Protocol manual

ALNET II on Ethernet
TCP/IP

applicom® 3.8

a product of Woodhead Software & Electronics

Altus.doc 06/05/2004

Copyright © 2004 Woodhead Software & Electronics. All rights reserved.


http://www.applicom-int.com
electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

Altus.doc 06/05/2004
® TM TM TM
Copyright © 2004 Woodhead Software & Electronics. All rights reserved. applicom , Direct-Link , RJ-Lnxx , SST are registered
trademarks of Woodhead Software & Electronics. Other product names are trademarks of their respective owners.
http://www.applicom-int.com
electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

Table of contents

1. - General .........................................................................................1
- OSI model .............................................................................................................1
- Functionality ..........................................................................................................3
- Client multi-request management .........................................................................4
- Request processing. .............................................................................................5

2. - ALNET II on TCP/IP functionality................................................6


- ALNET II client to a « AL 3405» type server........................................................6
- ALNET II server.....................................................................................................8
- Configuration : Choice of protocol.........................................................................9
- Description of the ALNET II configurator on TCP/IP...........................................11
- Node characteristics............................................................................................12
- Channel properties : General..............................................................................13
- Channel properties: Ethernet ..............................................................................16
- Alnet II properties: ...............................................................................................18
- Properties of the TCP/IP protocol .......................................................................19
- Inserting an equipment........................................................................................21
- Equipment properties ..........................................................................................22
- Properties of a « AL 2003 » server equipment ...................................................23
- ALNET II client equipment properties .................................................................25
- Deleting an equipment ........................................................................................26
- Duplicating an equipment ...................................................................................26
- Moving an equipment..........................................................................................26

3. - Functions which can be used on the master channel............27


- In wait mode........................................................................................................27
- In deferred mode.................................................................................................27
- In cyclic mode .....................................................................................................27

4. - Image variable item ...................................................................28


- Presentation ........................................................................................................28
- Standard descriptor.............................................................................................29
-"ALNET II ALTUS descriptor"...............................................................................32

5. - Appendices ................................................................................36
- List of additional files for ALNET II on TCP.........................................................36
- Evolution / compatibility.......................................................................................36
- Function return statuses......................................................................................37
- TCP/IP appendix .................................................................................................39

6. - Glossary .....................................................................................44

7. - Index ...........................................................................................46

ALNET II on Ethernet TCP/IP •i• Table of contents


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

1. - General

- OSI model
The ALNET II on TCP/IP protocol by manufacturer ALTUS, is available on the applicom®
PCI2000ETH interface and SW1000ETH.
The ALNET II on TCP/IP protocol uses ALNET II messaging for the application layer and TCP/IP
for communication on Ethernet. All layers produced for ALNET II on TCP can therefore be represented
according to the following OSI model :

Figure 1 : applicom® TCP/IP functionality faced with the OSI model

applicom® uses the following specifications :

ALNET II on Ethernet TCP/IP •1• - General


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
All TCP/IP protocols are made according to the RFCs (Request For Comments):

TCP/IP
Layer 4 TCP : RFC 793
UDP : RFC 768
ICMP : RFC 792
Layer 3 IP : RFC 791
ARP : RFC 826
Layer 2 b Ethernet II
Layer 2 a IEEE 802.3 CSMA/CD

Layer 5 and 6 are not used.

ALNET II messaging (layer 7) is carried out according to ALTUS specifications :

ALNET II on Ethernet TCP/IP •2• - General


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Functionality
The TCP/IP solution on applicom® supplies the following functionality :

Figure 2 : applicom® client/server functionality

Multi-request client mode on Ethernet TCP/IP :


Reading and writing variables in the various PLC memory areas.

Server mode for ALNET II client PLCs, access to the applicom® database and equipment
monitoring.

Redundancy of equipment: enables the application to dynamically change the target


equipment. (see chapter Functions for Redundancy of Equipment).

ALNET II on Ethernet TCP/IP •3• - General


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Client multi-request management
The applicom® client mode can be used to send several requests simultaneously to an equipment
before having received the first response : this operation is called multi-request.
A request is sent on a virtual communication channel. Each virtual channel corresponds to a TCP
connection to an equipment.
To send several requests simultaneously, several connections are used.

Figure 3 : Multiple connections and multi-request

The connections are created according to needs, and existing connections are reused whenever
possible.
For example: a request is sent to an equipment for the first time. The connection No. 1 is created.
Some time later, 2 requests must be sent to the equipment: connection No. 1 is reused and connection
No. 2 is created.

The applicom® interface manages 128 connections. Only 30 of them can be used
simultaneously for all equipments.
The maximum number of connections which can be used simultaneously for this equipment is set in
the configuration for each equipment. For equipments which do not accept several connections, this
number is set at 1 and cannot be modified.

A connection remains open as long as data is travelling or a connection servicing process is active.

ALNET II on Ethernet TCP/IP •4• - General


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Request processing.

A request being processed is a request for which a frame has been sent on the network and for
which a response is expected.

Each request being processed uses a virtual communication channel.

A request is placed (temporarily) on hold when there are no more virtual channels available. When
virtual channels are released, the list of requests on hold is progressively emptied.

ALNET II on Ethernet TCP/IP •5• - General


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

2. - ALNET II on TCP/IP functionality

- ALNET II client to a « AL 3405» type server

- PLC/Ethernet coupler reference

AL 2003 processor :

Ethernet driver :
Ref. : AL 3405 (10 BaseT connection / AUI)

- Addressing mode

The functions managed by choosing a « ALTUS» type server equipment provide access to the
variables defined in the following table.
When using the applicom® library, the address of the variable accessed must be converted by
referring to the « Adressing » column in the following table. Note the difference of 1 between the
addresses of ALTUS variables and applicom® addresses.

Function code PLC variable Item Use by the


(DDE/ OPC) applicom®
library/DLL
Addresses Exchange type Function name
9 %A0 - %A254 0 – 254 Read byte READPACKBYTE
9 %A0 - %A254 0 – 254 Write byte WRITEPACKBYTE
8 %E0 - %E254 0 – 254 Read input byte READPACKIBYTE
8 %S0 - %S254 0 – 254 Write output byte WRITEPACKIBYTE
0 %M0 - %M9998 0 – 9999 Read word READWORD
0 %M0 - %M9998 0 – 9999 Write word WRITEWORD
20 %TM0 - %TM254 10000 – 65535* Read table word READWORD
20 %TM0 - %TM254 10000 – 65535* Write table word WRITEWORD
02 %D0 - %D9998 0 – 9999 Read double word READDWORD
02 %D0 - %D9998 0 – 9999 Write double word WRITEDWORD
22 %TD0 - %TD254 10000 – 65535* Read table word READDWORD
22 %TD0 - %TD254 10000 – 65535* Write table word WRITEDWORD

* : TM & TD applicomâ address calculation


TMx.y = (x * 255) + 10000 + y
example : TM10.120, address = (10 * 255) + 10000 + 120 = 12670

TDx.y = (x * 255) + 10000 + y


example : TD10.120, address = (10 * 255) + 10000 + 120 = 12670

ALNET II on Ethernet TCP/IP •6• - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

- Maximum numbers of variables per exchange with the library

Object Maximum quantity


Read Write
Bit 1840 1840
Word 115 115
Double 57 57

- Maximum numbers of variables per exchange with PCDDE

Object Maximum quantity


Read Write
Bit 1840 1
Word 115 1
Double 57 1

The number given for read frames corresponds to the maximum number of points (as imposed by
the server and/or the protocol) which can be grouped together during dynamic optimization of the frames
carried out by the server. However, this number can be reduced to suit a specific item of equipment by
configuring the length of frames in the topic (see chapter "Implementation/Topics configuration/Advanced
options").
Where write operations are concerned, a variable automatically entails the formation of a frame.

- Maximum numbers of variables per exchange with the OPC server

Object Maximum quantity


Read Write
Bit 1840 1840
Word 115 115
Double 57 57

The number given for read frames corresponds to the maximum number of points (as imposed by
the server and/or the protocol) which can be grouped together during dynamic optimization of the frames
carried out by the server. However, this number can be reduced to suit a specific item of equipment by
configuring the length of frames in the topic (see chapter "Implementation/Topics configuration/Advanced
options").
For the write frames, see chapter "OPC Server/Optimization of synchronous and asynchronous
requests".

ALNET II on Ethernet TCP/IP •7• - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- ALNET II server
The ALNET II server on applicom® interface makes a database of 32 kwords available to ALNET
II clients.
Without any prior configuration, Alnet II clients can access the applicom® database directly by
targeting the port number 1 to 65535 (port TCP) of the applicom® Alnet station. The access mode is
identical to that of a ALUS.

Supported Data type in the Addresses in the Corresponding


Request DATA-BASE DATA-BASE ALNET II variables
Read /write auxiliary word area 25000 – 25127 0 – 512
Read /write memory word area 0 – 9999 0 – 9999
Read /write decimal word area 10000 – 19999 0 – 4999
Read /write tab memory word area 26000 – 28816 0 – 10
Read /write tab decimal word area 28817 - 31633 0–6

Maximum number of variables per exchange:

230 bytes
115 words
57 double words

The ALNET II server functionality on the applicom® database can be used to optimise information
feedback. Rather than permanently polling the equipments to monitor variables which change
status occasionally, the equipments can store the information to be fed back in the applicom®
database only on status changes (alarm feedback). This operating mode results in:

• PLC processors less solicited.


• Network architecture less heavily loaded.
• Minimized information feedback time.

This principle can be made reliable on the ALNET II server on applicom® interface to avoid
working « blind ». For example, the variables in the applicom® database do not change since the
transmitting equipment is disconnected. To do this:

• You can define in the configurator a global maximum time between the accesses of the client
equipment to the applicom® ALNET server. After this interval, the absence is indicated to
the application by a « ACCESS STATUS WORD » in the applicom® database. The address
of this status is defined by you using the channel configuration utility.

• The application is informed of the write access by each equipment to the applicom® ALNET
II server by incrementing an « ACCESS INDICATOR WORD » in the applicom® database.
The application can consult the variables of this equipment in the applicom® database and
reset the « ACCESS INDICATOR WORD » to be informed about the next access (or even to
inform the transmitting equipment of this acknowledgment).

ALNET II on Ethernet TCP/IP •8• - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

- Configuration : Choice of protocol


The ALNET II on TCP/IP protocol can only be configured on channel 0 of the applicom®
PCI2000ETH interface and SW1000ETH.

Figure 4 : Choice of protocol

Choose the “Alnet II TCP/IP (Altus)” messaging (protocol) and press the « OK ...» button to
configure the channel and the equipments.

ALNET II on Ethernet TCP/IP •9• - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
After your configuration, the following files will be generated :

CNFMAST.0xy : contains the configurations of the Ethernet channel, the TCP transport layers
and the Client mode.
CNFSERV.0xy : contains the configuration of the Server mode and the client equipments.
CNFCMNT.Sxy : contains the comments on each equipment
APPCNFGy.LST : contains a summary of the ALNET II on TCP configuration in ASCII format.
CNFSCH01.1xy : contains the configuration of the ALNET II server equipments.

x represents the channel number ( 0 to 3 ) and y represents the board number ( 1 to 8 ).

ALNET II on Ethernet TCP/IP • 10 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

- Description of the ALNET II configurator on TCP/IP

Figure 5 : Alnet II configurator on applicom® TCP/IP

The configuration is represented in a tree structure. The first node (symbolized by a board)
designates the Ethernet channel. The TCP/IP transport nodes and then the server and client equipments
are found below.

This interface can be operated by :


• the main menu
• the tool bar
• the popup menus
• the short keys

ALNET II on Ethernet TCP/IP • 11 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Node characteristics
Select a node and click on the right button to display the following contextual menu :

Figure 6 : Contextual menu

Depending on the type of node (channel, TCP/IP or equipment) certain lines in the menu will not be
accessible (grayed).

Remark : The properties of a node can also be accessed directly with the key « F2 », « Enter » or
by double-clicking on the node.

ALNET II on Ethernet TCP/IP • 12 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Channel properties : General

Figure 7 : Channel properties : General parameters

DATA-BASE : check words of client equipments

Access status address


Check the « Active functionality » box to validate operation and specify the storage address of
the 60 « access status words » in the applicom® database.
Value from 0 to 31935, default value 0.
This option is used to monitor the access interval of the client equipment to the applicom®
server mode. If the « Access monitoring time-out » configured in the equipment (see
configuration of client equipment) is exceeded, the applicom® interface will indicate its absence
in the word corresponding to the client equipment number.

1st word Client equipment number 0


..
60th word Client equipment number 59

Value of the access status word :


0 : the equipment accesses the applicom® server in the defined time,
4 : the client equipment accesses inaccessible data in the applicom® server,
33 : the client equipment does not access the applicom® server within the defined time,
36 : the targeted equipment is not configured

ALNET II on Ethernet TCP/IP • 13 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
Access indicator address
Check the « Active functionality » box to validate operation and specify the storage address of
the 60 « access indicator words » in the applicom® database.
Value from 0 to 31935, default value 0.
All write access by a client equipment to the applicom® server will be indicated by
incrementing the word corresponding to the number of the client equipment configured.

1st word Client equipment number 0


..
60th word Client equipment number 59

This word has a maximum value of 65535; you must reset this value so that the word can count
the accesses again .

ALNET II on Ethernet TCP/IP • 14 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
Requests being processed

Time-out
Maximum time separating the transmission of a request by the applicom® client from the
response by the server.
When the equipment does not answer within this time-out, the current request returns status 55
« Message lost »
Value in seconds, from 2 to 255, default value 10.

Maximum number
Sets the maximum number of requests being processed. Above this figure, the requests are
placed on a waiting list until a request being processed is released.
The number of requests being processed indicates a number of requests sent simultaneously on
the network. These requests contribute to the network load.
By modifying the maximum number of requests being processed, this load can be regulated.
Two possible cases may then arise for applications including an applicom® interface and PLCs
:
dedicated network : the maximum number of requests being processed proposed by default
optimises the performance of the communication support.
network shared with workstations : in case of network overload (>30%), the maximum
number of requests pending must be reduced. This is done to preserve the pass band for the
other stations.
Value from 1 to 32, default value 12 (default value 16 in multi-messaging).

ALNET II on Ethernet TCP/IP • 15 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Channel properties: Ethernet

Figure 8 : Channel properties : ethernet

Connection type
This choice determines which type of physical interface is used (DB15 or RJ45 connector) :
AUI (Attachment Unit Interface) : DB15 connector to connect a transceiver (drop cable or direct
transceiver),
10 Base T/RJ-45 : integrated transceiver, star topology, double twisted pairs RJ45 connector,

Baud rate (PCI2000ETH version B only)


Allow you to select the baud rate if the connection type is RJ45. The choice « auto 10/100Mb »
squares with an automatic detection of the baud rate.
Default baud rate: 10Mb with the AUI connection type and « auto 10/100Mb » with the RJ45
connection type.

Connection lifetime
Maximum inactivity time for a TCP connection. A connection is active when data is transiting or
when it is being serviced (configurable procedure in TCP). After this time, the connection is
closed, in order to avoid overloading connections (max. 128) when the partner is absent.
Value in minutes, from 2 to 60, default value 3.

ALNET II on Ethernet TCP/IP • 16 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
Channel Ethernet address
Address on 6 bytes defining the Ethernet channel uniquely on the network.

Manual input (« Automatic calculation » not checked ):


Enter the Ethernet address in hexadecimal. if you enter an address, then the address which will
be used is the one you entered.

Automatic address calculation :


This address can be calculated automatically from the applicom® IEEE address and the board
serial number :

The serial number is indicated by labels on the applicom® interface (on the rear plate and on
the copper) or visible when initialising the interface (« applicom initialisation »).

Example:
Ethernet address of an applicom® interface bearing serial number 20100 i.e. 4E84
Hexadecimal.

ALNET II on Ethernet TCP/IP • 17 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

- Alnet II properties:

Figure 9.1 Alnet II properties

Parameter:
Node Number: network address of applicom® station.

ALNET II on Ethernet TCP/IP • 18 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Properties of the TCP/IP protocol
See "- TCP/IP appendix" on page 39 for further details.

IP parameters

Figure 10 : TCP/IP properties

applicom channel IP address


Zone of 4 bytes entered in pointed decimal notation representing the Internet address or IP
address of the applicom® board channel.

Gateway IP address
IP address of a machine likely to perform a routing to another network (internal or external).

Sub-network mask
Used to define the addresses to be routed by the gateway.
Value « 0.0.0.0 » to « 255.255.255.255 », « 255.255.255.0 » by default.

The « Advanced parameters » button provides access to expert settings for TCP/IP.

ALNET II on Ethernet TCP/IP • 19 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Advanced parameters

For further details, consult "- Time-out TCP" on page 42

Figure 11 : TCP/IP advanced parameters

Number of retries
Number of times that the applicom® board attempts to retransmit a non-acknowledged TCP
packet.
Value from 1 to 12, default value 2.

Interval between retries


Maximum time between two retries. The time between retries increases on every attempt. This
parameter related to the number of retries, can therefore be used to determine a global time-out
for transmission of a TCP packet.
Value in seconds, from 1 to 5, default value 1.

If a TCP packet is not acknowledged and terminates in time-out, the connection is closed and
the function then returns a status 33 « Time-out ».

Connection servicing
Activation of the TCP/IP « keep alive » function used to keep the TCP connections open with a
periodic check that the partner is present.

ALNET II on Ethernet TCP/IP • 20 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

- Inserting an equipment
• From a « Server equipment » or « Client equipment » node :

o Press the « INS. » key or choose the command Add an equipment in the popup menu.
The « Insert new equipment » dialog box is displayed.
o Then follow the instructions in chapter "- Equipment properties" on page 22.

• From an equipment which is already configured :

o Press the « INS. » key or choose the command Add an equipment in the popup menu.
o The dialog box described in chapter "- Equipment properties" on page 22 is opened
directly.

ALNET II on Ethernet TCP/IP • 21 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Equipment properties
Generally, all server or client equipments will be composed of a common « applicom®
description » for all equipment types, a « Network parameters » zone to enter the equipment address,
and lastly a « Messaging parameters » zone specific to each equipment type.

applicom description

Equipment number
applicom® equipment number to be chosen from the list of non-configured equipments.
Value:
000 to 127 for server equipments,
000 to 59 for client equipments,

Active configuration
Check box to activate the equipment configuration in the applicom® interface : used to delete an
equipment from the applicom® interface whilst keeping its configuration in applicom console.

Link parameters
Check box to automatically link the last byte of the IP address, and the node number of the
station.

Symbolic name
The symbolic name is used as TOPIC, for OPC or the DDE server, PCDDE.

Comment
Free text about an equipment. The maximum number of characters is 80.

Network parameters

IP address of the equipment.


IP address of the partner equipment.
The complete address in TCP/IP includes an IP address and a port number (Port TCP), which is
used to identify the application using the connection. Generally the port number is predefined by
the PLC manufacturer.
However, certain types of equipment offer the possibility of modifying this port. In this case a
« Equipment TCP port » entry zone will be displayed in the "Network parameters" box.

ALNET II on Ethernet TCP/IP • 22 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Properties of a « AL 2003 » server equipment
After selecting the « Altus» equipment, choosing the equipment number and entering the network
parameters, you must define the « messaging parameters » zone:

Figure 12 : Properties of a AL 2003 server equipment

ALNET II on Ethernet TCP/IP • 23 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

Figure 14 : Properties of a AL 2003 server equipment

applicom description

See chapter "- Equipment properties" on page 22.

Network parameters

See chapter "- Equipment properties" on page 22.

Messaging parameters:

Node Number :
Node number of Altus station

ALNET II on Ethernet TCP/IP • 24 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

- ALNET II client equipment properties


Remark :
Access to the server functionality of the applicom® interface requires no configuration. The
client must simply target the applicom® IP address on the port TCP number 405 (access identical
to that of a PLC).
This configuration is only required to use the functionality of monitoring clients to the applicom®
server (Access time-out and detection of writing in the applicom® database). See chapter "- ALNET II
server" on page 8.

After choosing the equipment number and entering the network parameters, you must define the
« messaging parameters » zone:

Figure 13 : Alnet II client equipment properties

applicom description

See chapter "- Equipment properties" on page 22.

Network parameters

See chapter "- Equipment properties" on page 22.

Messaging parameters

Access time-out
Definition of the access time-out to the applicom® ALNET II server.
Value from 0 to 65535, default value 5.

This value determines the maximum time interval between the accesses of the client to the
applicom® server. After this delay, its absence will be automatically indicated in the « Access
status words » of the applicom® database, see "- Channel properties : General" on page 13.

ALNET II on Ethernet TCP/IP • 25 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Deleting an equipment
1. Select the equipment to be deleted.
2. Click on the right button to display the popup menu.
3. Choose the Delete command.

You can also use the keyboard shortcut « Del. ».

This command is irreversible.

- Duplicating an equipment
1. Select the equipment to be duplicated.
2. Choose the Copy (Ctrl+C) command.
3. Select the insertion position
4. Choose the Paste(Ctrl+C) command.V

- Moving an equipment
1. Select the equipment to be moved.
2. Choose the Cut (Ctrl+X) command.
3. Select the insertion position
4. Choose the Paste(Ctrl+C) command.V

ALNET II on Ethernet TCP/IP • 26 • - ALNET II on TCP/IP functionality


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

3. - Functions which can be used on the master


channel

- In wait mode
readpackbyte Writepackbyte
readpackibyte
readword writeword

readdword writedword

- In deferred mode
readdifbit writedifpackbit
readdifibit
readdifword writedifword
readdifiword
readdifdword writedifdword
readdiffword writediffword

testtransdif transdif transdifpack

- In cyclic mode
createcyc
startcyc stopcyc actcyc
transcyc transcycpack

Variable in the Function type


equipment Read Write
Packed bytes X X
Packed input bytes X

Words X X
BCD words X X
Input words X

Double words 32 bits X X

ALNET II on Ethernet TCP/IP • 27 • - Functions which can be used on the master


channel
electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

4. - Image variable item

- Presentation
The "image variable items" are all syntaxes which can be used to access variables via the
"PCDDE" DDE server or the OPC server

- With the DDE server, the item corresponds to the "item name" part of the DDE connection defined by:
- application name
- topic name
- item name
For further details, refer to the chapter "Principle of the DDE protocol" in the "DDE and OPC servers"
manual.

- With the OPC server, the item represents the last part of the "ItemId" parameter.
For further details, refer to the chapter "Access to an OPC variable" in the "DDE and OPC servers"
manual.

Depending on the configuration of each equipment, the most adapted descriptor is by default
automatically determined by the server. With the ALNET II protocol on TCP/IP, the default descriptors
are :
the « ALNET II descriptor » for the AL 2003 equipments,

You can, however, force the use of another descriptor (especially the applicom® standard
descriptor) by using the advanced options

ALNET II on Ethernet TCP/IP • 28 • - Image variable item


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Standard descriptor
The standard descriptor is used to access the equipment which does not have a specific descriptor.
The address field in the « item » name can go up to 10 digits. A linear address can therefore be
composed ranging from 0 to 4 giga.

Unitary mode Table Mode, Matrix Mode


Internal bits Bx Bx_n, Bx_n_l
Input bits BIx BIx_n, BIx_n_l
Internal words Wx Wx_n, Wx_n_l
Bits in the internal words Wx.b
Input words WIx WIx_n, WIx_n_l
ASCII string in the internal words M_Wx_n
Internal double words Dx Dx_n, Dx_n_l
Internal floating words Fx Fx_n, Fx_n_l

Remark : The limiting values of parameters n and 1 depend on the protocol. However, for PCDDE,
they cannot be greater than 128 for bits and bytes, 64 for words, 32 for double words and floating words.

To consult the read and write limits, refer to the sections:

AL 2003 type server


- Maximum numbers of variables per exchange with PCDDE
- Maximum numbers of variables per exchange with the OPC server

- Internal bits Bx (type : BIT)

x : Number of the first bit.


Example: B4

- Internal bits Bx_n, Bx_n_l

n: Number of bits.
l: Number of bits per line (Matrix mode only).
Examples : B4_10, B4_10_5

- Input bits BIx (type : BIT)

x : Number of the first bit.


Example: BI4

- Input bits BIx_n, BIx_n_l

n: Number of bits.
l: Number of bits per line (Matrix mode only).
Examples : BI4_10, BI4_10_5

ALNET II on Ethernet TCP/IP • 29 • - Image variable item


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Internal words Wx (type : 16 bit WORD)

x: Number of the first word.


Example: W4

- Internal words Wx_n, Wx_n_l

n : Number of words.
l: Number of words per line (Matrix mode only).
Examples : W4_10, W4_10_5

- Bits in the internal words Wx.b (type : BIT)

For this syntax, the maximum numbers of variables per frame are:
in read: 128*16
in write: 1

x: Number of the first word.


b: Rank of the bit in the word (0 to 15).
Example : W4.5

- Input words WIx (type : 16 bit WORD)

x: Number of the first word.


Example: WI4

- Input words WIx_n, WIx_n_l

n: Number of words.
l: Number of words per line (Matrix mode only).
Examples : WI4_10, WI4_10_5

ALNET II on Ethernet TCP/IP • 30 • - Image variable item


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- ASCII string in the internal words M_Wx_n (type : 16 bit WORD)

For further information on the use of ASCII strings, you can consult chapter "Use of message
mode".

x: Number of the first word containing the string


n: Number of potential words that could contain the ASCII string (1 to 65).
Example: M_W100_30

In the example, the word array W100 to W129 can contain the string.

- Internal double words Dx (type : 32 bit WORD)

x: Number of the first double word.


Example: D4

- Internal double words Dx_n, Dx_n_l

n: Number of double words.


l: Number of double words per line (Matrix mode only).
Examples : D4_10, D4_10_5

- Internal floating words Fx (type : REAL IEEE 32 bits)

x : Number of the first floating word.


Example: F4

- Internal floating words Fx_n, Fx_n_l

n: Number of floating words.


l: Number of floating words per line (Matrix mode only).
Examples : F4_10, F4_10_5

ALNET II on Ethernet TCP/IP • 31 • - Image variable item


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

-"ALNET II ALTUS descriptor"

This descriptor can only be used for access to ALTUS 2xxx via OPC applicom® interfaces.

Unitary mode Table Mode, Matrix Mode


Internal bytes Ax Ax_n
Bits in internal bytes Ax.b
Input bytes Ex Ex_n
Bits in input bytes Ex.b
Output bytes Sx Sx_n
Bits in output bytes Sx.b
Internal words Mx Mx_n
Bits in the internal words Mx.b
Internal double words Dx Dx_n
Bits in Internal double words Dx.b
Internal table words TMx.y TMx.y_n
Internal table double words TDx.y TDx.y_n
Bit in internal table word TMx.y.b
Bit in internal table double word TDx.y.b
ASCII string in the internal bytes M_Ax_n
ASCII string in the internal words M_Mx_n

Remark : the limiting values of parameters n and 1 depend on the protocol. However, for PCDDE,
they cannot be greater than 128 for bits and bytes, 64 for words, 32 for double words and floating words.

To consult the read and write limits, refer to the sections:

ALNET II server
- Maximum numbers of variables per exchange with PCDDE
- Maximum numbers of variables per exchange with the OPC server

For addressing of variables, refer to the chapter - Addressing mode.

- Internal byte => Ax (type : 8 bit BYTE)

x : Number of the first byte (0 to 254).


Example: A4

- Bit in internal byte => Ax.b (type : 1 BIT )

x : Number of the first byte (0 to 254).


b :Rank of the bit in the word (0 to 7).
Example: A4.2

ALNET II on Ethernet TCP/IP • 32 • - Image variable item


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

- Input byte => Ex (type : 8 bit BYTE)

x : Number of the first byte (0 to 254).


Example: E4

- Bit in input byte => Ex.b (type : 1 BIT )

x : Number of the first byte (0 to 254).


b :Rank of the bit in the word (0 to 7).
Example: E4.2

- Output byte => Sx (type : 8 bit BYTE)

x : Number of the first byte (0 to 254).


Example: S4

- Bit in output byte => Sx.b (type : 1 BIT )

x : Number of the first byte (0 to 254).


b :Rank of the bit in the word (0 to 7).
Example: S4.2

- Internal words => Mx (type : 16 bit WORD)

x : Number of the first word (0 to 32767).


Example: M4

- Internal words =>Mx_n (type : 16 bit WORD)

x : Number of the first word (0 to 9998).


n : Number of words.
Examples : M4_10

- Bits in the internal words => Mx.b (type : BIT)

x : Number of the word (0 to 9998).


b: Rank of the bit in the word (0 to 15).
Example : M4.5

- Internal doubles words => Dx (type : 32 bit WORD)

x : Number of the first double word (0 to 9998).


Example: D4

ALNET II on Ethernet TCP/IP • 33 • - Image variable item


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

- Internal double words => Dx_n (type : 32 bit WORD)

x : Number of the first double word (0 to 9998).


n: Number of double words.
Examples: D4_10

- Bit in internal double words => Dx.b(type : 32 bit WORD)

x : Number of the first double word (0 to 9998).


b :Rank of the bit in the word (0 to 31).
Example: D4.2

- Internal table word => TMx.y (type : 16 bit WORD)

x : Number of the table (0 to 255).


y : Index of the table (1 to 254)
Example: TM4.1

- Internal table words => TMx.y_n (type : 16 bit WORD)

x : Number of the table (0 to 255).


y : Index of the table (1 to 254)
n : Number of the words (1 to 115)
Example: TM4.1_2

- Bit in Internal table words => TMx.y.b (type : 1 BIT)

x : Number of the table (0 to 255).


y : Index of the table (1 to 254)
b :Rank of the bit in the word (0 to 15).
Example: TM4.1_2

- Internal table double word => TDx.y (type : 32 bit WORD)

x : Number of the table (0 to 255).


y : Index of the table (1 to 254)
Example: TM4.1

- Internal table double words => TDx.y_n (type : 32 bit WORD)

x : Number of the table (0 to 255).


y : Index of the table (1 to 254)
n : Number of the words (1 to 57)
Example: TM4.1_2

ALNET II on Ethernet TCP/IP • 34 • - Image variable item


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

- Bit in Internal table double words => TMx.y.b (type : 1 BIT)

x : Number of the table (0 to 255).


y : Index of the table (1 to 254)
b :Rank of the bit in the word (0 to 31).
Example: TM

- ASCII string in the internal bytes => M_Ax_n (type : 8 bit WORD)

For further information on the use of ASCII strings, you can consult chapter "Use of message
mode".

x: Number of the first byte containing the string


n: Number of potential words that could contain the ASCII string (1 to 65).
Example: M_M100_30

- ASCII string in the internal words => M_Mx_n (type : 16 bit WORD)

For further information on the use of ASCII strings, you can consult chapter "Use of message
mode".

x: Number of the first word containing the string


n: Number of potential words that could contain the ASCII string (1 to 65).
Example: M_M100_30

ALNET II on Ethernet TCP/IP • 35 • - Image variable item


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

5. - Appendices

- List of additional files for ALNET II on TCP


CLIMETH. Multi-messaging TCP/IP client task
SERVMETH. Multi-messaging TCP/IP server task
NETMETH. Multi-messaging TCP/IP network management task
ISOL4. Layer for ISO transport task
TCP. TCP transport task
IPTCP. IP communication task
ARPTCP. ARP communication task
READMETH. Ethernet channel read task
WRITMETH. Ethernet channel write task

APDIAG.EXE Diagnostics utility


APPFBOLE.DLL DLL used by APDIAG.EXE

- Evolution / compatibility

This protocol is only available on the applicom® PCI2000ETH interfaces; EPROMs version 3.7 or
greater are required.

Compatibility :

Evolutions :

ALNET II on Ethernet TCP/IP • 36 • - Appendices


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Function return statuses
The various applicom® functions return a status word to:
- Guarantee the quality of the request.
- Diagnose the cause of a failure.
The meaning of the status word value is detailed in the following tables. As well as the general
meaning, « Additional Information » will enable you to orient your diagnosis according to the protocol
used.

- General applicom® statuses

-6 The function TRANSCYC (or TRANSCYCPACK) is used with a cyclic function number which was activated but
is no longer.
-5 The user program is attempting to make a deferred transfer TRANSDIF (or TRANSDIFPACK) although the
current deferred request is not finished.
-1 Deferred transfer request TRANSDIF (or TRANSDIFPACK) concerning a write which took place correctly.
0 No anomaly detected. The function was executed correctly.
1 Unknown function.
The function requested is not supported.
2 Bad address.
The address of the variable that you are soliciting is bad.
3 Bad data.
Additional information :
Function : BINBCD, BCDBIN.
- At least one of the values accessed is not in BCD format (0<= value <= 9999).
4 Inaccessible data.
32 Bad parameter passed to the function.
Bad number of variables.
35 Data not available in cyclic read.
Attempt to transfer data by TRANSCYC (or TRANSCYCPACK) before reading the data
in the equipment.
40 Deferred read or write attempt by a task when the maximum number of tasks which can use deferred mode
simultaneously has been reached.
Another task must release resources by performing an exitbus.
41 Deferred read or write attempt when the deferred request register is full.
Perform deferred request transfers with TRANSDIF (or TRANSDIFPACK) to release the register (64 positions).
42 Deferred request transfer attempt with TRANSDIF (or TRANSDIFPACK) when it is empty (no deferred requests
to do).
45 Communication program not resident.
Initialze the applicom® interface before using it by entering the command applicom (or PCINIT under
Windows ).
®
46 Board number not configured, or applicom master/client function targeting a channel configured as
slave/server or vice versa.
47 No applicom® interface.
51 Driver system problem.
®
59 - Protection key missing on the applicom interface.
- Use of applicom® functions without calling the function INITBUS beforehand.
66 Not enough applicom® interface memory.

255 Used by the MS-Windows server « PCDDE ». Initial value of the items « STATUS_READ » and
« STATUS_WRITE ». This value indicates that no transaction was carried out between « PCDDE » and the
®
applicom interface.
Remark : negative statuses are information codes.

ALNET II on Ethernet TCP/IP • 37 • - Appendices


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Statuses relating to the protocol

0 No anomaly detected. The function was executed correctly.


2 Bad address.
The address of the variable that you are soliciting is bad.
Additional information :
Messaging on TCP/IP Ethernet :
- Returned by the coupler of the destination equipment. Access to a variable with a bad address or a number
exceeding the PLC zone.
3 Bad data.
Additional information :
- Incoherent frame content.
4 Inaccessible data.
Additional information :
- The physical address does not exist, non existent module or protected data.
33 Time-out fault.
Additional information :
- Equipment configured but not connected on the network. Wiring problem, the CPU does not run the
communication blocks, connection not declared or badly declared in the CPU.
- Bad IP address of the equipment or the gateway.
- To verify that the format of field Ethernet configured in the distant equipment is « ETHERNET II ».
36 Equipment not configured.
®
Define the equipment configuration with PCCONF and reinitialize the applicom product.
49 Queue time-out fault
The request could not be sent due to lack of resources (no communication channels available). This time
corresponds to 4 times the value of the time-out for the requests being processed.
Increase the value of the « time-out for requests being processed »
Increase the maximum number of simultaneous requests on the targeted equipment.
55 Response time-out exceeded, message lost.
Additional information :
- Time-out exceeding the value of the « time-out of requests being processed », connection
established, question acknowledged but no response.
®
66 Not enough applicom interface memory.
Additional information :
- Insufficient resources for additional connection.
70 Connection terminated by the remote equipment
Additional information :
- Connection aborted following a connection problem. Wiring problem, CPU in stop, the CPU does not run the
communication blocks.
- The aimed equipment does not support this messaging.

ALNET II on Ethernet TCP/IP • 38 • - Appendices


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- TCP/IP appendix
- IP address

Each interface on a TCP/IP network or sub-network must have a unique IP address.

Determination of this address depends on the network type :


open type network (e.g. : Connected to the worldwide Internet), the address or set of
addresses must be issued by an authorized organization in the country where the network is
installed,
closed type network (network internal to the company), the addresses are issued by the
network administrator.

An IP address is represented on 4 bytes (or 32 bits. It is composed of :


a network identifier,
a machine identifier.

Using these two identifiers, the IP addresses can be divided into 5 different classes:

Class A : 128 networks and 16777216 stations

0 network id 7 bits station id 24 bits

Class B : 16384 networks and 65536 stations

1 0 network id 14 bits station id 16 bits

Class C : 2097152 networks and 256 stations

1 1 0 network id 21 bits station id 8 bits

Class D :

1 1 1 0 multicast group id 28 bits

Class E :

1 1 1 1 0 reserved for future use 27 bits

Which gives us in pointed decimal notation :

Class Range
A 0.0.0.0 to 127.255.255.255
B 128.0.0.0 to 191.255.255.255
C 192.0.0.0 to 223.255.255.255
D 224.0.0.0 to 239.255.255.255
E 240.0.0.0 to 255.255.255.255

The choice of an internal address will therefore depend on the number of stations on this network; a
class C address is generally sufficient.

Special case : « loopback » destination address 127.0.0.1, this address can be used to test the
TCP/IP layer. A packet with destination address 127.0.0.1 will not leave on the network, the packet drops
down to the IP layer then goes straight back to TCP.

ALNET II on Ethernet TCP/IP • 39 • - Appendices


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Sub-network mask

Class A and B addresses include a large number of machines which are represented respectively
on 24 and 16 bits. It is therefore recommended to divide the machine identifier into sub-network identifier
and machine identifier.

For example, for a class B address :

1 0 network id 14 bits sub-network id 8 bits station id 8 bits

This breakdown authorizes 254 sub-networks, with 254 machines per sub-network.

The network mask can be used to specify the bits forming the sub-network mask.
This mask is a 32 bit word containing bits set to 1 for the network and sub-network identifiers, and
bits set to 0 for the machine identifier.

Example for a sub-network mask with class B address :

network id sub-network id machine id


16 bits 8 bits 8 bits
11111111 11111111 11111111 00000000

I.e. a sub-network mask of 255.255.255.0

Using its IP address and the sub-network mask, a machine can determine whether a packet is
intended for :

a machine on its own sub-network,


a machine on another sub-network (use of the gateway IP address),
a machine on a different network (use of the gateway IP address).

Example :
The applicom® board at IP address 140.152.3.25 with a sub-network mask of 255.255.255.0.
The address is therefore class B with a network ID of 140.152, a sub-network id of 3, and a
machine id of 25. The following equipments must be polled :
• Equipment 1 with address 140.152.7.10 : identical network id (140.152), different sub-network
id (7) => use of the gateway.
• Equipment 2 with address 140.152.3.20 : identical network id (140.152), identical sub-network
id (3), different machine id (20) => sent directly to the equipment.
• Equipment 3 with address 194.204.26.43 : different network id (class C) => use of the gateway.

ALNET II on Ethernet TCP/IP • 40 • - Appendices


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Gateway

The TCP/IP IP layer (layer 3) can be used to change network or sub-network via a dedicated
machine called a gateway or router. This machine must have at least two links on two different
networks.
When the destination address is on a different network, IP therefore uses the gateway IP address
to send the packet. This gateway handles this packet completely and returns it on the destination
network.

Example, transfer to an internal sub-network :

IP : 140.152.3.10
Gateway : 140.152.3.1
Sub-network mask : 255.255.255.0

PLC 1
applicom
international

PCI2000ETH
Equipment 1 140.152.3.2

Ethernet TCP/IP Network 1 140.152.3

140.152.3.1

GATEWAY

140.152.7.1

Ethernet TCP/IP Network 2 140.152.7

140.152.3.25

Equipment 2 140.152.7.10

IP : 140.152.7.10
Gateway : 140.152.7.1
Sub-network mask : 255.255.255.0
PLC 2

Figure 14 : IP gateway

The request intended for equipment 2 with address 140.152.7.10, is sent to the gateway
140.152.3.1 (transfer from network 140.152.3 to 140.152.7). The gateway returns the request to
equipment 2, which answers using gateway 140.152.7.1.

ALNET II on Ethernet TCP/IP • 41 • - Appendices


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- Time-out TCP

The TCP/IP protocol supplies a reliable transport layer, i.e. it manages the time-out and retry
procedures for packet acknowledgment.
The maximum number of retries is 12, and the time-out between each retry is variable. Initially, this
time is calculated using an estimation of the « d’return » time of a packet on the connection then
increases with the number of attempts exponentially up to a limit of 64 seconds, which generally
produces :

Retry 4 5 6 7 8 13
Interval 24 48 64 64 64 64 64 64 64
(seconds)
Time in 46.5 94.5 158.5 222.5 286.5 350.5 414.5 478.5 542.5
seconds Closing

1 2 3 4
3 6 12

0 1.5 4.5 10.5 22.5

Figure 15 : TCP time-out

We soon see that the wait time to know that a packet has not been acknowledged can be very
long : 542.5 seconds, i.e. over 9 minutes. The applicom® interface allows you to configure :
The number of retries,
The maximum interval between two retries.

To simplify the time-out calculation, it is easier to set the maximum interval between two retries to 1
second and then adjust the number of retries, by default the applicom® interface uses 2 retries, which
gives you a time-out of about 3 seconds.
On very disturbed or very saturated networks (load greater than 30 %), it is recommended to set 4
retries.

- Connection servicing

The TCP connections can be serviced with the « connection servicing » function in TCP/IP
« Advanced parameters » of (generally called « keep alive »). This servicing is used to keep the
connection alive even if there is no data circulating. Also, if the partner equipment no longer responds to
this servicing, the connection is automatically deleted.

The applicom® interface can be used to validate or not this operating mode. The operating mode
characteristics (which cannot be modified) are :

Servicing frequency : 30 seconds


Retry frequency : 20 seconds
number of tries if no response : 8

ALNET II on Ethernet TCP/IP • 42 • - Appendices


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
- TCP/IP extended statuses

The extended statuses for TCP/IP are used to refine the statuses related to the protocol, they can
be accessed with the utility « Diagnostics TCP-IP & ISO » by validating « Expert mode ».

1035 Ressource temporarily unavailable


1036 Operation now in progress
1037 Operation already in progress
1038 Socket default
1039 Destination address required
1040 Message too long
1041 Protocol wrong type for socket
1042 Protocol not available
1043 Protocol not supported
1044 Socket type not supported
1045 Operation not supported
1046 Protocol family not supported
1047 Address family not supported by protocol family
1048 Address already in use
1049 Impossible address
1050 No network
1051 Network is unreachable
1052 Network dropped connection on reset
1053 Software caused connection abort
1054 Connection reset by peer
1055 No buffer space available
1056 Socket is already connected
1057 Socket is not connected
1058 Can't send after socket shutdown
1061 Connection refused
1064 Host is down
1065 Host is unreachable

ALNET II on Ethernet TCP/IP • 43 • - Appendices


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

6. - Glossary

ARP
Address Resolution Protocol : address resolution protocol

ASCII
American Standard Code for Information Interchange

AUI
Attachment Unit Interface : interface between coupler and transceiver

Channel
Physical output of an applicom® board

Client
Equipment which takes the communication initiative

Coupler
Communication interface

CSMA/CD
Carrier Sense Multiple Access with Collision Detect : Multiple access with listening to the carrier
and collision detection

DATA-BASE
applicom® database of 32 kbits and 32 kwords

EPROM
Electronic component installed on the applicom® interface where non-erasable computer programs
are stored

ICMP
Internet Control Message Protocol : control message protocol using IP

applicom® interface
Communication board of type ISA or PCI, equipped with the applicom® real time multi-task kernel
(PC1000, PC2000, PC4000, PC1500PFB, etc.)

IP
Internet Protocol : inter-network protocol

Item
Defines a unit article or element

ITP
Industrial Twisted Pair : double industrial twisted pair developed by Siemens

LLC
Logical Link Control

OPC
Ole for Process Control

ALNET II on Ethernet TCP/IP • 44 • - Glossary


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
OSI
Open Systems Interconnection

PCDDE
applicom® DDE server

TCP port
Number which, associated with the IP address, enables TCP to identify the application using the
connection

RFC
Request For Comment : set of specifications describing amongst other things all TCP/IP protocols

TCP
Transmission Control Protocol

UDP
User Datagram Protocol : simple packet transmission protocol, not made reliable (no connection
nor retry).

ALNET II on Ethernet TCP/IP • 45 • - Glossary


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead

7. - Index

accessible variables, 6
addresses, 6
ALNET II
Client equipment properties, 25
Functionality, 6
Server, 8
Channel properties, 13, 16
Client equipment properties
ALNET II, 25
Configurator
Commands, 11
Configurator commands, 11
EPROM, 37
Equipment
Deleting, 27
Duplication, 27
Insertion, 20
Modification of properties, 12
Moving, 27
properties, 22
Error, 38
Ethernet, 16
Evolution, 37
Function return, 38
Functionality, 3, 6
Functions which can be used
Cyclic mode, 28
Deferred mode, 28
Wait mode, 28
Insertion rules, 20
IP
address, 40
gateway, 43
Sub-network mask, 42
IP addressing, 40
IP gateway, 43
IP Sub-network mask, 42
Item descriptor
Presentation, 29
Standard descriptor, 30
Telemecanique TSX/PMX descriptor, 32
Items
Standard descriptor, 30
Telemecanique TSX/PMX descriptor, 32
Maximum number of variables per TSX QUANTUM exchange
PCDDE, 7
Maximum number of variables TSX QUANTUM per exchange
OPC server, 7
Maximum numbers of variables per TSX QUANTUM exchange
Library, 7
Modbus client, 6
Multi-request, 4

ALNET II on Ethernet TCP/IP • 46 • - Index


electrical & safety · industrial connectivty · software & electronics · advanced connectivity

Woodhead
Network parameters, 22
OSI, 1
Requests, 13
Server equipment properties
TSX QUANTUM, 23
Status, 38, 39
TCP
status, 45
TCP
servicing, 44
time-out, 44
TCP servicing, 44
TCP status, 45
TCP/IP
Properties, 19
TCP/IP properties, 19
Time-out TCP, 44
TSX QUANTUM
Server equipment properties, 23
TSX QUANTUM limits
Library, 7
OPC server, 7
PCDDE, 7

ALNET II on Ethernet TCP/IP • 47 • - Index