SmartFill —Technical
Fill-level & temperature measurement for ball mills
6) Load Sensor
4) Temperature
Sensor
5) Sound Sensor
2) Receive Unit
(RU) 1) On Mill Unit (OMU)
p.2
SmartFill—Technical specification
(160 W)
thermocouple j-type
signal ≤ 2 Vpp / 50 Ohm
amplifier sensor
p.3
SmartFill—Technical specification
amplifier sensor
p.4
SmartFill—Technical specification
The Type Selection Module is placed inside the BU and The Galvanic Isolation is placed inside the BU and pro-
switches between different calibrations for different vides an electrical separation for the final fill level and
material types. Active type is coded by four digital si- temperature outputs between the BU and the plant’s
gnals, which are set by the plant‘s PLC. PLC.
This module is needed, when the different types are A subsequent installation on site is possible.
strongly varying in their material composition. A subse-
quent installation on site is possible.
width 20 mm width 36 mm
p.5
SmartFill—Technical specification
d
power supply 110 VAC / 60 Hz
(Base Unit) 230 VAC / 50 Hz
p s
signal ≤ 2 Vpp / 50 Ohm
p s (RG 58, max. 200 m)
I/O Calibration
The analogue outputs are used to signal the calculated After installation a calibration of the sound and load
fill levels (0..130 % of calibrated range) and the meas- sensors is needed. Therefore, the mill has to be run
ured temperature (20..170 °C). Therefore, each sen- empty and full.
sor has got a separate current loop (4..20 mA). For maximum convenience, SmartFill offers automatic
The digital outputs signal the operating status of the calibration modes which can be started and stopped by
Base Unit. using the Display Unit inside the Base Unit.
The displayed range is 130 % to ensure a signal if the
level exceeds 100 % of calibrated range.
Easy calibration (Sound and Load Sensor)
f
c
f
c
s f s f
s s
c
p.6