HCIA- Data Center Facility V2.

0 Change Instructions

HCIA- Data Center Facility V2.0 Change Instructions


Version Date Instruction
V1.0 2017/6/31 Enable V1.0 training materials, lab guidebooks and exam questions
Enable V2.0 training materials and exam questions
V2.0 2020/12/31 V1.0 was released on June 31, 2017, and V1.0 will become unavailable
from June 30, 2021. The old and new versions coexist for 6 months.

This document is applicable to the version refreshed certification product. It is used to compare the
new and old version of the training materials and detailed changes of the test. It is necessary to specify
the contents of the addition, deletion or optimization of the knowledge points and their proportions.

1. Training material change instructions

Training material 1: EHS Training:


Chapter V1.0 V2.0 Change Instructions

1. Introduction to EHS 0 5% Add the introduction to EHS safety.

2. Engineering 60% 60% Add general safety and battery safety,


Construction Safety and optimize air conditioner safety.

Training material 2: Data Center Facility Introduction


Chapter V1.0 V2.0 Change Instructions
1. Introduction to Data 0 5% Add the development history and lifecycle
Center Development of global data centers and optimize the
development trend.
2. Composition of the 25% 18% Delete the description of the firefighting
Data Center facility system and lighting protection and
grounding system.
3. Common Energy 0% 15% Add common energy consumption
Consumption Indicators Indicators
4. Panorama of Huawei 10% 15% Optimize panorama of Huawei data
Data Center Solutions center solutions

Training material 3:Basic Knowledge of Power Distribution Introduction

Chapter V1.0 V2.0 Change Instructions


1. Basic Concepts of 0 15% Add basic concepts of the power
the Power Distribution distribution
System
2. Common LV 30% 40% Add descriptions of transformers, diesel
Electrical Equipment generators, and power cables.
3. Common Grounding 25% 25% Add the composition and classification of
Systems the grounding system.

Training material 4:UPS Basic Knowledge Introduction

Chapter V1.0 V2.0 Change Instructions


1. Introduction and 10% 10% Add the FusionPower description.
Application of Huawei
HCIA- Data Center Facility V2.0 Change Instructions

UPS

Training material 5:Basic Knowledge of Huawei DC Power Systems

Chapter V1.0 V2.0 Change Instructions


1. Huawei DC Power 0 15% Add the description about the
System introduction composition and working principles of
Huawei DC power supply.

Training material 6:Basic Knowledge of Batteries

Chapter V1.0 V2.0 Change Instructions


1. Battery Overview 10% 10% Add the development history of lithium-
ion batteries and technical specifications
of batteries.
2. Lead-acid Battery 90% 35% Optimize the introduction to lead-acid
batteries.
3. Lithium-ion Battery 25% 30% Add the description of lithium-ion
batteries.
4、Comparison 0% 25% Add feature comparison between VRLA
Between VRLA batteries and lithium-ion batteries.
Batteries and Lithium-
ion Batteries

Training material 7:Introduction to Air Conditioning Systems

Chapter V1.0 V2.0 Change Instructions


1. Classification of Air 20% 10% Optimize Air Conditioning System
Conditioning Systems Classification
2. Air Handling 10% 10% Add the description of the wet film
Equipment humidifier.
3. Common Air 0% 30% Added common air conditioner terms
Conditioner Terms

Training material 8:Basic Knowledge of Precision Air Conditioners in Data Centers

Chapter V1.0 V2.0 Change Instructions


1、Overview of Data 10% 10% Delete Huawei air conditioner naming
Center Air Conditioners rules.
2、Air-Cooled 20% 20% Delete the description of components
Precision Air such as the infrared humidifier.
Conditioner
3. Chilled Water 8% 10% Add the principle description of chilled
Precision Air water precision air conditioners.
Conditioner
4. Indirect Evaporative 0% 5% Add the introduction to indirect
Cooling Air Conditioner evaporative cooling air conditioners.
5. Other Cooling 0% 10% Add fluorine pump cooling and wind wall
Solutions for Equipment cooling solutions.
Rooms

Training material 9:Basic Knowledge of Monitoring Systems

Chapter V1.0 V2.0 Change Instructions


HCIA- Data Center Facility V2.0 Change Instructions

1、Introduction to the 10% 10% Add the development trend of the data
Monitoring System center monitoring system and
introduction of the building monitoring
system.

Training material 10:Functions of Monitoring Systems

Chapter V1.0 V2.0 Change Instructions


1.Functions of 40% 40% Delete Huawei NetEco and add the
Monitoring Systems industry-specific monitoring function.

Training material 11:Introduction to Other Systems of Data Center Infrastructure

Chapter V1.0 V2.0 Change Instructions


1.Fire Protection 0% 30% Integrate the original fire extinguishing
System system introduction material into this
material.
2.Lightning Protection 20% 20% Optimize the description of the surge
and Grounding System protection and grounding system.
3.Integrated Cabling 10% 10% Delete the description of the busway and
System optimize the introduction of the integrated
cabling system.
4.Indoor Decoration 3% 3% Optimize Indoor Decoration System
System introduction

2. Test content change instructions

3.1 HCIA-Data Center Facility V2.0 Test content:


Chapter V1.0 Chapter V2.0 Change Instructions
1. EHS safety Introduction 1. EHS safety Add general and battery
1.1 Accident Probability Introduction safety introduction,
1.2 PPE Protection 1.1 Accident Probability accounting for 10%.
1.3 Network Energy 7% 1.2 PPE Protection 6% Optimize the EHS
Construction Safety Overview introduction and air
1.3 Construction Safety conditioner safety,
accounting for 10%;
2. Data center facility 2. Data center facility Add the introduction to the
introduction introduction data center lifecycle, DC
2.1 Composition of the 2.1 Data Center power supply, and data
Data Center facility Development History center standards,
2.2 Power Consumption 2.2 Composition of Data accounting for 15%.
Index for Data Center Center Facility Delete the fire
2.3 Huawei Data Center 2.3 Data Center extinguishing system
Products 6% Standards 8% introduction and lightning
2.4 Power Consumption protection and grounding
Index 2.5 Huawei Data introduction, accounting
Center Products for 15%. Optimize the
development trend and
Huawei product
panorama, accounting for
10%;
3. Power Distribution 3. Basic Power Add basic concepts of
introduction Distribution Knowledge power distribution,
12% 12%
3.1 Basic Concepts for 3.1 Introduction to the transformers, and low-
Power Distribution Power Distribution voltage power distribution
HCIA- Data Center Facility V2.0 Change Instructions

3.2 Low-Voltage Electrical System cabinets, accounting for


Devices 3.3 Grounding 3.2 Basic Concepts of 35%. Optimize the
system Introduction Power Distribution introduction of the
3.4 Data Center Power 3.3 Common Electrical grounding system,
Distribution Products Equipment accounting for 7%;
Introduction 3.4 Common Grounding
Systems
4. UPS Basic Knowledge 4. UPS Basics Add FusionPower product
Introduction 4.1 Basic Principles and introduction, accounting
4.1 What Is a UPS Working Modes for 3%;
4.2 Huawei UPS 4.2 UPS System
Solutions 11% Configuration 8%
4.3 Common 4.3 Introduction and
Configuration Solutions Application of Huawei
4.4 Typical Application UPS
Scenarios
None 5. Huawei DC Power Add the Huawei DC power
Supply introduction architecture, main
5.1 Architecture and components, battery
Composition management logic, and
0% 5%
5.2 Battery Management application scenarios,
5.3 Application Scenarios accounting for 100%;
5.4 Huawei DC Power
Supply
5.Basic Knowledge of 6. Basic knowledge of Optimize overview of
Battery Introduction batteries battery and lead-acid
5.1 Battery Overview 6.1 Battery Overview battery introduction: 30%;
5.2 Classification and 6.2 Lead-acid batteries Added the introduction to
Naming Rule of Battery 6.3 Lithium-ion battery lithium-ion batteries and
10% 15%
5.3 Structure and Working 6.4 Lead-Acid VS Lithium feature comparison
Principle of Battery Battery between lead-acid
5.4 Application Scenarios batteries and lithium-ion
batteries, accounting for
70%;
7. Air conditioning system 7. Air conditioning system Add descriptions about air
inreoduction 7.1 Principles of the Air conditioner terms and wet
7.1 Principles of the Air Conditioning System film humidifiers,
Conditioning System 7.2 Classification of Air accounting for 20%.
7.2 Classification of Air Conditioning Systems Streamlined air
10% 10%
Conditioning Systems 7.3 Air handling conditioner classification,
7.3 Air handling equipment accounting for 5%;
equipment 7.4 Air System
7.4 Air System 7.5 Common Air
Conditioner Terms
8. Basic Knowledge of 8. Basic Knowledge of Add descriptions about
Huawei Precision Air Precision Air Conditioners chilled water air
Conditioner in Data Centers conditioner principles,
8.1 Air Conditioner 8.1 Air-cooled precision indirect evaporative
Overview air conditioner cooling systems, and
8.2 Air-cooled precision 8.2 Chilled Water other cooling systems in
air conditioner Precision Air Conditioner data center, accounting
15% 14%
8.3 Chilled Water 8.3 Indirect Evaporative for 40%, Delete the air
Precision Air Conditioner Cooling System conditioner terminology,
8.4 Air Conditioner Terms 8.4 Huawei Air components such as
Conditioner Products infrared humidifier, and
Huawei air conditioner
naming rules, accounting
for 10%;
9. Basic Knowledge of the 10% 9. Basic Knowledge of the 8% Add the development
HCIA- Data Center Facility V2.0 Change Instructions

Monitoring System Monitoring System trend of the monitoring


9.1 Introduction to the 9.1 Introduction to the system and introduction to
Monitoring System Monitoring System the building monitoring
9.2 Basic Interfaces and 9.2 Basic Interfaces and system, accounting for
Communication Protocols Communication Protocols 8%;
9.3 Data Center 9.3 Data Center
Monitoring System Monitoring System
10. Functions and 10. Monitoring System Delete the function
features of the monitoring Functions and Features description of Huawei
system 10.1 Overview of the monitoring system,
10.1 Overview of the Monitoring System accounting for 50%.
14% 8%
Monitoring System 10.2 Main Functions Added the description of
10.2 Main Functions 10.3 Huawei Surveillance common data center
10.3 Huawei Surveillance System monitoring functions. 50%;
System
11. Introduction to other 11. Introduction to Other Integrate the introduction
systems in the data center Systems of Data Center to the fire extinguishing
infrastructure Infrastructure system into this course,
11.1 Fresh Air System 11.1 Fire Protection accounting for 20%.
11.2 Cabinet System System Deleted the bus bar
11.3 Lightning Protection 11.2 Fresh Air System description, 5%.
and Grounding System 6% 11.3 Cabinet System 6% Optimized the description
11.4 Integrated Cabling 11.4 Lightning Protection of lightning protection and
System and Grounding System grounding, integrated
11.5 Indoor Decoration 11.5 Integrated Cabling cabling, and decoration
System System systems, accounting for
11.6 Indoor Decoration 10%.
System