You are on page 1of 28

The right choice for

your application:
Temperature sensors
from ifm.

Process sensors

ifm.com/gb/temperature
Systems for
temperature monitoring:
The optimum solution
for every requirement

Compact temperature sensors


for industrial applications

Compact temperature sensors


for mobile applications

Temperature sensors in Compact temperature sensors


contact with the medium for hygienic applications

Temperature sensors –
the modular concept for industrial
and hygienic applications

Accessories
Process adapters, thermowells,
jumper cables and certificates

Non-contact Infrared temperature sensors


temperature sensors for hot objects

2
e

e
tio 00
y

or
]
C]

ito
p

ob
tio
la

ns
ty

n

ec 10
[m

pr
on
ua
is

se
ge

nn PT
or

D
h

m
al

00
ns

e
pt

co /
ev
ra

bl
10
l

s 0
Se

ro
de

es 10

ca
g

T
d

nt

/P
rin

te

oc PT
n

0
co
tio

00
ra
su

0
g

te

T1
10
lla
ea

te

ra

/P
PT
ta

pr
.m

in

pa
s

ith
in

0
ith
ax

Se

10
ax

w
w
M

PT
M

or
ns
Se
TA -50...150 150

TN -50...150 150
4- 9
TK -20...140 250

TV -50...150 30

TA / TU -50...150 200

10 - 11
TM -40...150 50

TA -50...200 350

TD -50...150 350
12 - 17
TCC
with drift -25...160 450
monitoring

TR -100...600
TP -50...300
TM -40...150 250 18 - 21
TS -100...600 200
TT -40...150 560

22 - 25

TW
detecting 50...1350
system
26 - 27
TW
measuring 0...2500
system

3
The compact units:
Temperature sensors
Communicative:
for industrial applications Temperature sensors with
switching outputs or continuous
transmission of measured values
via IO-Link.

Temperature sensors in contact with the medium


Convenient:
Switch point setting via setting
ring (type TK) or via LR DEVICE
software and IO-Link (type TV).

Precise:
High accuracy thanks to the
adjustment of the PT element
and the electronics.

Robust:
Pressure resistance up to 400 bar.

Flexible:
Different process connections
and installation depths.

Type TK Measuring range Process Installation depth Order no.


temperature connection
sensor [°C] [mm]
Easy adjustment of Normally open / normally closed complementary
the switch points
via two setting -20...140 G 1/4 50 TK6110
rings allowing
2 x NO
optimum read-
out. -20...140 G 1/4 50 TK7110
Mechanical lock to 1 x NO / 1 x NC
prevent accidental
adjustment. -20...140 G 1/2 250 TK7460
T05 / T09: 1 / 3 s.
Pressure-resistant
up to 400 bar.
Accuracy [K]: ± 3.

4
For industrial
applications

Type TV Measuring range Process Installation depth Order no.


temperature connection
sensor [°C] [mm]
Two solutions: 2 switching outputs
Continuous
transmission of G 1/4 25 TV7105
-50...150
measured values G 1/2 30 TV7405
via IO-Link – and
two switching
outputs.
Tamper free.
T05 / T09: 1 / 3 s.
Pressure-resistant
up to 400 bar.
Accuracy [K]: ± 0.3.

h NPT
Units wit ection
onn
process c aling at
and °F c m
s
ifm.co

5
The compact units:
Temperature sensors
Informative:
for industrial applications Temperature transmitter with
current output, LED operating
status indication and IO-Link.

Temperature sensors in contact with the medium Simple:


Preset measuring ranges configu-
rable via LR DEVICE and IO-Link.

Precise:
High accuracy thanks to the
adjustment of the PT element
and the electronics.

Functional:
LED operating status indication
signals voltage supply and indi-
cates communication of the cur-
rent output in 2-wire operation.

Robust:
Fully welded stainless steel
housing for extreme installation
conditions.

Type TA Measuring range Process Installation depth Factory setting [°C]


temperature connection
transmitter -50...150 0...100
[°C] [mm] Order no. Order no.
Scalable analogue
output 4...20 mA Analogue output 4...20 mA
IO-Link.
25 TA2105
T05 / T09: 1 / 3 s.
50 TA2115
Pressure-resistant G 1/4
100 TA2135
up to 400 bar.
150 TA2145
Accuracy [K]: -50...150
± 0.3 + (± 0.1 % Ms). 30 TA2405
50 TA2415 TA2417
G 1/2
100 TA2435 TA2437
150 TA2445 TA2447

6
For industrial
applications

PT100 / PT1000 Accessories


sensors Process adapters,
Pages 18 - 21 thermowells
Pages 22 - 25

7
The compact units:
Temperature sensors
Savings potential:
for industrial applications Evaluation electronics and inte-
grated process connections in
one unit do not require complex
documentation and save storage
cost.
Temperature sensors in contact with the medium
Unmistakable:
Clear indication of acceptable
ranges. Programmable red / green
display.

Simple:
Setting via display and buttons
on the unit or via IO-Link.

Visible:
345° rotatability – for optimum
readability.

Elaborate:
Fast access to the data sheet
via QR code on the device.

Type TN Measuring range Process Installation depth Factory setting [°C]


temperature connection
sensor -40...150
[°C] [mm] Order no.
Selectable colour
display. 1 switching and 1 analogue output 4...20 mA or 0...10 V
Operation via
Internal thread
3 buttons. -50...150 45 TN2511
M18 x 1.5
Scalable analogue
2 switching outputs
output 4...20 mA /
0...10 V. Internal thread
-50...150 45 TN7511
Freely configurable M18 x 1.5
switching output.
IO-Link.
T05 / T09: 1 / 3 s.
Pressure-resistant
up to 300 bar.
Accuracy [K]:
± 0.3 + (± 0.1 % Ms).

PT100 / PT1000 Accessories


sensors Process adapters,
Pages 18 - 21 thermowells
Pages 22 - 25

8
For industrial
applications

Type TN Measuring range Process Installation depth Factory setting [°C]


temperature connection
sensor -50...150
[°C] [mm] Order no.
Selectable colour
display. 2 switching outputs or 1 switching and 1 analogue output 4...20 mA or 0...10 V
Operation via
25 TN2105
3 buttons. G 1/4
50 TN2115
2 x NO / NC or
1 x NO / NC and 30 TN2405
-50...150
1 analogue output 50 TN2415
4...20 mA / 0...10 V, G 1/2
100 TN2435
scalable.
150 TN2445
IO-Link.
T05 / T09: 1 / 3 s.
Pressure-resistant
up to 400 bar.
Accuracy [K]:
± 0.3 + (± 0.1 % Ms).

h NPT
Units wit ection
onn
process c aling at
and °F c m
s
ifm.co

9
The compact units:
Temperature sensors
Suitable:
for mobile applications Temperature transmitter with
current or voltage output or
PT1000.

Temperature sensors in contact with the medium Versatile:


Connector versions M12,
DEUTSCH and AMP selectable.

Economical:
Operating voltage as of 8 V.

Robust:
Fully welded stainless steel
housing and high pressure
resistance of up to 400 bar.

Simple:
Plug and Play via preset
measuring ranges.

Flexible:
Different process connections
and installation depths.

Type TA / TU Measuring range Process Installation depth Connector Order no. Order no.
temperature connection
transmitter [°C] [mm]
Welded stainless Analogue output 4...20 mA 0.5...4.5 V
steel housing.
Installation depths 25 M12 TA3105 TU3105
of 25 to 200 mm. 50 M12 TA3115
T05 / T09: 1 / 3 s. 200 M12 TA3155
Accuracy [K]: -50...150 G 1/4 25 DEUTSCH TA4105 TU4105
± 0.3 + (± 0.1 % Ms). 50 DEUTSCH TA4115
25 AMP TA5105 TU5105
50 AMP TA5115

10
Systems for
mobile machines

PT1000 with process Measuring range Process Installation depth Connector Order no.
connection type TM connection
Installation depths [°C] [mm]
of 25 to 50 mm. PT1000
T05 / T09: 1 / 3 s.
G 1/4 25 M12 TM5105
Accuracy [K]:
± (0.15 + 0.002 x |t|). -40...150 G 1/2 50 M12 TM5411
G 1/4 25 DEUTSCH TM6101

PT100 / PT1000 Accessories


sensors Process adapters,
Pages 18 - 21 thermowells
Pages 22 - 25

11
The compact units:
Temperature sensors
Informative:
for hygienic applications Temperature transmitter with
current output, LED operating
status indication and IO-Link.

Temperature sensors in contact with the medium Precise:


High accuracy thanks to
temperature adjustment at
three reference points.

Verified:
Free 3-point factory certificate
available at
www.factory-certificate.ifm.

Extended:
Measuring range from
-50 to 200 °C; preset measuring
ranges configurable via IO-Link.

Fast:
Response time ≤ 0.5 s.

Flexible:
Adapter system for all common
process connections such as
Varivent, SMS or DIN11851 pipe
fitting.

Type TA Measuring range Process Installation depth Factory setting [°C]


temperature connection
transmitter 0...200 0...100 -10...150
[°C] [mm] Order no. Order no. Order no.
Operating status
indication via LED. Analogue output 4...20 mA, probe Ø 6 mm
Scalable analogue
50 TA2212
output 4...20 mA.
100 TA2232
Hygienic process
connections. Ø 6 mm 150 TA2242 TA2247 TA2241
Installation depths 250 TA2262
of 25 to 150 mm. 350 TA2292
IO-Link. Flush mount TA35971)
T05 / T09: 30 TA2502
≤ 0.5 / ≤ 2 s. G 1/2
50 TA2512 TA2517 TA2511
-50...200 with sealing cone
Accuracy [K]: 100 TA2532 TA2537 TA2531
± 0.3 + (± 0.1 % Ms).
150 TA2542
25 TA2002
Clamp 1/2 - 3/4"
60 TA2012
30 TA2802
50 TA2812
Clamp 1 - 1.5"
100 TA2832
150 TA2842
1) No IO-Link

12
For hygienic areas
and viscous media

Measuring range Process Installation depth Factory setting [°C]


connection
0...200 0...100 -10...150
[°C] [mm] Order no. Order no. Order no.
Analogue output 4...20 mA, probe Ø 3 mm

M12 x 1.5
-50...200 17 TA1102 TA1107 TA1101
with sealing cone

-50...200 G 3/82) 83 TA1322 TA1327 TA1321

2) Suitable for installation in thermowells

data
Technical s? PT100 / PT1000 Accessories

and price
sensors Process adapters,
Pages 18 - 21 thermowells
ifm.com Pages 22 - 25

13
The compact units:
Temperature sensors
Informative:
for hygienic applications Temperature transmitter with cur-
rent output, display and IO-Link.

Helpful:
Temperature sensors in contact with the medium Adjustment of temperature and
controller via display.

Robust:
Fully welded stainless steel
housing protects against the
ingress of moisture and prevents
temperature drift.

Precise:
High accuracy thanks to
temperature adjustment at
three reference points.

Verified:
Free 3-point factory certificate
available at
www.factory-certificate.ifm

Flexible:
Further process connections
available via a flexible adapter
system.

Temperature Measuring range Process Installation depth Factory setting [°C]


transmitter with connection
type TD display -10...150 0...100
[°C] [mm] Order no. Order no.
4-digit LED display.
Scalable analogue Analogue output 4...20 mA
output 4...20 mA.
50 TD2211 TD2217
Hygienic process
100 TD2231 TD2237
connections.
150 TD2241 TD2247
Installation depths
of 30 to 350 mm. Ø 6 mm 200 TD2251 TD2257
IO-Link. 250 TD2261 TD2267
T05 / T09: 1 / 3 s. -50...150 300 TD2271 TD2277
Accuracy [K]: 350 TD2291 TD2297
± 0.3 + (± 0.1 % Ms). 30 TD2501 TD2507
G 1/2 50 TD2511 TD2517
with sealing cone 100 TD2531 TD2537
150 TD2541 TD2547

14
For hygienic areas
and viscous media

Process Installation depth Factory setting [°C]


connection
-10...150 0...100
[mm] Order no. Order no.
Analogue output 4...20 mA
30 TD2801 TD2807
50 TD2811 TD2817
Clamp 1 - 1.5"
100 TD2831 TD2837
150 TD2841 TD2847
30 TD2901 TD2907
50 TD2911 TD2917
Clamp 2"
100 TD2931 TD2937
150 TD2941 TD2947

PT100 / PT1000 Accessories


sensors Process adapters,
Pages 18 - 21 thermowells
Pages 22 - 25

15
The compact units
Temperature sensors
Unique:
for hygienic applications Integrated drift monitoring with
two different resistance elements
(PT and NTC: different characteri-
stics for reliable drift detection).

Temperature sensors in contact with the medium


Reliable:
Permanent drift monitoring
between the calibration intervals
increases machine uptime and
process safety.

Documented:
All process values (measuring
element and reference element)
can be logged via IO-Link (data
logging). This ensures permanent
transparency for quality manage-
ment and calibration intervals
can be adapted or be dispensed
with.

Good to know:
Developed for standard as well
as critical temperature processes
(CCPs = critical control points).

Self-monitoring Insertion depth Process connection


temperature trans-
mitter type TCC G 1/2 sealing cone 1 - 1.5" clamp 2" clamp Ø 6 mm
[mm] Order no. Order no. Order no. Order no.
Free 3-point calibra-
tion certificate. Analogue output 4...20 mA
Diagnostic function.
30 TCC501
Scalable analogue
50 TCC511 TCC811 TCC911
output 4...20 mA.
100 TCC531 TCC831 TCC931 TCC231
IO-Link.
150 TCC541 TCC241
T05 / T09: 1.5 / 4 s.
250 TCC261
Accuracy [K]: +/-0.2.
350 TCC291
450 TCC281
550 TCC201

Accessories
Process adapters,
thermowells
pages 22 - 25

16
For hygienic areas
and viscous media

More reliability in the process


6 months 6 months
01/2019 06/2019 01/2020

Ensure transparency TCC immediately


thanks to drift provides a warning /
warning and the alarm message and
possibility of data ensures reliability in
storage. the process!

Example of function

77.39
Diagnostic output Out 1
76.79
76.19
75.59 Reference element

74.99
[°C]

74.39
73.78
CCL
73.18
72.58 Measuring element
71.98
71.38
time
Measured values Reference element Distance between
stable. is below the reference and
Diagnostic output defined warning measuring element
Out 1 has a high threshold (CCL): exceeds warning
signal. Diagnostic output threshold.
Out 1 has a high Diagnostic output
signal. has a low signal.

17
Temperature sensors –
the modular concept
Individual:
for industrial and hygienic Configure your measurement

applications system according to your require-


ments.

Temperature sensors in contact with the medium Suitable:


Broad range of combination
options.

Visual:
Evaluation units with or without
colour display.

Flexible:
Different process connections
and installation depths.

Far reaching:
Measuring ranges from
-100 to 600 °C.

Convenient:
Thermowells allow replacement
of the sensors in the running
process.

PT100 / PT1000
cable sensors
able type TS
ind a suit
Want to f r online?
senso
ifm.com

Accessories
Process adapters,
thermowells
Pages 22 - 25

18
For industrial For hygienic areas
applications and viscous media

Evaluation unit Type TP


type TR measured signal converter
Selectable colour display. Operating status indication
Scalable analogue output via LED.
4...20 mA / 0...10 V. Scalable analogue output
Freely configurable 4...20 mA
switching output. Minimised installation and
Automatic detection error sources.
of the temperature probe. High vibration resistance.
Accuracy [K]: Accuracy [K]:
± 0.3 + (± 0.1 % Ms). ± 0.3 + (± 0.1 % Ms).

Mounting set Connection Direct connection Direct connection


cable

PT100 / PT1000 PT100 / PT1000 PT100 / PT1000 with PT100 / PT1000


probe sensors cable sensors process connection probe sensors
type TT type TS type TM type TT
For industrial and Measuring probes Industrial and
hygienic applica- Ø 5, 6 and 10 mm. hygienic process
tions. Screw-in sensors in connections.
Different installa- M5 and M6 sizes. Different installa-
tion depths up to Bolt-on sensor for tion depths up to
560 mm. M6 and M10 screws. 250 mm.
Measuring probes Temperature probes Measuring probe
Ø 6 and 10 mm. for the ATEX zone. Ø 6 mm.
Protection rating Different cable Accuracy class A.
IP 67. materials. Pressure resistance
T05 / T09: 1 / 3 s. Protection rating up to 160 bar.
Accuracy [K]: IP 67. High protection
± (0.15 + 0.002 x |t|). T05 / T09: 3 / 10 s. IP68 / IP 69K.
Accuracy [K]: T05 / T09: 1 / 3 s.
± (0.15 + 0.002 x |t|). Accuracy [K]:
± (0.15 + 0.002 x |t|).

19
Temperature sensors –
the modular concept
for industrial and hygienic
applications Evaluation electronics
type TR
Measuring
range
[°C]
1 switching a
Temperature sensors in contact with the medium
-100...600

-100...600

TR evaluation with Direct connection TR or TP evaluation


E30017 mounting set on TR evaluation on with connection cable
PT100 / PT1000 probe PT100 / PT1000 cable on PT100 / PT1000
sensors type TT sensors type TS sensors type TM,
TT or TS

PT100 / PT1000 Measuring Ø probe / Order Order PT100 / PT1000


probe sensors range installation depth no. no. cable sensors
type TT [°C] [mm] type TS
Cable sensors Applications Industry Hygienic
high temperature
type TS 6 / 50 TT9281 TT9291
6 / 70 TT7281
6 / 100 TT0281 TT0291
6 / 150 TT1281 TT1291
-40...150
6 / 200 TT4281
6 / 250 TT2281 TT2291
6 / 300 TT6281
6 / 350 TT3281 TT3291
10 / 160 TT1081
10 / 260 TT2081
-40...150
10 / 360 TT3081
10 / 560 TT5081
6 / 160 TT12501)
-40...150 6 / 260 TT22501)
6 / 360 TT32501)
10 / 160 TT10501)
e choice?
Even mor icles at
10 / 260 TT20501)
-40...150
More art m 10 / 360 TT30501)
ifm.co 10 / 560 TT50501)
Industrial applications
6 / 100 TS2451
6 / 150 TS2452
-100...600
6 / 200 TS2453
6 / 250 TS2454
1) PT1000 sensor element

20
For industrial For hygienic areas
applications and viscous media

Factory setting Process Order Measured signal Measuring Factory setting Connection Order
connection no. converter type TP range no.
[°C] [°C] [°C]
and 1 analogue output 4...20 mA or 0...10 V Analogue output 4...20 mA
-40...300 G 1/2 TR2439 -50...150 TP3231
2 switching outputs -50...300 -50...300 M12 connector TP3232
0...100 TP3237
-40...300 G 1/2 TR7439
Analogue output 0...10 V

-50...300 0...100 M12 connector TP9237

Direct connection
TP evaluation on
PT100 / PT1000 probe
sensors type TT,
TS or TM

Process Measuring Cable / connector / Order PT100 with pro- Process Measuring Installation Order
connection range length no. cess connection connection range depth no.
[°C] [m] type TM [°C] [mm]
Industrial applications Industrial applications
Ø 5 mm ATEX -20...80 silicone / – / 3 TS325A -40...150 25 TM4101
G 1/4
-40...90 PUR / M12 / 2 TS2289 -40...150 25 TM51011)
-40...90 PUR / M12 / 2 TS22691) -40...150 50 TM4411
-40...90 PUR / M12 / 2.5 TS9289 -40...150 50 TM54111)
Ø 6 mm
-40...90 PUR / M12 / 5 TS5289 G 1/2 -40...150 100 TM4431
-50...250 PTFE / M12 / 0.15 TS92561) -40...150 150 TM4441
-50...250 PTFE / M12 / 2 TS2256 -40...150 250 TM4461
-40...90 PUR / M12 / 2 TS2089 Internal thread
-40...125 60 TM9950
M18 x 1.5
-40...90 PUR / M12 / 2 TS20691)
Ø 10 mm
-40...90 PUR / M12 / 5 TS5089 Hygienic applications
-50...250 PTFE / M12 / 2 TS2056 G 1/2
-50...140 Flush mount TM4599
Bolt-on sensor with sealing cone
-40...90 PUR / M12 / 2 TS2229
12 x 8.7 x 51 mm -40...150 20 TM4591
Bolt-on sensor -40...150 30 TM4501
-40...90 PUR / – / 2 TS2239
12.5 x 8.7 x 47 mm G 1/2
-40...150 50 TM4511
Bolt-on sensor ATEX with sealing cone
-20...115 silicone / – / 5 TS502A1) -40...150 100 TM4531
10 x 18 x 48 mm
Bolt-on sensor ATEX -40...150 150 TM4541
-20...115 silicone / – / 5 TS522A
10 x 10 x 42 mm -40...150 30 TM4801
-40...90 PUR / M12 / 2 TS2789 -40...150 50 TM4811
Clamp 1 - 1.5"
-40...90 PUR / M12 / 0.5 TS9789 -40...150 100 TM4831
M5 screw-in sensor -30...180 silicone / M12 / 2 TS2759 -40...150 150 TM4841
-30...180 silicone / – / 4 TS4759 -40...150 30 TM4901
-30...180 silicone / M12 / 10 TS0759 -40...150 50 TM4911
Clamp 2"
-40...90 PUR / M12 / 2 TS2689 -40...150 100 TM4931
M6 screw-in sensor
-30...180 silicone / M12 / 2 TS2659 -40...150 150 TM4941
1) PT1000 sensor element
M8 screw-in sensor -20...115 silicone / – / 2 TS285A

1) PT1000 sensor element


21
Accessories
Process adapters and
thermowells
for temperature sensors

1
e choice?
Even mor icles at Progressive
More art m ring fitting
2
ifm.co
Clamp fitting

Clamp adapter

No. Device Process Installation Order For sensor type


connection connection depth no.
[mm] 4
Industrial applications Screw-in
27 E37700 TA2115 TN2115 TKx110 TT02811) thermowell
up to 16 bar
4 G 1/4 G 1/4 74 E37710 TA2135 TT12811)
124 E37720 TA2145 TT32811)
27 E37600 TA241x TN2415 TM4411 TT02811)
74 E37610 TA243x TN2435 TM4431 TT12811)
82 E35010 TT10814) 5
124 E37620 TA244x TN2445 TM4441 TT22811) Screw-in
174 E37630 TT22811) thermowell
4 G 1/2 G 1/2 up to 16 bar
182 E35020 TT20814)
224 E37640 TM4461 TT32811)
274 E37650 TT32811)
6
282 E35030 TT30814)
482 E35050 TT50814) Welding
thermowell
33 E37603 TA2212 TD221x TT9281 up to
83 E37613 TA2232 TD223x TCC231 TT0281 400 bar
5 Ø 6 mm G 1/2 128 E37623 TA2242 TD224x TCC241 TT1281
233 E37643 TD226x TCC261 TT2281 8
333 E37663 TD229x TCC291 TT3281 Welding
thermowell
Industrial applications / hygienic applications
up to 300 bar
191 E37430 TD227x1) TT32811)
6 1/2 NPS 3) Ø 38,1 mm
267 E37450 TD229x1) TT32811)

22
For industrial For hygienic areas
applications and viscous media

No. Type Device Process Order For sensor type


connection connection no.

Industrial applications
G 1/4 E33431 TA TD TT
1 Progressive ring fitting Ø 6 mm M12 x 1,0 E33433 TA TD TT
G 1/2 E30047 TA TD TT
G 1/2 E30016 TT
1 Progressive ring fitting Ø 10 mm
1/2" NPT E30024 TT
G 1/2 E30018 TA TCC TD TS TT
2 Clamp fitting 6 / 8 / 10 mm
1/2" NPT E30025 TA TCC TD TS TT
Hygienic applications

G 1/2
3 Clamp adapter Ø 6 mm E30144 TA TCC TD TT
with sealing cone

No. Device Process Installation Order For sensor type


connection connection depth no.
[mm]
Hygienic applications

G 1/2 with G 1/2 with 68 E37511 TA253x TD253x TM4531 TT12912)


7
sealing cone sealing cone 118 E37521 TA2542 TD254x TM4541 TT22912)
49 E37411 TA2512 TCC511 TD251x TM4511 TT02912)
G 1/2 with
7 8 Ø 34 mm 99 E37421 TA253x TCC531 TD253x TM4531 TT12912)
sealing cone
Screw-in 149 E37431 TA2542 TCC541 TD254x TM4541 TT22912)
thermowell TA243x TM4431
64 E37810 TD224x1) TT12911)
up to 16 bar TA2333 TM4331
Clamp TA244x TM4441
9 1/2" NPS 3) 115 E37820 TD225x1) TT22911)
1 - 1,5" TA2343 TM4341
191 E37830 TD227x1) TT32911)
267 E37850 TD229x1) TT32911)
TA2435 TM4431
64 E37910 TD224x1) TT12911)
TA2333 TM4331
Clamp TA2445 TM4441
9 1/2" NPS 3) 115 E37920 TD225x1) TT22911)
9 2" TA2343 TM4341

Clamp 191 E37930 TD227x1) TT32911)


thermowell 267 E37950 TD229x1) TT32911)
up to 25 bar

In combination with 1) adapter E30018 / E30047 / E33431, 2) adapter E30144; 3) suitable for G 1/2 and 1/2"NPT
In combination with 4) fitting E30016 / E30018

23
Accessories
Process adapters, jumper
cables and certificates
for temperature sensors

No. Type Device Process Order For sensor type


connection connection no.
10
Stainless steel adapter M18 x 1.5 G 1/2 E30073 TM TN
Titanium adapter M18 x 1.5 G 1/2 E40114 TM TN Adapter
10 Hastelloy adapter M18 x 1.5 G 1/2 E40175 TM TN
Brass adapter M18 x 1.5 G 1/2 E40097 TM TN
Plastic adapter M18 x 1.5 Ø 23 mm E40138 TM TN 11
Ball 24.7 mm Ø 6 mm Clamp adapter E30108 TA TD TT
11 Welding
Ball 25 mm Ø 6 mm Clamp adapter E30407 TA TD TT adapter

w?
Order no p at
ho
In the e - s m
ifm .c o

Plug / socket Cable length Order


no.
[m]
Jumper cable type EVC Industrial applications
with M12 plug / socket
(selection) 1 EVC017
straight / angled
5 EVC019
1 EVC027
angled / straight
5 EVC029
1 EVC032
angled / angled
5 EVC034
1 EVC012
straight / straight
5 EVC014
Connection cable type EVF Hygienic applications
with M12 socket
(selection) 5 EVF001
straight
10 EVF002
5 EVF004
angled
10 EVF005

24
For industrial For hygienic areas
applications and viscous media

No. Type Device Process Order For sensor type


connection connection no.

Clamp 1 - 1.5" E33701


G1 DIN 11851 DN32 E33711
12 12 Metal-to-metal seal
Aseptoflex Vario Varivent DN25 E33721
Process adapter SMS DN40 E33731
Clamp 1 - 1.5" E33201
DIN 11851 DN32 E33211
G1
12 Sealing by O-ring Varivent DN25 E33221
Aseptoflex Vario
DN/OD 33.7 E33304
DRD flange E33242
Clamp 1 - 1.5" E33401 TA TCC TD TM
DIN 11851 DN25 E43304 TA TCC TD TM
G1/2 Varivent DN25 E43306 TA TCC TD TM
12 Metal-to-metal seal
with sealing cone SMS DN25 E33430 TA TCC TD TM
G 3/4 E43302 TA TCC TD TM
G1 E43303 TA TCC TD TM

Ø 35 E30055 TA TCC TD TM TT 2)
G1/2
11 Metal-to-metal seal
with sealing cone
Ø 45 E30056 TA TCC TD TM TT 2)

In connection with: 2) adapter E30144

Calibration and material certificates Order


Type no.

Declaration of compliance EN10204-2.1 ZC0001


Inspection certificate material EN10204-3.1 ZC00035)
3-point DAkkS calibration temperature sensors ZC0013
5-point DAkkS calibration temperature sensors ZC0014
n-point DAkkS calibration temperature sensors ZC0015
3-point ISO calibration temperature sensors ZC0016
5-point ISO calibration temperature sensors ZC0017
n-point ISO calibration temperature sensors ZC0018
5) Only available for selected article numbers

25
Infrared
temperature sensors
Without contact:
for hot objects Exact temperature measurement
of particularly hot objects or ob-
jects which are difficult to access.

Non-contact temperature sensors Hot:


For object temperatures of
0…2.500 °C.

Informative:
Display of the current object
temperature (type TW20xx).

Precise:
LED pilot light for alignment
and control.

Accurate:
Scratch-resistant precision
lenses for minimum sensitivity
to ambient light.

Practical:
Simulation function, activated
on the sensor or remotely.

Type TW70xx Measuring range Wave length Order no. Type TW20xx
temperature range temperature
sensor [°C] [μm] sensor
2 switching Detecting system Scalable analogue
outputs. output 4...20 mA.
2 binary switching outputs
Easy switch-point Freely configurable
setting via display. 50...500 8...14 TW7000 2) switching output.
3-pushbutton 250...1250 1...1.7 TW70012) Easy emissivity set-
operating concept. ting via display.
350...1350 1...1.7 TW70111) 2)
Accuracy [K]: 3-pushbutton
1) Sensor for fibre-optics and measuring head
see data sheet. 2) No
operating concept.
IO - Link
Local temperature
No. Type Order no. indication.
Accuracy [K]:
see data sheet.
Fibre optic 2 m E35061
1
Fibre optic 5 m E35062
2 Measuring head E35060

1 2

26
For industrial
applications

Select the 16
Measurement error [°C]

optimum sensor 8 -14 µm


The optimum 12
sensor is to be as
short-wave as pos- 8 1.1-1.7 µm
sible: The shorter 0.78 -1.06 µm
the wavelength
and the smaller 4
the spectral range,
the lower the im- 0
pact of changes of 0 500 1000 1500 2000 2500 3000
the object’s emis- Temperature [°C]
sion factor on the
measurement. Temperature measuring error depending on the temperature and
the wave length at 1% change of the degree of emission

Measuring range Wave length Order no. without Order no. with
range LED pilot light LED pilot light
[°C] [μm]
Measuring system
Analogue output 4...20 mA and switching output
0...1000 8...14 TW2000 TW2100
250...1600 1...1.7 TW2001 TW2101
500...2500 0.78...1.06 TW2002
300...1600 1...1.7 TW20113)
3) Sensor incl. fibre-optics and measuring head

Accessories No. Type Order no.


Calibration
certificates
3 Air purge E35063
4
4 Cooling jacket E35068 3
5 Mounting bracket E35065
6 Protective tube E35066
7 Insulating tube E35067
Factory calibration sheet for infrared temperature sensors ZC0061 5
Recalibration for TW20xx infrared temperature sensor ZC0062
Recalibration for TW2002 infrared temperature sensor ZC0063 6 7

27
Go ifmonline!
Browse, select, order
in the ifm webshop

ifm.com

Position sensors Identification systems

Sensors for Condition monitoring


motion control systems

ifm article no. 78003413 · We reserve the right to make technical alterations without prior notice. · Printed in Germany on non-chlorine bleached paper. 10/19
Industrial imaging Systems for
mobile machines

Safety technology Connection


technology

Process sensors Software

Industrial Power supplies


communication

IO-Link Accessories

RANTY
AR
W

ifm electronic gmbh


years
Friedrichstraße 1
s

45128 Essen
ct

Tel. +49 / 201 / 24 22-0 on u


Fax +49 / 201 / 24 22-1200 if m p r o d
E-mail info@ifm.com

You might also like