You are on page 1of 6

IECU–U010E, Data link

Integrated electronic ontrol Unit/IC control unit

Fault type Conditions for fault code Observable Probable cause


symptoms

 Voltage out of range  None  Damaged ACM


FTB 87 between CAN High wire control unit
(Missing and ground point  Blown fuse
Nessage)
 Voltage out of range (FA2)
between CAN Low wire  Open Circuit in
and ground point CAN High wire
 Open Circuit in
CAN Low wire
 CAN High wire
Open Circuit
Fault type Conditions for fault code Observable Probable cause
symptoms

 CAN Low wire


Open Circuit

Checks on ABS control unit

Resistance measurement

Measurement Key Measurement points Expected Measured Other


position Value value (Special Tool
PN)
Breakout Wiring
box diagram

Backbone1 Resistance OFF 8-7 X1:8 – 50 Ohm –   9998699


(CAN High - CAN Low) X1:7 70 Ohm 9990025

Voltage measurement

Measurement Key Measurement points Expected Measured Other (Special


position Value value Tool PN)
Breakout Wiring
box diagram

CAN Low ON 7- GND X1:7 – 1V – 3V   9998699,


Voltage GND 9990025

Voltage measurement
Measurement Key Measurement points Expected Measured Other (Special
position Value value Tool PN)
Breakout Wiring
box diagram

CAN High ON 8- GND X1:8 – 2V – 4V   9998699,


Voltage GND 9990025

Checks on IECU control unit

Resistance measurement

Measurement Key Measurement points Expected Measured Other


position Value value (Special Tool
PN)
Breakout Wiring
box diagram

Backbone1 Resistance OFF 29 - 30 PC:4 – 50 Ohm –   9998699


(CAN High - CAN Low) PC:5 70 Ohm 9998604

Voltage measurement

Measurement Key Measurement points Expected Measured Other (Special


position Value value Tool PN)
Breakout Wiring
box diagram

CAN Low ON 30 - GND PC:5 – 1V – 3V   9998699


Voltage GND 9998604

Voltage measurement
Measurement Key Measurement points Expected Measured Other (Special
position Value value Tool PN)
Breakout Wiring
box diagram

CAN High ON 29 - GND PC:4 – 2V – 4V   9998699


Voltage GND 9998604

Checks on IC control unit

Resistance measurement

Measurement Key Measurement points Expected Measured Other (Special


position Value value Tool PN)
Breakout Wiring
box diagram

Backbone1 Resistance OFF 9 - 10 A:9 – 50 Ohm –   9998699


(CAN High - CAN Low) A:10 70 Ohm 88890209

Voltage measurement

Measurement Key Measurement points Expected Measured Other (Special


position Value value Tool PN)
Breakout Wiring
box diagram

CAN Low ON 10 - GND A:10 – 1V – 3V   9998699


Voltage GND 88890209

Voltage measurement
Measurement Key Measurement points Expected Measured Other (Special
position Value value Tool PN)
Breakout Wiring
box diagram

CAN High ON 9 - GND PC:9 – 2V – 4V   9998699


Voltage GND 88890209

Checks on ACM control unit

Resistance measurement

Measurement Key Measurement points Expected Measured Other


position Value value (Special Tool
PN)
Breakout Wiring
box diagram

Backbone1 Resistance OFF 14 - 10 A:14 – 50 Ohm –   9998699


(CAN High - CAN Low) A:10 70 Ohm 9990014

Checks on EMS control unit

Resistance measurement

Measurement Key Measurement points Expected Measured Other


position Value value (Special Tool
PN)
Breakout Wiring
box diagram

Backbone1 Resistance OFF 51 - 55 EB:51 – 50 Ohm –   9998699


(CAN High - CAN Low) EB:55 70 Ohm 9990014

Voltage measurement
Measurement Key Measurement points Expected Measured Other (Special
position Value value Tool PN)
Breakout Wiring
box diagram

CAN Low ON 55 - GND EB:55 – 1V – 3V   9998699


Voltage GND 9990014

Voltage measurement

Measurement Key Measurement points Expected Measured Other (Special


position Value value Tool PN)
Breakout Wiring
box diagram

CAN High ON 51 - GND EB:51 – 2V – 4V   9998699


Voltage GND 9990014

You might also like