IECU–U0001, Data link

Integrated Electronic Control Unit

Integrated Electronic Control Unit

Fault Conditions for fault code Observable Probable cause


type symptoms

 Voltage out of range  None  Damaged IECU control


FTB 88 between CAN High wire and unit
(Bus ground point  Damaged EMS control
off)
 Voltage out of range unit
between CAN Low wire and  Short circuit between
ground point CAN High wire and
 Resistance out of range CAN Low wire
between CAN High wire and  Open Circuit in CAN
Fault Conditions for fault code Observable Probable cause
type symptoms

CAN Low wire High wire


 Open Circuit in CAN
Low wire
 CAN High wire shorted
to ground
 CAN Low wire shorted
to ground

Resistance measurement

Measurement Key Measurement points Expected Measured Other


position Value value (Special Tool
PN)
Breakout Wiring
box diagram

Backbone2 Resistance OFF 15 - 16 PA:15 – 50 Ohm –   9998699


(CAN High - CAN Low) PA:16 70 Ohm 9813194

Voltage measurement

Measurement Key Measurement points Expected Measured Other (Special


position Value value Tool PN)
Breakout Wiring
box diagram

CAN Low ON 16 - GND PA:16 – 1V – 3V   9998699


Voltage GND 9813194

Voltage measurement
Measurement Key Measurement points Expected Measured Other (Special
position Value value Tool PN)
Breakout Wiring
box diagram

CAN High ON 16 - GND PA:15 – 2V – 4V   9998699


Voltage GND 9813194

Voltage measurement

Measurement Key Measurement points Expected Measured Other (Special


position Value value Tool PN)
Breakout Wiring
box diagram

Supply ON 13 - GND PA:13 – ≈24V   9998699 9998533


Voltage GND 9813194

Checks on ACM control unit:

Resistance measurement

Measurement Key Measurement points Expected Measured Other


position Value value (Special Tool
PN)
Breakout Wiring
box diagram

Backbone2 Resistance OFF 6-2 A:6 – A:2 50 Ohm –   9998699


(CAN High - CAN Low) 70 Ohm 9813194

Voltage measurement
Measurement Key Measurement points Expected Measured Other (Special
position Value value Tool PN)
Breakout Wiring
box diagram

CAN Low ON 2 - GND A:2 – GND 1V – 3V   9998699


Voltage 9813194

Voltage measurement

Measurement Key Measurement points Expected Measured Other (Special


position Value value Tool PN)
Breakout Wiring
box diagram

CAN High ON 6 - GND A:6 – GND 2V – 4V   9998699


Voltage 9813194

Checks on EMS control unit:

Resistance measurement

Measurement Key Measurement points Expected Measured Other


position Value value (Special Tool
PN)
Breakout Wiring
box diagram

Backbone2 Resistance OFF 22 - 21 EB:22 – 50 Ohm –   9998699


(CAN High - CAN Low) EB:21 70 Ohm 9813194

Voltage measurement
Measurement Key Measurement points Expected Measured Other (Special
position Value value Tool PN)
Breakout Wiring
box diagram

CAN Low ON 21 - GND EB:21 – 1V – 3V   9998699


Voltage GND 9813194

Voltage measurement

Measurement Key Measurement points Expected Measured Other (Special


position Value value Tool PN)
Breakout Wiring
box diagram

CAN High ON 22 - GND EB:22 – 2V – 4V   9998699


Voltage GND 9813194