Professional Documents
Culture Documents
AND COST-EFFECTIVE
takes that to a whole new In addition, industry regulations state that 95% of the required
level … Now available in inert agent must discharge within 60 seconds after
2 activation. To achieve that discharge rate, our
300 bar, PROINERT
competitors’ inert systems must increase their
offers improved valve already high surge flow rate, increasing the
actuation and increased risk of damage. Consequently, a large venting
area must be installed, to protect the integrity
design options…
of the protected space and the employees.
all at a reduced cost!
2
PROINERT is better... Because of our unique, patented
2
valve design assembly, the PROINERT agent enters the
ON BOARD protected room within the required 60 seconds at a steady flow
ACTUATION
rate, preventing destructive turbulence from
occurring. Therefore, only the amount of
extinguishant you really need is discharged, and
the necessary venting area is much smaller —
reducing your installation costs by as much as
60% on venting hardware!
2
PROINERT ...
safe, cost-effective inert gas fire suppression
I N E R T G A S F I R E P R O T E C T I O N S Y S T E M
Less equipment/cylinders
cylinder, reducing the number of cylinders and accessory
Smaller system footprint equipment necessary. In addition to a sizable reduction
High cylinder pressure in system cost, fewer cylinders translates into an inert
Same low manifold & piping pressure as 200 bar gas solution that takes up less valuable space. And all of
No change in constant rate discharge these benefits are available with no change in the already
No change in room pressure venting requirements safe, efficient constant system flow rate which allows for
smaller-diameter, lower-pressure, less expensive piping.
Cost Savings:
Typically 2
PROINERT
uses fewer
nozzles. CUSTOMER SERVICE CENTER
WITH SUB-FLOOR PIPING
Improved
Coverage: 2
PROINERT
offers a variety of
nozzle sizes and
DATA STORAGE/ options.
SWITCH ROOM
Cost Savings:
Systems can be
easily expanded
with Fike’s
pneumatic
relay.
Cost Savings:
2
PROINERT
uses
low-pressure
piping.
CONTROL
Cost Savings: CENTER
Simplified
2 actuation at the
PROINERT
valve reduces
Storage Tanks hardware costs.
Easy, Economical Refill and Real-Life Testing: Financial Centers and Banks
Because Argon and Nitrogen occur naturally in the environment, Electronics and Data Processing
2
the PROINERT extinguishant is readily available and affordable.
2
Insurance Industry
With PROINERT , real-life discharge testing is feasible.
Libraries
Switch Rooms
Telecom Centers
AND COST-EFFECTIVE
INNOVATIVE: In 1994, we became
the first manufacturer to bring a
INERT GAS SYSTEM
E-mail: facilitiesprotection@fike.com
PROINERT, Fike and Fike Corporation are trademarks or registered trademarks
of Fike Corporation.
©Copyright 2013, Fike Corporation. All rights reserved. Form No. B9134 0613
Printed in the U.S.A.
WWW.FIKE.COM