You are on page 1of 4

Derate Tables

4000 Series 4012-46


Diesel Engines TAG1A, TAG2A, TAG3A
non-emissions compliant
4012-46TAG1A 1800 rev/min
Derate for high intake Temp. and/or elevated altitude from ISO 3046 standard conditions. Applies to tropical and temperate builds where
applicable.

20

18

16

14

12
Note : No derate required below 50°C and 2400 m asl.
Derate %

10

2
50°C

0
0 500 1000 1500 2000 2500
Altitude m asl

Note: Ambient temperature at air cleaner inlet.


4012-46TAG2A 1800 rev/min
Derate for high intake Temp. and/or elevated altitude from ISO 3046 standard conditions. Applies to tropical and temperate builds where
applicable.

20

18

16

14

12
Derate %

10 50°C

45°C
6

4 40°C

2
35°C

0
0 500 1000 1500 2000 2500
Altitude m asl

Note: Ambient temperature at air cleaner inlet.


4012-46TAG3A 1800 rev/min
Derate for high intake Temp. and/or elevated altitude from ISO 3046 standard conditions. Applies to tropical and temperate builds where
applicable.
50°C
20

18
45°C

16
40°C

14
35°C

12
30°C
Derate %

10

25°C
8

0
0 500 1000 1500 2000 2500
Altitude m asl.
Note: Ambient temperature at air cleaner inlet.
4000 Series 4012-46

Publication No. TPD1692E, issue 1. Printed in England. © Perkins Engines Company Limited

Distributed by

Perkins Engines Company Limited


Peterborough PE1 5NA United Kingdom
Telephone +44 (0) 1733 583000
Fax +44 (0) 1733 582240
www.perkins.com

All information in the document is substantially correct at the time


of printing but may be subsequently altered by the company.

You might also like