SUMMARY OF QUANTITIES

ITEM NO. DESCRIPTION QTY. UNIT


A.1.1(8) Provision of Field Office for the Engineer (Rental Basis) 4.00 mo
B.3 Permits and Clearances 1.00 l.s
B.5 Project Billboard/ Sign Board 1.00 ea
B.7(2) Occupational Safety and Health Program 1.00 l.s
B.9 Mobilization/Demobilization 1.00 l.s.
800 (3) a1 Individual Removal of Trees (150 - 300 mm dia.) small 4.00 Each
801(1) Removal Of Structures and Obstruction 1.00 l.s
803(1)a Structure Excavation (Common Soil) 196.98 m3
804(1)a Embankment from Structure Excavation 105.37 m3
804(1)b Embankment (from Borrow) 111.83 m3
804(4) Gravel Fill 33.92 m3
900(1)c2 Structural Concrete (Footings and Slab on Fill, Class A, 28 days) 50.71 m3
900(1)c3 Structural Concrete (Footing Tie Beams, Class A, 28 days) 17.28 m3
900(1)c4 Structural Concrete (Columns, Class A, 28 days) 25.89 m3
900(1)c5 Structural Concrete (Suspended Slab, Class A, 28 days) 27.61 m3
900(1)c6 Structural Concrete (Beams/Girder, Class A, 28 days) 30.44 m3
902(1)a Reinforcing Steel (Deformed, Grade 40) 27,248.42 kg
903(2) Formworks and Falseworks 960.52 m2
1000(1) Soil Poisoning 115.60 L
1046(1)a1 CHB Load Bearing (including Reinforcing Steel), 100mm 129.91 m2
1046(1)a2 CHB Load Bearing (including Reinforcing Steel), 150mm 399.98 m2
1010(4) Wooden Doors and Windows 1.00 l.s.
1009(1)a Jalousie Windows (Glass) 24.05 m2
1005(1) Residential Casement (Steel) 48.96 m2
1005(6) Window Accessory 1.00 l.s
1004(2) Finishing Hardware 1.00 l.s
1003(17) Carpentry and Joinery Works 1.00 l.s.
1021(1)c Cement Floor Finish w/ Floor Hardener 424.17 m2
1027(1) Cement Plaster Finish 1,783.22 m2
1051(6) Railing 1.00 l.s
1003(1)a1 Ceiling (4.5mm thk., Fiber Cement Board, Metal Frame) 237.86 m2
1038(1) Reflective Insulation 315.48 m2
1018(1) Glazed Tiles and Trims 71.55 m2
1018(2) Unglazed Tiles 20.05 m2
1032(1)a Painting Works (Masonry/Concrete) 1,946.86 m2
1032(1)b Painting Works (Wood) 104.49 m2
1032(1)c Painting Works (Steel) 50.14 m2
1014(1)b1 Prepainted Metal Sheets ( Corrugated Type, Long Span) 315.48 m2
1013(2)a1 Fabricated Metal Roofing Accessory (Ridge Roll) 23.90 l.m
1013(2)a2 Fabricated Metal Roofing Accessory (Flashing) 26.21 l.m
1013(2)b1 Fabricated Metal Roofing Accessory (Gutter) 47.80 l.m
1047(2)a Structural Steel (Trusses) 2,271.38 kg
1047(2)b Structural Steel (Purlins) 3,687.15 kg
1003(11)a1 Fascia Board (19mm thk, Fiber Cement Board) 47.80 m
1047(6) Metal Structure Accessories (Steel Plates) 277.47 kg
1047(7)b Metal Structure Accessories (Sagrods) 101.34 kg
1047(4) Metal Structure Accessories (Cross Bracing) 214.42 kg
1047(3)c Metal Structure Accessories (Turnbuckle) 18.00 ea
1047(10) Metal Structure Accessories (Fire Escape) 1.00 l.s.
1001(8) Sewer Line Works 1.00 l.s.
1002(24) Cold Water Lines 1.00 l.s
1001(9) Storm Drainage and Downspout 1.00 l.s.
1002(4) Plumbing Fixtures 1.00 l.s.
1001(11) Septic Vault (Concrete/CHB) 1.00 l.s.
1001(5)a Catch Basin (Concrete) 12.00 ea
1202(6)a1 Fire Extinguisher (10 lbs., ABC with Bracket) 1.00 set
1100(10) Conduit, Boxes & Fittings (Conduit Works/Conduit Rough-in) 1.00 l.s.
1101(33) Wires and Wiring Devices 1.00 l.s.
1102(1) Panelboard with Main & Branch Breakers 1.00 l.s.
1103(1) Lighting Fixtures and Lamps 1.00 l.s.
1208(1) Fire Alarm System 1.00 l.s.

PROJECT TITLE & LOCATION: SHEET CONTENTS: DESIGNED: SGD SUBMITTED: RECOMMENDING APPROVAL: APPROVED: SET NO. SHT. NO.
Republic of the Philippines MARA LOUANNE K. SAAVEDRA
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS CONSTRUCTION OF 1-UNIT 2-STOREY ARCHITECT II
REGIONAL OFFICE VII
SIQUIJOR DISTRICT ENGINEERING OFFICE
4-CLASSROOM SCHOOL BULDING AT LARENA
CENTRAL ELEMENTARY SCHOOL, LARENA, SUMMARY OF QUANTITIES
DRAWN: SGD
EPHEGEN D. TIGMO A-2 2
SGD SGD SGD
Larena, Siquijor DRAFTSMAN II
SIQUIJOR
CHECKED: SGD
CHRISTIAN GEORGE B. PAL-ING
ENGINEER III
NORMAN C. CARPIO
ASST. DISTRICT ENGINEER
ELVIS G. CALUNOD
DISTRICT ENGINEER
13 52
JOHN CARL O. TAMBAHOYOT CHIEF,PLANNING & DESIGN SECTION
ENGINEER II

PDF processed with CutePDF evaluation edition www.CutePDF.com


REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
PABLO G. RACINES PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) STANDARD TWO-STOREY BOD 20
STRUCTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING GENERAL NOTES S-1
POSITION: STRUCTURAL ENGINEER
( 6-CLASSROOMS ) 52
PRC No.: 0014064 TIN No.: 108-321-474 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY
PTR No.: 2181624 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
J-BOLT TO PURLIN & G.I
2 ANCHOR BOLT DETAIL 5 ROOFING FIXER 6 SHEET CONNECTION DETAIL
S-10 SCALE 1:30M
S-10 SCALE 1:30M
S-10 NOT TO SCALE

TRU
SS
TOP
CHO
RD

4 J-BOLT SPACING
S-10 NOT TO SCALE

CEILING LINE

1 TRUSS DETAIL AT GUTTER END


S-10 SCALE 1:5 M.

3 ROOF PANEL SIDE LAP DETAIL


S-10 NOT TO SCALE

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
(SEE COVER SHEET) (SEE COVER SHEET) TRUSS DETAIL AT GUTTER END, ANCHOR BOLT BOD
PABLO G. RACINES PABLO G. RACINES STANDARD TWO-STOREY DETAIL, ROOF PANEL SIDE LAP DETAIL, J-BOLT 29
STRUCTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING SPACING, ROOFING FIXER, J-BOLT TO PURLIN & G.I S-10
POSITION: STRUCTURAL ENGINEER
( 2, 4 & 6-CLASSROOMS ) SHEET CONN. DETAIL
52
PRC No.: 0014064 TIN No.: 108-321-474 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY
PTR No.: 2181624 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
6 SECTION OF STAIR SLAB 7 SPOT DETAIL
S-11 SCALE 1:15M S-11 SCALE 1:25M

9 DETAIL
S-11 SCALE 1:25 M.

8A DETAIL PLAN
S-11 SCALE 1:15M.
5 DETAIL
S-11 SCALE 1:25 M.

8B DETAIL SECTION
S-11 SCALE 1:15M.

( FROM GROUND FLOOR

2 TYPICAL SLAB ELEVATION TO 2ND FLOOR LEVEL )

S-12 NOT TO SCALE 8 DETAIL, DC-1


SCALE 1:15M
S-11

SECTION

ELEVATION

1 TYPICAL BEAM DETAILS


S-11 NOT TO SCALE

3 STAIR FRAMING PLAN 4 STAIR SECTION DETAIL


S-11 SCALE 1:50M S-11 SCALE 1:30M

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
(SEE COVER SHEET) (SEE COVER SHEET) TYPICAL BEAM DETAILS, BOD
PABLO G. RACINES PABLO G. RACINES STANDARD TWO-STOREY TYPICAL SLAB ELEVATION 30
STRUCTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING SCHEDULE OF BEAM, DETAIL OF STAIR, S-11
POSITION: STRUCTURAL ENGINEER
( 2, 4 & 6-CLASSROOMS ) DC-1 PLAN & SECTION DETAIL
52
PRC No.: 0014064 TIN No.: 108-321-474 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY
PTR No.: 2181624 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
3 SPOT DETAIL
SCALE 1:20M
S-12
4 DETAIL SECTION
S-12 SCALE 1:20M
6
7 SPOT DETAIL
SCALE 1:30M.
S-12

2 SPOT DETAIL
S-12 SCALE 1:20M.

6 SECTION OF STAIR SLAB


S-12 SCALE 1:15M

5 SPOT DETAIL
S-12 SCALE 1:15M.

1B ELEVATION
SCALE 1:30M.
S-12

1A PLAN
S-12 SCALE 1:30M. 1 STAIR FROM THIRD FLOOR TO DECK ROOF
SCALE AS SHOWN
S-12
REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
PABLO G. RACINES PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) STANDARD TWO-STOREY BOD 31
STRUCTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING STAIR DETAIL TO DECK ROOF S-12
POSITION: STRUCTURAL ENGINEER
( 2, 4 & 6-CLASSROOMS ) 52
PRC No.: 0014064 TIN No.: 108-321-474 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY
PTR No.: 2181624 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
2000
B

1000 1000
1400

4A ELEVATION
S-13 SCALE 1:10 M.

2 DETAIL ELEVATION 3 DETAIL ELEVATION


S-13 SCALE 1:30 M. S-13 SCALE 1:30 M.

1 FIRE ESCAPE FRAMING PLAN


S-13 SCALE 1:20 M. 4A PLAN
S-13 SCALE 1:10 M.

4 DETAIL
S-13 SCALE 1:10 M.

5 DETAIL
S-13 SCALE 1:10 M.

6 DETAIL
S-13 SCALE 1:10 M.

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
PABLO G. RACINES PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) STANDARD TWO-STOREY BOD 32
FIRE ESCAPE FRAMING PLAN, ELEVATION &
STRUCTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING DETAILS S-13
POSITION: STRUCTURAL ENGINEER
( 2, 4 & 6-CLASSROOMS ) 52
PRC No.: 0014064 TIN No.: 108-321-474 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY
PTR No.: 2181624 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
ER
8 R ING
3 ST
8 WP x1
C8
x1 C8
3S
TR
ING
ER

5 DETAIL
S-14 SCALE: 1:10 M.
4 DETAIL
S-14 SCALE: 1:10 M.

2 SECTION B-B
S-14 SCALE: 1:15 M.

50

50

3 SECTION C-C
S-14 SCALE: 1:15 M.

1 SECTION A-A
S-14 SCALE: 1:15 M.

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
PABLO G. RACINES PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) STANDARD TWO-STOREY BOD 33
STRUCTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING FIRE ESCAPE DETAIL S-14
POSITION: STRUCTURAL ENGINEER
( 2, 4 & 6-CLASSROOMS ) 52
PRC No.: 0014064 TIN No.: 108-321-474 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY
PTR No.: 2181624 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
PABLO G. RACINES PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) STANDARD TWO-STOREY BOD 21
STRUCTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING GENERAL NOTES S-2
POSITION: STRUCTURAL ENGINEER
( 6-CLASSROOMS ) 52
PRC No.: 0014064 TIN No.: 108-321-474 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY
PTR No.: 2181624 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
2 2ND FLOOR FRAMING PLAN
S-3 SCALE 1:100 M.

1 FOUNDATION PLAN
S-3 SCALE 1:100 M.

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
PABLO G. RACINES PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) STANDARD TWO-STOREY BOD 22
FOUNDATION PLAN,
STRUCTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING SECOND FLOOR FRAMING PLAN S-3
POSITION: STRUCTURAL ENGINEER
( 6-CLASSROOMS ) 52
PRC No.: 0014064 TIN No.: 108-321-474 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY
PTR No.: 2181624 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
7 8

125
500
6 DETAIL
S-4 SCALE 1:10M.

1 RAMP DETAIL 150

S-4 SCALE 1:30M

.
THK
mm
125
SCHEDULE OF FOOTING DET. OF STAIR ON GRADE
2
S-4 SCALE 1:25M

5 DET. OF WALL ON FTB


S-4 SCALE 1:20M.

COLUMN SCHEDULE

400 400 400

SECTION
400

400

400

WF-1 SECTION

400 400 400


400

400

400

ELEVATION

PLAN
3 TYPICAL FOOTING DETAIL WF-2 SECTION
TYPICAL DETAIL
S-4 NOT TO SCALE
7 OF R.C. COLUMN
4 DETAIL OF WALL FOOTINGS S-4 SCALE 1:25 M.

S-4 SCALE 1:20 M.

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS SCHEDULE OF FOOTING & COLUMN RAMP DETAIL,
PABLO G. RACINES PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) STANDARD TWO-STOREY DETAIL OF STAIR ON GRADE BOD 23
STRUCTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING DETAIL OF TYPICAL FOOTING DETAIL, DETAIL OF WALL FOOTINGS S-4
POSITION: STRUCTURAL ENGINEER
( 2, 4 & 6-CLASSROOMS )
& FOOTING TIE BEAM 52
PRC No.: 0014064 TIN No.: 108-321-474 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY TYPICAL DETAIL OF R.C. COLUMN
PTR No.: 2181624 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
(2-STOREY 4 CLASSROOMS) (2-STOREY 2CLASSROOMS)
2 ROOF FRAMING PLAN AT BOTTOM CHORD LEVEL 4 ROOF FRAMING PLAN AT BOTTOM CHORD LEVEL
S-6 SCALE 1:100 M. S-6 SCALE 1:100 M.

(2-STOREY 4 CLASSROOMS) (2-STOREY 2 CLASSROOMS)


1 ROOF FRAMING PLAN AT TOP CHORD LEVEL 3 ROOF FRAMING PLAN AT TOP CHORD LEVEL
S-6 SCALE 1:100 M S-6 SCALE 1:100 M

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
PABLO G. RACINES PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) STANDARD TWO-STOREY BOD 25
ROOF FRAMING PLAN AT TOP CHORD & BOTTOM
STRUCTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING LEVEL(2 STOREY 2 & 4 CLASSROOMS) S-6
POSITION: STRUCTURAL ENGINEER
( 6-CLASSROOMS ) 52
PRC No.: 0014064 TIN No.: 108-321-474 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY
PTR No.: 2181624 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
C B A

5 DETAIL 6 DETAIL
SCALE 1:20 M.
S-7 SCALE 1:20 M. S-7

4 ELEV. OF END WALL FRAME


SCALE 1:30 M.
S-7

CONCRETE
7 SUN BREAKER DETAIL
S-7 SCALE 1:10 M.
2 DETAIL 8 SC-1 DETAIL
S-7 SCALE 1:80 M.
S-7 SCALE 1:20 M.
C B A

3 DETAIL
S-7 SCALE 1:20 M.

9 CONNECTION OF PURLINS TO RB-1


S-7 SCALE 1:15 M.

1 ELEV. OF END WALL FRAME & HALF TRUSS @ GRID 7 10 DET. SECTION OF RB-1 AND PC-1
SCALE 1:25 M.
S-7 S-7 SCALE 1:15 M.

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
(SEE COVER SHEET) (SEE COVER SHEET) ELEV. OF END WALL FRAME & HALF TRUSS, ELEV. OF END BOD
PABLO G. RACINES PABLO G. RACINES STANDARD TWO-STOREY WALL FRAME GRID 7, CONCRETE SUNBREAKER DETAIL, SC-1 26
STRUCTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING DETAIL PLAN & ELEVATION, CONN. OF PURLINS TO RB-1, DETAIL S-7
POSITION: STRUCTURAL ENGINEER
( 6-CLASSROOMS ) SECTION OF RB-1 & PC-1
52
PRC No.: 0014064 TIN No.: 108-321-474 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY
PTR No.: 2181624 BUILDINGS DIVISION, BOD REVISED 3-24-17
3 DETAIL-1 4 DETAIL-2 9A PLAN
S-8 SCALE 1:10 M. S-8 SCALE 1:10 M.
S-8 SCALE 1:10 M.

6 DETAIL-3
S-8 SCALE 1:10 M. 8B SECTION
250
S-8 SCALE 1:10 M.

250
8 WELD DETAIL
2 DETAIL 5 DETAIL-4 S-8 NOT TO SCALE

S-8 SCALE 1:10 M. S-8 SCALE 1:10 M. 8A ELEVATION


S-8 SCALE 1:10M.

8 DETAIL
S-8 SCALE AS SHOWN

C B 9B ELEVATION
S-8 SCALE 1:10 M.

A
B TRUSS SUPPORT
A A
C
B
9 CONNECTION DETAIL
B S-8 SCALE AS SHOWN.
C
C
C
C
C C
C
C C

B
B B

1 TRUSS - 1 ELEVATION
S-8 SCALE 1:20M.

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
(SEE COVER SHEET) (SEE COVER SHEET) TRUSS DETAILS, BOD
PABLO G. RACINES PABLO G. RACINES STANDARD TWO-STOREY TRUSS SUPPORT CONNECTION DETAIL, 27
STRUCTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING SCHEDULE OF TRUSS MEMBERS AND WELDS, S-8
POSITION: STRUCTURAL ENGINEER
( 2, 4 & 6-CLASSROOMS ) WELD DETAIL
52
PRC No.: 0014064 TIN No.: 108-321-474 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY
PTR No.: 2181624 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
4A FOR NON - CONTINUOUS PURLINS 4B FOR CONTINUOUS PURLINS
S-9 SCALE 1:5 M.
S-9 SCALE 1:5 M.
5 PURLIN SPLICE
S-9 SCALE 1:5M

4 PURLIN CONNECTION DETAIL


S-9 SCALE 1:5 M.

1B SECTION 1B SECTION
S-9 SCALE 1:10 M S-9 SCALE 1:10 M
2B SECTION
S-9 SCALE 1:10 M

3B SECTION
S-9 SCALE 1:5 M

8
XX
XX

XX
XX

XX
XX

XX
XX

XX
XX

xx
XX
XX

xx
XX
XX

xx
XX

xx
X

XX
XX

xx
X

xx
xx
xx

x
xx

xx
xx

xx
xx
xx

xx
xx

xx
xx

xx
xx

xx
xx
xx
xx

xx
xx

xx
xx
X

xx
xx
XX

xx
XXX

xx
XX

xx
XX XX

xx
XX XX

x
XX XX
XX

XX
XX

XX
XX

XX
XX

XX
x
xx

xx
xx

xx
xx

xx
xx

x
xx

xx

xx
xx

xx

xx

xx
xx

xx

xx

xx
xx

xx

xx

xx
xx

xx

xx

xx
xx

xx

xx

xx
xx

xx

xx

xx
xx

xx

xx

xx
xx

xx

xx

xx
xx

xx
xx

xx
xx

xx
x

x
xx
xx
xx
xx

xx
xx

xx
xx

xx
xx

xx
xx
xx
xx

xx
xx

xx
xx

xx
xx

xx
xx
xx
xx

xx
xx

x
xx
xx
xx
xx
xx
xx
xx
xx
1A PLAN
1A PLAN S-9 SCALE 1:10 M 2A PLAN
S-9 SCALE 1:10 M S-9 SCALE 1:10 M

3A PLAN
S-9 SCALE 1:10 M
DETAIL CONN. OF CROSS- DETAIL CONN. OF CROSS- DETAIL CONN. OF
DETAIL OF PURLIN TO
1 BRACING AT END WALL 1 BRACING AT GRID LINE A & C 2 CROSS-BRACING AT TRUSS @ APEX
S-9 SCALE 1:10 M.
S-9
3 SAG ROD CONNECTION
SCALE AS SHOWN S-9 SCALE AS SHOWN
S-9 SCALE AS SHOWN

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH DETAIL CONN. OF CROSS BRACING AT END WALL PLAN &
PROPOSED PROJECTS SECTION, DETAIL CONN. OF CROSS-BRACINING AT (GRID LINE A
PABLO G. RACINES PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) STANDARD TWO-STOREY & C) PLAN & SECTION, DETAIL CONN. OF CROSS-BRACING AT BOD 28
STRUCTURAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING TRUSS @ APEX PLAN & SECTION, DETAIL OF PURLIN TO SAG ROD S-9
POSITION: STRUCTURAL ENGINEER
( 2, 4 & 6-CLASSROOMS )
CONNECTION PLAN & SECTION, PURLIN CONN. DETAIL FOR NON 52
PRC No.: 0014064 TIN No.: 108-321-474 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY CONTINUOUS PURLINS & CONTINUOUS PURLINS AND PURLIN
PTR No.: 2181624 BUILDINGS DIVISION, BOD (REVISED 3-24-17) SPLICE
PANELBOARD: LP FLUSH MOUNTED, NEMA 1 ENCLOSURE WITH GROUND TERMINAL

CIRCUIT BREAKER
CKT.
WIRE & CONDUIT SIZE
NO. LOAD VOLT POLE AT AF kAIC
GENERAL NOTES :

1 2

3 4

5 6

7 8

9 10

11 12

13 14

LEGEND
RECOMMENDED SIZE OF TRANSFORMER
2 PANEL BOARD DIAGRAM
E-1 NOT TO SCALE
1

WF
450

5000mm

1800mm

WP

FA

FLUORESCENT LIGHT
F

ELECTRICAL RISER DIAGRAM


B

3
4 FIXTURE MOUNTING DETAIL E-1 NOT TO SCALE
M

E-1 NOT TO SCALE


MDP

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS LOAD SCHEDULE, GENERAL NOTES & LEGEND,
MANUEL V. PANIS PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) BOD 41
STANDARD TWO-STOREY PANEL BOARD DIAGRAM, ELECTRICAL RISER
ELECTRICAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS GILBERTO S. REYES RAUL C. ASIS SCHOOL BUILDING DIAGRAM, FLUORESCENT LIGHT FIXTURE E-1
POSITION: PRO. ELECTRICAL ENGINEER
MOUNTING DETAIL
52
PRC No.: 01210 TIN No.: 132-466-222 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY ( 4-CLASSROOMS )
PTR No.: 4856593 BUILDING DIVISION, BOD (REVISED 3-24-17)

PDF processed with CutePDF evaluation edition www.CutePDF.com


1 2 3 6 7 8 1 2 3 6 7 8
600 22700 600 600 22700 600
9000 9000 5000 9000 9000 5000
4500 4500 4500 4500 1900 1200 1600 4500 4500 4500 4500 1900 1200 1600

4100 (TYPICAL) 4100 (TYPICAL)

1100

1100
675

675
A A

1000

1000
SHE WF WF SHE
2000 2000

2000

2000
2 2 2 2 2 2
1000 1000 HE 1000 1000 HE
a b c a b c

CLASSROOM 4 CLASSROOM 6 CLASSROOM 4 CLASSROOM 6


7000

7000
1 1
5
LP 1
9500

9500

9500

9500
3

4000

4000
LP
2 2 2 2 2 2
a b c a b c
5
LP

WF WF
B F

B
DN B 7
LP
DN
2500

2500
1 1 1 1 1

C C
1100

1100
1 SECOND FLOOR POWER LAYOUT 3 SECOND FLOOR LIGHTING LAYOUT
E-3 SCALE 1:100M. E-3 SCALE 1:100M.

1 2 3 6 7 8 1 2 3 6 7 8
23000 23000
9000 9000 5000 9000 9000 5000
4500 4500 4500 4500 1850 1450 1400 4500 4500 4500 4500 1850 1450 1400

A A

1000

1000
WF WF
PWD PWD
2000 2000
SHE SHE

2000

2000
2 2 2 2 2 2
1000 1000 HE 1000 1000 HE
a b c a b c

CLASSROOM 1 CLASSROOM 3 CLASSROOM 1 CLASSROOM 3


7000

7000
8 10
LP LP 1
9500

9500

9500

9500
1
4000

4000
FPP LP
2 2 2 2 2 2
LP a b c a b c
6
MDP LP
ATS STO. WF WF
STO.
LP

B F

B
UP B 2
LP
UP
2500

2500
1 1 1 1 1

C C
400

400
UP UP UP UP
1200

1200
200 8600 200 200 8600 200

3600 1500 3600 1500

2 GROUND FLOOR POWER LAYOUT 4 GROUND FLOOR LIGHTING LAYOUT


E-3 SCALE 1:100M. E-3 SCALE 1:100M.

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
MANUEL V. PANIS PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) BOD 42
STANDARD TWO-STOREY POWER LAYOUT AND
ELECTRICAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING LIGHTING LAYOUT E-2
POSITION: PRO. ELECTRICAL ENGINEER 52
PRC No.: 01210 TIN No.: 132-466-222 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY ( 4-CLASSROOMS )
PTR No.: 4856593 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
LEGEND:
FE

FIRE EXTINGUISHER DETAIL

1 2 3 4 5 6 1 2 3 4 5 6

A A

FE FE FE FE
B B

C C

1 GROUND FLOOR FIRE PROTECTION PLAN 2 SECOND & THIRD FLOOR FIRE PROTECTION PLAN
FP-1 SCALE 1:100 M.
FP-1 SCALE 1:100 M.

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
MANUEL D. TORRES PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) GROUND FLOOR, SECOND FLOOR, FIRE BOD 49
STANDARD TWO-STOREY
MECHANICAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING
PROTECTION PLAN, FIRE EXTINGUISHER DETAIL, FP-1
POSITION: MECHANICAL ENGINEER LEGEND, SCHEDULE OF EQUIPMENT 52
PRC No.: 2195 TIN No.: 145-553-983 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY ( 4-CLASSROOMS )
PTR No.: 3399286 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
3 4

3 ELEVATION OF OVERHEAD WATER TANK TO


TO
MC MC MCB MC MC PUMP "1"
WP-1 NOT TO SCALE PUMP "2"

B ALT
1&2

1 1
P P
C 8 6 2 2 6 8
9 7 7 9
3
S 4 3 S
BH TYPE BW TYPE
5
2 RH RELAY RH RELAY

2 PARTIAL ROOF PLAN


LEGEND :
WP-1 SCALE 1:100 M.
GATE VALVE

CHECK VALVE

PRESSURE GUAGE

3 4 TEE

ELBOW

FOOT VALVE

LWL LOW WATER LEVEL

IWL INTERMEDIATE WATER LEVEL

A HWL HIGH WATER LEVEL

MCB MAIN CIRCUIT BREAKER

CB CIRCUIT BREAKER

MC MAGNETIC
CONTACTOR

SCHEMATIC DIAGRAM OF
B 500 5 WATER LEVEL CONTROL
WP-1 NOT TO SCALE

PARTIAL GROUND FLOOR


1 (SHOWING LOCATION OF CISTERN)
WP-1 SCALE 1:100 M. ISOMETRIC DIAGRAM OF
4 WATER PUMPING SYSTEM
WP-1 NOT TO SCALE

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH PARTIAL GROUND FLOOR (SHOWING LOCATION OF
PROPOSED PROJECTS CISTERN, PARTIAL ROOF PLAN, ELEVATION OF
MANUEL D. TORRES PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) BOD 48
STANDARD TWO-STOREY OVERHEAD WATER TANK, ISOMETRIC DIAGRAM OF
MECHANICAL DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING WATER PUMPING SYSTEM, SCHEMATIC DIAGRAM WP-1
POSITION: MECHANICAL ENGINEER
OF WATER LEVEL CONTROL, SCHEDULE OF
52
PRC No.: 2195 TIN No.: 145-553-983 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY ( 4-CLASSROOMS )
PTR No.: 3399286 BUILDINGS DIVISION, BOD (REVISED 3-24-17) EQUIPMENT
GENERAL NOTES :
1. ALL PLUMBING WORKS TO BE DONE AND SIZES OF PIPES DS
TO BE USED SHALL BE IN ACCORDANCE WITH THE LATEST
EDITION OF THE NATIONAL PLUMBING CODE OF THE
PHILIPPINES AND LOCAL REGULATIONS AND ORDINANCES.
2. ALL PIPES SHALL BE INSTALLED AS INDICATED IN THE
WORKING DRAWINGS. ANY RELOCATION REQUIRED FOR PLAN
PROPER EXECUTION OF OTHER TRADES SHALL BE UPON
THE APPROVAL OF THE SANITARY ENGINEER.
3. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER
FROM
SCALED DIMENSIONS.
SOURCE
4. ALL PIPES SHALL BE PROVIDED W/ PROPER HANGER AND
SUPPORT
5. ALL FIXTURES SHALL BE VENTED INDIVIDUALLY AND
WATERLINES SHALL BE VALVE BY GROUP SPOT DETAIL
6. UNLESS OTHERWISE SPECIFIED, ALL PLUMBING FIXTURES
SHALL BE PROPERLY VENTED. MAXIMUM DISTANCE OF PLAN
VENTILATION FROM FIXTURES SHALL BE 1.50 m MEASURED
ALONG THE LENGTH OF PIPE.
7. ALL PLUMBING FITTINGS SHALL BE ACCESSIBLE FOR
MAINTENANCE. PROVIDE MANHOLE IF SUCH SUPPLY
INSTALLATIONS ARE INSIDE THE CEILING.
8. ALL CHANGES IN DIRECTIONS SHALL BE MADE BY THE SECTION
APPROPRIATE USE OF FORTY FIVE (45) WYE LONG SWEEP
MH
QUARTER BEND. ONE EIGHT WHEN THE CHANGE OF FLOW
FFL
IS FROM HORIZONTAL TO VERTICAL A SINGLE BEND
COMBINATION MAY BE USED ONLY ON VENT PIPE.
9. NO DOUBLE HUB OR DOUBLE TEE BRANCH SHALL BE USED
ON HORIZONTAL SOIL OR WASTE LINES.
10. PROVIDE PIPE SLEEVES AT WALL, COLUMNS OR SLAB TO
PROTECT FROM BREAKAGE.
11. ALL EXPOSED PIPINGS AND FITTINGS IN THE AREAS SHALL
BE CHROME PLATED. PLAN
12. THE BRAND AND OTHER DETAILED PLUMBING FIXTURES
SHALL BE IN ACCORDANCE WITH THE SCHEDULE
FURNISHED BY THE ARCHITECT. SECTION
13. GATE VALVE SHALL BE BRONZE BODY, SOLID WEDGE SECTION
TYPE, SCREWED OR FLANGE END.
14. USE POLYPROPYLENE RANDOM,TYPE 3,PN20 FOR ALL 4 AIR CHAMBER DETAIL 5 CLEAN-OUT DETAIL
WATER PIPING SYSTEM. P-1 SCALE NTS P-1 SCALE NTS
15. USE uPVC SANITARY PIPING SYSTEM SERIES 1000 FOR 100
1 CATCH BASIN DETAIL
SUPPLY
16. ENGINEER-IN-CHARGE TO VERIFY ACTUAL LOCATION AND P-1 SCALE NTS

ELEVATION OF STREET DRAINAGE, STREET SEWER AND


STREET WATER MAINS FOR CONNECTION BEFORE
CONSTRUCTION.

LEGEND:
WATER DISTRIBUTION SYSTEM
WATERLINE
PLAN
FIRELINE
GV GATE VALVE
FV FLOAT VALVE
WSP WET STAND PIPE
FFL
DSP DRY STAND PIPE
FHC FIRE HOSE CABINET
BI BLACK IRON PIPE
WASTE, SEWER & VENT SYSTEM
SECTION
SANITARY LINE
VENT LINE
FCO FLOOR CLEAN-OUT 8 TYP. UNDERGROUND WATER TANK DETAIL (DOMESTIC)
FD SHOWER/FLOOR DRAIN
PLAN P-1 SCALE NTS

VS VENT STACK
SS SOIL STACK
VAC VENT ACROSS CEILING
VP VENT PIPE SECTION
PVC POLYVINYL CHLORIDE SERVICE PIPE (mm) RISER (mm)
WP WET PIPE 2-STOREY / 2 CLASSROOM 3600 L
SP SOIL PIPE
SCHEDULE OF DIMENSIONS
2-STOREY / 4 CLASSROOM 7200 L
VTR VENT THRU ROOF PIPE DIMENSION IN MM 2-STOREY / 6 CLASSROOM 10800 L
ST SEPTIC TANK SIZE IN 2-STOREY / 8 CLASSROOM 14400 L
'A' D F
AC AIR CHAMBER 2-STOREY / 10 CLASSROOM 18000 L
50 100x100 225.42
WASTE, SEWER & VENT SYSTEM 2-STOREY / 12 CLASSROOM 21600 L
DRAINAGE LINE 75 125x125 225.42

100 150x150 225.42


DS DOWNSPOUT SLOPE = 1/10 SLOPE = 1/10
150 200x200 282.57
CB CATCH BASIN 9 UNDERGROUND WATER TANK CAPACITY (DOMESTIC)
RD ROOF DRAIN P-1 SCALE NTS
2 FLOOR DRAIN DETAIL
CD CORRIDOR DRAIN P-1 SCALE NTS

PLUMBING FIXTURES
LAV LAVATORY
WC WATER CLOSET
EWT ELEVATED WATER TANK
SECTION L W D

6 TYPICAL SEPTIC TANK DETAIL 2-STOREY / 2 CLASSROOM


2-STOREY / 4 CLASSROOM
2.40
3.00
1.50
2.00
1.00
1.20
P-1 SCALE NTS
2-STOREY / 6 CLASSROOM 3.00 2.50 1.40
2-STOREY / 8 CLASSROOM 3.50 2.80 1.50
L W H Lc 2-STOREY / 10 CLASSROOM 4.00 3.00 1.50
2-STOREY / 2 CLASSROOM 3.00 2.00 1.20 1.20 2-STOREY / 12 CLASSROOM 4.30 3.00 1.70
2-STOREY / 4 CLASSROOM 4.00 2.50 1.50 1.50
2-STOREY / 6 CLASSROOM 4.80 2.50 1.80 1.50
2-STOREY / 8 CLASSROOM 5.80 2.50 2.00 1.50
2-STOREY / 10 CLASSROOM 6.00 3.00 2.00 1.80
2-STOREY / 12 CLASSROOM 6.60 3.00 2.20 1.80 10 UNDERGROUND WATER TANK DIMENSION (DOMESTIC)
P-1 SCALE NTS

3 ROOF DRAIN DETAIL 7 SEPTIC TANK DIMENSION


P-1 SCALE NTS
P-1 SCALE NTS

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH GEN. NOTES & LEGEND MISC. DETAILS
PROPOSED PROJECTS TYP. SEPTIC TANK DETAIL
ROMEO C. OCAMPO PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) SEPTIC TANK DIMENSION BOD 34
STANDARD TWO-STOREY
PLUMBING DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING
UNDERGROUND WATER TANK DETAIL P-1
POSITION: SANITARY ENGINEER
UNDERGROUND WATER TANK CAPACITY 52
PRC No.: 000697 TIN No.: 131-678-239 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY ( 6-CLASSROOMS ) UNDERGROUND WATER TANK DIMENSION
PTR No.: 2181627 BUILDINGS DIVISION, BOD (REVISED 3-24-17) ELEVATED WATER TANK DIMENSION
1 2 3 4 5 6 7 8
31700
9000 9000 9000 5000

4500 4500 4500 4500 4500 4500

CB CB CB CB CB CB
CB CB

675
A WC WC
CO
LAV
FD FD
WC FD

LAV FD
FD
CO
FD

CO LAV

7000
9500
B

2500
CD CD CD CD CD CD CD CD
C

DRAINAGE SYSTEM

1 GROUND FLOOR SANITARY LINE LAYOUT


P-2 SCALE 1:100 M

1 2 3 4 5 6 7 8
31700
9000 9000 9000 5000

4500 4500 4500 4500 4500 4500


675

A CO WC WC
CO

FD FD
LAV
FD
FD
WC
FD CO

FD
LAV
7000
9500

B
2500

2 SECOND FLOOR SANITARY LINE LAYOUT


P-2 SCALE 1:100 M

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
ROMEO C. OCAMPO PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) BOD 35
STANDARD TWO-STOREY GROUND FLOOR SANITARY LINE LAYOUT
MANAGING PARTNER SECOND FLOOR SANITARY LINE LAYOUT P-2
PLUMBING DESIGN
POSITION: SANITARY ENGINEER
JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING 52
PRC No.: 000697 TIN No.: 131-678-239 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY ( 6-CLASSROOMS )
PTR No.: 2181627 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
1 2 3 4 5 6 7 8
31700

9000 9000 9000 5000


4500 4500 4500 4500 4500 4500

675
A WC
GV

LAV WC
WC
PWD GV
LAV
HE
LAV

7000
9500
B

2500
C

1 GROUND FLOOR WATERLINE LAYOUT


P-3 SCALE 1:100 M

1 2 3 4 5 6 7 8
31700

9000 9000 9000 5000


4500 4500 4500 4500 4500 4500
675

A WC WC
LAV

LAV
GV
WC
LAV

GV LAV
7000

FHC
9500

B
2500

2 SECOND FLOOR WATERLINE LAYOUT


P-3 SCALE 1:100 M

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
ROMEO C. OCAMPO PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) BOD 36
STANDARD TWO-STOREY GROUND FLOOR WATERLINE LAYOUT
MANAGING PARTNER SECOND FLOOR WATERLINE LAYOUT P-3
PLUMBING DESIGN
POSITION: SANITARY ENGINEER
JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING 52
PRC No.: 000697 TIN No.: 131-678-239 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY ( 6-CLASSROOMS )
PTR No.: 2181627 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
1 2 3 4 5 6 7 8
31700
9000 9000 9000 5000

4500 4500 4500 4500 4500 4500

A
GV
7000
9500

B
2500

2 ROOF PLAN (WATER LINE LAYOUT)


P-4 SCALE 1:100 M

1 2 3 4 5 6 7 8
31700
9000 9000 9000 5000
4500 4500 4500 4500 4500 4500

RD RD RD RD RD RD RD RD
675

A
7000
9500

B
2500

2 ISOMETRIC DIAGRAM (WATERLINE LAYOUT)


C P-4 SCALE NTS

RD RD RD RD RD RD RD RD

1 ROOF STORM DRAINAGE LAYOUT


P-4 SCALE 1:100 M

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
(SEE COVER SHEET) (SEE COVER SHEET) ROOF PLAN WATER LINE LAY OUT BOD
ROMEO C. OCAMPO PABLO G. RACINES STANDARD TWO-STOREY ROOF STORM DRAINAGE LAYOUT 37
MANAGING PARTNER ISOMETRIC DIAGRAM (WATERLINE P-4
PLUMBING DESIGN
POSITION: SANITARY ENGINEER
JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING LAYOUT) 52
PRC No.: 000697 TIN No.: 131-678-239 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY ( 6-CLASSROOMS )
PTR No.: 2181627 BUILDINGS DIVISION, BOD (REVISED 3-24-17)
1 ISOMETRIC DIAGRAM (SEWER & DRAINAGE LAYOUT)
P-5 SCALE NTS

REVIEWED AS TO
DESIGNED: SUBMITTED: RECOMMENDING APPROVAL APPROVED:(FOR ISSUANCE) PROJECT & LOCATION / BARANGAY: SHEET CONTENTS: SET NO. SHEET NO.
DESIGN CONCEPT:
VARIOUS DPWH
PROPOSED PROJECTS
ROMEO C. OCAMPO PABLO G. RACINES (SEE COVER SHEET) (SEE COVER SHEET) BOD 38
STANDARD TWO-STOREY ISOMETRIC DIAGRAM (SEWER &
PLUMBING DESIGN MANAGING PARTNER JOSEPHINE P. ISTURIS DANTE B. POTANTE RAUL C. ASIS SCHOOL BUILDING DRAINAGE LAYOUT) P-5
POSITION: SANITARY ENGINEER 52
PRC No.: 000697 TIN No.: 131-678-239 CHIEF, DIRECTOR IV, BOD UNDERSECRETARY ( 6-CLASSROOMS )
PTR No.: 2181627 BUILDINGS DIVISION, BOD (REVISED 3-24-17)