.in
INTERNATIONAL DIVISION VADODARA
R-14, T.T.C. MIDC, Thane-Belapur Road, Rabale, Navi Mumbai 400 705. Nirali Apartments, Near Ellora Park Telegraph Office, Vadodara 390 007.
Tel: 022-2769 7112/3/4 Fax: 022-2769 7918 Tel: 0265-239 6506, 239 7638 Fax: 0265-239 8508
E-mail: rabcrointl@ionexchange.co.in E-mail:brdcro@ionexchange.co.in
REGIONAL OFFICES BRANCH OFFICES
CHENNAI Bangalore - Tel: 080-528 4696/7, 526 3904 Fax: 080-529 5795
Ion House, 42, B.N. Reddy Road, Chennai 600 017. E-mail: bngcro@ionexchange.co.in
Tel: 044-2815 3293, 2815 0807 Fax: 044-2815 3361 Chandigarh - Tel: 0172-745 011 Fax: 0172-744 594
E-mail: checro@ionexchange.co.in E-mail: chd.general@ionexchange.co.in
Hyderabad - Tel: 040-2339 7760 Fax: 040-2339 7761
DELHI E-mail: hydcro@ionexchange.co.in
Block-B, Flat No. 8, Local Shopping Center, Ring Road, Naraina Vihar, Indore - Tel: 0713-506 4875 Fax: 0731-504 1578
New Delhi 110 028 E-mail: indore.gen@ionexchange.co.in
Tel: 011-2577 1160/6061, 2577 1348 Fax: 011-2577 4837 Lucknow - Tel: 0522-223 8589 Fax: 0522-223 8545
E-mail: delcro@ionexchange.co.in E-mail: luk.general@ionexchange.co.in
KOLKATA Pune - Tel: 020-714 6063 Fax: 020-714 6109
New Alipore Market Complex, Block-M, Phase 1, 5th Floor, New Alipore, Email: pun.general@ionexchange.co.in
Kolkata 700 053. FACTORIES
0104 PC-37 01 01

Tel: 033-2400 4341/49, 2400 0797 Fax: 033-2400 4345 Ankleshwar Hosur Patancheru Rabale Verna
E-mail: calcro@ionexchange.co.in
ALL INDIA NETWORK OF SERVICE COMPANIES AND DEALERS
Visit us at www.ionindia.com

You might also like