2 Drawings ...................................................................................................................... 6
2.1 Flow Chart ............................................................................................................ 6
2.2 Drawings ............................................................................................................... 7
2.2.1 PA 625 Separator Mounting Drawing, DIN ............................................................... 7
2.2.2 PA 625 Separator with Sludge Removal kit Mounting Drawing, DIN........................ 8
2.2.3 PA 625 Separator Mounting Drawing, JIS ............................................................... 9
2.2.4 PA 625 Separator with Sludge Removal Kit Mounting Drawing, JIS ..................... 10
2.2.5 P 625 Separator Basic Size Drawing ..................................................................... 11
2.2.6 P 625 Separator Foundation Drawing ................................................................... 12
2.2.7 Temperature Sensor 2 x Pt100 with Spring Pocket ................................................ 13
2.2.8 Valve Block Water Assembly Drawing ................................................................... 14
2.2.9 Control Unit EPC 50 Dimension Drawing ............................................................... 15
2.2.10 Starter Dimension Drawing..................................................................................... 16
2.3 Electrical System Layout ............................................................................. 17
2.4 Electrical Diagrams ......................................................................................... 18
2.4.1 Cable List .............................................................................................................. 18
2.4.2 Interconnection Diagram, Starter ........................................................................... 21
2.4.3 Interconnection Diagram, Transmitters .................................................................. 22
2.4.4 Interconnection Diagram, Solenoid Valves ............................................................ 24
2.4.5 Interconnection Diagram, Solenoid Valves cont. ................................................... 25
2.4.6 Interconnection Diagram, Optional Equipment ...................................................... 26
2.4.7 Transformer Connection Diagram ......................................................................... 27
2.4.8 Circuit Diagram, Power Circuits ............................................................................. 28
2.4.9 Circuit Diagram, Separator Starter and Feed Pump ............................................. 29
2.4.10 Circuit Diagram, Remote Start Interlock (optional)................................................. 30
2.4.11 Circuit Diagram, ESD-relay and Trip Contacts (optional)....................................... 31
4 Specifications ....................................................................................................... 35
4.1 Cables .................................................................................................................. 35
4.2 Cable Routing .................................................................................................... 36
4.3 Oil, Water, Steam, and Condensate Piping.............................................. 36
4.4 Ambient Temperature Limitation................................................................ 37
4.5 Sludge Tank ....................................................................................................... 37
4.6 Sludge Piping ..................................................................................................... 39
1810956-02
5 Commissioning and Initial Start ............................................................... 41
5.1 Completion Check List ...................................................................................41
5.2 Initial Start-up ...................................................................................................43
5.2.1 Calculating Operating Pressure .............................................................................45
1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 1 TECHNICAL DATA
1 Technical Data
1.1 Demand Specification Water
Alfa Laval ref. 574487 rev. 1
Poor quality of the operating water may with time cause erosion, corrosion and/or
operating problems. The water shall be treated to meet certain demands.
NOTE
1810956-02 3
1 TECHNICAL DATA PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
4 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 1 TECHNICAL DATA
As necessary Repair
(components)
1810956-02 5
6
2 DRAWINGS
Block mounted
1810956-02
Piping, not Alfa
Laval supply
Alt.
Heating system
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
X0 23 6 71 A
201 Oil inlet
Height
# 540 Ventilation
#) Kit, to be connected on both
panels 709 Mains supply
3x230/400/440/480/575/690 V AC
Heating system
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
1810956-02
l
Pressure
gauge Detail Connections
2.2.1 PA 625 Separator Mounting Drawing, DIN
A Flange: DN25-PN16-DIN2633
B Flange: DN50-PN6-DIN2633
(If BV mounted)
Vacuum Pressure C Water pipe connection ISO-G1/2
gauge gauge size
G Pipe 1” (welding)
7
X0 23 6 80 C
8
201 Oil inlet
2 DRAWINGS
Height
#) Kits, to be kPa (5-7 bar).
connected on both #
panels 540 Ventilation
Heating system
1810956-02
Connections
X0 23 84 9 B
201 Oil inlet
Height:
#) Kits, to be 540 Ventilation
connected on #
both panels 709 Mains supply
3x230/400/440/480/575/690 V
Temperature indicator
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
Heating system l
Connections
1810956-02
A Flange: JIS 25A 10K
size
Optional
(If BV mounted)
Vacuum Not included in Alfa
gauge Pressure Laval delivery
gauge
*) Internal flexible connections
(enclosed with Alfa Laval delivery)
Feed pump
Sludge tank
9
X02 3 69 0C
10
201 Oil inlet
540 Ventilation
Height:
#) Kits, to be
connected on # 709 Mains supply
both panels 3x230/400/440/480/575/690 V
Temperature indicator
Heating system l
Connections
1810956-02
A Flange: JIS 25A 10K
Optional
Feed pump
X0 23 85 0 C
Maximum vertical displacement
Maximum horizontal displacement at the sludge connection during
at the inlet/outlet connections operation ±2 mm
during operation ±5 mm
1810956-02
2.2.5 P 625 Separator Basic Size Drawing
4 holes M10
11
X0 23 69 2A
12
Min. lifting capacity required
when doing service: 300 kg
2 DRAWINGS
1810956-02
2.2.6 P 625 Separator Foundation Drawing
Centre of motor
Centre of separator bowl
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
X02 35 9 8B
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS
X0 2 44 81 A
Ref. 1764439 Rev. 0
1810956-02 13
2 DRAWINGS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
Valve block
Flexible connection
Flexible connection
X01 9 21 5E
14 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS
Operating panel
Separator interlock
indication (optional) Emergency stop,
Separator
On-off, feed
Pump
Sludge valve
interlock indication
(optional)
On-off,
Selector switch Separator
Rem/Loc (optional)
Plugged holes
for extra cable
glands
Technical Data
Protection class IP 65
Weight 19 kg
Optional
X0 2 36 93 A
1810956-02 15
2 DRAWINGS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
Bottom view
Front view
Technical Data
Weight 15 to 20 kg
X02 36 9 4A
16 1810956-02
Ref. 574677 Rev. 1
Control unit SUM
Circuit boards:
- Vibration Alarm
Remote
- Communication
- Heater control OP unit
Remote
- Remote temp. alarms Temp. Al.
Remote
Start/Stop
Data
Comm.
System
Emergency
Starter
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
1810956-02
Heating system
Feed pump
Functional blocks
2 DRAWINGS
17
X02 3 69 6B
2 DRAWINGS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
18 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS
1810956-02 19
2 DRAWINGS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
20 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS
Mains suppy
3 x 230, 400, 440, 480, 575 or 690 V AC
Select correct voltage on transformer T8
Separator motor
STARTER
Feed pump motor
optional
1810956-02 21
2 DRAWINGS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
To EPC 50 (sheet 5)
To EPC 50 (sheet 5)
STARTER
Sludge valve interlock switch
optional
Remote stop
Feed pump
Remote start
Heater interlock
Potential free contact, max. 250 V 0.5 A
(Feed pump running = contact closed)
Tripped motor circuit breakers (optional)
Potential free NC contacts, max. 250 V, 0.5 A
To EPC 50 (sheet 3)
X0 23 70 2 A
22 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS
connections
Internal
Remote OP unit
* Termination jumper.
(Only at sattbus end units)
Optional
Heater board
Temp. sensor, 2xPT 100
TT 1 (Alarm)
TT 2 (Control)
PT4
Sheet 5
Speed transmitter
(optional)
Internal connections
Vibration transmitter
(optional)
LS
Level switch sludge tank
(optional)
X0 2 37 03 B
1810956-02 23
2 DRAWINGS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
to S1
connection
internal
Present
Signal to alarm panel.
Pot. free contact, opens at alarm
SV1
Oil feed
SV15
Opening water
SV16
Closing water
Internal connections
24 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS
24 V phase
Systems Emergency stop
(Control voltage off)
24 V neutral
voltages
Connections for alternative
Jumpers at 110/115 V AC
Jumper at 230 V AC
From starter (sheet 2)
Sheet 6
X0 23 70 5 A
1810956-02 25
2 DRAWINGS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
Sheet 5
Sheet 5
VIBR. BOARD
For steam heater see 1765868
For elecrtric heater see 1765867
Separation Start/Stop
Note
Jumper X71:1 to X71:3 to
avoid false alarm when not Start
Stop
used.
COMM. BOARD
26 1810956-02
Main switch
Line filter
To I/O
board (Alarm)
Yellow/green
Protective earth
Brown
Brown Red
Black Brown
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
Black
2.4.7 Transformer Connection Diagram
Black
White
1810956-02
Blue
To I/O Blue
board Green
Green
Red Yellow
Red
Red
Red
Red
Red
2 DRAWINGS
27
X0 18 9 21 A
2 DRAWINGS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
Mains supply
Separator
Space heater
(optional)
Feed pump
Space heater
(optional)
X0 2 37 07 A
Cont.
28 1810956-02
Ref. 574673 Sheet 2, Rev. 0
EMERGENCY STOP
1810956-02
PILOT LAMP,
FEED PUMP
FEED PUMP FEED BACK
(Remote indication)
2 DRAWINGS
29
X0 2 37 08 A
2 DRAWINGS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
Separator interlock
indication
Aux. relay
Aux. relay
Separator Interlock
(Optional)
Switch
Vibration
Board
X0 2 37 09 A
30 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 2 DRAWINGS
X0 2 37 10 A
1810956-02 31
2 DRAWINGS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
32 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 3 REMOTE OPERATION SYSTEMS
ING
WARN
!
Disintegration hazard
If the system is operated from a position from
which the separator is not visible, a Remote
Operation System must be installed, including
vibration sensor and frame cover interlock switch.
1810956-02 33
3 REMOTE OPERATION SYSTEMS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
34 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 4 SPECIFICATIONS
4 Specifications
4.1 Cables
Cable Identification
All cables are to be marked to simplify
identification and fault finding.
Specifications
The following specifications apply to cables
connected to and from Alfa Laval equipment.
Follow the instructions given in the cable list.
Examples of cable types that can be used:
• Steel armoured cable.
G 0 32 22 4A
• Copper armoured cable with a separate earth
core.
G 0 32 2 44 A
• Steel armoured and shielded signal cable;
pair twisted or parallel.
G 03 22 14 A
1810956-02 35
4 SPECIFICATIONS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
S0 02 89 1A
reduces electrical noise transfer.
Examples of recommended routing of various
cable types.
Power Signal
• Power cables and signal cables routed on a Cables Cable
cable rack should be separated.
• Sattbus cables should be routed away from
G 03 22 7 3A
power cables.
If the space is limited, cables can be routed in
tubes.
Specifications
• The correct pipe size must be used in the oil
system.
• The number of bends in the oil pipes must
be minimized.
• The suction height must be as low as
possible.
• The oil feed pump must be of positive
displacement type.
• The pump must be positioned close to the
oil tank.
• The heater must be installed close to the
separation system to maintain correct feed
oil temperature.
• The recirculation line should be connected
either directly to the settling tank (HFO) or to
the oil outlet line from the separator (LO).
• The oil outlet line from the separator must be
connected to the system tank for lube oil, or
the service tank for fuel oil.
36 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 4 SPECIFICATIONS
G 00 42 7 3A
Min. slope 15°
• The sludge outlet pump connection should be
positioned in the lowest part of the tank.
• A high level alarm switch, connected to the
sludge pump, should be installed.
• A heating coil should be used to keep the
Bowl casing drain Manhole Water drain High level
sludge warm and fluid while being pumped connection connection alarm
switch
out.
• Tank ventilation must follow the classification
rules for evacuation of gases. Heating
coil
• There should be a ventilation pipe to fresh air.
• The ventilation pipe should be straight. If this
G 00 42 70 A
1810956-02 37
4 SPECIFICATIONS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
38 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 4 SPECIFICATIONS
Specification
• The sludge pipe from the separator to the
sludge tank should be vertical.
If a vertical pipe is not possible, the deviation (A)
from the vertical line must not exceed 30°.
G 0 04 40 1A
• The sludge pipe must not extend below the
tank top.
NOTE
G 0 0 43 16 A
1810956-02 39
4 SPECIFICATIONS PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
NOTE
G 0 0 44 11 A
40 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 5 COMMISSIONING AND INITIAL START
ING
WARN
!
Breakdown hazard
Check that the power frequency is in agreement with
the machine plate. If incorrect, resulting overspeed
may cause breakdown.
NOTE
NOTE
1810956-02 41
5 COMMISSIONING AND INITIAL START PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
NOTE
6 Power on.
ON
CAUTI
!
42 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 5 COMMISSIONING AND INITIAL START
NOTE
1810956-02 43
5 COMMISSIONING AND INITIAL START PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
44 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 5 COMMISSIONING AND INITIAL START
Pmin + Pmax
= Pnormal
2
Pmin + Pnormal
= Plow press.
2
Pnormal + Pmax
= Phigh press.
2
1810956-02 45
5 COMMISSIONING AND INITIAL START PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
46 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 6 SHUT-DOWN AND STORAGE
1810956-02 47
6 SHUT-DOWN AND STORAGE PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
Rubber Parts
• Gaskets, O-rings and other rubber parts
should not be stored for more than two years.
After this time, they should be replaced.
Separator
Dismantle the separator bowl and take out the
o-rings. Clean the bowl with oil and reassemble
without the o-rings. Place in a plastic bag with
silica dessicant bags and seal the plastic bag.
Grease the spindle.
48 1810956-02
PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE 6 SHUT-DOWN AND STORAGE
1810956-02 49
6 SHUT-DOWN AND STORAGE PA 625 SEPARATION SYSTEM INSTALLATION SYSTEM REFERENCE
50 1810956-02