You are on page 1of 1

®

PRECAST CONCRETE PRODUCTS

www.precon.co.id

JACKING PIPES
Inside Dia. Thickness Outside Dia. Eff. Length Collar Length Collar Thickness Pipe Weight Collar Weight Crack Load Ultimate Load Axial Load
D0 – (mm) T – (mm) OD – (mm) L Eff – (mm) Lc – (mm) Tc – (mm) (kg) (kg) (Kg/m) (kg/m) (Tonnes)
450 67 584 688 19.0 4,300 6,500 107
600 78 760 1,076 24.7 4,700 7,100 133
700 83 866 1,266 27.9 4,900 7,400 187
800 93 986 1,652 30.8 7,200 10,800 230
900 103 1106 2,016 35.5 7,800 11,700 299
260 4.5
1000 112 1224 2,409 39.3 8,400 12,600 377
1100 115 1330 2,721 42.3 8,700 13,000 438
1200 128 1456 3,209 45.6 9,000 13,500 531
1300 133 1566 2430 3,737 64.5 9,300 14,000 578
1400 143 1686 4,270 66.9 9,600 14,400 624
1500 140 1780 4,702 73.6 10,200 15,300 794
1650 150 1950 5,534 80.6 10,800 16,200 945
260 6.0
1800 160 2120 6,371 91.0 11,400 17,100 1,109
2000 175 2350 7,716 100.8 12,000 18,000 1,364
2200 195 2590 9,131 110.9 12,600 18,900 1,646
2500 215 2930 300 9.0 11,843 195.8 13,500 20,250 2,123
Dimension tolerances, please see page 6.

Jacking for Direction

SPECIFICATION
Material Design
Concrete Strength : 500 kg/cm2 (Cube Compressive Strength @28 days) Live Load SNI 1725-2016 (Axle Load 22,5 Tons)
Steel Wire : Hard Drawn Deformed Wire fy > 5000 kg/cm2 Rail Way RM-19211 1~8 Axle Load
Steel Collar : Mild Steel Plate ST-37 (SS-41), Hot Dip Galvanized Excavation Depth 2.0~20.0m
Rubber Ring : Vulcanized Rubber, Ethyl Proopyldiene Monome Hidrostatic Test Pressure 120 kPa
Tensile > 8.5MPa, Hardness 45-55, Sulfate Resisting Rubber High Axial Load Application, the allowable jacking
Forces are affected by angular deflection during jacking

Standard Reference
Japanese Sewerage Water Work Association, JS-WAS A2 1991, Cls 2-500

For further technical assistance please contact our engineers


12 PT Dantosan Precon Perkasa | Concrete Pipe | Product Profile